ETG-SC ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals ETA-USA Output Voltage Voltage Adjustment Range Rise Time Vdc Output Current A Ripple and Noise mVp MODEL/CHANNEL Unit
FEATURES
(Single) ETG-SC ETG3.3- SC300 ETG12- SC300 ETG05- SC300-U1 ETG24- SC300 3.3 5 12 24 Line Regulation Load Regulation Temp. Coefficient Drift Dynamic Load Regulation mV mVp mV mV mV Over Current Protection A Over Voltage Protection Safety
- Light weight, compact size
- High efficiency, high reliability
- Over voltage and over current protection
- Isolated Power Supply Remote Sense Remote Control Ref. MTBF Efficiency % H Rated Output Power ±10% of rated output voltage 500 mS (maximum) Constant current drop, automatic recovery after removing the overload. No guarantee provided for continuous overcurrent or short-circuit status for 1 minute or longer. Constant current drop, automatic recovery after removing the overload. Output shuts down when output voltage drops to around 5V. Turn on at least 1 minute after the input voltage shutdown to restart. Turn on at least 1 minute after the input voltage shutdown to restart Available (with load line form output terminal, connect + and - sensing terminals to + and - terminals of load line, respectively) Available 185,910 2550120 120 600 340220 120 135 13548 7.53.61.50.9 396 150 600250 250 1200 94 9595 95 172,243184,195 172,243 Input Voltage Range - DC200 to 400 INPUT Input Voltage V DC300 W UL60950-1, CSA60950-1, EN60950-1 certified (5V) CE (LV directive) compliant
Size(WxHxD) / Weight Operating Temperature Operating Humidity Storage Temperature Storage Humidity Withstand Voltage Primary-Secondary Vibration 600W Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals 600W Primary-Frame Ground Secondary-Frame Ground Isolation Resistance Primary - Secondary - Case Shock Cooling (600W), Single output SwitchingNoise filter Output voltage sensing OCP sensing Control Sensing OVP sensing Switching Control Rectifying Rectifying RectifyingRectifying Control Load[%] Ambient temperature[˚C] (a) When ambient temperature goes above 50 [˚C], an output should be lowered to the degree that the derating curb shown in the left figure is satisfied (by 3.5% per degree °C when the ambient temperature is between 50 and 71 [˚C]) (b) When the ambient temperature is 50 [˚C] or below, the unit should be used under a load condition of up to 75%. When ambient temperature goes above 50 [˚C], an output should be lowered to the degree that the derating curb shown in the left figure is satisfied (by 3.5% per degree C when the ambient temperature is between 50 and 71 [˚C]) (c) If measured temperature rise of T1 copper plate, T1 input choke coil, and heatsink is up to the maximum rise specified below, the power supply unit can be operated under a load condition of 100% or below until the ambient temperature reaches to 50 [˚C]. (A measure, such as placing the unit on a surface with high heat release and using cooling fan, should be taken so that the unit is operated at or below the maximum temperature rise.) If the measured temperatures are above the maximum rise, the unit should be operated with the same derating as (b) Maximum temperature rise: T1 copper plate: temperature rise (□t) 60 [˚C] T1 coil: temperature rise (□t) 60[˚C] Heatsink; temperature rise (□t) 40 [˚C] mm/g Block Diagram Temperature Derating Curve ETA-USA ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com -10 to +71˚C without thermal shock 20 to 90% RH (non-condensing) -20 to +85˚C without thermal shock AC3000V for 1 minute without defect, faradic current=10mA
100 MΩ (minimum)
5 to 10Hz: 10mm double amplitude, 10 to 55Hz: acceleration 19.6m/s^2 20 minute cycle for 60 minutes each along X, Y, Z axes (non-operating) Impact force: 196m/s^2 Convection cooling Open-frame type / approx. 715 g 20 to 90% RH (non-condensing) AC1000V for 1 minute without defect, faradic current=100mA AC2000V for 1 minute without defect, faradic current=10mA
(300W), Single output Output current and efficiency curve Overcurrent protection (OCP) curve DC300V DC5V 25˚C Input voltage Output voltage Ambient temperature Output current[A] DC300V DC5V 25˚C Input voltage Output voltage Ambient temperature T1 coil T1 copper plate
- The power supply should be placed/mounted in either of the directions shown above.
- When multiple power supply units are operated side by side, make sure that the temperature around each unit is within the specified operating temperature range on the specifications before using the units. Placing/mounting direction 300/600W Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 The Power Professionals Output/Overcuttent Curve Output voltage[V] Heatsink 600WOutput Current/Overcurrent 300/600WOutput/Overcuttent Curve 600WPlacing/Mounting Direction ETA-USA ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com
ETA-USA16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753 Dimension Diagram (mm) Output(-) 7-M4 mounting hole Output voltage setting VR Connector joint Pin No. Pin No. Pin No. Pin No. Output(+) Serial No. (600W), Single output