Features

  1. Cost effective 2. High efficiency 3. No derating without cover and horizontal mounting 4. Over voltage protection General Description ER-series is an open frame, low cost switcher with high efficiency. 65 different models are available from low to medium power. Low power modules use a simple RCC circuit while higher power supplies employ a forward converter. Options Case cover (add suffix “-P”) “-P” model dimension is same as “without cover” model

25 WATT

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Dimension (mm)

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com ERASA Specification Specifications<AC/DC> ERASA 25WATTS/SINGLE Output Voltage [V] 5 12 15 24 48 Voltage Adjust Range Ripple and Noise mVp-p *3 100 170 200 290 530 Regulation Statistic Line Regulation mV 25 60 75 120 240 Statistic Load Regulation mV 50 120 150 240 480 Temperature Coefficient *4 DriftmV *5 40 75 90 135 255 Dynamic Load Regulation mV *6 Recovery Time *6 Rise up time Hold up time Remote Sense Remote On/Off Operating Temperature Operating Humidity Storage Temperature Storage Humidity Vibration Shock Cooling ? Leakage Current ? Line Conducted Noise ? Safety Weight (typical) ? MTBF [H] ? Switching FrequencykHz *7 25 40 40 40 40 Convection not specified not specified 200mS(maximum) at 25℃ and rated input/output 20mS(minimum) at 25℃ and rated input/output Functions Overcurrent Protection≧105% of Rated Output Current[A] 294m/s Model ERA05SA ERA12SA ERA15SA ERA24SA ERA48SA Output Characteristic +/- 10% of Rated Output Voltage(at no load within the input range) 0.03%/℃ Current Limiting with automatic recovery Overvoltage Protection ≧112% of Rated Output Voltage[V] output shutdown(to reset,leave 30seconds after shut-off) not available not available Environmental -5 to +50℃[enclosed type:-5 to 50℃ at vertical mount/-5 to 45℃ at horizontal mount] 85%RH(non-condensing) -20 to +85℃ 85%RH(non-condensing) Withstanding Voltage Primary-Secondary AC1,500V for 1minute Primary-Frame Ground AC1,500V for 1minute Secondary-Frame Ground AC500V for 1minute Isolation Resistance Primary-Secondary-Frame Ground 50M Ω(minimum) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) 1mA(maximum) at 25℃,rated input/output and rated input frequency Built to meet FCC Part15-B Class B 280g/enclosed type:340g 610,000 Conditions: *1 at cold start *2 at DC130V input and rated output *7 variable on input voltage and load conditions *3 measured by a bayonet probe at output connector at 0 to 100MHz bandwidth *4 at -5 to +50℃ *5 for 7hour period after 1hour warm-up at 25℃ and rated input/output *6 when output current changed from 25% to 75% of rated output current rapidly at AC100V input

ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Block Diagram Derating Curve OCP Curve