F200 CHAUVINARNOUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 8
Technical content
AC, DC and AC+DC TRMS Clamp Multimeters
- Current: 2,000 A AC / 3,000 A DC
- Voltage: 1,000 V AC/DC
- Clamping diameter: 60 mm
- Large 10,000-count display
- Automatic AC / DC detection
- Min, Max, Peak
- RELative and diff erential measurements
- Power values
- THD & Harmonics
- For electricians, clamp multimeters are ideal tools for any work in the fi eld. Simple to use, they off er all the necessary functions in a single, compact solution.
- Th e F200 Series meets the needs of self- employed electricians and small and medium-sized business and industries in the electrical sector.
- For medium and high-power work, the F400 and F600 Series provide maximum safety whatever the measurement conditions and type of installation.
- With its large clamping diameter and current measurements up to 3,000 A, the F600 Series is perfect for working on electrical power distribution and transmission applications. All these clamp multimeters are equipped with automatic AC/DC detection. Each key corresponds to a single function whatever the mode. CAT egory IV up to 1,000 V for greater safety. /T_h e casing is equipped with a shockproof band to protect against falls. /T_h e backlit LCD screen is particularly comfortable to read, off ering contrasts and a viewing angle which are unprecedented for this type of instrument (up to 10,000/uni00A0counts). /T_h e rotary switch is /f_i tted with special moulding for excellent grip even with protective gloves. Various clamping diameters up to 60/uni00A0mm are available to ensure comfortable measurements. Th e whole range has been designed for one-handed use, even when wearing protective gloves. For maximum effi ciency, each type of measurement has its own specifi c switch position. Th e "1 key, 1 function″ concept makes it even simpler to use. In addition, all these clamps are equipped with automatic detection of the type of signal (AC or DC) for current, voltage and power measurements. Ergonomics All the clamps in the F200, F400 and F600 Series benefi t from a fast 12-bit TRMS digital acquisition system off ering high measurement accuracy. Th anks to their large bandwidth and high crest factor, these clamps provide accurate measurements whatever the type of signal. Performance 1,000 V CAT IV, an unprecedented level of safety for clamp multimeters! Users can be sure of working in total safety and in compliance with the applicable standards. Th e instruments’ IP54 protection safeguards them against dust, in particular, thus guaranteeing that safety is maintained over time. Th e mechanical design of these clamps enables them to pass the standard test for falls from a height of 2 metres. Safe and Robust
Th e Quality of TRMS Measurements, Whatever the Type of Signal TRMS Version of Min and Max! Th e Min and Max are TRMS values calculated over a duration of up to 100 ms. Th is feature is particularly useful for sizing an installation, the diameter of a power cable, a thermal protection device, etc. Peak+ and Peak- Calculated over a period of 1 ms, the Peak+ and Peak- values help to characterize the distortion aff ecting the signal measured. For example, they may reveal variations in the installation’s behaviour or even malfunctions. THD and Harmonics When seeking the causes of a malfunction, knowledge of the overall signal distortion (THDr or THDf) or frequential distortion (harmonic analysis) helps you to identify the precise corrective solution required: fi ltering, oversizing, etc. Harmonic analysis also contributes to fi re prevention. ∆REL, for Quick Evaluation Comparison with a reference quantity is a quick way of evaluating and analysing your results. A signal’s variations can be measured diff erentially or relatively. Th e fi rst method indicates the diff erence between the value of reference and the value measured. Th e second method indicates the proportion. Th e ∆REL function can be applied to any type of measurement and can be used jointly with the Min, Max and Peak functions. INNOVA TION FROM CHAUVIN ARNOUX Th e function makes it easy to analyse both the inrush of a single motor and the inrush of a set of machines in operation. Th e clamp automatically determines the type of signal and the level of current in the installation and then adapts the algorithm and measurement mode to capture the expected overcurrent. Indeed, correct sizing of electrical installations in terms of both the conductors and the protective systems implemented is a recurrent problem. Overcurrents usually occur when an installation or a machine is started up or when machinery is subjected to heavy loads. Th e function enables you to size the installation correctly. A range off ering unprecedented analytical and diagnostic functions!
Th e Adapter function helps to extend the instrument’s possibilities through the use of measurement probes (luxmeter, Infrared temperature sensor, tachometer, etc.) with voltage output (AC or DC). A cleverly-designed system allows users to read the quantity measured directly. Th is 10-model range of clamp multimeters meets all your needs in the fi eld. 1/ MEASUREMENT RANGE 3 series identifi able by their fi rst digit for 3 measurement ranges
- Th e F200 Series for currents up to 600 AAC / 900 ADC
- Th e F400 Series for average currents up to 1,000 AAC / 1,500 ADC
- Th e F600 Series for high currents up to 2,000 AAC / 3,000 ADC All the models also innovate by proposing as standard features:
- AC and DC voltage measurement up to 1,000 V
- Resistance and audible continuity
- Min / Max analysis
- Min / Max analysis overcurrent measurement 2/ TYPE CURRENT & FUNCTIONS Each series comprises 3 or 4 models. Th e last digit in each clamp’s name corresponds to diff erent applications and levels of analysis. So the F203, F403 and F603 clamps, for example, off er the same functions but with diff erent measurement ranges. Voltage up to 1,000 V Resistance, audible continuity F201 / F401 AC Applications All the basics for mains-powered installations and equipment. F203 / F403 / F603 "AC or DC" Applications DC current T emperature Adapter function ∆REL Phase rotation T o determine the phase order, a "2-wire" microprocessor-based measurement system avoids the constraints and faults linked to instruments equipped with resistive or capacitive technologies when using protective accessories (gloves, mats, etc.) or isolating transformers. F205 / F405 / F605 "Mixed AC+DC" Applications + T esting & Maintenance Power values THD ∆REL Min/Max/Peak Phase rotation Ripple Th e ripple is a parameter that enables you to assess the quality of the smoothing on currents which are rectifi ed and then smoothed. Th e lower the ripple factor, the greater the effi ciency of the smoothing. If switching power supplies are involved, the voltage supplied includes residual ripple, particularly at high frequency. Th is ripple is harmful for electronic equipment, so it should be kept to a minimum. F407 / F607 "Mixed AC+DC" Applications + Analysis & Surveys Power values Harmonics Ripple Recording PC soft ware F200
600 AAC / 900 ADC
1,000 AAC / 1,500 ADC F600 2,000 AAC / 3,000 ADC Choose Your Clamp Multimeter/uni2009 Choose Your Clamp Multimeter/uni2009 Choose Your Clamp Multimeter/uni2009
Th e F200 clamps are ideal for low-power or medium-power low-voltage applications: maintenance of tertiary or industrial electrical installations or installed machines, power supply diagnostics and/or sizing, commissioning of air-conditioning and heating systems, work on electric vehicles, etc. F201 F203 F205 Display resolution 6,000 cts 6,000 cts 6,000 cts Measurements displayed x 1 x 1 x 1 Display backlighting ● ● Acquisition method TRMS TRMS TRMS Automatic AC/DC detection ● ● ● AC ● ● ● A DC ● ● AC+DC ● AC ● ● ● V DC ● ● ● AC+DC ● Hz ● ● ● Resistance/audible continuity ● ● ● T emperature (°C / °F) ● ● Adapter function ● 2-wire phase rotation ● W, var, VA, PF ● THDf / THDr ● Min. / Max. ● ● ● Peak+ / Peak- ● True InRush ● ● ● ∆REL ● ● F200 serie Clamping diam. 34 mm Current 600 A AC or AC+DC
900 ADC
of use 1,000 V CAT III Complete display of F200 Series models F200 F200 F200 F200 F200 F200 SERIE SERIE SERIE SERIE SERIE SERIE
Th e F400 Series is designed for medium-power low-voltage applications in sectors such as LV electricity production and distribution, industry, railways, etc. It is also suitable for lift /elevator technicians and other lift ing and transport specialists. Th e main applications for the clamps in this series are maintenance, testing, monitoring, diagnostics and connection. F401 F403/F603 F405/F605 F407/F607 Display resolution 10,000 cts 10,000 cts 10,000 cts 10,000 cts Measurements displayed x 1 x 1 x 1 x 3 Display backlighting ● ● ● ● Acquisition method TRMS TRMS TRMS TRMS Automatic AC/DC detection ● ● ● ● AC ● ● ● ● A DC ● ● ● AC+DC ● ● AC ● ● ● ● V DC ● ● ● ● AC+DC ● ● Hz ● ● ● ● Resistance/audible continuity ● ● ● ● T° (°C / °F) ● ● Adapter function ● 2-wire phase rotation ● W, var, VA, PF ● ● DPF ● THDf / THDr ● ● Harm0… Harm25 ● Min. / Max. ● ● ● ● Peak+ / Peak- ● ● True InRush ● ● ● ● ∆REL ● ● Recording ● PC soft ware (included) / Bluetooth ● F400 F400 F400 SERIE SERIE SERIE F400 serie Clamping diam. 48 mm Current 1,000 A AC or AC+DC 1,500 ADC Domain 1,000V CAT IV of use 1,000 V CAT III Complete display for F401, F403, F405, F603 & F605
RECS3Φ %THDf THDr % RIPPLE PFCF DPF MAX+ PEAK PEAK AVG MIN kWVA kWVA kΩHz kvar DC RMS kvar DC kvar RMS Th e F600 Series is designed for the high-power LV market in sectors such as electrical power distribution, chemical and petrochemical industries, metallurgy, transport, etc. Applications: maintenance, testing, monitoring, diagnostics, sizing, connection, etc. F600 serie Clamping diam. 60 mm Current 2,000 A AC or AC+DC 3,000 ADC Domain 1,000 V CAT IV of use 1,000 V CAT III F401 F403/F603 F405/F605 F407/F607 Display resolution 10,000 cts 10,000 cts 10,000 cts 10,000 cts Measurements displayed x 1 x 1 x 1 x 3 Display backlighting ● ● ● ● Acquisition method TRMS TRMS TRMS TRMS Automatic AC/DC detection ● ● ● ● AC ● ● ● ● A DC ● ● ● AC+DC ● ● AC ● ● ● ● V DC ● ● ● ● AC+DC ● ● Hz ● ● ● ● Resistance/audible continuity ● ● ● ● T° (°C / °F) ● ● Adapter function ● 2-wire phase rotation ● W, var, VA, PF ● ● DPF ● THDf / THDr ● ● Harm0… Harm25 ● Min. / Max. ● ● ● ● Peak+ / Peak- ● ● True InRush ● ● ● ● ∆REL ● ● Recording ● PC soft ware (included) / Bluetooth ● F600 F600 F600 F600 F600 F600 SERIE SERIE SERIE SERIE SERIE SERIE Complete display for F407 & F607
Chauvin Arnoux Middle East P .O. BOX 60-154 1241 2020 JAL EL DIB - LEBANON T el: +961 1 890 425 Fax: +961 1 890 424 camie@chauvin-arnoux.com www.chauvin-arnoux.com UNITED KINGDOM Chauvin Arnoux LTD Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk Dewsbury, West Yorkshire - WF12 7TH T el: +44 1924 460 494 Fax: +44 1924 455 328 info@chauvin-arnoux.co.uk www.chauvin-arnoux.com FRANCE Chauvin Arnoux 190, rue Championnet
75876 PARIS Cedex 18
T el: +33 1 44 85 44 38 Fax: +33 1 46 27 95 59 export@chauvin-arnoux.fr www.chauvin-arnoux.com 2 3 TO ORDER For assistance and ordering 906211592 – Ed. 1 – 04/2019 – Non contractual document. Confirm specifications before ordering. 1.5 V for F400 / F600 Series x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 2 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 + Start-up Guide and Operating Manual (5 languages) on CD-Rom STATE AT DELIVERY F201 F203 F401 F603 F403 F205 F605 F405 F407 F607
9 V for F200 Series
F200 SERIES F400 SERIES F600 SERIES Model F201 F203 F205 F401 F403 F405 F407 F603 F605 F607 Clamping diameter 34 mm 48 mm 60 mm Display LCD Backlit LCD Backlit LCD Backlit LCD Resolution 6,000 counts 10,000 counts 10,000 counts Number of values displayed 1 1 3 1 3 Type of acquisition TRMS [AC] TRMS [AC]/DC TRMS [AC, AC+DC]/DC TRMS [AC] TRMS [AC]/DC TRMS [AC, AC+DC]/DC TRMS [AC]/DC TRMS [AC, AC+DC]/DC Autorange Yes Yes Yes Automatic AC / DC detection - Yes - Yes Yes A AC 0.25 to 600 A (900 A peak) 0.25 to 1,000 A (1,500 A peak) 0.25 to 2,000 A (3,000 A peak) A DC - 0.25 to 900 A - 0.25 to 1500 A 0.25 to 3,000 A A AC+DC - 0.25 to 600 A (900 A peak) - 0.25 to 1,000 A (1,500 A peak) - 0.25 to 2,000 A (3,000 A peak) Best accuracy 1 % L. + 3 cts 1 % L. + 3 cts 1 % L. + 3 cts V AC 0.15 to 1,000 V 0.15 to 1,000 V 0.15 to 1,000 V V DC 0.15 to 1,000 V 0.15 to 1,000 V 0.15 to 1,000 V V AC+DC - 0.15 to 1,000 V - 0.15 to 1,000 V - 0.15 to 1,000 V Best accuracy - 1 % reading + 3 cts - 1 % reading + 3 cts - 1 % reading + 3 cts Hz Current: 5.0 Hz to 3,000 Hz Voltage: 5.0 Hz to 20.00 kHz Current: 5.0 Hz to 2,000 Hz Voltage: 5.0 Hz to 20.00 kHz Current: 5,0 Hz to 1,000 Hz Voltage: 5,0 Hz to 20.00 kHz Open-circuit voltage ≤ 8 V ≤ 8 V ≤ 8 V Measurement current ≤ 680 µA ≤ 680 µA ≤ 680 µA Audible continuity Yes Yes Yes Continuity threshold adjustable from 1 to 599 Ω adjustable from 1 to 999 Ω 40 Ω adjustable from 1 to 999 Ω 40 Ω Diode test (semiconductor junction) Yes Yes No Yes No T emperature (K type) °C: -60.0 to +1,000.0 °C Single-phase and total three-phase power values Yes Yes Yes Active power - 1 W to 600 kW - 1 W to 1,000 kW - 1 W to 2,000 kW Reactive power - 1 var to 600 kvar - 1 var to 1,000 kvar - 1 var to 2,000 kvar Apparent power - 1 VA to 600 kVA - 1 VA to 1,000 kVA - 1 VA to 2,000 kVA FP / DPF - Yes / No - Yes / No Yes / Yes - Yes / No Yes / Yes Harmonic analysis - Yes - Yes Yes - Yes Yes THDf / THDr - Yes / Yes - Yes / Yes Yes / Yes - Yes / Yes Yes / Yes Frequency analysis - No - No 25th order - No 25th order Phase rotation (2-wire method) - Yes - Yes - - Yes - Functions True InRush (Overcurrent measurement) Yes Yes Yes Motor inrush Yes Yes Yes Load change Yes Yes Yes Hold Yes Yes Yes Min. / Max. Yes Yes Yes Peak+ / Peak- - Yes - Yes Yes RELative ∆X / Differential ∆X/X (%) - Yes / Yes - Yes / Yes - Yes / Yes - Auto Power Off Yes Yes Yes Data recording - - Yes - Yes Communication interface - - Bluetooth - Bluetooth Electrical safety as per IEC 61010 600 V CAT IV 1,000 V CAT IV & CAT III 1,000 V CAT IV & CAT III Power supply 1 x 9 V LF22 4 x 1.5 V AA 4 x 1.5 V AA Dimensions & weight 78 x 222 x 42 mm / 340 g 92 x 272 x 41 mm / 600 g 111 x 296 x 41 mm / 640 g