EPX380SX ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com MODEL SELECTION Model Number Input Voltage Output Voltage Output Power EPX380SX 85~265VAC 380VDC 600W POWER FACTOR CORRECTION WITHOUT PFC WITH PFC GENERAL SPECIFICATION World’s Most Advanced Ultra High Density AC- DC Converters 600 Watts, AC Input w/Power Factor Correction 380 VDC Output.
DESCRIPTION
This module accept 85-265VAC and convert it to
380 VDC to power 300VDC input DC -DC
converters. Power factor correction meets low harmonic distortion requirements of IEC 1000-3-2 and the new European EN55022 emissions specification when used with the Model HH-1199-6 EMI filter. This module utilize a boost converter incorporating a solid state series switch for active inrush and short circuit current limiting. The series switch is also used to provide over temperature shutdown with automatic recovery.
FEATURES
- 600Watts
- UL, CSA, & TUV Approved
- Meets New European EN55022 Emissions when used with HH-1199- EMI Filter
- Unity Power Factor
- High Efficiency
- Active Inrush Limiting and Short Circuit Protection
- Very Low Harmonic Distortion
- Auxiliary Supply
- Power Fail Warning Via DC OK Signal
- Load Enable Signal to Control DC-DC Converters
- Very Low Thermal Resistance
- Superior Thermal Design
- 100°C Baseplate Operation
600 WATT
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com 1) POWER 600Watts Derate output power linearly below 105 VAC from 600W at 105 VAC to 400W at 85 VAC. 2) INPUTS Description Min. Typical Max. Condition Input Voltage 85VAC 265VAC Full Range; 50/60Hz Line Frequency 47Hz 63Hz (operation up to 440Hz w/reduced specifications) Power Factor 0.99 Harmonic Distortion <5% (conforming to IEC 1000-3-2) 3) OUTPUT REQUIREMENT: Efficiency 90/94 % (120/240 VAC) typical Inrush Limiting <15 A peak typical 4)PROTECTION: 4.1) SHORT CIRCUIT PROTECTION Trip point 1.8 A (Shutdown, auto. recovery after removal of short) 4.2) THERMAL PROTECTION 105 -110°C (Shutdown, automatic recovery) 4.3) OVERLOAD PROTECTION
415 VDC non-shutdown
4.4) ISOLATION Input -Output Non -isolated Input/Output-Case 2500 VDC 5) ENVIRONMENT: 5.1) Operating temperature: -40 to +100°C Case 6) Thermal Resistance (Case To Ambient): 3.3°C/W
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com 7) SAFETY REQUIREMENTS UL1950, CSA22.2-234-M90, EN 60950 8) LOAD ENABLE Direct interface with DC-DC Converter logic on/off pin 9) DC OK SIGNAL Provides power fail warning when output drops below 355VDC 10) AUXILLARY SUPPLY 14 V @ 10 Ma 11) SYSTEM DIAGRAM 12) OUTLINE DRAWING
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com 13) POWER FACTOR VS. LOAD 14) THERMAL PERFORMANCE 15)EFFICIENCY