DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

The EPL150 series maximises efficiency across the load range and minimises no load power consumption minimising heat dissipation, reducing running costs and enabling compliance with the latest environmental goals and legislation. Fully approved as Class I & Class II for ITE, Industrial and Medical applications the EPL150 provides up to 100 W when convection cooled and up to 150 W when force cooled at just 10 CFM. A 12 V 0.5 A fan supply is included to support force cooled applications. The small footprint, low profile, low noise and comprehensive safety agency approvals allow this versatile product to be used in a wide range of ITE and industrial applications.

  • 100 W Convection/150 W Forced-cooled Ratings
  • 2” by 4” Footprint
  • Low 0.99” Profile
  • Class I & Class II Operation
  • 12 V Fan Output
  • High Efficiency, up to 95%
  • ITE & Medical (BF) Approvals
  • High Power Density
  • Less than 0.5 W No Load Input Power
  • 3 Year Warranty Dimensions: EPL150: w w w .xppow er.com 1 Models & Ratings N otes 1. Requires 10 C FM . 2. M inim um average efficiencies m easured at 25% , 50% , 75% & 100% of 150 W load and 230 VAC input. EPL150 Series AC -D C Pow er Supplies

150 Watts

O utput C urrent Fan O utput Efficiency (2) M odel N um ber C onvection-cooled Forced-cooled (1) 150 W 12.0 V 8.3 3 A 12.50 A 12 V/0.5 A 9 3 % EPL 150PS12 150 W 15.0 V 6 .6 7 A 10.00 A 12 V/0.5 A 9 3 % EPL 150PS15 150 W 18.0 V 5.56 A 8.3 3 A 12 V/0.5 A 9 3 % EPL 150PS18 150 W 24.0 V 4.17 A 6 .25 A 12 V/0.5 A 9 3 % EPL 150PS24 150 W 28.0 V 3 .50 A 5.40 A 12 V/0.5 A 9 3 % EPL 150PS28 150 W 3 6 .0 V 2.7 8 A 4.17 A 12 V/0.5 A 9 3 % EPL 150PS3 6 150 W 48.0 V 2.08 A 3 .10 A 12 V/0.5 A 9 3 % EPL 150PS48 Summary C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input R ange 80 115/23 0 26 4 VA C Derate load from 100% at 9 0 VA C to 9 0% at 85 VA C and 85% at 80 VA C N o L oad Input Pow er 0.5 W Efficiency 9 5 % 23 0 VA C (see fig.1 & 2) O perating T em perature -20 +7 0 °C See derating curve (fig.3 ) EM C C onducted: EN 55011/3 2, C lass B, R adiated: EN 55011/3 2, C lass A (C lass B w ith external core, see EM C Em issions for details) Safety A pprovals C B/EN /U L /C SA for ITE and M edical

C haracteristic M inim um Typical M axim um U nits N otes & C onditions O utput Voltage - V1 12 48 VDC See M odels and R atings table Initial Set A ccuracy ±1 % 50% load, 115/23 0 VA C O utput Voltage A djustm ent-V1 % N one M inim um L oad 0A Start U p Delay 2s 115/23 0 VA C full load. H old U p Tim e 10 20/13 m s M in at full load, 115 VA C . T ypical at 100W /150W Drift ±0.02 % A fter 20 m in w arm up L ine R egulation ±0.5 % 9 0-26 4 VA C L oad R egulation ±0.5 % 0-100% load. T ransient R esponse 4% R ecovery w ithin 1% in less than 500 µs for a 50-7 5% and 7 5-50% load step O ver/U ndershoot 7% Full load R ipple & N oise 1 % pk-pk 20 M H z bandw idth and 10 µF electrolytic capacitator in parallel w ith 0 .1 µF ceram ic capacitator. O vervoltage Protection 110 140 % Vnom , recycle input to reset O verload Protection 110 17 0 % I nom Short C ircuit Protection T rip & R estart T em perature C oefficient 0.02 % /˚C O vertem perature Protection °C M easured internally, A uto R esetting C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input Voltage - O perating 80 115/23 0 26 4 VA C Derate output from 100% at 9 0 VA C to 9 0% at 85 VA C and 85% at 80 VA C Input Frequency 47 50/6 0 6 3 H z Pow er Factor >0.9 23 0 VA C , 100% load EN 6 1000-3 -2 class A Input C urrent - Full L oad 2.2/1.1 A 115/23 0 VA C Inrush C urrent 120 A 23 0 VA C cold start, 25 ºC Earth L eakage C urrent 80/140 23 0 µA 115/23 0 VA C /50 H z (T yp), 26 4 VA C /6 0 H z (M ax) N o load Input Pow er 0.5 W Input Protection F3 .15 A /250 V Internal fuse fitted in line and neutral. EPL150 Series w w w .xppow er.com 2 AC -D C Pow er Supplies

w w w .xppow er.com AC -D C Pow er Supplies General C haracteristic M inim um Typical M axim um U nits N otes & C onditions Efficiency 9 4 % 23 0 VA C (see fig. 1 & 2) Isolation: Input to O utput Input to G round O utput to G round

4000 VA C 2 M O PP

1500 VA C 1 M O PP

Patient L eakage 50 µA A t 26 4 VA C , 50 H z Sw itching Frequency 40 13 0 kH z PFC 50 9 5 kH z M ain converter Pow er Density 18.9 /12.6 W /in 3 Forced/convection-cooled M ean Tim e Betw een Failure 3 00 kH rs M IL -H DBK -217 F , N otice 2 +25 °C G B W eight 0.43 (19 5) lb(g) Efficiency Vs Load Figure 1 EPL150 PS24 10 0 W Figure 2 EPL150 PS24 150 W 60% 70% 65% 75% 85% 95% 80% 90% 100% 10 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 Efficiency Load (%) 115Va c 230V ac 65% 75% 85% 95% 115Va c 230V ac 60% 70% 80% 90% 100% 10 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 Efficiency Load (%)

EMC: Emissions EMC: Immunity EPL150 Series AC -D C Pow er Supplies w w w .xppow er.com 4 Environmental C haracteristic M inim um Typical M axim um U nits N otes & C onditions O perating T em perature -20 +7 0 °C See derating curve, fig.3 Storage T em perature -40 +85 °C C ooling 10 C FM Forced-cooled > 150W H um idity 5 9 5 % R H N on-condensing O perating A ltitude 5000 m Shock ±3 x 3 0g shocks in each plane, total 18 shocks. 3 0g = 11m s (+/- 0.5m secs), half sine. C onform s to EN 6 006 8-2-27 Vibration Single axis 10-500 H z at 2g sw eep and endurance at resonance in all 3 planes. C onform s to EN 6 006 8-2-6 -20 0 +70+50 100 Ambient Temperature (ºC) Output Load (%) Figure 3 Tem perature D erating C urve Phenom enon Standard Test Level C riteria N otes & C onditions C onducted EN 55011/22 C lass B R adiated EN 55011/22 C lass A C lass B w ith K ing C ore K 5B R C 13 x 23 x 7 on input cable and K 5B T 25 x 12 x 5 on output cable. H arm onic C urrent EN 6 1000-3 -2 C lass A Voltage Functions EN 6 1000-3 -3 Phenom enon Standard Test Level C riteria N otes & C onditions M edical Device EM C IEC 6 06 01-1-2 Ed.4.0 : 2014 as below L ow Voltage PSU EM C EN 6 1204-3 H igh severity level as below ESD EN 6 1000-4-2 4A ±8kV contact, ±15kV air R adiated EN 6 1000-4-3 3A EFT EN 6 1000-4-4 3A Surges EN 6 1000-4-5 Installation class 3 A C onducted EN 6 1000-4-6 3A M agnetic Fields EN 6 1000-4-8 4A Dips and Interruptions EN 55024 (100 VA C ) Dip >9 5% (0 VA C ), 8.3 m s A Dip 3 0% (7 0 VA C ), 416 m s A Dip >9 5% (0 VA C ), 416 0 m s B EN 55024 (240 VA C ) Dip >9 5% (0 VA C ), 10.0 m s A Dip 3 0% (16 8 VA C ), 500 m s A Dip >9 5% (0 VA C ), 5000 m s B EN 60601-1-2 (100 VAC ) D ip 100% (0 VA C ), 10.0 m s A Dip 100% (0 VA C ), 20 m s B D ip 60% (40 VAC ), 100 m s B D ip 30% (70 VAC ), 500 m s A Dip 100% (0 VA C ), 5000 m s B EN 6 06 01-1-2 (240 VA C ) D ip 100% (0 VA C ), 10.0 m s A Dip 100% (0 VA C ), 20 m s B D ip 60% (96 VAC ), 100 m s A D ip 30% ( 168 VAC ), 500 m s A Dip 100% (0 VA C ), 5000 m s B

EPL150 Series AC -D C Pow er Supplies 5 w w w .xppow er.com Mechanical Details 1. A ll dim ensions show n in inches (m m ). T olerance: ±0.02 (0.5) 2. W eight: XXX lbs (XXX g) approx. N otes Safety Approvals Safety Agency Safety Standard N otes & C onditions C B R eport IEC 60 950 -1-1, IEC 62 368-1 Inform ation Technology U L U L60 950 -1, U L62 368-1 Inform ation Technology TU V EN 62 368-1 Inform ation Technology C B R eport IEC 60 60 1-1 M edical U L ES60 60 1-1 M edical EN EN 60 60 1-1 M edical Isolation Safety Standard N otes & C onditions Prim ary to Secondary 2 x M O PP (M eans of Patient Protection) Prim ary to Earth 1 x M O PP (M eans of Patient Protection) Secondary to Earth 1 x M O PP (M eans of Patient Protection) Suitable for use as B F applied part application 0.83 (21.0) 0.06 (1.6) 1.75 (44.5) 2.00 (50.8) 0.10 (2.5) 0.13 (ø3.2) 4.0 (101.6) CN2 CN3 C13 C2 C52 TR1 CN1 Mou nting screw holes (in 4 positions) 3.75 (95.3) M ates w ith JST VH R -3 N housing and SVH -21T -P1.1 crim ps M ates w ith JST VH R -6 N housing and SVH -21T -P1.1 crim ps M ounting holes m arked w ith m ust be connected to safety earth in C lass I application or connected together in C lass II application. M ates w ith M olex 22-01-1022 housing and 27 59 crim ps C N 2 Pin 1 +Vo Pin 2 +Vo Pin 3 +Vo Pin 4 C om Pin 5 C om Pin 6 C om C N 1 Pin 1 A C -L Pin 2 Pin 3 A C -N C N 3 Pin 1 Fan - Pin 2 Fan +

EPL150 Series AC -D C Pow er Supplies w w w .xppow er.com 29 Nov 17 Figure 4 Estim ated Service Life vs C om ponent Tem perature In order to ensure safe operation of the PSU in the end-use equipm ent, the tem perature of the com ponents listed in the table below m ust not be exceeded. T em perature should be m onitored using therm ocouples placed on the hottest part of the com ponent (out of direct air flow ). See M echanical Details for com ponent locations. The estim ated service life of the EPL 150 is determ ined by the cooling arrangem ents and load conditions experienced in the end application. Due to the uncertain nature of the end application this estim ated service life is based on the actual m easured tem perature of key capacitors w ith in the product w hen installed by the end application, The graph below expresses the estim ated lifetim e based on the tem perature of these key com ponents based on the average tem perature over the lifetim e of the equipm ent. Tem perature M easurem ents (At M axim um Am bient) C om ponent M ax Tem perature °C TR 1 C oil 120°C L 4 C oil 120°C C 13 105°C C 52 105°C C 2 105°C 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 150000 160000 105 9 58 57 56 55 5 C2 C5 2 C1 3 Lifetime (Hrs) C2, C13 & C52 Temperature (ºC) Thermal Considerations Service Life