Digital Output with Position Feedback FB2217E3 < 1-channel < 1 digital output, 2 digital inputs < Inputs and output Ex ia < Installation in suitable enclosures in Zone 1 < Module can be exchanged under voltage (hot swap) < Line fault detection switched on and off < Positive or negative logic selectable < Simulation mode for service operations (forcing) < Permanently self-monitoring < Output with watchdog < Output with bus-independent safety shutdown input Function The digital output features 1 output with 2 feedback inputs. The device can be used to switch solenoids, sounders, or indicators (without line fault detection) in the field. Furthermore, the device accepts digital input signals of NAMUR sensors or mechanical contacts from the field. The output can be switched off via a contact. This can be used for bus-independent safety applications. Open and short circuit line faults are detected in on and off state. The intrinsically safe inputs and the output are galvanically isolated from the bus and the power supply. Connection Zone 1 Zone 0, 20 COM I II 10 kΩ 1.5 kΩ 10 kΩ 1.5 kΩ Technical Data Slots Occupied slots 1 Supply Connection backplane bus / booster terminals Rated voltage Ur Use only in connection with the power supplies FB92** Power dissipation 1.3 W Power consumption 1.85 W Internal bus Connection backplane bus Release date: 2021-12--
01 Date of
Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 282276_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Interface manufacturer-specific bus to standard com unit Digital input Number of channels 2 Sensor interface Connection NAMUR sensor Connection [2] volt-free contact Connection channel I: 2+, 5-; channel II: 3+, 6- Rated values acc. to EN 60947-5-6 (NAMUR) Internal resistor Ri 1 kΩ Line fault detection can be switched on/off for each channel via configuration tool Connection mechanical switch with additional resistors (see connection diagram) proximity switches without additional wiring Short-circuit < 360 Ω Open-circuit < 0.35 mA Minimum pulse duration 1 ms Digital output Number of channels 1 Suitable field devices Field device Solenoid Valve Field device [2] audible alarm Field device [3] visual alarm Connection channel I: 1+, 4- Open loop voltage Us 16.5 V Current limit Imax 50 mA Internal resistor Ri 131 Ω Line fault detection can be switched on/off for each channel via configuration tool , also when turned off (every 2.5 s the valve is turned on for 2 ms) Short-circuit < 50 Ω Open-circuit > 10 kΩ Response time 10 ms (depending on bus cycle time) Watchdog within 0.5 s the device goes in safe state, e.g. after loss of communication Indicators/settings LED indication Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (O: output, I1: input 1, I2: input 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Coding optional mechanical coding via front socket Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1 Conformity Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Environmental test EN 60068-2-14 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Damaging gas EN 60068-2-42 Relative humidity EN 60068-2-56 Ambient conditions Relative humidity 95 % non-condensing Digital Output with Position Feedback FB2217E3 Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 282276_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 (module) , a separate housing is required acc. to the system description Connection removable front connector with screw flange (accessory) Mass approx. 750 g Dimensions 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch) Data for application in connection with hazardous areas EU-type examination certificate Presafe 19 ATEX 14054U Marking 1 II 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Input Voltage Uo 10 V Current Io 13 mA Power Po 33 mW (linear characteristic) Internal capacitance Ci 1.2 nF Internal inductance Li 0 mH Output Voltage Uo 17.8 V Current Io 162 mA Power Po 721 mW Internal capacitance Ci 12 nF Internal inductance Li 0 mH Galvanic isolation Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V Output/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN 60079-0:2012+A11:2013 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015 EN 60079-11:2012 International approvals ATEX approval Presafe 19 ATEX 14054U IECEx approval IECEx PRE 19.0009U Approved for Ex db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I General information System information The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Digital Output with Position Feedback FB2217E3 Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 282276_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
P O I Front view Power LED green Diagnosis LED red/white Socket for removable plug blue (accessory) Status LED red/yellow Output Status LED red/yellow Input 1 Status LED red/yellow Input 2 Digital Output with Position Feedback FB2217E3 Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 282276_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091
Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 282276_eng.pdf FB2217E3 Germany: +49 621 776 2222Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091 Digital Output with Position Feedback Characteristic Curve Load calculation Output characteristics Us Imax Rload Ie Ue Rload = Field loop resistance Us Ie U (V) I (mA) Ri Imax Ue = Us - Ri x Ie Ie = Us/(Ri + Rload)