ERS-00A ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Features
Dimension: 74Wx68Lx27H [mm] 1.Open Frame 2. Input: 100/200Vac 3. High Efficiency 4. Cost effective 5. Output Voltage adjustable 6. Over Voltage Protection 7. EMI: complies to FCC/B 8. Safety: UL 1950, CSA 950(C-UL) approved Output Characteristics Unit ERS01A ERS03A ERS04A Output Voltage Vdc +5 +12 -12 +5 +12 -5 +5 +15 -15 Voltage Tolerance V V1:+3%/-0% of Rated Output Voltage(at no load within the input range) V2:fixed with tolerance of +/-3.5%(at no load within the input range) Ripple and Noise(max.) *3 mV 100 170 170 100 170 100 100 200 200 Regulation a. Static Line Regulation max. mV 25 60 60 25 60 25 25 75 75 b. Static Load Regulation max. mV 50 120 120 50 120 50 50 150 150 c. Temperature Coefficient *4 %/°C 0.03%/ºC d.Drift max. *5 mV 40 75 75 40 75 40 40 90 90 e. Dynamic Load Reg. typ.*6 mV Not Specified f. Recovery Time *6 mS Not Specified g. Rise Time mS 200mS(maximum) at rated input/output h. Hold Up Time mS 20mS(typical) at rated input/output Input Models Characteristics Unit ERS01A ERS03A ERS04A Input Voltage Vac AC 100 V[DC 130 V] Input Voltage Range Vdc AC85~132V [DC110-175V] Input Current A 0.25 Input Frequency Hz 50/60Hz Input Frequency Range Hz 47-440Hz Inrush Current *1 A 25A(maximum) at AC100V Phase Single Efficiency (typical) *2 % 67 67 70 AACC//DDCC SSWWIITTCCHHIINNGG PPOOWWEERR SSUUPPPPLLYY IINNPPUUTT:: 8855~~113322VVAACC TTRRIIPPLLEE OOUUTTPPUUTT
88 WWAATTTTSS
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com CCoonnddiittiioonnss:: *1 cold start *2 at DC130V input, rated output *3 measured by a bayonet probe at the output connector at a 0 to 100MHz bandwidth *4 at -5 to +50°C *5 only for 7hours from 1hour after switch-on at 25°C and rated input/output *6 when output current changed from 25% to 75% of rated output current rapidly at AC100V input *7 variable on input voltage and load conditions BBLLOOCCKK DDIIAAGGRRAAMM Environmental Specification Operating Temperature -5~+50°C Operating Humidity 85%RH(non-condensing) Storage Temperature -20 to +85°C Storage Humidity 85%RH(non-condensing) Withstanding Voltage Primary-Secondary AC1500V for 1minute Primary-Frame Ground AC1500V for 1minute Secondary-Frame Ground AC500V for 1minute Vibration 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) Shock 294m/s2 Cooling Convection Isolation Resistance Primary-Secondary-Frame Ground 50M Ω(minimum) by DC500V insulation tester Function/Protection V1:Current Limiting with automatic recovery V2,V3:by the regulator I.C 's characteristics Over current Protection ≥110% of Rated Output V1:Zenner diode clamping V2,V3:not available Over voltage Protection ≥115% of Rated Output Remote Sense not available Remote On/Off not available Other Specifications Leakage Current(typ.) 1mA(maximum) at 25ºC ,rated input/output and rated input frequency Line Conducted Noise Built to meet FCC Part15-B Class B MTBF [H] *9 1000000 Mechanical Specification Dimension [mm] 43Wx47.5Lx18.5H [mm] Weight (typical) open board type:27g[unit with chassis/cover:30g]
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com DDIIMMEENNSSIIOONN DDIIAAGGRRAAMM DERATING CURVE EFFICIENCY CURVE OCP CURVES