EPXA4, revision A (see Figure 1) Devices. Figure 1. Identify Revision A Devices Contact Altera® for the latest information.

2 Altera Corporation

Excalibur EPXA4 Devices Errata Sheet EBI This section provides further information about errata in the EBI.

1.1 Locked 16-Beat Incrementing Bursts

A locked INCR16 transfer can cause the EBI to read from a peripheral twice. This can cause erroneous behavior if the peripheral contains read- sensitive registers. Work Around Do not use burst transactions to access read-sensitive peripherals connected to the EBI.

1.2 EBI Acknowledge Signal

The EBI acknowledge signal, EBI_ACK, functionality results in incorrect EBI asynchronous mode operation. Work Around Do not use the EBI_ACK signal when interfacing to external memory devices. Instead, use the programmable wait states, via the EBI_BLOCKn register, for the individual EBI blocks. Also ensure that the SA bit for each EBI block is cleared. This effectively puts the EBI in synchronous mode. EBI synchronous mode can be used to interface with synchronous or asynchronous memories provided that the appropriate number of wait states is implemented. DPRAM This section provides further information about errata in the DPRAM.

2.1 Port A Clocks Are Not Pre-Balanced

If the DPRAM is configured in either a deep (×8) or a wide (×32) mode, the dp0_2_portaclk and dp1_3_portaclk clock signals are not pre- balanced. The Quartus ® II fitter is unable to balance locally routed clocks and generates an error. Work Around Promote dp0_2_portaclk or the dp1_3_portaclk signal to a global signal and recompile the design.

Excalibur EPXA4 Devices Errata Sheet

2.2 Locking Mechanism is Non-Functional

Using the DPRAM locking mechanism for simultaneous accesses from the stripe and PLD results in incorrect memory accesses. Simultaneous accesses to different addresses are not affected. Work Around Do not use the DPRAM locking feature. Instead, use a handshake mechanism such as a semaphore to control PLD and stripe accesses to common DPRAM addresses. AHB Bridges This section provides further information about errata in the AHB bridges.

3.1 Back-to-back Transactions through the PLD-to-Stripe Bridge Can

If the non-sequential address phase of a new transaction occurs in the same clock cycle as the final data phase of the previous transaction, the slave interface of the PLD-to-stripe bridge issues erroneous wait states causing masters to the PLD-to-stripe bridge in the PLD to lock up. Incorrect transactions can occur on AHB2. Work Around Insert an IDLE address phase between all transactions.

3.2 Corrupted State of the Stripe-to-PLD Bridge after PLD

Reconfiguration under Processor Control If the MASTER_HCLK signal is active during PLD reconfiguration under processor control, the stripe-to-PLD bridge can become corrupted before the device enters user mode. The bridge cannot respond to AHB2 transactions, which causes the AHB2 bus to lock up. Gating the source of MASTER_HCLK with INIT_DONE does not prevent the potential lock up. Work Arounds To avoid corrupting the bridge during PLD reconfiguration, the clock driving MASTER_HCLK must be inactive before the PLD enters user mode. This can be achieved in either of the following ways: ■ Software work around—compile the design using Quartus ® II version 2.1 or higher. These versions of Quartus II route the stripe-to-PLD bridge signals specifically to avoid the bridge lock up. The routing

4 Altera Corporation

Excalibur EPXA4 Devices Errata Sheet utilizes three extra logic elements in the device and adds minimal corresponding delay to the bridge timing. If logic element usage or bridge timing is critical to your design, you can disable the automatic Quartus II routing option by adding the following parameter to the defparam section of the stripe instantiation file generated by the MegaWizard lpm_instance.xa_configuration_fix = “FALSE“ If this routing option is disabled, you must use the hardware work around described below to ensure correct functionality.

1 If you use this recommended software workaround, ensure

that the Remove Redundant Logic Cells option is not selected for your project.

1 If the Perform WYSIWYG Primitive Resynthesis option is

selected for your project, you may receive warnings that the stripe signals were not routed correctly. To eliminate the warnings, re-run the MegaWizard in Quartus II version 2.2. This creates an additional settings file (alt_exc_stripe.esf) to ensure that the required logic elements are implemented. ■ Hardware work around—ensure that the external clock that drives MASTER_HCLK is inactive before the PLD is put into reconfiguration mode, and is enabled again only after the PLD enters user mode. INIT_DONE can be used only to activate the external clock. It should not be used to disable the clock, for the following reason: when reconfiguration begins, INIT_DONE does not drop to low in time to prevent the error. You must use another method to disable the external clock, such as using an external device to control the clock input. If a PLL in the PLD portion of the device is used to drive MASTER_HCLK, you must drive the PLL CLKLK_ENA signal with INIT_DONE so that the PLL output does not drive MASTER_HCLK before the device is in user mode. See AN 115: Using the ClockLock & ClockBoost PLL Features in APEX Devices for information on enabling the PLD PLLs with INIT_DONE.

Excalibur EPXA4 Devices Errata Sheet UART This section provides further information about errata in the UART.

4.1 UART State Undefined Following Reset

When the device comes out of reset, the UART may sometimes generate a modem interrupt and behave as though a character has been received. Work Around To avoid generating a modem interrupt, clear all interrupts and flush the receive and transmit FIFO buffers before interrupts from the UART are enabled. SDRAM This section provides further information about errata in the SDRAM. 5.1 32-bit DDR SDRAM Memories are Not Supported The SDRAM controller in the ARM-based family (including the EPXA4) does not support interfacing with 32-bit DDR SDRAM devices that use the A8 address line for the command sequence. Also 32-bit DDR memories have one DQS pin; ARM-based devices require four (one per byte). Memories that use the A10 address line for the command sequence and have one DQS pin per byte are supported.

5.2 Improper DDR SDRAM Data Accesses for Certain Clock Ratios

Incorrect data may result from DDR SDRAM accesses if the AHB1 or AHB2 master clock is greater than 4 times faster than the SDRAM clock, SD_CLK. Work Around Ensure that the AHB1/2 clock frequency is less than or equal to 4 times the SDRAM clock frequency. Embedded Trace Module Version 2a EPXA4 devices include the ARM ETM9 version 2a. Please see the ETM9_Rev_2a_Errata.doc for errata on this version of the ETM9. This document is available on the ARM Limited website. Version 2a has a different configuration code register value compared to version 1, which is used in the EPXA10 devices. The ARM Trace Tools version 1.1 does not support ETM9 version 2a. Support will be included in a new version of the trace tools planned for Q2 2002.

6 Altera Corporation

Excalibur EPXA4 Devices Errata Sheet Configuration This section provides further information about errata in configuration.

7.1 JTAG Configuration Error

JTAG configuration of the EPXA4 does not complete successfully if there are programmed EPC configuration devices in the JTAG chain and the EPXA4 is in boot-from-serial mode. The Quartus II Programmer reports an error stating that the CONF_DONE signal did not go high. Work Around Erase the EPC devices that are in the chain. This allows successful configuration in boot-from-serial-mode. Or assert the Boot_Flash pin, which sets the configuration mode to boot-from-flash. In this mode, you can successfully configure the device via JTAG. Debug Module This section provides further information about errata in the debug module.

8.1 DEBUG_IE_BRKPT and DEBUG_DE_WATCHPT Cause Incorrect

The DEBUG_IE_BRKPT and DEBUG_DE_WATCHPT lines do not function. If asserted, they cause breakpoints or watchpoints to trigger on the wrong instruction. Work Around Do not connect the DEBUG_IE_BRKPT and DEBUG_DE_WATCHPT lines in your design. The Quartus II software ties them low as appropriate.

specification and so are included for completeness. and use extend to all media in which this information may be embodied. definition of category 1 defined by ARM Ltd. Table 1. Errata Categories majority of applications rendering the device unusable.

2 Features which contravene the specified behaviour and may limit or severely impair the intended use

of specified features but does not render the device unusable in all or the majority of applications.

3 Features that were not the originally intended behaviour but should not cause any problems in

8 Altera Corporation

A.1 Errata for the ARM920T AHB Wrapper Module This section documents errata in the ARM920T AHB wrapper module, which is used in the Excalibur device. A.1.1 Linefill Counter—Category 2 The burst counter for a cache linefill is incorrectly pre-loaded if the linefill follows a waited access. This results in 9 reads being performed on the AHB bus rather than the required 8. The ARM920T receives the correct data: the only effects of the extra read are that an extra cycle is taken up on the bus, and any side-effects are due to the addressed area being read- sensitive (e.g. a FIFO). Work Around The software workaround is to ensure that only address areas which are not read-sensitive are cached. A.1.2 Error Response—Category 2 There is a bug in the ERROR response functionality in the wrapper. An ERROR response should only be accepted by the ARM920T if it is in response to a non-cacheable or non-bufferable access. The AHB wrapper only adds wait states to non-bufferable writes when ERROR support is added, since buffered writes do not need to be held up in order to propagate the respons. However, the ERROR response from the AHB is still propagated to the ASB in all cases. Thus a C/B access to the AHB which results in an ERROR response, followed by a NC/NB* access, means that the ERROR response appears on the ARM920T ASB interface as the response to the NC/NB access and so is accepted. Work Around The software workaround is to never access address regions which are capable of generating error responses with C/B accesses. *NC Non-cacheable NB Non-bufferable

A.2 Errata for the ETM9 Trace Module See Table 1 on page 7 and associated text for an explanation of categorisation. A.2.1 Invalid data trace following FIFO overflow—Category 1 Note: ARM has updated the errata classifications. This is a category 1 erratum under the previous definition, which was: ‘Features which it is impossible, or very hard, to work around and are likely to affect use of this device.’

Description

The Embedded Trace Macrocell (ETM) contains a small FIFO which under some circumstances can overflow, leading to the loss of trace. This is normal behavior. However, if the FIFO overflows during an extended wait-state period while attempting to capture data trace from a block data transfer instruction, then the data trace can become invalid. When trace is resumed: ■ Data values traced may be invalid until the next indirect branch. ■ Data addresses traced may be invalid until the next trace gap, or the next periodic synchronization point. ■ Instruction trace is unaffected. An example of how exactly the data trace becomes invalid is shown in Table 2 on page 10. Note that, for simplicity, data address tracing is ignored.

10 Altera Corporation

Table 2. Example of invalid data trace following overflow during wait-state period

1004 LDMIA r6, {r0 – r4} [r6]

1008 LDR r7, [r8] [r8] 1008 with data r7 <= invalid data

Extended wait-state periods can be caused by cache misses in cached systems, or the use of a slow memory system. Consequently, the problem is unlikely to occur in uncached systems or in systems where the speed of the memory is close to that of the processor. Since the clock speed on the ARM920T and ARM922T processors is slowed to that of the memory when a cache miss occurs, memory speed is not an issue on these processors, and consequently this erratum is less likely to occur on systems with these devices. The block data transfer instruction must be executing when the overflow occurs. The instructions which fall into this category are as follows: ■ ARM instructions: LDM, STM, SWP, SWPB, LDC, STC, LDRD, STRD, MCRR, MRRC. ■ Thumb instructions: POP, PUSH, LDMIA, STMIA. The wait-state period must begin before the overflow occurs. It is possible for an overflow to occur after the wait-state has begun due to trace continuing to enter the FIFO from the ETM pipeline. The wait-state period must continue until after the ETM has recovered from the overflow, having drained its FIFO of all pending trace. The problem is more likely to occur with a small FIFO than a large FIFO for two reasons: ■ A smaller FIFO is more likely to overflow. ■ Once an overflow has occurred, a smaller FIFO takes less time to drain. Consequently, the length of the extended wait-state period required for the problem to occur is reduced. As a result, the problem is most likely to occur with the small ETM configuration, and least likely with the large ETM configuration. The minimum number of cycles required to drain the FIFO, and therefore the theoretical minimum length of the wait-state period, is shown in Table 3 on page 12.

12 Altera Corporation

Table 3. Minimum length of the wait-state period for the problem to occur

While instruction trace remains unaffected, the user is unable to ascertain whether the data trace is correct. The erratum must be considered when the following occur together: ■ An overflow is reported. ■ The first instruction traced following the overflow is a block data transfer instruction. ■ The first instruction traced following the overflow includes data trace. ■ Either: – The address of the instruction traced both before and after overflow is the same – The address of the instruction traced after overflow is the next instruction address that would have been expected had the overflow not occurred. Examples of this case are: – The instructions before and after overflow are both LDMIA instructions at address 1000. – The instruction before overflow is a branch at address 1010 that failed its condition codes, and the instruction after overflow is an STMDB at address 1014. – The instruction before overflow is an LDR to the pc at address 1020 which caused a branch to address 1040, and the instruction after overflow is an LDCL at address 1040. This case may be difficult to detect by the user, although it is possible for tools to be able to detect this because the target address of a branch is always traced, even if the next instruction is not. ■ The amount of data trace lost depends on the position of the next indirect branch, and the data tracing mode selected. An indirect branch is any branch which is not a B, BL or BLX instruction, such as an LDR to the program counter.

14 Altera Corporation

One of the following apply: The first instruction traced following the overflow is an indirect branch. The data (addresses and values) traced with this instruction must be treated as invalid, but data traced for other instructions will be unaffected. It is always possible for invalid trace to be detected by the tools when the first instruction is an indirect branch, except in the case of an SWPB instruction when a 16-bit trace port is in use. If you are using tools which detect this, such as ARM’s Trace Debug Tools, the data trace can be treated as valid if the first instruction following the overflow is an indirect branch and no error has been detected. The next instruction to have data traced does not occur until after the next indirect branch. The data traced with the first instruction must be treated as invalid, but data traced for future instructions is unaffected. It is not always possible for the tools to detect the error. Other instructions have data traced before the next indirect branch, and only data addresses are being traced. The data addresses must be treated as invalid for the first instruction, but will be valid for the instructions which follow. Another instruction has data traced before the next indirect branch, and either only data values are being traced, or the first instruction following the overflow is an MRRC or MCRR. The data values traced with all the instructions up to the next indirect branch must be treated as invalid. Data values traced after the next indirect branch are unaffected by this erratum and will be valid Another instruction has data traced before the next indirect branch, and data values and addresses are both being traced. The data values and addresses traced with all instructions before the next indirect branch must be treated as invalid. Data addresses traced for instructions after the next indirect branch, but before the next full 32-bit data address, must also be treated as invalid. The first data address output after each trace gap is a full 32-bit address, after which a full data address is forced if one has not been output for 1024 cycles.

While most tools do not report when a full data address has been output, if a data address differs from the previous data address traced in bits [31:28], then a full data address would have been output, allowing full data addresses that have not been periodically forced to be detected by the user. When a full data address cannot be detected in this way the user must either find the first data address that is at least 1024 cycles after the first instruction traced following the overflow, or treat all data addresses as invalid until the next gap in the trace. Workaround This workaround is for tool vendors only and must be read in conjunction with the Embedded Trace Macrocell Specification (ARM IHI 0014). Development tool vendors can implement the above checks automatically in the trace tools, so that all data given to the user is guaranteed to be correct. In particular: ■ The target address of branches is always known, so the comparison of the addresses before and after overflow can be accurate. ■ The tools must detect when invalid trace is caused by this erratum, and not cause instruction trace to be lost as a result. ■ The tools can detect when the first instruction after overflow is an indirect branch (traced with a PIPESTAT of BD) and not an SWPB with a 16-bit trace port, and not treat the data trace as invalid unless the branch address is earlier than expected. An SWPB cannot be reliably detected in this way because of the 1-byte gap that is sometimes left on a 16-bit trace port to align instruction addresses. ■ Where data addresses are invalid until the next synchronization point, the tools should treat data addresses as valid following the next 5-byte data address output instead. There is no known way to prevent the erratum from occurring, other than increasing the amount of filtering performed, particularly by ViewData, to reduce the chance of an overflow occurring. Implications of workaround In some circumstances substantial data trace, and in particular data addresses, might be lost. Data might be treated as invalid when it is not, particularly in systems where this erratum never or rarely occurs. As a result, it is recommended that if the workaround is implemented it is possible to turn it off.

16 Altera Corporation

A.2.2 Execution status unknown prior to an interrupt or prefetch abort—Category 2 The trace port protocol allows for each instruction traced to be reported with a corresponding branch address to indicate the address of the next instruction. If this branch address is not output then the trace tools must calculate the address of the next instruction. If a branch address is output then the PIPESTAT pins of the trace port will indicate Branch Executed (BE) or Branch with Data (BD). When an interrupt or prefetch abort occurs, the instruction which follows the last instruction to be executed should be traced (even though it did not execute) with a branch address to the relevant exception vector. In the case of interrupts this is often referred to as the interrupted instruction. The trace tools must recognize that the branch was to an interrupt or prefetch abort exception vector, and correctly treat that instruction as having not executed. In this way, the trace can reliably indicate if the last instruction executed failed its condition codes. Sometimes the ETM does not trace this extra instruction but instead traces the last instruction executed as having branched to the exception vector.

Table 4 shows an example of incorrect trace caused by this erratum. Table 5 shows an example where this erratum does not occur. Table 4. Example of incorrect trace behavior on interrupt

18 Altera Corporation

The conditions under which this erratum occurs are not easily predicted. It never occurs if the last executed instruction failed its condition codes. Implications The last instruction executed before an interrupt or prefetch abort might be missing from the trace. Some tools always report the extra instruction traced as having executed, in which case the user will instead see an extra instruction reported before an interrupt or prefetch abort when this erratum does not occur. If tracing continues until after the exception handler returns, the user can use the address of the first instruction executed upon returning from the exception to determine the actual behavior. Workaround for tools vendors Since the execution status is unknown, development tools cannot reliably report the last instruction executed before an abort or an interrupt. The development tools must display the last instruction traced with its execution status shown as ‘unknown’, rather than suppress it as defined in the trace port protocol. Implications of workaround It is not possible to determine which instruction was executed immediately before an interrupt or prefetch abort, without referring to the last instruction traced before the interrupt.

A.2.3 Instruction displayed befor e and after overflow—Category 2 When the FIFO overflows, the last instruction to be traced immediately before overflow may be repeated on recovery from overflow. Conditions The instruction must be executing when the overflow occurs and remain so until trace is re-enabled following overflow. This generally only arises if a large number of wait states occur. Consequently it should only occur in cached systems during a cache miss, or when using a very slow memory system. Since the ETM FIFOFULL signal attempts to preemptively insert processor wait states to prevent the FIFO from overflowing, having FIFOFULL enabled can also increase the occurrence of this problem. Implications It can appear that an instruction is executed twice when it was only executed once. Workaround for tools vendors The development tools should be modified to discard the instruction before the overflow, only displaying the instruction after overflow when the addresses of the instructions before and after overflow match. Occasionally this would cause an instruction to be discarded unnecessarily, but a much larger number of instructions would already have been discarded due to the overflow. It is important that the instruction before overflow is the one to be discarded, and not the one following overflow recovery, in case the erratum is falsely detected. If trace is turned off during overflow (TraceEnable goes LOW), then enabled again (TraceEnable goes HIGH) some time after overflow recovery, the first instruction to be traced following overflow may be significant and must be traced. Implications of workaround An extra instruction will occasionally be lost during an overflow occurring in a loop. This will not be detectable by the user.

20 Altera Corporation

A.2.4 Address range cannot include 0xFFFFFFFF—Category 2 There is no way to define a range which includes 0xFFFFFFFF. Ranges are defined to be exclusive of the upper address, so a range with an upper address of 0xFFFFFFFF only includes addresses up to 0xFFFFFFFE. Conditions All. Implications The ability to monitor accesses to this address is seriously reduced. Workaround To monitor accesses to 0xFFFFFFFF, the upper address on the range must be set to 0xFFFFFFFF, with the size mask set to clear bits 1:0 (bits 4:3 of the access type register must be set to b11). This causes the upper bound of the address range never to match, and so the range has no upper limit and accesses to 0xFFFFFFFF are monitored correctly. Implications of workaround No implications. This will become part of the ETM specification. A.2.5 Extra CPRT data traced—Category 2 The ETM specification states that CPRT data (data transfers between ARM processor registers and coprocessor registers, which are caused by the instructions MRC, MCR, MRRC, and MCRR) must be traced if and only if the MonitorCPRT bit is set (bit 1 of register 0x00, the control register). Under some circumstances CPRT data can be traced when this bit is not set.

This occurs when both of the following are true: ■ ViewData is enabled. ■ Either data value or data address tracing are enabled (bits 3:2 of register 0x00, the control register). Implications Extra CPRT data is traced. Since the number of such transfers is relatively small, the amount of extra data generated should not be significant. As there is no requirement for the tools to correctly handle CPRT data traced when the MonitorCPRT bit is not set, this may result in unexpected behavior. Workaround If this erratum causes an error in the development tools, the user must always enable coprocessor register transfer tracing. The tools must be able to handle CPRT data traced even when no CPRT data was expected. If this the extra trace is deemed to be confusing to the user, the tools can ignore CPRT data when CPRT data tracing has been disabled. Implications of workaround A small amount of bandwidth may be wasted. A.2.6 Stall cycles reported on wrong instruction—Category 2 The timestamps or cycle numbers, if captured, might not truly reflect the number of cycles taken by each instruction. Stall cycles which cause an instruction to take longer than the minimum time to execute might be reported on an earlier instruction.

22 Altera Corporation

trace to be captured on every cycle during a trace region. saving timestamps with each cycle of trace. number of cycles taken by individual instructions is not. recommends that the latest revision of ETM9 is used in all new designs. Table 6. Example of correct and incorrect trace in the presence of stalls (Part 1 of 2)

be extremely useful to some users in debugging system level issues. documented in the Technical Reference Manual for the core.

514 IE for 100C IE for 1010

515 IE for 1010 IE for 1014

516 IE for 1014 IE for 1018

517 IE for 1018 WT Stall should be observed in line with other

518 IE for 101C IE for 101C

519 IE for 1020 IE for 1020

520 WT WT Stalls caused by the processor are correctly

521 WT WT

522 IE for 1024 IE for 1024 Instruction traced upon completion

Table 6. Example of correct and incorrect trace in the presence of stalls (Part 2 of 2)

24 Altera Corporation

regarded as a complete workaround. Table 7. Example of how to calculate the correct location of a stall (Part 1 of 2) 611 2024 ADD r2,r2,#1 WT (wait) WT Only one stall was predicted for 2004. One must be an external stall. it on 2018, the second on 201C. Remove it and try to place later.

612 WT IE for 2004

613 IE for 2004 IE for 2008

614 IE for 2008 WT

615 WT WT

616 WT IE for 200C

617 IE for 200C IE for 2018 The stall could correspond to 2018 in

not cause an external stall.

Note: If 2018 is also an LDR, rather than an ADD, then it would not be possible to determine which of the two instructions 2018 or 201C caused the stall. A.2.7 FIFOFULL LOW for one cycle during overflow—Category 3 Although FIFOFULL correctly becomes asserted when the space available in the FIFO is less than the minimum value specified in the FIFOFULL Level register of the ETM (register 0x0b), it incorrectly becomes de- asserted for a single cycle when the FIFO overflows. Conditions This occurs for one cycle, on the same cycle in which the FIFO overflows. Implications One extra cycle of trace can be lost during FIFO overflow. Since this case only occurs when overflow is already about to occur, the ability of FIFOFULL to prevent overflow is unaffected. Workaround None required. The erratum causes the loss of an extra cycle of trace when there is an overflow, so the effect is not significant. Implications of workaround No implications.

618 IE for 2018 WT The stall is far more likely to

correspond to 201C, as this causes a LDR to on-chip memory. We can therefore deduce that this LDR caused precisely 1 stall cycle.

619 IE for 201C IE for 201C

620 IE for 2020 IE for 2020 The stall could not correspond to this

load, as it is not 6 cycles ahead of a detected external stall in the trace.

621 IE for 2024 IE for 2024 Note that the total number of cycles

taken for the sequence of instructions is reported correctly. Table 7. Example of how to calculate the correct location of a stall (Part 2 of 2)

26 Altera Corporation

A.2.8 Extra instruction traced prior to debug entry—Category 3 An instruction selected as a breakpoint may be traced prior to debug entry, even though it was not executed. It is flagged as having failed its condition codes, regardless of whether it is conditional. Conditions This has been observed in devices based on the ARM9TDMI (for example the ARM9TDMI, ARM920T, and ARM922T cores) only. It has not been observed in devices based on the ARM9E (for example the ARM9E-S, ARM966E-S, and ARM946E-S cores). Implications It will appear to the user that the breakpoint occurred at the wrong time. Workaround No workaround is known. Implications of workaround No implications. Correction No correction is planned.

A.3 Errata for the ARM922T Processor Core A.3.1 LDM of user mode registers (ARM9TDMI–8)—Category 2 ARM9 Bug tracking database entry : CPC00_CAM_000013 Summary Under specific conditions, a LDM to user mode registers will not operate correctly. These instructions take the form: These instructions are only used in system code and not in application code. A LDM to user mode registers performs a load to the user mode registers whilst the processor is in a privileged mode. Under specific conditions (see below), this instruction will fail to operate correctly. This results in not all the registers in the register list being written correctly. It may also cause further failures, dependent on the construction of the memory system, since the data memory request signals are driven in an incorrect manner in the failing situation. Example of failing instruction LDM sp,{sp,lr}^ Conditions This errata exists in the following circumstances: A LDM to user mode registers, where: 1. The base register is register 8 or greater and 2. The base register is the first register (lowest register number) in the register list and 3. There is more than one register is in the list.

28 Altera Corporation

Notes: In all privileged modes this errata exists if the base register is 8 or greater. This is not restricted to FIQ mode. Instructions of the form operate correctly since these are not LDM to user mode register instructions. These instructions perform a return from exception. Example of failing instructions LDMIA sp,{sp,lr}^ LDMIA r8,{r8-r10}^ Examples that do NOT fail LDMIA sp,{r8,sp,lr}^ ; Ok, since first register is not the base register LDMIA r5,{r5,sp,lr}^ ; Ok, since base register is < r8 LDMIA sp,{sp}^ ; Ok, since only one register in the list LDMIA sp,{sp,lr,pc}^ ; Ok, since PC in the list and hence is a return from ; exception instruction and not a load of user mode ; registers. Implications This errata only applies to hand crafted assembler code, as the ARM compiler does not generate such instructions. The use of this instruction is typically limited to a few places in exception handlers, thus limiting the scope of this erratum. Work-around This instruction is only used by hand crafted assembler code. The ARM compiler will not generate this instruction. To work-around this errata the LDM should be split into two separate instructions.

e.g. The instruction: LDMIA sp,{sp,lr}^ should be split into LDMIA sp,{sp}^ LDMIA sp,{lr}^ and LDMIA r8,{r8-lr}^ should be split into LDMIA r8,{r8}^ LDMIA r8,{r9-lr}^ A.3.2 Debug Request coincident with Pipeline Hazards (ARM9TDMI–9) —Category 2 Summary The processor may return to normal program execution at an incorrect point if EDBGRQ or the scan chain created debug request is asserted whilst it is performing certain tasks. Conditions There are three scenarios in which this erratum can occur: 1. Debug Request occurs whilst the processor is waiting for a coprocessor instruction to be completed by a coprocessor or 2. Debug Request occurs whilst the recognition of a Data Abort is in progress or 3. Debug Request occurs whilst the recognition of an instruction causing a watchpoint is in progress.

1 Recognition of a Data Abort is said to be in progress if the last

memory access asserted the DABORT signal, but the processor has not yet begun execution at the Data Abort vector.

30 Altera Corporation

1 Recognition of a watchpoint is said to be in progress if the last

memory access caused a watchpoint, but debug entry has not yet completed. If the above conditions are met then the debug entry mechanism fails to behave in the defined manner and the device may return from debug and execute from an incorrect address. Implications For each scenario the following implications are expected given the above conditions: Busy-waiting Coprocessor Instructions In this form the debug request supersedes the currently executing coprocessor instruction, which would normally not occur. As such the PC is not the correct value as debug entry proceeds. Correspondingly, on return from debug the standard return address calculation produces an incorrect address and thus unintended or unpredictable device behaviour may result. Data Aborts In this form the debug request causes correct debug entry and exit. However, the link register address calculation for the return from the Data Abort handler is incorrect. Correspondingly, on return from the Data Abort handler unintended or unpredictable device behaviour may result. Watchpoints In this form the debug request causes debug entry first, but the watchpoint is still pending and has yet to execute the next instruction before it takes full effect. As debug entry has already occurred this next instruction will be the first instruction within debug mode to be executed. After this instruction executes, debug entry occurs for a second time, even though the device is already in debug, and results in the premature exiting of debug. Consequently, the return from debug is to an incorrect address and thus unintended or unpredictable device behaviour may result.

There is no practical workaround for this erratum. This is due to the difficulty in getting a debugging tool to recognise the symptoms of this erratum and take the appropriate corrective action. However the likelihood of failure with this mechanism is extremely low and the impact of failure is also low as it affects debugging operations only, therefore there is no plan to revise the design to resolve this erratum. A.3.3 Data Abort and Watchpoint with Breakpoint Following (ARM9TDMI–10)—Category 2 Summary The processor may fail to execute the abort handler if a data abort occurs on a watchpointed instruction and a breakpoint is in the execution pipeline. Conditions The conditions for this erratum are: 1. An instruction that causes both a Data Abort and a watchpoint to occur and 2. The execution of the following instruction will cause a breakpoint to occur

1 There should be no data dependency between the two

instructions such that a pipeline interlock occurs. If there is such data dependency then the processor behaves correctly. If the above conditions are met then the Data Abort may be missed. Implications In this erratum Data Abort entry is halted by debug entry and this causes the state indicating a Data Abort to be lost on return from debug. Hence the Data Abort handler will fail to be invoked. This may result in unintended or unpredictable device behaviour.

32 Altera Corporation

There is no practical workaround for this erratum. This is due to the difficulty in getting a debugging tool to recognise the symptoms of this erratum and take the appropriate corrective action. However the likelihood of failure with this mechanism is extremely low and the impact of failure is also low as it affects debugging operations only, therefore there is no plan to revise the design to resolve this erratum. A.3.4 Watchpoint coincident with Debug Request (ARM9TDMI–11)— Category 2 Summary The processor can falsely exit debug state and continue execution if EDBGRQ or the scan chain created debug request is asserted whilst debug entry is occurring. Conditions A combination of two conditions is required to cause this erratum: 1. Debug request is asserted and 2. An instruction that generates a watchpoint is executing If the above conditions are met then the debug entry mechanism fails to behave in the defined manner and the device may return from debug and execute from the incorrect address. Implications In this erratum, the debug request takes affect before the complete recognition of the watchpoint. This may result in unreliable debug entry, the watchpoint being missed and premature exit of debug state. Thus unintended or unpredictable device behaviour may result. Workarounds There is no practical workaround for this erratum. This is due to the difficulty in getting a debugging tool to recognise the symptoms of this erratum and take the appropriate corrective action. However the likelihood of failure with this mechanism is extremely low and the impact of failure is also low as it affects debugging operations only, therefore there is no plan to revise the design to resolve this erratum.

A.3.5 Register controlled shift data operations where the destination is the PC (ARM9TDMI–1)—Category 3 ARM9 Bug tracking database entry : CPC00_CAM_000001 Summary A data operation with a register controlled shift to the PC may calculate an incorrect result This fault is exhibited by any data operation involving a register-specified shift with the Program Counter as the destination. This is in effect a calculated branch, with an unusual branch address calculation. The branch target address calculated by the instruction is incorrect. The ARM C compiler will not generate this instruction. Other compilers are extremely unlikely to produce this instruction, as no standard high level languages source code constructs which would map to this instruction. It is also extremely unlikely that this instruction has been used in assembler code, as is explained below. Conditions Exists for any instruction that involves a register-specified shift or rotate operation with the PC as the destination for the resulting data. The fault does not occur for an immediate specified shift or rotate to the PC. Implications Data operations involving a register controlled shift and where the destination register is the PC have an unpredictable behaviour on an ARM9TDMI processor core and any processor containing an ARM9TDMI; for example ARM920T. The current ARM compiler cannot generate instructions of this class and so this would only be encountered in hand coded assembler. ARM’s software staff have considered possible uses for such an instruction in assembler code, and have only found one theoretical use for this instruction, which is a strange branch table described below. For these reasons this erratum is not expected to cause any restrictions or problems in using the ARM9TDMI.

Copyright © 2002 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the stylized Altera logo, specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. All other product or service names are the property of their respective holders. Altera products are protected under numerous U.S. and foreign patents and pending applications, mask work rights, and copyrights. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera’s standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. Errata Sheet - Appendix A

34 Altera Corporation

101 Innovation Drive

San Jose, CA 95134 (408) 544-7000 http://www.altera.com Applications Hotline: (800) 800-EPLD Literature Services: lit_req@altera.com Examples: MOV(S) PC, Rm, <SHIFTOP> Rs ADD(S) PC, Rn, Rm, <SHIFTOP> Rs The only theoretical use for these instructions which has been suggested would be for a branch table that was organised in powers of 2. MOV r0,#0x100 MOV r1,#0x4 ADD PC,r0,r1, LSL r2 0x1004: Code seq1 : 1 instruction 0x1008 -> 0x100C: Code seq2:2 instructions 0x1010 -> 0x101C: Code seq3:4 instructions 0x1020 -> 0x103C: Code seq4:8 instructions 0x1040 -> 0x107C: Code seq5:16 instructions 0x1080 -> 0x10FC: Code seq6:32 instructions 0x1100 -> 0x11FC: Code seq7:64 instructions 0x1200 -> 0x13FC: Code seq8:128 instructions To date ARM knows of no examples of an application for a branch table organised in such a manner. However, if one was required then an alternative code sequence could be used.