F02 XPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
01 02 03 04 05 06 07 08 09 0 100 Input Voltage (%) Output Voltage (%) Output Voltage vs. Input Voltage Full-load No-load 4722AV03 PAGE 1 WWW.XPPOWER.COM 200V to 8kV at 10W PRODUCT DESCRIPTION Proven Reliability MODEL OUTPUT VOLTAGE*2 OUTPUT CURRENT*1 F02 0 to 200V 50 mA F03 0 to 300V 33.3 mA F04 0 to 400V 25 mA F05 0 to 500V 20 mA F06 0 to 600V 16 mA F08 0 to 800V 12.5 mA F10 0 to 1kV 10 mA F12 0 to 1.2kV 8.3 mA F15 0 to 1.5kV 6.6 mA F20 0 to 2kV 5 mA F30 0 to 3kV 3.3 mA F40 0 to 4kV 2.5 mA F50 0 to 5kV 2 mA F60 0 to 6kV 1.66 mA F70 0 to 7kV 1.5 mA F80 0 to 8kV 1.25 mA F SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS
APPLICATIONS
FEATURES
- Proportional Input/Output
- Compact, PCB Mount Package
- Metal Case / Shielded Transformer
- Short Circuit Protection
- Low Ripple, Low EMI / RFI
- Proven Reliability
- Input/Output Isolation
- Low Leakage Current
- Low Input/Output Coupling Capacitance
- No External Components Required
- No Minimum Load Required
- MTBF: >810K hrs per Bellcore TR-332
- RoHS Compliant
- Electrophoresis
- Capacitor Charging
- Piezo Devices
- Field Generation
- Grid Bias
- Mass Spectrometry
- Electrostatic Chuck
- Igniter / Spark Module
- Sustaining Ion Pumps
- Dual output (Center Tap) Models Available (CT Suffix)
- Mounting Holes (F02 thru F60 only)(H Suffix) The F Series is a broad line of robust, field-proven DC to HV DC converters which deliver 10 Watts continuous output power. Outputs range from 200V to 8kV. The input and output are galvanically isolated so a unit can be used to deliver a positive or negative high-voltage. The output voltage is proportional to input voltage with a low 0.7V typical turn-on voltage. The F Series employs EMCO’s quasi-sinewave oscillator, a fully enclosed transformer, input and output filtering, and a 5-sided metal enclosure. As a result, these modules exhibit very low EMI/RFI, noise and ripple. A dual output option with center-tap pin which, when grounded provides both positive and negative outputs from one compact module.
CURRENT RIPPLE*4 REVERSIBLE MODEL OUTPUT VOLTAGE DUAL OUTPUT (CENTER TAP) MODEL OUTPUT VOLTAGE F02/F02CT 0 to 12V 50mA <1.0% F02 0 to 200V F02CT 0 to +/- 100V F03/F03CT 0 to 12V 33.3mA <1.0% F03 0 to 300V F03CT 0 to +/- 150V F04/F04CT 0 to 12V 25mA <1.0% F04 0 to 400V F04CT 0 to +/- 200V F05/F05CT 0 to 12V 20mA <0.1% F05 0 to 500V F05CT 0 to +/- 250V F06/F06CT 0 to 12V 16mA <0.1% F06 0 to 600V F06CT 0 to +/- 300V F08/F08CT 0 to 12V 12.5mA <0.1% F08 0 to 800V F08CT 0 to +/- 400V F10/F10CT 0 to 12V 10mA <0.1% F10 0 to 1kV F10CT 0 to +/- 500V F12/F12CT 0 to 12V 8.3mA <0.1% F12 0 to 1.2kV F12CT 0 to +/- 600V F15/F15CT 0 to 12V 6.6mA <0.1% F15 0 to 1.5kV F15CT 0 to +/- 750V F20/F20CT 0 to 12V 5mA <1.0% F20 0 to 2kV F20CT 0 to +/- 1kV F30/F30CT 0 to 15V 3.3mA <1.0% F30 0 to 3kV F30CT 0 to +/- 1.5kV F40/F40CT 0 to 15V 2.5mA <1.0% F40 0 to 4kV F40CT 0 to +/- 2kV F50/F50CT 0 to 15V 2mA <1.0% F50 0 to 5kV F50CT 0 to +/- 2.5kV F60/F60CT 0 to 15V 1.66mA <1.0% F60 0 to 6kV F60CT 0 to +/- 3kV F70/F70CT 0 to 15V 1.5mA <2.5% F70 0 to 7kV F70CT 0 to +/- 3.5kV F80/F80CT 0 to 15V 1.25mA <2.5% F80 0 to 8kV F80CT 0 to +/- 4kV 4722AV03 PAGE 2 WWW.XPPOWER.COM F SERIES ELECTRICAL SPECIFICATIONS*2
WWW.XPPOWER.COM PARAMETER VALUE INPUT VOLTAGE
0 TO 12V (F02 TO F20)
0 TO 15V (F30 TO F80)
TURN-ON VOLTAGE <0.7V INPUT CURRENT <500MA, NO LOAD <1.5A, FULL LOAD ISOLATION < +/-3.5kV BIAS (F02 TO F60) < +/-500V BIAS (F70 TO F80) INPUT CAPACITANCE ~240uF RESPONSE TIME 260 ms (typical) OUTPUT VOLTAGE TOLERANCE +/-5% (Full Load, 100% output voltage) FREQUENCY 25 kHz TO 125 kHz OPERATING TEMPERATURE*5 -10C to +70C (Case) STORAGE TEMPERATURE -25C to +90C F-SERIES ELECTRICAL SPECIFICATIONS*3 F SERIES Rectifier & Multiplier Transformer Oscillator (+) Output Center tap (for Dual output option) (-) Output (+) In (-) In BLOCK DIAGRAM HOT SPOT CASE TEMPERATURE POINT DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
WWW.XPPOWER.COM F SERIES MECHANICAL SPECIFICATIONS F02-F60 PIN # FUNCTION 1 (+) Input 2 (-) Input 3 (+) Output 4 (-) Output
5 Dual Output/Center Tap (optional)
WEIGHT <5 OZ (142 GRAMS) VOLUME 4.0 cu. In. (66.3 cc) CASE MATERIAL Black Anodized Aluminum #4/M3 CLEARANCE 2 4 1 3 BOTTOM VIEW 2 HOLES. MTG HOLE (OPTIONAL) 2.80 (71.1)0.20 (5.1) 0.85 (21.6) 0.20 (5.1) 0.800 (20.32) (0.85) (21.6) 1.200 (30.48) 0.35 (8.9) 0.500 (12.70) 0.20 (5.1) 2.400 (60.96) PC PINS 0.031 (0.79) 0.45 (11.4) 1.000 (25.40) 1.70 (43.2) PCB LAYOUT COMPONENT SIDE 2 4 1.750 (44.45) 0.650 (16.51) 0.250 (6.35) 0.100 (2.54) 0.400 (10.16) 0.900 (22.86) 0.800 (20.32) 1.050 (26.67) LOCATION OF MTG. HOLES (OPTIONAL) 0.140 (3.56) 2PL 1.200 (30.48) HIGH VOLTAGE TOP VIEW 1.300 (33.02) TOP VIEW RECOMMENDED HOLE & PAD O.D. SIZE: *5 PLACES OPTIONAL DUAL OUTPUT (CENTER TAP) Ø Ø Ø NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT. DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
WWW.XPPOWER.COM F SERIES MECHANICAL SPECIFICATIONS F70-F80 PARAMETER VALUE WEIGHT <5 OZ (142 GRAMS) VOLUME 4.5 cu. In. (74.1cc) CASE MATERIAL Black Anodized Aluminum PIN # FUNCTION 1 (+) Input 2 (-) Input 3 (+) Output 4 (-) Output 6.00" (152.4mm) #22 AWG, 30KV OUTPUT LEADS: SILICONE MINIMUM LENGTH. 2 PLACES. 2 4 RECOMMENDED HOLE & PAD SIZE:
3 PLACES
Ø0.250 (6.35) CLEARANCE FOR 0.215" (5.46mm) O.D. OUTPUT LEADS
2 PLACES
0.85 (21.6) 0.400 (10.16) 1.400 (35.56) TOP VIEW 2.80 (71.1) 1.70 (43.2) MIN 0.25 (6.4) 0.95 (24.1) PC PINS Ø0.040 (1.02) 0.800 (20.32) 0.45 (11.4) 1.200 (30.48) 1.30 (33.0) .25 (6.4) HIGH VOLTAGE Ø .140 (3.56) MTG HOLES, 2X #4/M3 CLEARANCE RECOMMENDED PCB LAYOUT TOP VIEW OPTIONAL DUAL OUTPUT (CENTER TAP) NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT. DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
WWW.XPPOWER.COM OPTION CODE TABLE F SERIES * Notes: 1. At maximum rated output voltage. 2. Output voltage is load dependent. Under light or no load conditions, reduce input voltage so maximum rated output voltage is not exceeded. 3. Specifications after 1 hour warm up, full load, at 25C unless otherwise indicated. 4. Ripple specification for dual output units applies to the voltage between the positive and negative output terminals. 5. Proper thermal management techniques are required to maintain safe case temperature at maximum power output XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details. HOW TO ORDER Model Output Voltage (See table) EXAMPLE: F30CTH (F-Model, 30-Output Voltage, CT-Center Tap, H-Holes) PART NUMBER SELECTOR: Model Number: F30CTH Mounting Holes (optional) Center Tap (for dual output option) OPTION ORDER CODE MODELS POLARITY Positive / Negative reversible Blank ALL Dual Output (center tap) option CT ALL OPTIONS ROHS R ALL Mounting Holes H UP TO 6KV