FA1 CARLOGAVAZZI | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
Specifications are subject to change without notice (28.08.2015) 1 Product Description FA1 series amplifier is a fiber optic amplifier most suitable to be used with FUR/FUT fib- ers to achieve various detec- tion distance. FA1 has a 2 x 4 digits LED display to show the sig - nal level and threshold respectively. Display direction can be inverted to suit differ- ent installation needs. FA1 is also equipped with a 3-ways adjuster switch to adjust sensitivity and different response time. The sensor output is either NPN or PNP and is select - able to be light on or dark on. There is also a timer for the output which can be selected to be on delay, off delay, on one shot and off one shot to suit most applications’ needs.
- Distance range is fiber dependent Please see the FUR, FUT datasheet
- Easy set-up using 3-ways adjustment switch
- 2 X 4 digits display to show signal level and threshold
- Display direction can be inverted to suit different mounting
- Output 100mA NPN or PNP
- Light on and dark on switching selectable
- Operational voltage 12 to 24 VDC
- On, off, on one shot, off one shot delay timer
- Response time 200, 500, 1000, 5000µS Fiber Optic Sensor Amplifier Type FA1 Type Selection Housing Ordering no. Ordering no. W x H x D NPN PNP Light on or dark on switching Light on or dark on switching 10 x 33 x 80 mm FA1-N FA1-P Ordering Key Type Series Output Specifications Rated operating distance (Sn) Fiber dependant Please see FUR, FUT datasheet Sensitivity Increase or decrease by 3-ways adjuster switch. Switch left/right to +/- and press down to confirm Sensitivity Range Depends on selected response time 27-3991 @200µs 27-3982 @500µs 27-9988 @1000µs 27-9990 @5000µs Temperature drift < 0.2%/C° Hysteresis (H) ≤ 20% of sensing distance Rated operational volt. (UB ) 12 to 24 VDC Ripple (Urpp ) ≤ 10% Output current Continuous (Ie) 100 mA Output function NPN or PNP Light on or dark on Selected via switch Timer Type On, off, on one shot, off one shot Range 0-9999 ms Current consumption (Io) < 40 mA @ 24 VDC Voltage drop (Ud ) FA1-N ≤1V (100 mA Load) FA1-P ≤1.5V (100 mA Load) Protection Short-circuit, reverse pola- rity, transients Light source Red LED 660 nm Ambient light Incandescent light 10’000 Lux Sunlight 20’000 Lux Operating frequency Max. 2.5 kHz Response time Selectable 200, 500, 1000, 5000µs FA 1-N
2 Specifications are subject to change without notice (28.08.2015) Wiring Diagram LED and Operation Panel Power ON delay (tv) < 150 ms Indication Output Red LED Sensitivity 2 X 4 digits display Red – signal level Green - threshold Temperature Operating 0° to +60°C (32° to +140°F) Housing material Body ABS Connection Cable PVC, black, 2m, 3 wires Weight Approx. 65g Approvals CE, cULus (UL508) Environment Degree of protection IP40 Dimensions FA1 Operation Diagram T T T T Input L. on ON delay OFF delay ON one shot OFF one shot Specifications (cont.) + - OUT L.on D.on FUN. SETRun ADJ 9999 9999 Red: signal level Output indicator Green: threshold L.on/D.on switchOperation panel 33 31.5 79.35 36.518.5 3.8 72 11 Ø4.2 2M Cable Receiver Emitter DC12-24V DC12-24V NPN output PNP output Brown Black Blue Brown Black Blue NPN PNP + - OUT L.on D.on FUN. SETRun ADJ 9999 9999 Mode switch Adjustment switch / Push down confirm button
Specifications are subject to change without notice (28.08.2015) 3 FA1 Programming Functions Block Diagram - Programming Settings Settings Mode switch: Select FUN. Response speed Press ADJ for 2 sec. Turn to '+' to increase or '-' to decrease response time Press ADJ for 2 sec. Return to RUN Setting delay time: 0-9999 ms ON delay OFF delay ON one shot OFF one shot Turn to ‘+’ to increase or ‘-’ to decrease delay time Press ADJ for 2 sec. Return to RUN Inverted display Press ADJ for 2 sec. Turn to '+' to increase or '-' to change between displays Press ADJ for 2 sec. Return to RUN Factory default Press ADJ for 2 sec. Turn to '+' to increase or '-' to change between options (Yes/No) Press ADJ for 2 sec. Return to RUN FUN. RUN SET FUN. RUN SET FUN. RUN SET FUN. RUN SET FUN. RUN SET rESP SPd 200 u 5 500 u 5 9999 0 On dEL d ιSP rEad d ιSP 1234 d ιSP 1234 fct y d EF no he2i dS' p yes OFF dEL On ISht OFF ISht 1000 u 5 5000 u 5 Higher response time: shorter sensing distance. Lower response time: longer sensing distance. FUN. RUN SET FUN. RUN SET FUN. RUN SET FUN. RUN SET FUN. RUN SET Response speed ON delay OFF delay ON one shot OFF one shot Inverted display Factory default Response speed 200 µs 500 µs 1000 µs 5000 µs 0 ms No Not inverted Yes Inverted 9999 ms
4 Specifications are subject to change without notice (28.08.2015) Diffuse model settings 1. Set to L.on 2. Select SET 3. With target: hold down ADJ for 2 sec. Auto-teach- in function is performed when the blinking stops. (see fig. 1, p. 5) 4. Return to RUN 5. If reversed operation detection is required, change to D.on Through-beam model settings 1. Set to D.on 2. Select SET 3. Without target; hold down ADJ for 2 sec. Auto-teach function is performed when the blinking stops. (see fig. 3, p. 5) 4. Return to RUN 5. If reversed operation detection is required, change to L.on Programming Functions - Example Setting example Set OFF delay to 2 sec. 1. Select FUN. 2. Turn to '+' to or '-' to go to OFF delay mode 3. Hold down for two sec. The display shows '0' 4. Turn to '+' to set to 2000 5. Hold down for two sec. to confirm setting (OFF delay) 6. Return to RUN Working position is now: FUN. RUN SET FUN. RUN SET FUN. RUN SET FUN. RUN SET FUN. RUN SET delt 0 0 2000 delt 2000 OFF dEL ADJ ADJ ADJ L.on D.on L.on D.on L.on D.on L.on D.on 2 s2 s2 s2 s Input Output L. on mode D. on mode FUN. RUN SET OFF dEL OFF delay 2 sec. ADJ
Specifications are subject to change without notice (28.08.2015) 5 Delivery Contents
- Amplifier: FA1...
- Installation manual
- Packaging: Cardboard box Installation Hints Accessories
- Fiber optic plastic type FUR, FUT For further information refer to Fiber Optic Plastic Type FUR, FUT datasheets. 1. Open the protective cover. Open the protective cover and tip the fiber lock lever to unlock. Remove the cables by pulling them straight out of the mounting holes. Insert the fiber cables Remove the fiber cables 2. Tip the fiber lock lever to unlock. 3. Insert the fiber cables into the mounting holes until the limit. Insertion depth 12 mm. 4. Pull the fiber lock lever back to lock the cables. 5. Close the protective cover Pull out Unlock mode Lock mode Insert Mount each amplifier to the attached mounting bracket or DIN rail in sequence. Mounting the amplifier NB: Do not detach two amplifiers at a time. Detach the amplifiers in sequence by sliding the amplifier bodies. Diffuse model settings Through-beam model settings Fig. 1 Fig. 3 Fig. 2 Fig. 4 Detect ON White target White target Dark Dark With target With target Without target Without target Detect OFF Claw tenon DIN rail Detaching the amplifier Detach the amplifier,