www.roithner-laser.com 1 EPD-1300-5-0.3 v 1.0 13.11.2013
Description
EPD-1300-5-0.3 is a selective photodiode based on InGaAs with an active area of Ø300 µm, mounted on a lead frame and encapsulated in a standard clear 5 mm epoxy package. The PD is specified with a sensitivity range of 800 – 1750 nm and a peak at 1600 nm. Maximum Ratings Parameter Symbol Values Min. Max. Unit Temperature Coefficient of IPH TC(IPH) 7.4 %/K Operating Temperature TCASE - 40 + 85 °C Storage Temperature TSTG - 40 + 100 °C Optical and Electrical Characteristics (TCASE=25°C) * for information only Parameter Symbol Conditions Values Min. Typ. Max. Unit Sensitive Area Diameter D 300 µm Max. Sensitivity Wavelength (>90%) λP VR=0V 800 1750 nm Peak Sensitivity Wavelength λPeak VR=0V 1600 nm Spectral Bandwidth at 50% ∆λ0.5 VR=0V 680 nm Breakdown Voltage * VR IR=10µA 5 V Dark Current ID VR=5V 15 40 pA Shunt Resistance RTH VR=10mV 3 5 GΩ Responsivity at 1300 nm Sλ VR=0V 0.9 A/W Noise Equivalent Power NEP λ=1300nm 4x10-15 W/√𝐻𝑧 Specific Detectivity D* λ=1300nm 4.5x1012 𝑐𝑚∙√𝐻𝑧∙𝑊−1 Junction Capacitance CJ VR=0V 11 pF Photo Current at 1300 nm * iPH VR=0V EE=1mW/cm² 0.95 µA
www.roithner-laser.com 2 Preformance Characteristics Outline Dimensions All Dimensions in mm Spectral Response (typical) EPD-1300-5-0.3 5 mm epoxy
www.roithner-laser.com 3 Precautions Operation:
- Check your connection circuits before turning on the PD.
- Mind the PD polarity: PD anode is marked by long pin.
- DO NOT connect the PD to the multimeter. Soldering:
- Do avoid overheating of the PD
- Do avoid electrostatic discharge (ESD)
- Do avoid mechanical stress, shock, and vibration
- Do only use non-corrosive flux
- Do not apply current to the PD until it has cooled down to room temperature after soldering Static Electricity: PDs are sensitive to electrostatic discharge (ESD) . Precautions against ESD must be taken when handling or operating these PDs. Surge voltage or electrostatic discharge can result in complete failure of the device. © All Rights Reserved The above specifications are for reference purpose only and subjected to change without prior notice