FB6208B PF | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Digital Output with Shutdown Input FB6208B < 8-channel < Outputs Ex ib < Installation in suitable enclosures in Zone 1 < Module can be exchanged under voltage (hot swap) < Galvanic group isolation < Line fault detection (LFD) < Positive or negative logic selectable < Simulation mode for service operations (forcing) < Permanently self-monitoring < Output with watchdog < Output with bus-independent safety shutdown input Function The device features 8 independent channels. The device can be used to drive low power solenoids, sounders, or LEDs. Open and short-circuit line faults are detected. The outputs are galvanically isolated from the bus and the power supply. The outputs can be switched off via a contact. This can be used for bus-independent safety applications. Connection Zone 1 COM I II III IV 11+ 13+ V VI VII 16- 15+ VIII Zone 1, 21 Technical Data Slots Occupied slots 2 Functional safety related parameters Safety Integrity Level (SIL) SIL 2 Supply Connection backplane bus Rated voltage Ur 12 V DC , only in connection with the power supplies FB92** Power dissipation 2.35 W Power consumption 2.35 W Internal bus Release date: 2021-11--
28 Date of
Release date: 2021-11-28 Date of issue: 2021-11-29 Filename: 542111_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Interface manufacturer-specific bus to standard com unit Digital output Number of channels 8 Suitable field devices Field device Solenoid Valve Field device [2] audible alarm Field device [3] visual alarm Connection channel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V: 9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16- Current limit Imax 8 mA Open loop voltage 20 V Line fault detection can be switched on/off for each channel via configuration tool Test current 0.33 mA Short-circuit < 300 Ω Open-circuit > 50 kΩ Response time 20 ms (depending on bus cycle time) Watchdog within 0.5 s the device goes in safe state, e.g. after loss of communication Indicators/settings LED indication LED green: supply LED red: line fault , communication error red flashing Coding optional mechanical coding via front socket Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Conformity Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Environmental test EN 60068-2-14 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Damaging gas EN 60068-2-42 Relative humidity EN 60068-2-56 Ambient conditions Relative humidity 95 % non-condensing Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 (module) , a separate housing is required acc. to the system description Connection removable front connector with screw flange (accessory) Mass approx. 750 g Dimensions 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) Data for application in connection with hazardous areas EU-type examination certificate PTB 97 ATEX 1074 U Marking 1 II 2 G Ex d [ib] IIC Gb
1 II (2) D [Ex ib Db] IIIC
Digital Output with Shutdown Input FB6208B Release date: 2021-11-28 Date of issue: 2021-11-29 Filename: 542111_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Current Io 13.5 mA Power Po 376 mW (characteristic curve rectangular type) Galvanic isolation Output/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-11:2012 International approvals ATEX approval PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U General information System information The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Assembly Front view LED green: Power supply LED red: Line fault/ Communication error Socket for removable plug blue (accessory) Space for labelling Accessories FB9224* Field Unit FB9225* FB9248* Digital Output with Shutdown Input FB6208B Release date: 2021-11-28 Date of issue: 2021-11-29 Filename: 542111_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091