Technical content

ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals ETA-USA Output Voltage Voltage Adjustment Range Rise Time Vdc Output Current A Ripple and Noise mVp MODEL/CHANNEL Unit

FEATURES

(Single) ETP-SC ETP24- SC300 Line Regulation Load Regulation Temp. Coefficient Drift mV mVp mV mV Over Current Protection A Over Voltage Protection Safety

  • Light weight, compact size
  • High efficiency, high reliability
  • Over voltage and over current protection
  • 95.5% Efficiency Remote Sense Remote Control Ref. MTBF Efficiency % Input Voltage Range - INPUT Input Voltage V DC300 DC200 to 400 95.5 ±10% of rated output voltage (at output connector) 340 120 135 4.8 9.6 500mS (maximum) Available (with load line form output terminal, connect + and - sensing terminals to + and - terminals of load line, respectively) Available UL60950-1, CSA60950-1, EN60950-1 certified CE (LV directive) compliant 208,000 Operate at 115% (minimum) of the rated voltage Turn on at least 1 minute after the input voltage shutdown to restart Operate at 105% (minimum) of the rated current, constant current drop, automatic recovery after removing overload. Output shuts down when output voltage drops to around 5V. Turn on at least 1 minute after the input voltage shutdown to restart

Size(WxHxD) / Weight Operating Temperature Operating Humidity Storage Temperature Storage Humidity Withstand Voltage Vibration 450W Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals 450W Primary-Frame Ground Secondary-Frame Ground Isolation Resistance Primary - Secondary - Case Shock Ref. Frequency mm/g Block Diagram Temperature Derating Curve ETA-USA ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com -10 to +71 °C without thermal shock ( see output derating table) 20 to 90%RH (non-condensing) -20 to +85°C without thermal shock 10 to 90%RH (non-condensing) AC3000V for 1 minute without defect, faradic current=10mA 100MΩ (minimum) by DC500V insulation tester 5 to 10Hz: 10mm double amplitude, 10 to 55Hz: acceleration 19.6m/s^2 20 minute cycle for 60 minutes each along X, Y, Z axes Impact force 196m/s^2 160 SwitchingNoise filter Output voltage sensing OCP sensing Control Sensing OVP sensing Switching Control Rectifying Rectifying RectifyingRectifying Control AC1000V for 1 minute without defect, faradic current=50mA AC2000V for 1 minute without defect, faradic current=10mA Chassis module/open-frame type / approx. 530g

Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals Output/Overcuttent Curve 450WOutput Current/Overcurrent 300/600WOutput/Overcuttent Curve 450WPlacing/Mounting Direction ETA-USA ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Output current and efficiency curve Overcurrent protection (OCP) curve

  • The power supply should be placed/mounted in either of the directions shown above.
  • When multiple power supply units are operated side by side, make sure that the temperature around each unit is within the specified operating temperature range on the specifications before using the units.

ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 Dimension Diagram (mm) Output (-) Output voltage setting VR Serial number on the side 4-M4 mounting hole, maximum depth 4mm Output (+) 3-M4 mounting hole, maximum depth 4mm Connector joint Pin No. Pin No. Pin No. Pin No. Unit Tolerance