FBA09A PANASONIC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Rated Operating Current Input Rated Max. Max. Static Noise Mass MODEL Voltage Voltage Power Speed Air Flow Pressure (V) (V) (A) *1 (W) *1 (min -1)*1 CFM*1 (m 3/min)*1 in H2O (Pa) *1 (dB) *1 (g) Rotation: Clockwise Airfl ow Outlet: Air Out Over Struts *1: Average Values in Free Air EMINEBEA.COM Units: inch (mm) FBA09A (92 X 25.5L) Failure Rate: 10% 50,000 Hours (40°C, 65%RH) Allowable Ambient Temperature Range: -10°C ~ +70°C (65%RH) (Operating) -40°C ~ +75°C (65%RH) (Storage) (non-condensing environment) Bearing: Hydro Wave Bearing 3.25 (82.5) 3.62 (92) 3.25 (82.5) 3.62 (92) 1.00 (25.5) - Pin + Pin LR99935 inlet outlet NAME PLATE Housing with solid corner type are available. ROTATION.177 8 – (f4.5) FLOW .157 (4) .157 (4) 60 3000 2000 1000 0 1 xä £ää 12V(24V)-L 12V(24V)-M 12V(24V)-H Air Flow (m3/min) N Normal Speed (min -1)(Pa)˜ÊÓ" Static Pressure Ps °ÓÎ °£x °äÇ 3.94 (f100) 3.25 (82.5) 3.54 (90) 3.54 (90) 3.25 (82.5) 3.54 (90) 3.25 (82.5) .185 4 – (f4.7) INLET SIDE 4.09 (f104) 3.25 (82.5) 3.54 (90) OUTLET SIDE .185 4 – (f4.7)

FEATURES

1 Revolution

S S S VL V goes VL to VH Signal given when fan is locked up Available Models Part Number Suffix

2 PULSE PER REVOLUTION SIGNAL

If fan locks on VH, signal stays locked. If fan locks on VL, signal stays at VL for a few hundred MS, then moves to VH. Axial models except: FBK04F FBA06T FBA08T FCB FAL 1BX Signal given when fan is locked up Available Models Part Number Suffix A B VL Lock In Panaflo FBA series models, a locked rotor alarm sensor is available in all models. For Blowers and Crossflo fans, a locked sensor can be provided as an option. A pulse sensor that transmits signals when the motor rotates is also available as an option. The 2 pulse per revolution sensor output is available in all FBA Series models except the 15 mm “T” versions. Specifications of Various Sensors Panaflo Built-in Connector System Lead Wire Connectors: Style: MASS TERMINATION (standard) AMP P/N 173977-3 CRIMP TYPE (this style is a 2 piece assembly) AMP P/N 175778-3 (housing) AMP P/N 175102-1 (terminal) Notes:

  • Connector style effects lead wire guage. Please refer to fan specs for further details.
  • All axial fans except the FBA06T, FBA08T and FBKO4F versions come standard with the mass termination connector. The FBA06T, FBA08T and FBKO4F fan leads are connected directly to the PC board in the fan assembly.
  • All FCB Crossflo models and FAL Blower fan leads are soldered directly to the PC board in the fan assembly.
  • Locked rotor protection circuits
  • Automatically restarts in a few seconds
  • Reverse voltage protection Insulation Resistance
  • 10M Ω minimum at 500v DC (frame to leads) Dielectric Strength
  • 500v AC (50/60Hz) for 1 minute (frame to leads) Plastic Rating
  • All Panaflo fans are manufactured with a UL94V-0 plastic (flammability) Insulation Class
  • JIS Class E (120° C)
  • VDE Class E (90° C)
  • UL Class A (105° C)
  • CSA Class A (105° C) Noise Data The noise data is measured at 1 meter from the air intake side of the fan suspended in a semi-anechoic chamber (background noise 13dB-A max.). Construction with and without Solid Corner Housing Panaflo fans are available in two different versions for mounting: with solid corner housing and without. Specific mounting methods and applications require the use of solid corners. Select the appropriate housing for your application. Some mod- els may be available only with solid corner housing. For details, please refer to the corresponding page for each model. With Solid Corner Without Solid Corner Microphone Microphone Microphone * Distance 1m. Noise Data

PANAFLO FAN PRODUCT DESIGNATION CODE Panaflo Fan FBAO8A12H1AS Bearing Type A: HWB (Hydro Wave) K: Ball Bearing (40mm Only) Housing Size 04: 40 x 40mm 06: 60 x 60mm 08: 80 x 80mm 09: 92 x 92mm 12: 120 x 120mm Housing Thickness A: 25.5mm T: 15mm (Thin) G: 38mm F: 20mm Rated Voltage 12: 12 VDC 24: 24 VDC 05: 5 VDC Speed L: Low M: Middle H: High U: Ultra High V: Variable (Option) Lead Wire (FBA Only) A: Standard 2 leads (GND, PWR) B: Standard 3 leads (GND, PWR, Signal) C: 3rd lead thermal sensor (variable) Option S: Locked rotor alarm sensor Z: Solid corner housing X: 2 PPR speed sensor (TAC Output) O: S + Z 1: Hub mounted thermal sensor Terminal (FBA Only) 1: With leads : No leadsMotor Type FB: Panaflo (DC Axial-flow fan)Crossflo Fan FCB34AD24S Option S: Locked rotor alarm sensor S Option S: Locked rotor alarm sensor Fan Outside Diameter 34: Ø34 mm Rated Voltage 12: 12 VDC 24: 24 VDC Fan Motor Length AA: 134.50mm AB: 173.50mm AC: 212.50mm AD: 251.50mm AE: 290.50mm AF: 329.50mm Motor Type FCB: Brushless Crossflo Fan Blowers FAL6F12LH Speed LL: Low Speed LH: High Speed Model Change Blower Size 3—50 x 50mm (Ball Bearing) 5—76 x 76mm (Hydro Wave) 6—109 x 114mm (Hydro Wave) Rated Voltage 05: 5 VDC 12: 12 VDC 24: 24 VDC Motor Type FAL: Brushless Fan (variable)

Type Model Rated Operating Rated Rated Nominal Maximum Maximum Noise Safety and Size Voltage Voltage Current Input Speed Air Flow Air Pressure (dB-A) Standard (V) (V) (mA) (W) (r/min) (m3/min) (CFM) (mmh20) (Pa) UL CSA Locked Rotor Alarm Sensor DC AXIAL FANS

Type Model Rated Operating Rated Rated Nominal Maximum Maximum Noise Safety and Size Voltage Voltage Current Input Speed Air Flow Air Pressure (dB-A) Standard (V) (V) (mA) (W) (r/min) (m3/min) (CFM) (mmh20) (Pa) UL CSA Locked Rotor Alarm Sensor CROSSFLOBLOWERS