CIII52001-3.5 © 2012 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as trademarks or service marks are the property of their respective holders as described at www.altera.com/common/legal.html. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. Cyclone III Device Handbook Volume 2 July 2012 Subscribe ISO 9001:2008 Registered 1. Cyclone III Device Datasheet This chapter describes the electric characteristics, switching characteristics, and I/O timing for Cyclone® III devices. A glossary is also included for your reference.
Electrical Characteristics
The following sections provide information about the absolute maximum ratings, recommended operating conditions, DC characteristics, and other specifications for Cyclone III devices. Operating Conditions When Cyclone III devices are implemented in a system, they are rated according to a set of defined parameters. To maintain the highest possible performance and reliability of Cyclone III devices, system designers must consider the operating requirements in this document. Cyclone III devices are offered in commercial, industrial, and automotive grades. Commercial devices are offered in –6 (fastest), –7, and –8 speed grades. Industrial and automotive devices are offered only in –7 speed grade.
1 In this chapter, a prefix associated with the operating temperature range is attached to
the speed grades; commercial with “C” prefix, industrial with “I” prefix, and automotive with “A” prefix. Commercial devices are therefore indicated as C6, C7, and C8 per respective speed grades. Industrial and automotive devices are indicated as I7 and A7, respectively. Absolute Maximum Ratings Absolute maximum ratings define the maximum operating conditions for Cyclone III devices. The values are based on experiments conducted with the device and theoretical modeling of breakdown and damage mechanisms. The functional operation of the device is not implied at these conditions. Table 1–1 lists the absolute maximum ratings for Cyclone III devices. July 2012 CIII52001-3.5
1–2 Chapter 1: Cyclone III Device Datasheet Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 1 Conditions beyond those listed in Table 1–1 cause permanent damage to the device. Additionally, device operation at the absolute maximum ratings for extended periods of time has adverse effects on the device. Maximum Allowed Overshoot or Undershoot Voltage During transitions, input signals may overshoot to the voltage listed in Table 1–2 and undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods shorter than 20 ns. Table 1–2 lists the maximum allowed input overshoot voltage and the duration of the overshoot voltage as a percentage over the lifetime of the device. The maximum allowed overshoot duration is specified as percentage of high-time over the lifetime of the device. Table 1–1. Cyclone III Devices Absolute Maximum Ratings (1) Symbol Parameter Min Max Unit VCCINT Supply voltage for internal logic –0.5 1.8 V VCCIO Supply voltage for output buffers –0.5 3.9 V VCCA Supply voltage (analog) for phase-locked loop (PLL) regulator –0.5 3.75 V VCCD_PLL Supply voltage (digital) for PLL –0.5 1.8 V VI DC input voltage –0.5 3.95 V IOUT DC output current, per pin –25 40 mA VESDHBM Electrostatic discharge voltage using the human body model — ±2000 V VESDCDM Electrostatic discharge voltage using the charged device model — ±500 V TSTG Storage temperature –65 150 °C TJ Operating junction temperature –40 125 °C Note to Table 1–1: (1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the power supply.
1–4 Chapter 1: Cyclone III Device Datasheet Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Recommended Operating Conditions This section lists the functional operation limits for AC and DC parameters for Cyclone III devices. The steady-state voltage and current values expected from Cyclone III devices are provided in Table 1–3. All supplies must be strictly monotonic without plateaus. Table 1–3. Cyclone III Devices Recommended Operating Conditions (1), (2) Symbol Parameter Conditions Min Typ Max Unit VCCINT (3) Supply voltage for internal logic — 1.15 1.2 1.25 V VCCIO (3), (4) Supply voltage for output buffers, 3.3-V operation — 3.135 3.3 3.465 V Supply voltage for output buffers, 3.0-V operation — 2.85 3 3.15 V Supply voltage for output buffers, 2.5-V operation — 2.375 2.5 2.625 V Supply voltage for output buffers, 1.8-V operation — 1.71 1.8 1.89 V Supply voltage for output buffers, 1.5-V operation — 1.425 1.5 1.575 V Supply voltage for output buffers, 1.2-V operation — 1.14 1.2 1.26 V VCCA (3) Supply (analog) voltage for PLL regulator — 2.375 2.5 2.625 V VCCD_PLL (3) Supply (digital) voltage for PLL — 1.15 1.2 1.25 V VI Input voltage — –0.5 — 3.6 V VO Output voltage — 0 — V CCIO V TJ Operating junction temperature For commercial use 0 — 85 °C For industrial use –40 — 100 °C For extended temperature –40 — 125 °C For automotive use –40 — 125 °C tRAMP Power supply ramp time Standard power-on reset (POR) (5) 50 µs — 50 ms — Fast POR (6) 50 µs — 3 ms — IDiode Magnitude of DC current across PCI-clamp diode when enabled —— — 1 0 m A Notes to Table 1–3: (1) V CCIO for all I/O banks must be powered up during device operation. All VCCA pins must be powered to 2.5 V (even when PLLs are not used), and must be powered up and powered down at the same time. (2) V CCD_PLL must always be connected to VCCINT through a decoupling capacitor and ferrite bead. (3) The V CC must rise monotonically. (4) All input buffers are powered by the V CCIO supply. (5) POR time for Standard POR ranges between 50–200 ms. Each in dividual power supply should reach the recommended operating range within 50 ms. (6) POR time for Fast POR ranges between 3–9 ms. Each individual power supply should reach the recommended operating range within 3 ms.
Chapter 1: Cyclone III Device Datasheet 1–5 July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 DC Characteristics This section lists the I/O leakage current, pin capacitance, on-chip termination (OCT) tolerance, and bus hold specifications for Cyclone III devices. Supply Current Standby current is the current the device draws after the device is configured with no inputs or outputs toggling and no activity in the device. Use the Excel-based early power estimator (EPE) to get the supply current estimates for your design because these currents vary largely with the resources used. Table 1–4 lists I/O pin leakage current for Cyclone III devices. f For more information about power estimation tools, refer to the PowerPlay Early Power Estimator User Guide and the PowerPlay Power Analysis chapter in the Quartus II Handbook. Bus Hold Bus hold retains the last valid logic state after the source driving it either enters the high impedance state or is removed. Each I/O pin has an option to enable bus hold in user mode. Bus hold is always disabled in configuration mode. Table 1–5 lists bus hold specifications for Cyclone III devices. Table 1–4. Cyclone III Devices I/O Pin Leakage Current (1), (2) Symbol Parameter Conditions Min Typ Max Unit II Input pin leakage current V I = 0 V to VCCIOMAX –10 — 10 A IOZ Tristated I/O pin leakage current VO = 0 V to VCCIOMAX –10 — 10 A Notes to Table 1–4: (1) This value is specified fo r normal device operation. The value varies during device power-up. This applies for all (2) 10 A I/O leakage current limit is applicable when the internal clamping diode is off. A higher current can be the observed when the diode is on. Table 1–5. Cyclone III Devices Bus Hold Parameter (Part 1 of 2) (1) Parameter Condition VCCIO (V) Min Max Min Max Min Max Min Max Min Max Min Max Bus-hold low, sustaining current V IN > VIL (maximum) 8 — 1 2 — 3 0—5 0—7 0—7 0— A Bus-hold high, sustaining current VIN < VIL
1–6 Chapter 1: Cyclone III Device Datasheet Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 OCT Specifications Table 1–6 lists the variation of OCT without calibration across process, temperature, and voltage. OCT calibration is automatically performed at device power-up for OCT enabled I/Os. Table 1–7 lists the OCT calibration accuracy at device power-up. Bus-hold low, overdrive current
0 V < V
IN < VCCIO — 125 — 175 — 200 — 300 — 500 — 500 A Bus-hold high, overdrive current Bus-hold trip Note to Table 1–5: (1) The bus-hold trip points are based on calc ulated input voltages from the JEDEC standard. Table 1–5. Cyclone III Devices Bus Hold Parameter (Part 2 of 2) (1) Parameter Condition VCCIO (V) Min Max Min Max Min Max Min Max Min Max Min Max Table 1–6. Cyclone III Devices Series OCT without Calibration Specifications Description V CCIO (V) Resistance Tolerance UnitCommercial Max Industrial and Automotive Max Series OCT without calibration 3.0 ±30 ±40 % 2.5 ±30 ±40 % 1.8 +40 ±50 % 1.5 +50 ±50 % 1.2 +50 ±50 % Table 1–7. Cyclone III Devices Series OCT with Calibration at Device Power-Up Specifications Description V CCIO (V) Calibration Accuracy Unit Commercial Max Industrial and Automotive Max Series OCT with calibration at device power-up 3.0 ±10 ±10 % 2.5 ±10 ±10 % 1.8 ±10 ±10 % 1.5 ±10 ±10 % 1.2 ±10 ±10 %
Chapter 1: Cyclone III Device Datasheet 1–7 July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 The OCT resistance may vary with the variation of temperature and voltage after calibration at device power-up. Use Table 1–8 and Equation 1–1 to determine the final OCT resistance considering the variations after calibration at device power-up. Table 1–8 lists the change percentage of the OCT resistance with voltage and temperature. Table 1–8. Cyclone III Devices OCT Variation After Calibration at Device Power-Up Nominal Voltage dR/dT (%/°C) dR/dV (%/mV) 3.0 0.262 –0.026 2.5 0.234 –0.039 1.8 0.219 –0.086 1.5 0.199 –0.136 1.2 0.161 –0.288 Equation 1–1. RT = (T2 – T1) × dR/dT (8) For Rx > 0; MFx = Rx/100 + 1 (10) MF = MFV × MFT (11) Rfinal = Rinitial × MF (12) Notes to Equation 1–1: (1) T 2 is the final temperature. (2) T 1 is the initial temperature. (3) MF is multiplication factor. (4) R final is final resistance. (5) R initial is initial resistance. (6) Subscript × refers to both V and T. (7) RV is variation of resistance with voltage. (8) RT is variation of resistance with temperature. (9) dR/dT is the change percentage of resistance wi th temperature after calibration at device power-up. (10) dR/dV is the change percentage of resistance with voltage after calibration at device power-up. (11) V2 is final voltage. (12) V1 is the initial voltage.
1–8 Chapter 1: Cyclone III Device Datasheet Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Example 1–1 shows you the example to calculate the change of 50 I/O impedance from 25°C at 3.0 V to 85°C at 3.15 V: Pin Capacitance Table 1–9 lists the pin capacitance for Cyclone III devices. Example 1–1. Because RV is negative, Because RT is positive, MFT = 15.72/100 + 1 = 1.157 MF = 0.963 × 1.157 = 1.114 Rfinal = 50 × 1.114 = 55.71 Table 1–9. Cyclone III Devices Pin Capacitance Symbol Parameter Typical – QFP Typical – FBGA Unit CIOTB Input capacitance on top/bottom I/O pins 7 6 pF CIOLR Input capacitance on left/right I/O pins 7 5 pF CLVDSLR Input capacitance on left/right I/O pins with dedicated LVDS output 87 p F CVREFLR (1) Input capacitance on left/right dual-purpose VREF pin when used as VREF or user I/O pin 21 21 pF CVREFTB (1) Input capacitance on top/bottom dual-purpose VREF pin when used as VREF or user I/O pin 23 (2) 23 (2) pF CCLKTB Input capacitance on top/bottom dedicated clock input pins 76 p F CCLKLR Input capacitance on left/right dedicated clock input pins 6 5 pF Notes to Table 1–9: (1) When VREF pin is used as regular input or output, a reduced performance of toggle rate and tCO is expected due to higher pin capacitance. (2) C VREFTB for EP3C25 is 30 pF.
Chapter 1: Cyclone III Device Datasheet 1–9 July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 Internal Weak Pull-Up and Weak Pull-Down Resistor Table 1–10 lists the weak pull-up and pull-down resistor values for Cyclone III devices. Hot Socketing Table 1–11 lists the hot-socketing specifications for Cyclone III devices. Table 1–10. Cyclone III Devices Internal Weak Pull-Up and Weak Pull-Down Resistor (1) Symbol Parameter Conditions Min Typ Max Unit R_PU Value of I/O pin pull-up resistor before and during configuration, as well as user mode if the programmable pull-up resistor option is enabled V VCCIO = 3.0 V ± 5% (2), (3) 72 8 4 7 k VCCIO = 2.5 V ± 5% (2), (3) 83 5 6 1 k VCCIO = 1.8 V ± 5% (2), (3) 10 57 108 k VCCIO = 1.5 V ± 5% (2), (3) 13 82 163 k VCCIO = 1.2 V ± 5% (2), (3) 19 143 351 k R_PD Value of I/O pin pull-down resistor before and during configuration VCCIO = 3.3 V ± 5% (4) 61 9 3 0 k VCCIO = 3.0 V ± 5% (4) 62 2 3 6 k VCCIO = 2.5 V ± 5% (4) 62 5 4 3 k VCCIO = 1.8 V ± 5% (4) 73 5 7 1 k VCCIO = 1.5 V ± 5% (4) 85 0 1 1 2 k Notes to Table 1–10: (1) All I/O pins have an option to enable weak pull-up except configuration, test, and JTAG pin. Weak pull-down feature is only available for JTAG TCK. (2) Pin pull-up resistance values may be lower if an external source drives the pin higher than VCCIO. (3) R _PU = (VCCIO –V I)/IR_PU Minimum condition: –40°C; VCCIO = VCC + 5%, VI = VCC + 5% – 50 mV; Typical condition: 25°C; VCCIO = VCC, VI = 0 V; Maximum condition: 125°C; VCCIO = VCC – 5%, VI = 0 V; in which VI refers to the input voltage at the I/O pin. (4) R _PD = VI/IR_PD Minimum condition: –40°C; VCCIO = VCC + 5%, VI = 50 mV; Typical condition: 25°C; VCCIO = VCC, VI = VCC –5 % ; Maximum condition: 125°C; VCCIO = VCC – 5%, VI = VCC – 5%; in which VI refers to the input voltage at the I/O pin. Table 1–11. Cyclone III Devices Hot-Socketing Specifications Symbol Parameter Maximum IIOPIN(DC) DC current per I/O pin 300 A IIOPIN(AC) AC current per I/O pin 8 mA (1) Note to Table 1–11: (1) The I/O ramp rate is 10 ns or more. For ramp rates faster than 10 ns, |IIOPIN| = C dv/dt, in which C is I/O pin capacitance and dv/dt is the slew rate.
1–10 Chapter 1: Cyclone III Device Datasheet Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Schmitt Trigger Input Cyclone III devices support Schmitt trigger input on TDI, TMS, TCK, nSTATUS, nCONFIG, nCE, CONF_DONE, and DCLK pins. A Schmitt trigger feature introduces hysteresis to the input signal for improved noise immunity, especially for signal with slow edge rate. Table 1–12 lists the hysteresis specifications across supported VCCIO range for Schmitt trigger inputs in Cyclone III devices. I/O Standard Specifications The following tables list input voltage sensitivities (VIH and VIL), output voltage (VOH and VOL), and current drive characteristics (IOH and IOL) for various I/O standards supported by Cyclone III devices. Table 1–13 through Table 1–18 provide the I/O standard specifications for Cyclone III devices. Table 1–12. Hysteresis Specifications for Schmitt Trigger Input in Cyclone III Devices Symbol Parameter Conditions Minimum Typical Maximum Unit VSCHMITT Hysteresis for Schmitt trigger input VCCIO = 3.3 V 200 — — mV VCCIO = 2.5 V 200 — — mV VCCIO = 1.8 V 140 — — mV VCCIO = 1.5 V 110 — — mV Table 1–13. Cyclone III Devices Single-Ended I/O Standard Specifications (1), (2) I/O Standard VCCIO (V) V IL (V) V IH (V) V OL (V) V OH (V) IOL (mA) IOH (mA) Min Typ Max Min Max Min Max Max Min 2.5-V LVTTL and 1.8-V LVTTL and VCCIO 0.65 * VCCIO 2.25 0.45 VCCIO – 0.45 2– 2 VCCIO 0.65 * VCCIO VCCIO + 0.3 0.25 * VCCIO 0.75 * VCCIO 2– 2 VCCIO 0.65 * VCCIO VCCIO + 0.3 0.25 * VCCIO 0.75 * VCCIO 2– 2 VCCIO 0.5 * VCCIO VCCIO 0.5 * VCCIO Notes to Table 1–13: (1) For voltage referenced receiver input w aveform and explanation of terms used in Table 1–13, refer to “Single-ended Voltage referenced I/O Standard” in “Glossary” on page 1–27. (2) AC load CL = 10 pF. (3) For more detail about interfacin g Cyclone III devices with 3.3/3.0/2.5-V LVTTL/LVCMOS I/O standards, refer to AN 447: Interfacing Cyclone III Devices with 3.3/3.0/2.5-V LVTTL and LVCMOS I/O Systems.
Chapter 1: Cyclone III Device Datasheet 1–11 July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 Table 1–14. Cyclone III Devices Single-Ended SSTL and HSTL I/O Reference Voltage Specifications (1) I/O Standard VCCIO (V) V REF (V) V TT (V) (2) Min Typ Max Min Typ Max Min Typ Max SSTL-2
0.04 VREF
0.04 SSTL-18 0.04 HSTL-18 HSTL-15 HSTL-12 Class I, II 1.14 1.2 1.26 0.48 * VCCIO (3) 0.5 * VCCIO (3) 0.52 * VCCIO (3) — 0.5 * VCCIO 0.47 * VCCIO (4) 0.5 * VCCIO (4) 0.53 * VCCIO (4) Notes to Table 1–14: (1) For an explanation of terms used in Table 1–14, refer to “Glossary” on page 1–27. (2) V TT of transmitting device must track VREF of the receiving device. (3) Value shown refers to DC input reference voltage, VREF(DC). (4) Value shown refers to AC input reference voltage, V REF(AC). Table 1–15. Cyclone III Devices Single-Ended SSTL and HSTL I/O Standards Signal Specifications I/O Standard VIL(DC) (V) V IH(DC) (V) V IL(AC) (V) V IH(AC) (V) V OL (V) V OH (V) IOL (mA) IOH (mA)Min Max Min Max Min Max Min Max Max Min SSTL-2 Class I — VREF – 0.18 VREF + 0.18 —— VREF – 0.35 VREF + 0.35 — VTT – 0.57 VTT + 0.57 8.1 –8.1 SSTL-2 Class II — VREF – 0.18 VREF + 0.18 —— VREF – 0.35 VREF + 0.35 — VTT – 0.76 VTT + 0.76 16.4 –16.4 SSTL-18 Class I — VREF – 0.125 VREF + 0.125 —— VREF – 0.25 VREF + 0.25 — VTT – 0.475 VTT + 0.475 6.7 –6.7 SSTL-18 Class II — VREF – 0.125 VREF + 0.125 —— VREF – 0.25 VREF + 0.25 —0 . 2 8 VCCIO – 0.28 13.4 –13.4 HSTL-18 Class I — VREF – 0.1 VREF + 0.1 —— VREF – 0.2 VREF + 0.2 —0 . 4 VCCIO – 0.4 8– 8 HSTL-18 Class II — VREF – 0.1 VREF + 0.1 —— VREF – 0.2 VREF + 0.2 —0 . 4 VCCIO – 0.4 16 –16 HSTL-15 Class I — VREF – 0.1 VREF + 0.1 —— VREF – 0.2 VREF + 0.2 —0 . 4 VCCIO – 0.4 8– 8 HSTL-15 Class II — VREF – 0.1 VREF + 0.1 —— VREF – 0.2 VREF + 0.2 —0 . 4 VCCIO – 0.4 16 –16 HSTL-12 Class I –0.15 VREF – 0.08 VREF + 0.08 VCCIO + 0.15 –0.24 VREF – 0.15 VREF + 0.15 VCCIO + 0.24 0.25 × VCCIO 0.75 × VCCIO 8– 8 HSTL-12 Class II –0.15 VREF – 0.08 VREF + 0.08 VCCIO + 0.15 –0.24 VREF – 0.15 VREF + 0.15 VCCIO + 0.24 0.25 × VCCIO 0.75 × VCCIO 14 –14
1–12 Chapter 1: Cyclone III Device Datasheet Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 f For more illustrations of receiver input and transmitter output waveforms, and for other differential I/O standards, refer to the High-Speed Differential Interfaces in Cyclone III Devices chapter. Table 1–16. Cyclone III Devices Differential SSTL I/O Standard Specifications (1) I/O Standard VCCIO (V) V Swing(DC) (V) V X(AC) (V) VSwing(AC) (V) VOX(AC) (V) Min Typ Max Min Max Min Typ Max Min Max Min Typ Max SSTL-2 + 0.2 0.7 VCCI O VCCIO/2 – 0.125 — VCCIO/2 + 0.125 SSTL-18 Class I, II 1.7 1.8 1.90 0.25 V CCIO VCCIO/2 – 0.175 — VCCIO/2 + 0.175 0.5 VCCI O VCCIO/2 – 0.125 — VCCIO/2 + 0.125 Note to Table 1–16: (1) Differential SSTL requires a V REF input. Table 1–17. Cyclone III Devices Differential HSTL I/O Standard Specifications (1) I/O Standard VCCIO (V) V DIF(DC) (V) V X(AC) (V) V CM(DC) (V) V DIF(AC) (V) Min Typ Max Min Max Min Typ Max Min Typ Max Mi n Max HSTL-18 HSTL-15 HSTL-12 VCCIO 0.48 * VCCIO — 0.52 * VCCIO 0.3 0.48 * VCCIO Note to Table 1–17: (1) Differential HSTL requires a V REF input. Table 1–18. Cyclone III Devices Differential I/O Standard Specifications (1) (Part 1 of 2) I/O Standard VCCIO (V) V ID (mV) V IcM (V) (2) VOD (mV) (3) VOS (V) (3) Min Typ Max Min Max Min Condition Max Min Typ Max Min Typ Max LVPECL (Row I/Os) (4) 2.375 2.5 2.625 100 — 0.05 D MAX500 Mbps 1.80 700 Mbps 1.80 1.05 D MAX > 700 Mbps 1.55 LVPECL (Column I/Os) (4) 2.375 2.5 2.625 100 — 0.05 D MAX 500 Mbps 1.80 700 Mbps 1.80 1.05 D MAX > 700 Mbps 1.55 LVDS (Row I/Os) 2.375 2.5 2.625 100 — 0.05 D MAX 500 Mbps 1.80 247 — 600 1.125 1.25 1.375 0.55 500 Mbps DMAX 700 Mbps 1.80 1.05 D MAX > 700 Mbps 1.55
Chapter 1: Cyclone III Device Datasheet 1–13 July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 LVDS (Column I/Os) 2.375 2.5 2.625 100 — 0.05 D MAX 500 Mbps 1.80 247 — 600 1.125 1.25 1.3750.55 500 Mbps DMAX 700 Mbps 1.80 1.05 D MAX > 700 Mbps 1.55 BLVDS (Row I/Os) (5) BLVDS (Column I/Os) (5) mini-LVDS (Row I/Os) (6) mini-LVDS (Column I/Os) (6) RSDS® (Row I/Os) (6) RSDS (Column I/Os) (6) PPDS® (Row I/Os) (6) PPDS (Column I/Os) (6) Notes to Table 1–18: (1) For an explanation of terms used in Table 1–18, refer to “Transmitter Output Waveform” in “Glossary” on page 1–27. (2) V IN range: 0 V VIN 1.85 V. (3) R L range: 90 R L 110 . (4) LVPECL input standard is only supported at clock input. Output standard is not supported. (5) No fixed V IN, VOD, and VOS specifications for BLVDS. They are dependent on the system topology. (6) Mini-LVDS, RSDS, and PPDS stan dards are only supported at the output pins for Cyclone III devices. Table 1–18. Cyclone III Devices Differential I/O Standard Specifications (1) (Part 2 of 2) I/O Standard VCCIO (V) V ID (mV) V IcM (V) (2) VOD (mV) (3) VOS (V) (3) Min Typ Max Min Max Min Condition Max Min Typ Max Min Typ Max
1–14 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Power Consumption You can use the following methods to estimate power for a design: ■ the Excel-based EPE. ■ the Quartus II PowerPlay power analyzer feature. The interactive Excel-based EPE is used prior to designing the device to get a magnitude estimate of the device power. The Quartus II PowerPlay power analyzer provides better quality estimates based on the specifics of the design after place-and- route is complete. The PowerPlay power analyzer can apply a combination of user- entered, simulation-derived, and estimated signal activities which, combined with detailed circuit models, can yield very accurate power estimates. f For more information about power estimation tools, refer to the Early Power Estimator User Guide and the PowerPlay Power Analysis chapter in volume 3 of the Quartus II Handbook. Switching Characteristics This section provides the performance characteristics of the core and periphery blocks for Cyclone III devices. All data is final and is based on actual silicon characterization and testing. These numbers reflect the actual performance of the device under worst-case silicon process, voltage, and junction temperature conditions. Core Performance Specifications Clock Tree Specifications Table 1–19 lists the clock tree specifications for Cyclone III devices. Table 1–19. Cyclone III Devices Clock Tree Performance Device Performance Unit C6 C7 C8 EP3C5 500 437.5 402 MHz EP3C10 500 437.5 402 MHz EP3C16 500 437.5 402 MHz EP3C25 500 437.5 402 MHz EP3C40 500 437.5 402 MHz EP3C55 500 437.5 402 MHz EP3C80 500 437.5 402 MHz EP3C120 (1) 437.5 402 MHz Note to Table 1–19: (1) EP3C120 offered in C7, C8, and I7 grades only.
Chapter 1: Cyclone III Device Datasheet 1–15 Switching Characteristics July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 PLL Specifications Table 1–20 describes the PLL specifications for Cyclone III devices when operating in the commercial junction temperature range (0°C to 85°C), the industrial junction temperature range (–40°C to 100°C), and the automotive junction temperature range (–40°Cto 125°C). For more information about PLL block, refer to “PLL Block” in “Glossary” on page 1–27. Table 1–20. Cyclone III Devices PLL Specifications (1) (Part 1 of 2) Symbol Parameter Min Typ Max Unit fIN (2) Input clock frequency 5 — 472.5 MHz fINPFD PFD input frequency 5 — 325 MHz fVCO (3) PLL internal VCO operating range 600 — 1300 MHz fINDUTY Input clock duty cycle 40 — 60 % tINJITTER_CCJ (4) Input clock cycle-to-cycle jitter for FINPFD 100 MHz — — 0.15 UI Input clock cycle-to-cycle jitter for FINPFD < 100 MHz — — ±750 ps fOUT_EXT (external clock output) (2) PLL output frequency — — 472.5 MHz fOUT (to global clock) PLL output frequency (–6 speed grade) — — 472.5 MHz PLL output frequency (–7 speed grade) — — 450 MHz PLL output frequency (–8 speed grade) — — 402.5 MHz t OUTDUTY Duty cycle for external clock output (when set to 50%) 45 50 55 % tLOCK Time required to lock from end of device configuration — — 1 ms tDLOCK Time required to lock dynamically (after switchover, reconfiguring any non-post-scale counters/delays or areset is deasserted) —— 1 m s t OUTJITTER_PERIOD_DEDCLK (5) Dedicated clock output period jitter FOUT 100 MHz — — 300 ps FOUT < 100 MHz — — 30 mUI tOUTJITTER_CCJ_DEDCLK (5) Dedicated clock output cycle-to-cycle jitter FOUT 100 MHz — — 300 ps FOUT < 100 MHz — — 30 mUI tOUTJITTER_PERIOD_IO (5) Regular I/O period jitter FOUT 100 MHz — — 650 ps FOUT < 100 MHz — — 75 mUI tOUTJITTER_CCJ_IO (5) Regular I/O cycle-to-cycle jitter FOUT 100 MHz — — 650 ps FOUT < 100 MHz — — 75 mUI tPLL_PSERR Accuracy of PLL phase shift — — ±50 ps tARESET Minimum pulse width on areset signal. 10 — — ns tCONFIGPLL Time required to reconfigure scan chains for PLLs — 3.5 (6) — SCANCLK cycles
1–16 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Embedded Multiplier Specifications Table 1–21 describes the embedded multiplier specifications for Cyclone III devices. Memory Block Specifications Table 1–22 describes the M9K memory block specifications for Cyclone III devices. Configuration and JTAG Specifications Table 1–23 lists the configuration mode specifications for Cyclone III devices. fSCANCLK scanclk frequency — — 100 MHz Notes to Table 1–20: (1) V CCD_PLL should always be connected to VCCINT through decoupling capacitor and ferrite bead. (2) This parameter is limited in the Quartu s II software by the I/O maximum frequency. The maximum I/O frequency is different for each I/O standard. (3) The V CO frequency reported by the Quartus II software in the PLL summary section of the compilation report takes into consideration the VCO post-scale counter K value. Therefore, if the counter K has a value of 2, the frequency reported can be lower than the fVCO specification. (4) A high input jitter directly affects the PLL output jitter. To have low PLL output clock jitter, you must provide a clean clock source, which is less than 200 ps. (5) Peak-to-peak jitter with a probability level of 10–12 (14 sigma, 99.99999999974404% confidence level). The output jitter specification applies to the intrinsic jitter of the PLL, when an input jitter of 30 ps is applied. (6) With 100 MHz scanclk frequency. Table 1–20. Cyclone III Devices PLL Specifications (1) (Part 2 of 2) Symbol Parameter Min Typ Max Unit Table 1–21. Cyclone III Devices Embedded Multiplier Specifications Mode Resources Used Performance Unit Number of Multipliers C6 C7, I7, A7 C8 9 × 9-bit multiplier 1 340 300 260 MHz 18 × 18-bit multiplier 1 287 250 200 MHz Table 1–22. Cyclone III Devices Memory Block Performance Specifications Memory Mode Resources Used Performance LEs M9K Memory C6 C7, I7, A7 C8 Unit M9K Block FIFO 256 × 36 47 1 315 274 238 MHz Single-port 256 × 36 0 1 315 274 238 MHz Simple dual-port 256 × 36 CLK 0 1 315 274 238 MHz True dual port 512 × 18 single CLK 0 1 315 274 238 MHz Table 1–23. Cyclone III Devices Configuration Mode Specifications Programming Mode DCLK F max Unit Passive Serial (PS) 133 MHz Fast Passive Parallel (FPP) (1) 100 MHz Note to Table 1–23: (1) EP3C40 and smaller density members support 133 MHz.
Chapter 1: Cyclone III Device Datasheet 1–17 Switching Characteristics July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 Table 1–24 lists the active configuration mode specifications for Cyclone III devices. Table 1–25 lists the JTAG timing parameters and values for Cyclone III devices. Periphery Performance This section describes periphery performance, including high-speed I/O, external memory interface, and IOE programmable delay. I/O performance supports several system interfacing, for example, the high-speed I/O interface, external memory interface, and the PCI/PCI-X bus interface. I/O using the SSTL-18 Class I termination standard can achieve up to the stated DDR2 SDRAM interfacing speeds with typical DDR SDRAM memory interface setup. I/O using general-purpose I/O standards such as 3.0-, 2.5-, 1.8-, or 1.5-LVTTL/LVCMOS are capable of a typical 200 MHz interfacing frequency with a 10 pF load. 1 Actual achievable frequency depends on design- and system-specific factors. Perform HSPICE/IBIS simulations based on your specific design and system setup to determine the maximum achievable frequency in your system. Table 1–24. Cyclone III Devices Active Configuration Mode Specifications Programming Mode DCLK Range Unit Active Parallel (AP) 20 – 40 MHz Active Serial (AS) 20 – 40 MHz Table 1–25. Cyclone III Devices JTAG Timing Parameters (1) Symbol Parameter Min Max Unit tJCP TCK clock period 40 — ns tJCH TCK clock high time 20 — ns tJCL TCK clock low time 20 — ns tJPSU_TDI JTAG port setup time for TDI 1 — ns tJPSU_TMS JTAG port setup time for TMS 3 — ns tJPH JTAG port hold time 10 — ns tJPCO JTAG port clock to output (2) —1 5n s tJPZX JTAG port high impedance to valid output (2) —1 5n s tJPXZ JTAG port valid output to high impedance (2) —1 5n s tJSSU Capture register setup time 5 — ns tJSH Capture register hold time 10 — ns tJSCO Update register clock to output — 25 ns tJSZX Update register high impedance to valid output — 25 ns tJSXZ Update register valid output to high impedance — 25 ns Notes to Table 1–25: (1) For more information abou t JTAG waveforms, refer to “JTAG Waveform” in “Glossary” on page 1–27. and 1.5-V LVCMOS, the JTAG port clock to output time is 16 ns.
1–18 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 High-Speed I/O Specifications Table 1–26 through Table 1–31 list the high-speed I/O timing for Cyclone III devices. For definitions of high-speed timing specifications, refer to “Glossary” on page 1–27. Table 1–26. Cyclone III Devices RSDS Transmitter Timing Specifications (1), (2) Symbol Modes C6 C7, I7 C8, A7 Unit Min Typ Max Min Typ Max Min Typ Max fHSCLK (input clock frequency) ×10 5 — 180 5 — 155.5 5 — 155.5 MHz ×8 5 — 180 5 — 155.5 5 — 155.5 MHz ×7 5 — 180 5 — 155.5 5 — 155.5 MHz ×4 5 — 180 5 — 155.5 5 — 155.5 MHz ×2 5 — 180 5 — 155.5 5 — 155.5 MHz ×1 5 — 360 5 — 311 5 — 311 MHz Device operation in Mbps ×10 100 — 360 100 — 311 100 — 311 Mbps ×8 80 — 360 80 — 311 80 — 311 Mbps ×7 70 — 360 70 — 311 70 — 311 Mbps ×4 40 — 360 40 — 311 40 — 311 Mbps ×2 20 — 360 20 — 311 20 — 311 Mbps ×1 10 — 360 10 — 311 10 — 311 Mbps t DUTY — 45 — 55 45 — 55 45 — 55 % Output jitter (peak to peak) — — — 500 — — 500 — — 550 ps t RISE 20 – 80%, CLOAD = 5p F — 500 — — 500 — — 500 — ps tFALL 20 – 80%, CLOAD = 5p F — 500 — — 500 — — 500 — ps Notes to Table 1–26: (1) Applicable for true RSDS and emulated RSDS_E_3R transmitter. (2) True RSDS transmitter is only supported at output pin of Row I/O (Banks 1, 2, 5, and 6). Emulated RSDS transmitter is supported at the output pin of all I/O banks. (3) t LOCK is the time required for the PLL to lock from the end of device configuration. Table 1–27. Cyclone III Devices Emulated RSDS_E_1R Transmitter Timing Specifications (1) (Part 1 of 2) Symbol Modes C6 C7, I7 C8, A7 Unit Min Typ Max Min Typ Max Min Typ Max fHSCLK (input clock frequency) ×10 5 — 85 5 — 85 5 — 85 MHz ×8 5 — 85 5 — 85 5 — 85 MHz ×7 5 — 85 5 — 85 5 — 85 MHz ×4 5 — 85 5 — 85 5 — 85 MHz ×2 5 — 85 5 — 85 5 — 85 MHz ×1 5 — 170 5 — 170 5 — 170 MHz
Chapter 1: Cyclone III Device Datasheet 1–19 Switching Characteristics July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 Device operation in Mbps ×10 100 — 170 100 — 170 100 — 170 Mbps ×8 80 — 170 80 — 170 80 — 170 Mbps ×7 70 — 170 70 — 170 70 — 170 Mbps ×4 40 — 170 40 — 170 40 — 170 Mbps ×2 20 — 170 20 — 170 20 — 170 Mbps ×1 10 — 170 10 — 170 10 — 170 Mbps t DUTY — 45 — 55 45 — 55 45 — 55 % Output jitter (peak to peak) t RISE 20 – 80%, CLOAD = 5 pF tFALL 20 – 80%, CLOAD = 5 pF Notes to Table 1–27: (1) Emulated RSDS_E_1R transmitter is suppor ted at the output pin of all I/O banks. (2) t LOCK is the time required for the PLL to lock from the end of device configuration. Table 1–27. Cyclone III Devices Emulated RSDS_E_1R Transmitter Timing Specifications (1) (Part 2 of 2) Symbol Modes C6 C7, I7 C8, A7 Unit Min Typ Max Min Typ Max Min Typ Max Table 1–28. Cyclone III Devices Mini-LVDS Transmitter Timing Specifications (1), (2) (Part 1 of 2) Symbol Modes C6 C7, I7 C8, A7 Unit Min Typ Max Min Typ Max Min Typ Max fHSCLK (input clock frequency) ×10 5 — 200 5 — 155.5 5 — 155.5 MHz ×8 5 — 200 5 — 155.5 5 — 155.5 MHz ×7 5 — 200 5 — 155.5 5 — 155.5 MHz ×4 5 — 200 5 — 155.5 5 — 155.5 MHz ×2 5 — 200 5 — 155.5 5 — 155.5 MHz ×1 5 — 400 5 — 311 5 — 311 MHz Device operation in Mbps ×10 100 — 400 100 — 311 100 — 311 Mbps ×8 80 — 400 80 — 311 80 — 311 Mbps ×7 70 — 400 70 — 311 70 — 311 Mbps ×4 40 — 400 40 — 311 40 — 311 Mbps ×2 20 — 400 20 — 311 20 — 311 Mbps ×1 10 — 400 10 — 311 10 — 311 Mbps t DUTY — 45 — 55 45 — 55 45 — 55 %
1–20 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Output jitter (peak to peak) tRISE 20 – 80%, CLOAD = 5 pF tFALL 20 – 80%, CLOAD = 5 pF Notes to Table 1–28: (1) Applicable for true and em ulated mini-LVDS transmitter. (2) True mini-LVDS transmitter is only support ed at the output pin of Row I/O (Banks 1, 2, 5, and 6). Emulated mini-LVDS transmitter is supported at the output pin of all I/O banks. (3) t LOCK is the time required for the PLL to lock from the end of device configuration. Table 1–28. Cyclone III Devices Mini-LVDS Transmitter Timing Specifications (1), (2) (Part 2 of 2) Symbol Modes C6 C7, I7 C8, A7 Unit Min Typ Max Min Typ Max Min Typ Max
Chapter 1: Cyclone III Device Datasheet 1–21 Switching Characteristics July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 Table 1–29. Cyclone III Devices True LVDS Transmitter Timing Specifications (1) Symbol Modes C6 C7, I7 C8, A7 Unit Min Max Min Max Min Max fHSCLK (input clock frequency) ×10 5 420 5 370 5 320 MHz ×8 5 420 5 370 5 320 MHz ×7 5 420 5 370 5 320 MHz ×4 5 420 5 370 5 320 MHz ×2 5 420 5 370 5 320 MHz ×1 5 420 5 402.5 5 402.5 MHz HSIODR ×10 100 840 100 740 100 640 Mbps ×8 80 840 80 740 80 640 Mbps ×7 70 840 70 740 70 640 Mbps ×4 40 840 40 740 40 640 Mbps ×2 20 840 20 740 20 640 Mbps ×1 10 420 10 402.5 10 402.5 Mbps t DUTY — 4 55 54 55 54 55 5% TCCS — — 200 — 200 — 200 ps Output jitter (peak to peak) — — 500 — 500 — 550 ps tLOCK (2) — —1—1—1m s Notes to Table 1–29: (1) True LVDS transmitter is only supported at th e output pin of Row I/O (Banks 1, 2, 5, and 6). (2) t LOCK is the time required for the PLL to lock from the end of device configuration. Table 1–30. Cyclone III Devices Emulated LVDS Transmitter Timing Specifications (1) (Part 1 of 2) Symbol Modes C6 C7, I7 C8, A7 Unit Min Max Min Max Min Max fHSCLK (input clock frequency) ×10 5 320 5 320 5 275 MHz ×8 5 320 5 320 5 275 MHz ×7 5 320 5 320 5 275 MHz ×4 5 320 5 320 5 275 MHz ×2 5 320 5 320 5 275 MHz ×1 5 402.5 5 402.5 5 402.5 MHz HSIODR ×10 100 640 100 640 100 550 Mbps ×8 80 640 80 640 80 550 Mbps ×7 70 640 70 640 70 550 Mbps ×4 40 640 40 640 40 550 Mbps ×2 20 640 20 640 20 550 Mbps ×1 10 402.5 10 402.5 10 402.5 Mbps t DUTY — 4 55 54 55 54 55 5% TCCS — — 200 — 200 — 200 ps
1–22 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 External Memory Interface Specifications Cyclone III devices support external memory interfaces up to 200 MHz. The external memory interfaces for Cyclone III devices are auto-calibrating and easy to implement. f For more information about external memory system performance specifications, board design guidelines, timing analysis, simulation, and debugging information, refer to Literature: External Memory Interfaces. Output jitter (peak to peak) — — 500 — 500 — 550 ps tLOCK (2) — —1—1—1m s Notes to Table 1–30: (1) Emulated LVDS transmitter is support ed at the output pin of all I/O banks. (2) t LOCK is the time required for the PLL to lock from the end of device configuration. Table 1–31. Cyclone III Devices LVDS Receiver Timing Specifications (1) Symbol Modes C6 C7, I7 C8, A7 Unit Min Max Min Max Min Max fHSCLK (input clock frequency) ×10 5 437.5 5 370 5 320 MHz ×8 5 437.5 5 370 5 320 MHz ×7 5 437.5 5 370 5 320 MHz ×4 5 437.5 5 370 5 320 MHz ×2 5 437.5 5 370 5 320 MHz ×1 5 437.5 5 402.5 5 402.5 MHz HSIODR ×10 100 875 100 740 100 640 Mbps ×8 80 875 80 740 80 640 Mbps ×7 70 875 70 740 70 640 Mbps ×4 40 875 40 740 40 640 Mbps ×2 20 875 20 740 20 640 Mbps ×1 10 437.5 10 402.5 10 402.5 Mbps SW — — 400 — 400 — 400 ps Input jitter tolerance — — 500 — 500 — 550 ps t LOCK (2) — —1—1—1m s Notes to Table 1–31: (1) LVDS receiver is supported at all banks. (2) t LOCK is the time required for the PLL to lock from the end of device configuration. Table 1–30. Cyclone III Devices Emulated LVDS Transmitter Timing Specifications (1) (Part 2 of 2) Symbol Modes C6 C7, I7 C8, A7 Unit Min Max Min Max Min Max
Chapter 1: Cyclone III Device Datasheet 1–23 Switching Characteristics July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 Table 1–32 lists the FPGA sampling window specifications for Cyclone III devices. Table 1–33 lists the transmitter channel-to-channel skew specifications for Cyclone III devices. Table 1–32. Cyclone III Devices FPGA Sampling Window (SW) Requirement – Read Side (1) Memory Standard Column I/Os Row I/Os Wraparound Mode Setup Hold Setup Hold Setup Hold DDR2 SDRAM 580 550 690 640 850 800 DDR SDRAM 585 535 700 650 870 820 QDRII SRAM 785 735 805 755 905 855 DDR2 SDRAM 705 650 770 715 985 930 DDR SDRAM 675 620 795 740 970 915 QDRII SRAM 900 845 910 855 1085 1030 DDR2 SDRAM 785 720 930 870 1115 1055 DDR SDRAM 800 740 915 855 1185 1125 QDRII SRAM 1050 990 1065 1005 1210 1150 DDR2 SDRAM 765 710 855 800 1040 985 DDR SDRAM 745 690 880 825 1000 945 QDRII SRAM 945 890 955 900 1130 1075 DDR2 SDRAM 805 745 1020 960 1145 1085 DDR SDRAM 880 820 955 935 1220 1160 QDRII SRAM 1090 1030 1105 1045 1250 1190 Note to Table 1–32: (1) Column I/Os refer to top and bottom I/Os. Row I/Os refer to righ t and left I/Os. Wraparound mode refers to the combination of column and row I/Os. Table 1–33. Cyclone III Devices Transmitter Channel-to-Channel Skew (TCCS) – Write Side (1) (Part 1 of 2) Memory Standard I/O Standard Column I/Os (ps) Row I/Os (ps) Wraparound Mode (ps) Lead Lag Lead Lag Lead Lag DDR2 SDRAM SSTL-18 Class I 790 380 790 380 890 480 SSTL-18 Class II 870 490 870 490 970 590 DDR SDRAM SSTL-2 Class I 750 320 750 320 850 420 SSTL-2 Class II 860 350 860 350 960 450 QDRII SRAM
1.8 V HSTL Class I 780 410 780 410 880 510
1.8 V HSTL Class II 830 510 830 510 930 610
1–24 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Table 1–34 lists the memory output clock jitter specifications for Cyclone III devices. DDR2 SDRAM SSTL-18 Class I 915 410 915 410 1015 510 SSTL-18 Class II 1025 545 1025 545 1125 645 DDR SDRAM SSTL-2 Class I 880 340 880 340 980 440 SSTL-2 Class II 1010 380 1010 380 1110 480 QDRII SRAM
1.8 V HSTL Class I 910 450 910 450 1010 550
1.8 V HSTL Class II 1010 570 1010 570 1110 670
SSTL-18 Class I 1040 440 1040 440 1140 540 SSTL-18 Class II 1180 600 1180 600 1280 700 DDR SDRAM SSTL-2 Class I 1010 360 1010 360 1110 460 SSTL-2 Class II 1160 410 1160 410 1260 510 QDRII SRAM
1.8 V HSTL Class I 1040 490 1040 490 1140 590
1.8 V HSTL Class II 1190 630 1190 630 1290 730
SSTL-18 Class I 961 431 961 431 1061 531 SSTL-18 Class II 1076 572 1076 572 1176 672 DDR SDRAM SSTL-2 Class I 924 357 924 357 1024 457 SSTL-2 Class II 1061 399 1061 399 1161 499 QDRII SRAM
1.8 V HSTL Class I 956 473 956 473 1056 573
1.8 V HSTL Class II 1061 599 1061 599 1161 699
(2) SSTL-18 Class I 1092 462 1092 462 1192 562 SSTL-18 Class II 1239 630 1239 630 1339 730 DDR SDRAM SSTL-2 Class I 1061 378 1061 378 1161 478 SSTL-2 Class II 1218 431 1218 431 1318 531 QDRII SRAM
1.8 V HSTL Class I 1092 515 1092 515 1192 615
1.8 V HSTL Class II 1250 662 1250 662 1350 762
Notes to Table 1–33: (1) Column I/O banks refer to top and bottom I/Os. Row I/O banks refer to right and left I/Os. Wraparound mode refers to the combination of column and row I/Os. (2) For DDR2 SDRAM write timing performan ce on Columns I/O for C8 and A7 devices, 97.5 degree phase offset is required. Table 1–33. Cyclone III Devices Transmitter Channel-to-Channel Skew (TCCS) – Write Side (1) (Part 2 of 2) Memory Standard I/O Standard Column I/Os (ps) Row I/Os (ps) Wraparound Mode (ps) Lead Lag Lead Lag Lead Lag Table 1–34. Cyclone III Devices Memory Output Clock Jitter Specifications (1), (2) (Part 1 of 2) Parameter Symbol Min Max Unit Clock period jitter t JIT(per) -125 125 ps Cycle-to-cycle period jitter t JIT(cc) -200 200 ps
Chapter 1: Cyclone III Device Datasheet 1–25 Switching Characteristics July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 Duty Cycle Distortion Specifications Table 1–35 lists the worst case duty cycle distortion for Cyclone III devices. OCT Calibration Timing Specification Table 1–36 lists the duration of calibration for series OCT with calibration at device power-up for Cyclone III devices. IOE Programmable Delay Table 1–37 and Table 1–38 list IOE programmable delay for Cyclone III devices. Duty cycle jitter t JIT(duty) -150 150 ps Notes to Table 1–34: (1) The memory output clock jitter measurem ents are for 200 consecutive clock cycles, as specified in the JEDEC DDR2 standard. (2) The clock jitter specification ap plies to memory output clock pins generated using DDIO circuits clocked by a PLL output routed on a global clock network. Table 1–34. Cyclone III Devices Memory Output Clock Jitter Specifications (1), (2) (Part 2 of 2) Parameter Symbol Min Max Unit Table 1–35. Duty Cycle Distortion on Cyclone III Devices I/O Pins (1), (2) Symbol C6 C7, I7 C8, A7 Unit Min Max Min Max Min Max O u t p u t D u t y C y c l e 4 55 54 55 54 55 5 % Notes to Table 1–35: (1) Duty cycle distortion specification applies to clock outputs from PLLs, global clock tree, and IOE driving dedicated and general purpose I/O pins. (2) Cyclone III devices meet sp ecified duty cycle distortion at maximum output toggle rate for each combination of I/O standard and current strength. Table 1–36. Cyclone III Devices Timing Specification for Series OCT with Calibration at Device Power-Up (1) Symbol Description Maximum Unit tOCTCAL Duration of series OCT with calibration at device power-up 20 µs Notes to Table 1–36: (1) OCT calibration takes place a fter device configuration, before entering user mode. Table 1–37. Cyclone III Devices IOE Programmable Delay on Column Pins (1), (2) (Part 1 of 2) Parameter Paths Affected Number of Settings Min Offset Max Offset UnitFast Corner Slow Corner A7, I7 C6 C6 C7 C8 I7 A7 Input delay from pin to internal cells Pad to I/O dataout to core Input delay from pin to input register Pad to I/O
1–26 Chapter 1: Cyclone III Device Datasheet I/O Timing Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 I/O Timing You can use the following methods to determine the I/O timing: ■ the Excel-based I/O Timing. ■ the Quartus II timing analyzer. The Excel-based I/O Timing provides pin timing performance for each device density and speed grade. The data is typically used prior to designing the FPGA to get a timing budget estimation as part of the link timing analysis. The Quartus II timing analyzer provides a more accurate and precise I/O timing data based on the specifics of the design after place-and-route is complete. Delay from output register to output pin I/O output register to pad Input delay from dual-purpose clock pin to fan-out destinations Pad to global clock network Notes to Table 1–37: (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of the Quartus II software. (2) The minimum and maximum offset timing numbers are in refe rence to setting ‘0’ as available in the Quartus II software. Table 1–37. Cyclone III Devices IOE Programmable Delay on Column Pins (1), (2) (Part 2 of 2) Parameter Paths Affected Number of Settings Min Offset Max Offset UnitFast Corner Slow Corner A7, I7 C6 C6 C7 C8 I7 A7 Table 1–38. Cyclone III Devices IOE Programmable Delay on Row Pins (1), (2) Parameter Paths Affected Number of Settings Min Offset Max Offset UnitFast Corner Slow Corner A7, I7 C6 C6 C7 C8 I7 A7 Input delay from pin to internal cells Pad to I/O dataout to core Input delay from pin to input register Pad to I/O Delay from output register to output pin I/O output register to pad Input delay from dual-purpose clock pin to fan-out destinations Pad to global Notes to Table 1–38: (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of Quartus II software. (2) The minimum and maximum offset timing numbers are in refe rence to setting ‘0’ as available in the Quartus II software
Chapter 1: Cyclone III Device Datasheet 1–27 Glossary July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 f The Excel-based I/O Timing spreadsheet is downloadable from Cyclone III Devices Literature website. Glossary Table 1–39 lists the glossary for this chapter. Table 1–39. Glossary (Part 1 of 5) Letter Term Definitions A —— B —— C —— D —— E —— F fHSCLK HIGH-SPEED I/O Block: High-speed receiver/transmitter input and output clock frequency. G GCLK Input pin directly to Global Clock network. GCLK PLL Input pin to Global Clock network through PLL. H HSIODR HIGH-SPEED I/O Block: Maximum/minimum LVDS data transfer rate (HSIODR = 1/TUI). I Input Waveforms for the SSTL Differential I/O Standard J JTAG Waveform K —— L —— M —— VIL VREF VIH VSWING TDO TCK tJPZX tJPCO tJSCO tJSXZ tJPH tJSH tJPXZ tJCP tJPSU_TMS t JCL tJCH TDI TMS Signal to be Captured Signal to be Driven tJPSU_TDI tJSZX tJSSU
1–28 Chapter 1: Cyclone III Device Datasheet Glossary Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 N —— O —— P PLL Block The following block diagram highlights the PLL Specification parameters. Q —— R RL Receiver differential input discrete resistor (external to Cyclone III devices). Receiver Input Waveform Receiver Input Waveform for LVDS and LVPECL Differential Standards. RSKM (Receiver input skew margin) HIGH-SPEED I/O Block: The total margin left after accounting for the sampling window and TCCS. RSKM = (TUI – SW – TCCS) / 2. Table 1–39. Glossary (Part 2 of 5) Letter Term Definitions Core Clock Phase tap Reconfigurable in User Mode Key CLK N M PFD VCOCP LF CLKOUT Pins GCLK fINPFDfIN fVCO fOUT fOUT _EXT Switchover Counters C0..C4 Single-Ended Waveform Differential Waveform (Mathematical Function of Positive & Negative Channel) Positive Channel (p) = VIH Negative Channel (n) = VIL Ground VID VID 0 V VCM p - n VID
Chapter 1: Cyclone III Device Datasheet 1–29 Glossary July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 S Single-ended Voltage referenced I/O Standard The JEDEC standard for SSTl and HSTL I/O standards defines both the AC and DC input signal values. The AC values indicate the voltage levels at which the receiver must meet its timing specifications. The DC values indicate the voltage levels at which the final logic state of the receiver is unambiguously defined. After the receiver input crosses the AC value, the receiver changes to the new logic state. The new logic state is then maintained as long as the input stays beyond the DC threshold. This approach is intended to provide predictable receiver timing in the presence of input waveform ringing. SW (Sampling Window) HIGH-SPEED I/O Block: The period of time during which the data must be valid to capture it correctly. The setup and hold times determine the ideal strobe position in the sampling window. T tC High-speed receiver/transmitter input and output clock period. TCCS (Channel- to-channel-skew) HIGH-SPEED I/O Block: The timing difference between the fastest and slowest output edges, including tCO variation and clock skew. The clock is included in the TCCS measurement. tcin Delay from clock pad to I/O input register. tCO Delay from clock pad to I/O output. tcout Delay from clock pad to I/O output register. tDUTY HIGH-SPEED I/O Block: Duty cycle on high-speed transmitter output clock. tFALL Signal High-to-low transition time (80–20%). tH Input register hold time. Timing Unit Interval (TUI) HIGH-SPEED I/O block: The timing budget allowed for skew, propagation delays, and data sampling window. (TUI = 1/(Receiver Input Clock Frequency Multiplication Factor) = tC/w). tINJITTER Period jitter on PLL clock input. tOUTJITTER_DEDCLK Period jitter on dedicated clock output driven by a PLL. tOUTJITTER_IO Period jitter on general purpose I/O driven by a PLL. tpllcin Delay from PLL inclk pad to I/O input register. tpllcout Delay from PLL inclk pad to I/O output register. Table 1–39. Glossary (Part 3 of 5) Letter Term Definitions VIH(AC) VIH(DC) VREF VIL(DC) VIL(AC) VOH VOL VCCIO VSS
1–30 Chapter 1: Cyclone III Device Datasheet Glossary Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Transmitter Output Waveform Transmitter Output Waveforms for the LVDS, mini-LVDS, PPDS and RSDS Differential I/O Standards tRISE Signal Low-to-high transition time (20–80%). tSU Input register setup time. U —— Table 1–39. Glossary (Part 4 of 5) Letter Term Definitions Single-Ended Waveform Differential Waveform (Mathematical Function of Positive & Negative Channel) Positive Channel (p) = VOH Negative Channel (n) = VOL Ground VOD VOD VOD 0 V Vos p - n
Chapter 1: Cyclone III Device Datasheet 1–31 Glossary July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 V VCM(DC) DC Common Mode Input Voltage. VDIF(AC) AC differential Input Voltage: The minimum AC input differential voltage required for switching. VDIF(DC) DC differential Input Voltage: The minimum DC input differential voltage required for switching. VICM Input Common Mode Voltage: The common mode of the differential signal at the receiver. VID Input differential Voltage Swing: The difference in voltage between the positive and complementary conductors of a differential transmission at the receiver. VIH Voltage Input High: The minimum positive voltage applied to the input which is accepted by the device as a logic high. VIH(AC) High-level AC input voltage. VIH(DC) High-level DC input voltage. VIL Voltage Input Low: The maximum positive voltage applied to the input which is accepted by the device as a logic low. VIL (AC) Low-level AC input voltage. VIL (DC) Low-level DC input voltage. VIN DC input voltage. VOCM Output Common Mode Voltage: The common mode of the differential signal at the transmitter. VOD Output differential Voltage Swing: The difference in voltage between the positive and complementary conductors of a differential transmission at the transmitter. VOD = VOH – VOL. VOH Voltage Output High: The maximum positive voltage from an output which the device considers is accepted as the minimum positive high level. VOL Voltage Output Low: The maximum positive voltage from an output which the device considers is accepted as the maximum positive low level. VOS Output offset voltage: VOS = (VOH + VOL) / 2. VOX (AC) AC differential Output cross point voltage: The voltage at which the differential output signals must cross. VREF Reference voltage for SSTL, HSTL I/O Standards. VREF (AC) AC input reference voltage for SSTL, HSTL I/O Standards. VREF(AC) = VREF(DC) + noise. The peak-to-peak AC noise on VREF should not exceed 2% of VREF(DC). VREF (DC) DC input reference voltage for SSTL, HSTL I/O Standards. VSWING (AC) AC differential Input Voltage: AC Input differential voltage required for switching. For the SSTL Differential I/O Standard, refer to Input Waveforms. VSWING (DC) DC differential Input Voltage: DC Input differential voltage required for switching. For the SSTL Differential I/O Standard, refer to Input Waveforms. VTT Termination voltage for SSTL, HSTL I/O Standards. VX (AC) AC differential Input cross point Voltage: The voltage at which the differential input signals must cross. W —— X —— Y —— Z —— Table 1–39. Glossary (Part 5 of 5) Letter Term Definitions
1–32 Chapter 1: Cyclone III Device Datasheet Document Revision History Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 Document Revision History Table 1–40 lists the revision history for this document. Table 1–40. Document Revision History (Part 1 of 3) Date Version Changes July 2012 3.5 Updated minimum f HSCLK value to 5 MHz. December 2011 3.4 ■ Updated “Supply Current” on page 1–5 and “Periphery Performance” on page 1–17. ■ Updated Table 1–3, Table 1–4, Table 1–13, Table 1–16, Table 1–17, Table 1–20, and Table 1–25. January 2010 3.3 ■ Removed Table 1-32 and Table 1-33. ■ Added Literature: External Memory Interfaces reference. December 2009 3.2 Minor changes to the text. July 2009 3.1 Minor edit to the hyperlinks. June 2009 3.0 ■ Changed chapter title from DC and Switching Characteristics to “Cyclone III Device Data Sheet” on page 1–1. ■ Updated (Note 1) to Table 1–23 on page 1–17. ■ Updated “External Memory Interface Specifications” on page 1–23. ■ Replaced Table 1–32 on page 1–23. ■ Replaced Table 1–33 on page 1–23. ■ Added Table 1–36 on page 1–26. ■ Updated “I/O Timing” on page 1–28. ■ Removed “Typical Design Performance” section. ■ Removed “I/O Timing” subsections. October 2008 2.2 ■ Updated chapter to new template. ■ Updated Table 1–1, Table 1–3, and Table 1–18. ■ Added (Note 7) to Table 1–3. ■ Added the “OCT Calibration Timing Specification” section. ■ Updated “Glossary” section. July 2008 2.1 ■ Updated Table 1–38. ■ Added BLVDS information (I/O standard) into Table 1–39, Table 1–40, Table 1–41, Table 1–42. ■ Updated Table 1–43, Table 1–46, Table 1–47, Table 1–48, Table 1–49, Table 1–50, Table 1–51, Table 1–52, Table 1–53, Table 1–54, Table 1–55, Table 1–56, Table 1–57, Table 1–58, Table 1–59, Table 1–60, Table 1–61, Table 1–62, Table 1–63, Table 1–68, Table 1–69, Table 1–74, Table 1–75, Table 1–80, Table 1–81, Table 1–86, Table 1–87, Table 1–92, Table 1–93, Table 1–94, Table 1–95, Table 1–96, Table 1–97, Table 1–98, and Table 1–99.
Chapter 1: Cyclone III Device Datasheet 1–33 Document Revision History July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 May 2008 2.0 ■ Updated “Operating Conditions” section and included information on automotive device. ■ Updated Table 1–3, Table 1–6, and Table 1–7, and added automotive information. ■ Under “Pin Capacitance” section, updated Table 1–9 and Table 1–10. ■ Added new “Schmitt Trigger Input” section with Table 1–12. ■ Under “I/O Standard Specifications” section, updated Table 1–13, 1–12 and 1–12. ■ Under “Switching Characteristics” section, updated Table 1–19, 1–15, 1–16, 1–16, 1–17, ■ Updated Figure 1–5 and 1–29. ■ Deleted previous Table 1-35 “DDIO Outputs Half-Period Jitter”. ■ Under “I/O Timing” section, updated Table 1–38, 1–29, 1–32, 1–33, 1–26, and 1–26. ■ Under “Typical Design Performance” section updated Table 1–46 through 1–145. December 2007 1.5 ■ Under “Core Performance Specifications”, updated Tables 1-18 and 1-19. ■ Under “Preliminary, Correlated, and Final Timing”, updated Table 1-37. ■ Under “Typical Design Performance”, updated Tables 1-45, 1-46, 1-51, 1-52, 1-57, 1-58, Tables 1-63 through 1-68. 1-69, 1-70, 1-75, 1-76, 1-81, 1-82, Tables 1-87 through 1-92, Tables 1-99, 1-100, 1-107, and 1-108. October 2007 1.4 ■ Updated the CVREFTB value in Table 1-9. ■ Updated Table 1-21. ■ Under “High-Speed I/O Specification” section, updated Tables 1-25 through 1-30. ■ Updated Tables 1-31 through 1-38. ■ Added new Table 1-32. ■ Under “Maximum Input and Output Clock Toggle Rate” section, updated Tables 1-40 through 1-42. ■ Under “IOE Programmable Delay” section, updated Tables 1-43 through 1-44. ■ Under “User I/O Pin Timing Parameters” section, updated Tables 1-45 through 1-92. ■ Under “Dedicated Clock Pin Timing Parameters” section, updated Tables 1-93 through 1- 108. July 2007 1.3 ■ Updated Table 1-1 with VESDHBM and VESDCDM information. ■ Updated RCONF_PD information in Tables 1-10. ■ Added Note (3) to Table 1-12. ■ Updated tDLOCK information in Table 1-19. ■ Updated Table 1-43 and Table 1-44. ■ Added “Document Revision History” section. June 2007 1.2 Updated Cyclone III graphic in cover page. Table 1–40. Document Revision History (Part 2 of 3) Date Version Changes
1–34 Chapter 1: Cyclone III Device Datasheet Document Revision History Cyclone III Device Handbook July 2012 Altera Corporation Volume 2 May 2007 1.1 ■ Corrected current unit in Tables 1-1, 1-12, and 1-14. ■ Added Note (3) to Table 1-3. ■ Updated Table 1-4 with ICCINT0, ICCA0, ICCD_PLL0, and ICCIO0 information. ■ Updated Table 1-9 and added Note (2). ■ Updated Table 1-19. ■ Updated Table 1-22 and added Note (1). ■ Changed I/O standard from 1.5-V LVTTL/LVCMOS and 1.2-V LVTTL/LVCMOS to 1.5-V LVCMOS and 1.2-V LVCMOS in Tables 1-41, 1-42, 1-43, 1-44, and 1-45. ■ Updated Table 1-43 with changes to LVPEC and LVDS and added Note (5). ■ Updated Tables 1-46, 1-47, Tables 1-54 through 1-95, and Tables 1-98 through 1-111. ■ Removed speed grade –6 from Tables 1-90 through 1-95, and from Tables 1-110 through 1-111. ■ Added a waveform (Receiver Input Waveform) in glossary under letter “R” (Table 1-112). March 2007 1.0 Initial release. Table 1–40. Document Revision History (Part 3 of 3) Date Version Changes