ERM-00A ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
- Open Frame 2. Cost Effective 3. High Efficiency 4. No derating without cover and horizontal mounting 5. Input 170-264Vac 6. EMI : complies with FCC/A, FCC/B for ERD & ERE 7. Over voltage protection Cover(add suffix “-P”) **”-P” model dimension is same as “without cover” model General Description “ER”-Series AC/DC Switching power supplies are open frame, low cost with high efficiency. 65 different models are available from low to medium power. A low power modules use a simple RCC circuit while high power supplies employ a forward converter.
15 WATT
Specifications<AC/DC> ERM**A 15WATTS/3OUTPUTS Input Voltage Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 Model ERM01A ERM03A 69 66 70 ERM04A 47-440Hz Single 25A(maximum)at AC100V AC100V(DC130V) AC85-132V(DC110-175V) 50/60Hz
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com OCP Curves
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com ERMA Specification Specifications<AC/DC> Model ERMA 15WATTS/3OUTPUTS Output Characteristic Output Voltage [V] 5 +12 -12 5 +12 -5 5 +15 -15 Voltage Adjust Range Ripple and Noise mVp-p *3 100 170 170 100 170 100 100 200 200 Regulation S t a t i s t i c L i n e R e g u l a t i o n [ m V ] ( m a x i m u m ) 2 56 06 02 56 02 52 57 57 5 Statistic Load Regulation mV 50 120 120 50 120 50 50 150 150 Temperature Coefficient *4 DriftmV *5 40 75 75 40 75 40 40 90 90 Dynamic Load Regulation mV *6 Recovery Time *6 Rise up time Hold up time Functions clamping V2,V3:not availabl e Remote Sense not available Remote On/Off not available Environmental Operating Temperature Operating Humidity Storage Temperature Storage Humidity Withstanding Voltage Isolation Resistance Vibration Shock Cooling ? Leakage Current 1mA(maximum) at 25℃,rated input/output and rated input frequency ? Line conducted noise et FCC Part15-B Class B ? Safety Weight (typical) enclosed type:280g ? MTBF [H] 820,000 ? Switching FrequencykHz *7 25 30 Conditions: *1 at cold start *2 at DC130V input and rated output *3 measured by a bayonet probe at output connector at 0 to 100MHz bandwidth *4 at -5 to +50℃ *5 for 7hour period after 1hour warm-up at 25℃ and rated input/output *6 when output current changed from 25% to 75% of rated output current rapidly at AC100V input *7 variable on input voltage and load conditions Primary-Secondary AC1,500V for 1minute Primary-Frame Ground AC1,500V for 1minute Secondary-Frame Ground AC500V for 1minute 98m/s Convection Overcurrent Protection ≧120% of Rated Output Current[A] V1:Current Limiting with automatic recovery V2,V3:by the regulator I.C's characteristics Overvoltage Protection ≧115% of Rated Output Voltage[V] -5 to +50℃ Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) ERM04A V1:+3%/-0% of Rated Output Voltage(at no load within the input range) V2:fixed with tolerance of +/-3.5%(at no load within the input range) ERM01A ERM03A 0.03%/℃ not specified not specified 200mS(maximum) at 25℃ and rated input/output 20mS(minimum) at 25℃ and rated input/output 85%RH(non-condensing) -20 to +85℃ 85%RH(non-condensing)
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Dimension (mm) Efficiency Curve Derating Curve