DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 18

Technical content

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) 4 56789 1 0 Product Code 11 12 Design No. Series Series E8E08 E11 Series E11 Series E14 Lead Configuration E14 The first two digits are significant figures and the third one denotes the number of zeros following. Nominal Varistor Voltage Packaging Bulk Bulk Taped Taped Lead Configuration Straight Lead Crimped Lead Straight Lead Crimped Lead Symbol 1) Excluding E14, only the lead cut 2) Excluding E14 A 1) B 2) E 2) F Series E5E05 E07 Series E7 E10 Series E10 “ZNR” Transient/Surge Absorbers Type: D Series: E ■ Explanation of Part Numbers “ZNR” Transient/Surge Absorber, Series E, Type D features large surge current and energy handling capability for absorbing transient overvoltage in a compact size. ■ Handling Precautions and Minimum Quantity / Packing Unit Please see Related Information ■ Recommended Applications

  • Transistor, diode, IC, thyristor or triac semiconductor protection
  • Surge protection in consumer electronic equipment
  • Surge protection in communication, measuring or controller electronics
  • Surge protection in electronic home appliances, gas or petroleum appliances ■ Applicable Standards
  • UL1449 (VZCA2/UL, VZCA8/C-UL)
  • VDE IEC61051-1, -2, -2-2, IEC60950-1 Annex.Q
  • CQC(GB/T10193, GB/T10194, GB4943.1, GB8898) Refer to pages 2 to 3, and 19 for the details ■ Features
  • Large withstanding surge current capability in compact sizes
  • Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes
  • Wide range of varistor voltages
  • RoHS compliant Dec. 201307

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) ■ Reference Guide to Standard Products Part No. Applicable Standards Varistor Voltage at 1 mA Maximum Allowable Voltage Clamping Voltage at 8/20μs Maximum Peak Current at 8/20μs(A) Recommended Applications Type Name Approvals (V) ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times ERZE05A201 E201 ˓ˑ˖ 200 (185 to 225) 130 170 340 10 1200 600 AC 100 V Line–Line

Applications

ERZE07A201 E7201 ˓ˑ˖ 340 25 2500 1250 ERZE08A201 E8201 ˓ˑ˖ 340 25 3500 2500 ERZE10A201 E10201 ˓ˑ˖ 340 50 4500 3000 ERZE11A201 E11201 ˓˕ˑ˒˖˗ 340 50 6000 5000 ERZE14A201 E14201 ˓˕ˑ˒˖˗ 340 100 10000 7000 ERZE05A221 E221 ˓ˑ˖ 220 (198 to 242) 140 180 360 10 1200 600 ERZE07A221 E7221 ˓ˑ˖ 360 25 2500 1250 ERZE08A221 E8221 ˓ˑ˖ 360 25 3500 2500 ERZE10A221 E10221 ˓ˑ˖ 360 50 4500 3500 ERZE11A221 E11221 ˓˕ˑ˒˖˗ 360 50 6000 5000 ERZE14A221 E14221 ˓˕ˑ˒˖˗ 360 100 10000 7000 ERZE05A241 E241 ˓ˑ˖ 240 (216 to 264) 150 200 395 10 1200 600 AC 100 V to 120 V, Line–Line ˓ˑ˖ 395 25 2500 1250 ERZE08A241 E8241 ˓ˑ˖ 395 25 3500 2500 ERZE10A241 E10241 ˓ˑ˖ 395 50 4500 3000 ERZE11A241 E11241 ˓˕ˑ˒˖˗ 395 50 6000 5000 ERZE14A241 E14241 ˓˕ˑ˒˖˗ 395 100 10000 7000 ERZE05A271 E271 ˓ˑ˖ 270 (247 to 303) 175 225 455 10 1200 600 ERZE07A271 E7271 ˓ˑ˖ 455 25 2500 1250 ERZE08A271 E8271 ˓ˑ˖ 455 25 3500 2500 ERZE10A271 E10271 ˓ˑ˖ 455 50 4500 3000 ERZE11A271 E11271 ˓˕ˑ˒˖˗ 455 50 6000 5000 ERZE14A271 E14271 ˓˕ˑ˒˖˗ 455 100 10000 7000 ERZE05A331 E331 ˓ˑ˖ 330 (297 to 363) 210 270 545 10 1200 600 AC 100 V to 120 V, Line–Line Telephone Line Applications, (For DC 250 V Insulation Resistance Test) ERZE07A331 E7331 ˓ˑ˖ 545 25 2500 1250 ERZE08A331 E8331 ˓ˑ˖ 545 25 3500 2500 ERZE10A331 E10331 ˓ˑ˖ 545 50 4500 3000 ERZE11A331 E11331 ˓˕ˑ˒˖˗ 545 50 6000 4500 ERZE14A331 E14331 ˓˕ˑ˒˖˗ 545 100 10000 6500 ERZE05A361 E361 ˓ˑ˖ 360 (324 to 396) 230 300 595 10 1200 600 ERZE07A361 E7361 ˓ˑ˖ 595 25 2500 1250 ERZE08A361 E8361 ˓ˑ˖ 595 25 3500 2500 ERZE10A361 E10361 ˓ˑ˖ 595 50 4500 3000 ERZE11A361 E11361 ˓˕ˑ˒˖˗ 595 50 6000 4500 ERZE14A361 E14361 ˓˕ˑ˒˖˗ 595 100 10000 6500 ERZE05A391 E391 ˓ˑ˖ 390 (351 to 429) 250 320 650 10 1200 600 ERZE07A391 E7391 ˓ˑ˖ 650 25 2500 1250 ERZE08A391 E8391 ˓ˑ˖ 650 25 3500 2500 ERZE10A391 E10391 ˓ˑ˖ 650 50 4500 3000 ERZE11A391 E11391 ˓˕ˑ˒˖˗ 650 50 6000 4500 ERZE14A391 E14391 ˓˕ˑ˒˖˗ 650 100 10000 6500 ERZE05A431 E431 ˓ˑ˖ 430 (387 to 473) 275 350 710 10 1200 600 AC 100 V to 220 V, Line–Line and Line–Ground Applications ERZE07A431 E7431 ˓ˑ˖ 710 25 2500 1250 ERZE08A431 E8431 ˓ˑ˖ 710 25 3500 2500 ERZE10A431 E10431 ˓ˑ˖ 710 50 4500 3000 ERZE11A431 E11431 ˓˕ˑ˒˖˗ 710 50 6000 4500 ERZE14A431 E14431 ˓˕ˑ˒˖˗ 710 100 10000 6500 ˓ : UL1449 (VZCA2/UL, VZCA8/C-UL), ˔ : UL1449 Type3 (or Code-Connected and Direct plug-in), ˕ : UL1449 Type2 (or Permanently Connected), ˑ : VDE (IEC61051-1, -2, -2-2), ˒ : VDE (IEC60950-1 Annex.Q) ˖ : CQC (GB/T10193, GB/T10194), ˗ : CQC (GB4943.1, GB8898) ˞Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest f ile No. Dec. 201307

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) ■ Reference Guide to Standard Products Part No. Applicable Standards Varistor Voltage at 1 mA Maximum Allowable Voltage Clamping Voltage at 8/20μs Maximum Peak Current at 8/20μs(A) Recommended Applications Type Name Approvals (V) ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times ERZE05A471 E471 ˓ˑ˖ 470 (423 to 517) 300 385 775 10 1200 600 AC 100 V to 220 V, Line–Line and Line–Ground Applications ERZE07A471 E7471 ˓ˑ˖ 775 25 2500 1250 ERZE08A471 E8471 ˓˔ˑ˒˖˗ 775 25 3500 2500 ERZE10A471 E10471 ˓˔ˑ˒˖˗ 775 50 4500 3000 ERZE11A471 E11471 ˓˕ˑ˒˖˗ 775 50 6000 4500 ERZE14A471 E14471 ˓˕ˑ˒˖˗ 775 100 10000 6500 ERZE07A511 E7511 ˓ˑ˖ 510 (459 to 561) 320 410 845 25 2500 1250 AC 100 V to 240 V, Line–Line and Line–Ground Applications ERZE08A511 E8511 ERZE10A511 E10511 ˓˔ˑ˒˖˗ 845 50 4500 3000 ERZE11A511 E11511 ˓˕ˑ˒˖˗ 845 50 6000 4500 ERZE14A511 E14511 ˓˕ˑ˒˖˗ 845 100 10000 6500 ERZE07A561 E7561 ˓ˑ˖ 560 (504 to 616) 350 450 930 25 2500 1250 ERZE08A561 E8561 ˓˔ˑ˒˖˗ 930 25 3500 2500 ERZE10A561 E10561 ˓˔ˑ˒˖˗ 930 50 4500 3000 ERZE11A561 E11561 ˓˕ˑ˒˖˗ 930 50 6000 4500 ERZE14A561 E14561 ˓˕ˑ˒˖˗ 930 100 10000 6500 ERZE07A621 E7621 ˓ˑ˖ 620 (558 to 682) 385 505 1025 25 2500 1250 ERZE08A621 E8621 ˓˔ˑ˒˖˗ 1025 25 3500 2500 ERZE10A621 E10621 ˓˔ˑ˒˖˗ 1025 50 4500 3000 ERZE11A621 E11621 ˓˕ˑ˒˖˗ 1025 50 5000 4500 ERZE14A621 E14621 ˓˕ˑ˒˖˗ 1025 100 7500 6500 680 (612 to 748) 420 560 1120 25 3500 2500 ERZE10A681 E10681 ˓˔ˑ˒˖˗ 1120 50 4500 3000 ERZE11A681 E11681 ˓˕ˑ˒˖˗ 1120 50 5000 4500 ERZE14A681 E14681 ˓˕ˑ˒˖˗ 1120 100 7500 6500 750 (675 to 825) 460 615 1240 25 3500 2500 AC 380 V, Line–Line and Line–Ground Applications (For DC 500 V Insulating Test) ERZE10A751 E10751 ERZE11A751 E11751 ˓˕ˑ˒˖˗ 1240 50 5000 4500 ERZE14A751 E14751 ˓˕ˑ˒˖˗ 1240 100 7500 6500 820 (738 to 902) 510 670 1355 50 4500 3000 ERZE11A821 E11821 ˓˕ˑ˒˖˗ 1355 50 5000 4500 ERZE14A821 E14821 ˓˕ˑ˒˖˗ 1355 100 7500 6500 910 (819 to 1001) 550 745 1500 50 4500 3000 AC 415 V, Line–Line and Line–Ground Applications (For DC 500 V Insulating Test) ERZE11A911 E11911 ERZE14A911 E14911 ˓˕ˑ˒˖˗ 1500 100 7500 6500 1000 (900 to 1100) 625 825 1650 50 4500 3000 AC 480 V, Line–Line and Line–Ground Applications (For DC 500 V Insulating Test) ERZE11A102 E11102 ERZE14A102 E14102 ˓˕ˑ˒˖˗ 1650 100 7500 6500 1100 (990 to 1210) 680 895 1815 50 4500 3000 ERZE11A112 E11112 ˓˕ˑ˒˖˗ 1815 50 5000 4500 ERZE14A112 E14112 ˓˕ˑ˒˖˗ 1815 100 7500 6500 ˓ : UL1449 (VZCA2/UL, VZCA8/C-UL), ˔ : UL1449 Type3 (or Code-Connected and Direct plug-in), ˕ : UL1449 Type2 (or Permanently Connected), ˑ : VDE (IEC61051-1, -2, -2-2), ˒ : VDE (IEC60950-1 Annex.Q) ˖ : CQC (GB/T10193, GB/T10194), ˗ : CQC (GB4943.1, GB8898) ˞Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest f ile No. Dec. 201307

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) D T F F A20.0 min. f 0.6 L L Series E5 ■ Ratings and Characteristics

  • Operating Temperature Range : –40 to 85 °C ● Storage Temperature Range : –40 to 125 °C ✽Ip Measuring current of clamping voltage : 10 A ■ Dimensions in mm (not to scale) Part No. Varistor Voltage Maximum Allowable Voltage Clamping Voltage (max.) ✽Ip Rated Power Maximum Energy Maximum Peak Current (8/20 μs) Capacitance (max.) (10/1000 μs) (2 ms) 1 time 2 times V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE05A201 200(185 to 225) 130 170 340 0.25 13 9.5 1200 600 200 ERZE05A221 220(198 to 242) 140 180 360 0.25 14 10 1200 600 190 ERZE05A241 240(216 to 264) 150 200 395 0.25 15 11 1200 600 170 ERZE05A271 270(247 to 303) 175 225 455 0.25 18 13 1200 600 150 ERZE05A331 330(297 to 363) 210 270 545 0.25 21 15 1200 600 130 ERZE05A361 360(324 to 396) 230 300 595 0.25 23 17 1200 600 130 ERZE05A391 390(351 to 429) 250 320 650 0.25 26 19 1200 600 130 ERZE05A431 430(387 to 473) 275 350 710 0.25 29 21 1200 600 120 ERZE05A471 470(423 to 517) 300 385 775 0.25 32 23 1200 600 100 Jun. 201300

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) 100 200 300 400 500 600 700 800 900 1000 2000 -6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 Voltage (V) Current (A) 241 471 431 391 361 221 201 271 331 471 431 391 361 331 271 241 221 201 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs .BY$MBNQJOH7PMUBHF.BY -FBLBHF$VSSFOU Impulse Width (μs) Impulse Current (A) 10000 1000 100 0.1 20 100 1000 10000

1 Time

2 Times

10 Times

102 Times

103 Times104 Times

105 Times

106 Times

5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times : ■ Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE05A201 to ERZE05A471ERZE05A201 to ERZE05A471 Jun. 201300

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) D T F F A20.0 min. f 0.8 L L Series E7 ■ Ratings and Characteristics

  • Operating Temperature Range : –40 to 85 °C ● Storage Temperature Range : –40 to 125 °C ✽Ip Measuring current of clamping voltage : 25 A ■ Dimensions in mm (not to scale) Part No. Varistor Voltage Maximum Allowable Voltage Clamping Voltage (max.) ✽Ip Rated Power Maximum Energy Maximum Peak Current (8/20 μs) Capacitance (max.) (10/1000 μs) (2 ms) 1 time 2 times V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE07A201 200(185 to 225) 130 170 340 0.3 26 19 2500 1250 360 ERZE07A221 220(198 to 242) 140 180 360 0.3 30 22 2500 1250 350 ERZE07A241 240(216 to 264) 150 200 395 0.3 33 24 2500 1250 340 ERZE07A271 270(247 to 303) 175 225 455 0.3 39 28 2500 1250 310 ERZE07A331 330(297 to 363) 210 270 545 0.3 44 32 2500 1250 280 ERZE07A361 360(324 to 396) 230 300 595 0.3 50 36 2500 1250 260 ERZE07A391 390(351 to 429) 250 320 650 0.3 53 38 2500 1250 240 ERZE07A431 430(387 to 473) 275 350 710 0.3 60 43 2500 1250 210 ERZE07A471 470(423 to 517) 300 385 775 0.3 65 47 2500 1250 170 ERZE07A511 510(459 to 561) 320 410 845 0.3 70 50 2500 1250 140 ERZE07A561 560(504 to 616) 350 450 930 0.3 75 55 2500 1250 140 ERZE07A621 620(558 to 682) 385 505 1025 0.3 80 60 2500 1250 135 Sep. 201301

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) 100 200 300 400 500 600 700 800 900 1000 2000 471 511 561 431 391 361 621 561 511 471 431 391 361 331 271 241 221 201 621 271 201 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 241 221 331 Voltage (V) Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs Current (A) .BY$MBNQJOH7PMUBHF.BY -FBLBHF$VSSFOU 10000 1000 100 20 100 1000 10000 Impulse Width (μs) Surge Current (A)

2 Times10

3 Times

104 Times105 Times

5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times : ■ Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE07A201 to ERZE07A621ERZE07A201 to ERZE07A621 Sep. 201301

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) D T F F A20.0 min. f 0.8 L L Series E8 ■ Ratings and Characteristics

  • Operating Temperature Range : –40 to 85 °C ● Storage Temperature Range : –40 to 125 °C ✽Ip Measuring current of clamping voltage : 25 A ■ Dimensions in mm (not to scale) Part No. Varistor Voltage Maximum Allowable Voltage Clamping Voltage (max.) ✽Ip Rated Power Maximum Energy Maximum Peak Current (8/20 μs) Capacitance (max.) (10/1000 μs) (2 ms) 1 time 2 times V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE08A201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 390 ERZE08A221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 380 ERZE08A241 240(216 to 264) 150 200 395 0.4 42 30 3500 2500 360 ERZE08A271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 330 ERZE08A331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300 ERZE08A361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 280 ERZE08A391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 260 ERZE08A431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 230 ERZE08A471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 180 ERZE08A511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 150 ERZE08A561 560(504 to 616) 350 450 930 0.4 92 67 3500 2500 150 ERZE08A621 620(558 to 682) 385 505 1025 0.4 92 67 3500 2500 140 ERZE08A681 680(612 to 748) 420 560 1120 0.4 92 67 3500 2500 130 ERZE08A751 750(675 to 825) 460 615 1240 0.4 100 70 3500 2500 130 Aug. 201200

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) 10000 1000 100 20 100 1000 Impulse Width (μs) Surge Current (A) 10000

3 Tim

106 Tim

5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times : 100 200 300 400 500 600 700 800 900 1000 2000 471 431 391 361 511 471 431 391 361 331 271 241 221 201 511 271 201 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 241 221 331 221 331 Voltage (V) Current (A) .BY -FBLBHF$VSSFOU .BY$MBNQJOH7PMUBHF 105 Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 Voltage (V) 751 681 621 561 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 Current (A) 751 681 621 561 .BY$MBNQJOH7PMUBHF.BY -FBLBHF$VSSFOU Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs 10000 1000 100 20 100 1000 10000 Impulse Width (μs) Surge Current (A)

1 Time2 Times

104 Times

5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times : ERZE08A561 to ERZE08A751 ERZE08A201 to ERZE08A511 ERZE08A561 to ERZE08A751 ERZE08A201 to ERZE08A511 ■ Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) Aug. 201200

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) D T F F A20.0 min. f 0.8 L L Series E10 ■ Ratings and Characteristics

  • Operating Temperature Range : –40 to 85 °C ● Storage Temperature Range : –40 to 125 °C ✽Ip Measuring current of clamping voltage : 50 A ■ Dimensions in mm (not to scale) Part No. Varistor Voltage Maximum Allowable Voltage Clamping Voltage (max.) ✽Ip Rated Power Maximum Energy Maximum Peak Current (8/20 μs) Capacitance (max.) (10/1000 μs) (2 ms) 1 time 2 times V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE10A201 200(185 to 225) 130 170 340 0.5 47 34 4500 3000 630 ERZE10A221 220(198 to 242) 140 180 360 0.5 50 36 4500 3000 600 ERZE10A241 240(216 to 264) 150 200 395 0.5 56 40 4500 3000 570 ERZE10A271 270(247 to 303) 175 225 455 0.5 64 46 4500 3000 530 ERZE10A331 330(297 to 363) 210 270 545 0.5 72 52 4500 3000 470 ERZE10A361 360(324 to 396) 230 300 595 0.5 84 60 4500 3000 430 ERZE10A391 390(351 to 429) 250 320 650 0.5 91 65 4500 3000 400 ERZE10A431 430(387 to 473) 275 350 710 0.5 99 71 4500 3000 350 ERZE10A471 470(423 to 517) 300 385 775 0.5 106 76 4500 3000 320 ERZE10A511 510(459 to 561) 320 410 845 0.5 117 84 4500 3000 300 ERZE10A561 560(504 to 616) 350 450 930 0.5 120 86 4500 3000 290 ERZE10A621 620(558 to 682) 385 505 1025 0.5 126 88 4500 3000 280 ERZE10A681 680(612 to 748) 420 560 1120 0.5 133 95 4500 3000 260 ERZE10A751 750(675 to 825) 460 615 1240 0.5 140 100 4500 3000 250 ERZE10A821 820(738 to 902) 510 670 1355 0.5 154 110 4500 3000 230 ERZE10A911 910(819 to 1001) 550 745 1500 0.5 168 112 4500 3000 220 ERZE10A102 1000(900 to 1100) 625 825 1650 0.5 182 130 4500 3000 200 ERZE10A112 1100(990 to 1210) 680 895 1815 0.5 196 140 4500 3000 180 Jul. 201301

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) 10000 1000 100 20 100 1000 Impulse Width (μs) Surge Current (A) 10000 5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times : 100 200 300 400 500 600 700 800 900 1000 2000 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 561 511 471 431 391 361 331 221 271 241 201 561 511 471 431 391 361 331 271 241 221 201 Voltage (V) Current (A) Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs .BY$MBNQJOH7PMUBHF.BY -FBLBHF$VSSFOU 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 112 102 911 821 -6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 112 102 911 821 751 681 621 Voltage (V) Current (A) Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs .BY$MBNQJOH7PMUBHF.BY -FBLBHF$VSSFOU 751 681 621 10000 1000 100 20 100 1000 Impulse Width (μs) Surge Current (A) 10000 5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times : ERZE10A621 to ERZE10A112 ERZE10A201 to ERZE10A561 ERZE10A621 to ERZE10A112 ERZE10A201 to ERZE10A561 ■ Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) Jul. 201301

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) D T F F A20.0 min. f 0.8 L L Series E11 ■ Ratings and Characteristics

  • Operating Temperature Range : –40 to 85 °C ● Storage Temperature Range : –40 to 125 °C ✽Ip Measuring current of clamping voltage : 50 A ■ Dimensions in mm (not to scale) Part No. Varistor Voltage Maximum Allowable Voltage Clamping Voltage (max.) ✽Ip Rated Power Maximum Energy Maximum Peak Current (8/20 μs) Capacitance (max.) (10/1000 μs) (2 ms) 1 time 2 times V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE11A201 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 690 ERZE11A221 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 660 ERZE11A241 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 620 ERZE11A271 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 580 ERZE11A331 330(297 to 363) 210 270 545 0.6 115 80 6000 4500 520 ERZE11A361 360(324 to 396) 230 300 595 0.6 130 90 6000 4500 480 ERZE11A391 390(351 to 429) 250 320 650 0.6 140 100 6000 4500 450 ERZE11A431 430(387 to 473) 275 350 710 0.6 155 110 6000 4500 400 ERZE11A471 470(423 to 517) 300 385 775 0.6 175 125 6000 4500 360 ERZE11A511 510(459 to 561) 320 410 845 0.6 190 136 6000 4500 310 ERZE11A561 560(504 to 616) 350 450 930 0.6 190 136 6000 4500 310 ERZE11A621 620(558 to 682) 385 505 1025 0.6 190 136 5000 4500 300 ERZE11A681 680(612 to 748) 420 560 1120 0.6 190 136 5000 4500 290 ERZE11A751 750(675 to 825) 460 615 1240 0.6 210 150 5000 4500 280 ERZE11A821 820(738 to 902) 510 670 1355 0.6 235 165 5000 4500 260 ERZE11A911 910(819 to 1001) 550 745 1500 0.6 255 180 5000 4500 240 ERZE11A102 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 4500 220 ERZE11A112 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 4500 200 Aug. 201200

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) 10000 1000 100 20 100 1000 Impulse Width (μs) 10000 Surge Current (A) 5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times :

1 Tim

e

2 Tim

2000Voltage (V) 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 Current (A) 511 471 431 391 361 331 221 271 241 201 511 471 431 391 361 331 271 241 221 201 .BY -FBLBHF$VSSFOU .BY$MBNQJOH7PMUBHF Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 Voltage (V) 112 112 102 911 821 561 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 Current (A) 751 681 621 621 561 102 911 821 751 681 .BY -FBLBHF$VSSFOU .BY$MBNQJOH7PMUBHF Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs 10000 1000 100 20 100 1000 10000 5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times : Surge Current (A) Impulse Width (μs) ■ Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) Aug. 201200

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) F L D T F A20.0 min. f 1.0 L Series E14 ■ Ratings and Characteristics

  • Operating Temperature Range : –40 to 85 °C ● Storage Temperature Range : –40 to 125 °C ✽Ip Measuring current of clamping voltage : 100 A ■ Dimensions in mm (not to scale) Part No. Varistor Voltage Maximum Allowable Voltage Clamping Voltage (max.) ✽Ip Rated Power Maximum Energy Maximum Peak Current (8/20 μs) Capacitance (max.) (10/1000 μs) (2 ms) 1 time 2 times V1 mA (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) at 1 kHz (pF) ERZE14A201 200(185 to 225) 130 170 340 1.0 140 100 10000 7000 1300 ERZE14A221 220(198 to 242) 140 180 360 1.0 155 110 10000 7000 1200 ERZE14A241 240(216 to 264) 150 200 395 1.0 168 120 10000 7000 1100 ERZE14A271 270(247 to 303) 175 225 455 1.0 190 135 10000 7000 1000 ERZE14A331 330(297 to 363) 210 270 545 1.0 228 160 10000 6500 900 ERZE14A361 360(324 to 396) 230 300 595 1.0 255 180 10000 6500 900 ERZE14A391 390(351 to 429) 250 320 650 1.0 275 195 10000 6500 800 ERZE14A431 430(387 to 473) 275 350 710 1.0 303 215 10000 6500 800 ERZE14A471 470(423 to 517) 300 385 775 1.0 350 250 10000 6500 750 ERZE14A511 510(459 to 561) 320 410 845 1.0 382 273 10000 6500 700 ERZE14A561 560(504 to 616) 350 450 930 1.0 382 273 10000 6500 700 ERZE14A621 620(558 to 682) 385 505 1025 1.0 382 273 7500 6500 650 ERZE14A681 680(612 to 748) 420 560 1120 1.0 382 273 7500 6500 600 ERZE14A751 750(675 to 825) 460 615 1240 1.0 420 300 7500 6500 530 ERZE14A821 820(738 to 902) 510 670 1355 1.0 460 325 7500 6500 500 ERZE14A911 910(819 to 1001) 550 745 1500 1.0 510 360 7500 6500 400 ERZE14A102 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 6500 400 ERZE14A112 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 6500 350 Feb. 201301

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) 10000 1000 100Surge Current (A) 20 100 1000 Impulse Width (μs) 10000 5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times :

2 Time

10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 Current (A) 511 471 431 391 361 331 271 241 221 201 .BY -FBLBHF$VSSFOU .BY$MBNQJOH7PMUBHF Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs Voltage (V) 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 112 102 911 821 751 681 621 561 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 Current (A) 112 102 911 751 681 621 561 821 Voltage (V) Test Current Waveform 10-6 to 10-3 A: Direct Current 10-1 to 104 A: 8/20 μs .BY -FBLBHF$VSSFOU .BY$MBNQJOH7PMUBHF 10000 1000 100 20 100 1000 10000 Surge Current (A) Impulse Width (μs) 5 min. interval 2 min. interval 10 sec. interval 2 times : up to 10 times : up to 106 times :

3 Times10

4 Times

105 Times106 Times

■ Typical Characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) Feb. 201301

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) D T== L=F fd AB DT == L=F fd C A B === C Straight Leads Cut Type (Bulk Type) ■ Ratings and Characteristics ✽ Refer to bulk standard type part no. (P4 to P13). ■ Dimensions in mm (not to scale) notes ✽ Dimension “L ” : Con f orms t o ea ch ind ivi dual spec ifi ca tion . ✽✽ Dimension “T”: Conforms to each individual specifi cation. Crimped Leads Cut Type (Bulk Type) ■ Ratings and Characteristics ✽ Refer to bulk standard type part no. (P4 to P13). ■ Dimensions in mm (not to scale) notes ✽ Dimension “L ”: Conforms to each individual specifi cation. ✽✽ Dimension “T”: Conforms to each individual specifi cation. ✽✽✽ Resin extenyions : No resin below the center of the hook. Unit (mm) Series E5 E7 E8 E10 E11 Varistor VoltageSymbol 201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 112 201 to 561 621 to 112 Standard Products Part No. Unit (mm) Series E5 E7 E8 E10 E11 Varistor VoltageSymbol 201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 561 621 to 112 Standard Products Part No. –0.05–0.05 –0.05–0.05 –0.05 May. 201403

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) P2 P f D0 f D f d F L A W t W0 W2 H Position of H0 dimension Position of F1 dimension ✽ Dimension “T”: Conforms to each individual specifi cation. Taping Specifi cations for Automated Assembly (Straight Leads and Taping) ■ Ratings and Characteristics ✽ Refer to bulk standard type part no. (P4 to P13). ■ Taping Dimensions in mm (not to scale) Unit (mm) Series E5 E7 E8 E10 E11 Varistor Voltage 201 to 471 201 to 271 331 to 551 561 621 201 to 221 241 to 561 621 to 751 201 to 221 241 to 561 621 to 112 201 to 221 241 to 561 621 to 112 Standard Products Part No. –0.05 –0.05 –0.05 –0.5 –0.5 –0.5 –0.5 Symbol –0.05 –0.05 –0.5–0.5–0.5 –0.5–0.5–0.5 –0.5 –0.5 May. 201403

Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. “ZNR” Transient/Surge Absorbers (Type D) P2 P f D0 f D f d F L A W t W0 W2 H Taping Specifi cations for Automated Assembly (Crimped Leads and Taping) ■ Ratings and Characteristics ✽ Refer to bulk standard type part no. (P4 to P13). ■ Taping Dimensions in mm (not to scale) ✽ Dimension “T”: Conforms to each individual specifi cation. Unit (mm) Series E5 E7 E8 E10 E11 Varistor Voltage 201 to 471 201 to 511 561 621 201 to 221 241 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 221 241 to 561 621 to 112 Standard Products Part No. Symbol –0.05–0.05–0.05 –0.05 –0.05 –0.5 –0.05 –0.5 –0.05 –0.5 May. 201403