FB8209H0908.3 PF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Unicom Com Unit for PROFIBUS DP/DP-V1 FB8209H0908.3 < Interface between the I/O modules and the PCS/PLC < Com unit for 80 analog or 184 digital channels < Communication via PROFIBUS DP < Installation in suitable enclosures in Zone 1 < HART communication via PROFIBUS DP V1 or service bus < Configuration via FDT 1.2 DTM < Configuration in run (CiR) for any PCS < Non-volatile memory for configuration and parameter settings < Self configuration in redundant systems < Permanently self-monitoring < Outputs drive to safe state in case of failures Unicom Com Unit for PROFIBUS DP/DP-V1 Function The PROFIBUS com unit forms the interface between the I/O modules on the backplane and the process control system. It supports all single width and dual width I/O modules. Thereby signals from NAMUR sensors, mechanical contacts, high-power solenoid drivers, power relays, sounders, and alarm LEDs are transported to the higher-level bus system. The com unit can be easily configured via DTM and supports redundancy as well as HART. Configuration in Run (CiR) enables configuration of a running system without a PROFIBUS restart, even in non-redundant systems. Connection Zone 1 Zone 1 to I/O zu E/A COM RAM µC FLASH PROFIBUS DP Service bus Servicebus Local connection (redundancy) lokale Verbindung (für Redundanz) Technical Data Slots Occupied slots 2 Supply Connection backplane bus Rated voltage Ur 5 V DC , only in connection with the power supplies FB92** Power dissipation 1.8 W Power consumption 1.8 W Fieldbus connection Release date: 2021-12--

01 Date of

Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 70106285_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Fieldbus type PROFIBUS DP/DP-V1 PROFIBUS DP Connection wired to Ex e terminals via backplane Baud rate up to 1.5 MBit/s Protocol PROFIBUS DP/DP V1 read/write services Number of stations per bus line max. 125 (PROFIBUS), max. 119 (service bus) Cyclic process data 240 bytes input and (simultaneously) 240 bytes output Number of stations per bus segment max. 31 (RS-485 standard) Number of repeaters between Master and Slave max. 3 Supported I/O modules all FB remote I/O modules Configuration (240 bytes I/O) Standard: 80 analog, 184 digital Universal 2I2O: 48 analog, 184 digital Universal 4I4O: 60 analog, 120 digital Bus length max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd) Addressing via configuration software PROFIBUS address 0 ... 126 (factory standard setting: 126) GSE file CGV61710.gsd/gse HART communication via PROFIBUS or service bus Internal bus Connection backplane bus Redundancy via front connector Indicators/settings LED indication LED green (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active LED red (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED yellow (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1 Conformity Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Environmental test EN 60068-2-14 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Damaging gas EN 60068-2-42 Relative humidity EN 60068-2-56 Ambient conditions Relative humidity 95 % non-condensing Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 (module) , a separate housing is required acc. to the system description Connection via backplane Mass approx. 750 g Unicom Com Unit for PROFIBUS DP/DP-V1 FB8209H0908.3 Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 70106285_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Dimensions 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) Data for application in connection with hazardous areas EU-type examination certificate Presafe 19 ATEX 14058U Directive conformity Directive 2014/34/EU EN 60079-0:2012+A11:2013 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015 EN 60079-11:2012 International approvals ATEX approval Presafe 19 ATEX 14058U IECEx approval IECEx PRE 19.0013U Approved for Ex db eb q [ib] IIC Gb General information System information The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate. Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Assembly P 1 2 Front view Socket for removable plug blue (accessory) Space for labelling Power LED green Status LED red Status LEDs yellow Accessories DTM LB/FB DTM collection FB9224* Field Unit FB9225* Redundancy Field Unit FB9248* Field Unit Unicom Com Unit for PROFIBUS DP/DP-V1 FB8209H0908.3 Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 70106285_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091