CYC2_CII5V1_01 ALTERA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 168
Technical content
Altera Corporation Section I–1 Preliminary Section I. Cyclone II Device Family Data Sheet This section provides information for board layout designers to successfully layout their boards for Cyclone® II devices. It contains the required PCB layout guidelines, device pin tables, and package specifications. This section includes the following chapters: ■ Chapter 1. Introduction ■ Chapter 2. Cyclone II Architecture ■ Chapter 3. Configuration & Testing ■ Chapter 4. Hot Socketing & Power-On Reset ■ Chapter 5. DC Characteristics and Timing Specifications ■ Chapter 6. Reference & Ordering Information Revision History Refer to each chapter for its own specific revision history. For information on when each chapter was updated, refer to the Chapter Revision Dates section, which appears in the complete handbook.
Section I–2 Altera Corporation Preliminary Revision History Cyclone II Device Handbook, Volume 1
Altera Corporation 1–1 February 2008 1. Introduction Introduction Following the immensely successful first-generation Cyclone® device family, Altera® Cyclone II FPGAs extend the low-cost FPGA density range to 68,416 logic elements (LEs) and provide up to 622 usable I/O pins and up to 1.1 Mbits of embedded memory. Cyclone II FPGAs are manufactured on 300-mm wafers using TSMC's 90-nm low-k dielectric process to ensure rapid availability and low cost. By minimizing silicon area, Cyclone II devices can support complex digital systems on a single chip at a cost that rivals that of ASICs. Unlike other FPGA vendors who compromise power consumption and performance for low-cost, Altera’s latest generation of low-cost FPGAs—Cyclone II FPGAs, offer 60% higher performance and half the power consumption of competing 90-nm FPGAs. The low cost and optimized feature set of Cyclone II FPGAs make them ideal solutions for a wide array of automotive, consumer, communications, video processing, test and measurement, and other end-market solutions. Reference designs, system diagrams, and IP , found at www.altera.com, are available to help you rapidly develop complete end-market solutions using Cyclone II FPGAs. Low-Cost Embedded Processing Solutions Cyclone II devices support the Nios II embedded processor which allows you to implement custom-fit embedded processing solutions. Cyclone II devices can also expand the peripheral set, memory, I/O, or performance of embedded processors. Single or multiple Nios II embedded processors can be designed into a Cyclone II device to provide additional co-processing power or even replace existing embedded processors in your system. Using Cyclone II and Nios II together allow for low-cost, high-performance embedded processing solutions, which allow you to extend your product's life cycle and improve time to market over standard product solutions. Low-Cost DSP Solutions Use Cyclone II FPGAs alone or as DSP co-processors to improve price-to-performance ratios for digital signal processing (DSP) applications. You can implement high-performance yet low-cost DSP systems with the following Cyclone II features and design support: ■ Up to 150 18 × 18 multipliers ■ Up to 1.1 Mbit of on-chip embedded memory ■ High-speed interfaces to external memory CII51001-3.2
1–2 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008
Features
■ DSP intellectual property (IP) cores ■ DSP Builder interface to The Mathworks Simulink and Matlab design environment ■ DSP Development Kit, Cyclone II Edition Cyclone II devices include a powerful FPGA feature set optimized for low-cost applications including a wide range of density, memory, embedded multiplier, and packaging options. Cyclone II devices support a wide range of common external memory interfaces and I/O protocols required in low-cost applications. Parameterizable IP cores from Altera and partners make using Cyclone II interfaces and protocols fast and easy. Features The Cyclone II device family offers the following features: ■ High-density architecture with 4,608 to 68,416 LEs
- M4K embedded memory blocks
- Up to 1.1 Mbits of RAM available without reducing available logic
- 4,096 memory bits per block (4,608 bits per block including 512 parity bits)
- Variable port configurations of ×1, ×2, ×4, ×8, ×9, ×16, ×18, ×32, and ×36
- True dual-port (one read and one write, two reads, or two writes) operation for ×1, ×2, ×4, ×8, ×9, ×16, and ×18 modes
- Byte enables for data input masking during writes
- Up to 260-MHz operation ■ Embedded multipliers
- Up to 150 18- × 18-bit multipliers are each configurable as two independent 9- × 9-bit multipliers with up to 250-MHz performance
- Optional input and output registers ■ Advanced I/O support
- High-speed differential I/O standard support, including LVDS, RSDS, mini-LVDS, LVPECL, differential HSTL, and differential SSTL
- Single-ended I/O standard support, including 2.5-V and 1.8-V , SSTL class I and II, 1.8-V and 1.5-V HSTL class I and II, 3.3-V PCI and 1.8-V LVTTL
- Peripheral Component Interconnect Special Interest Group (PCI SIG) PCI Local Bus Specification, Revision 3.0 compliance for 3.3-V operation at 33 or 66 MHz for 32- or 64-bit interfaces
- PCI Express with an external TI PHY and an Altera PCI Express ×1 Megacore® function
Altera Corporation 1–3 February 2008 Cyclone II Device Handbook, Volume 1 Introduction
- 133-MHz PCI-X 1.0 specification compatibility
- High-speed external memory support, including DDR, DDR2, and SDR SDRAM, and QDRII SRAM supported by drop in Altera IP MegaCore functions for ease of use
- Three dedicated registers per I/O element (IOE): one input register, one output register, and one output-enable register
- Programmable bus-hold feature
- Programmable output drive strength feature
- Programmable delays from the pin to the IOE or logic array
- I/O bank grouping for unique VCCIO and/or VREF bank settings
- MultiVolt™ I/O standard support for 1.5-, 1.8-, 2.5-, and 3.3-interfaces
- Hot-socketing operation support
- Tri-state with weak pull-up on I/O pins before and during configuration
- Programmable open-drain outputs
- Series on-chip termination support ■ Flexible clock management circuitry
- Hierarchical clock network for up to 402.5-MHz performance
- Up to four PLLs per device provide clock multiplication and division, phase shifting, programmable duty cycle, and external clock outputs, allowing system-level clock management and skew control
- Up to 16 global clock lines in the global clock network that drive throughout the entire device ■ Device configuration
- Fast serial configuration allows configuration times less than 100 ms
- Decompression feature allows for smaller programming file storage and faster configuration times
- Supports multiple configuration modes: active serial, passive serial, and JTAG-based configuration
- Supports configuration through low-cost serial configuration devices
- Device configuration supports multiple voltages (either 3.3, 2.5, or 1.8 V) ■ Intellectual property
- Altera megafunction and Altera MegaCore function support, and Altera Megafunctions Partners Program (AMPPSM) megafunction support, for a wide range of embedded processors, on-chip and off-chip interfaces, peripheral functions, DSP functions, and communications functions and
1–4 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 protocols. Visit the Altera IPMegaStore at www.altera.com to download IP MegaCore functions.
- Nios II Embedded Processor support The Cyclone II family offers devices with the Fast-On feature, which offers a faster power-on-reset (POR) time. Devices that support the Fast-On feature are designated with an “A” in the device ordering code. For example, EP2C5A, EP2C8A, EP2C15A, and EP2C20A. The EP2C5A is only available in the automotive speed grade. The EP2C8A and EP2C20A are only available in the industrial speed grade. The EP2C15A is only available with the Fast-On feature and is available in both commercial and industrial grades. The Cyclone II “A” devices are identical in feature set and functionality to the non-A devices except for support of the faster POR time. f Cyclone II A devices are offered in automotive speed grade. For more information, refer to the Cyclone II section in the Automotive-Grade Device Handbook. f For more information on POR time specifications for Cyclone II A and non-A devices, refer to the Hot Socketing & Power-On Reset chapter in the Cyclone II Device Handbook. Table 1–1 lists the Cyclone II device family features. Table 1–2 lists the Cyclone II device package offerings and maximum user I/O pins. Table 1–1. Cyclone II FPGA Family Features (Part 1 of 2) Feature EP2C5 (2) EP2C8 (2) EP2C15 (1) EP2C20 (2) EP2C35 EP2C50 EP2C70 LEs 4,608 8,256 14,448 18,752 33,216 50,528 68,416 M4K RAM blocks (4 Kbits plus 512 parity bits 26 36 52 52 105 129 250 Total RAM bits 119,808 165,888 239,616 239,616 483,840 594,432 1,152,00 Embedded multipliers (3) 13 18 26 26 35 86 150 PLLs 2 2 4 4 4 4 4
Altera Corporation 1–5 February 2008 Cyclone II Device Handbook, Volume 1 Introduction Maximum user I/O pins 158 182 315 315 475 450 622 Notes to Tab le 1–1: (1) The EP2C15A is only available with the Fast On feature, which offers a faster POR time. This device is available in both commercial and industrial grade. (2) The EP2C5, EP2C8, and EP2C20 optionally support the Fa st On feature, which is designated with an “A” in the device ordering code. The EP2C5A is only available in the automotive speed grade. The EP2C8A and EP2C20A devices are only available in industrial grade. (3) This is the total number of 18 × 18 multipliers. For the total number of 9 × 9 multipliers per device, multiply the total number of 18 × 18 multipliers by 2. Table 1–1. Cyclone II FPGA Family Features (Part 2 of 2) Feature EP2C5 (2) EP2C8 (2) EP2C15 (1) EP2C20 (2) EP2C35 EP2C50 EP2C70
1–6 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Cyclone II devices support vertical migration within the same package (for example, you can migrate between the EP2C35, EPC50, and EP2C70 devices in the 672-pin FineLine BGA package). The exception to vertical migration support within the Cyclone II family is noted in Table 1–3. Table 1–2. Cyclone II Package Options & Maximum User I/O Pins Notes (1) (2) Device 144-Pin TQFP (3) 208-Pin PQFP (4) 240-Pin PQFP 256-Pin FineLine BGA 484-Pin FineLine BGA 484-Pin Ultra FineLine BGA 672-Pin FineLine BGA 896-Pin FineLine BGA EP2C8 (6) 85 138 — 182 — — — — EP2C20 (6) — — 142 152 315 — — — EP2C35 (6) — — — — 322 322 475 — EP2C50 (6) — — — — 294 294 450 — Notes to Tab le 1–2: (1) Cyclone II devices support vertical migration within the same package (for example, you can migrate between the EP2C20 device in the 484-pin FineLine BGA package and the EP2C35 and EP2C50 devices in the same package). (2) The Quartus ® II software I/O pin counts include four additional pins, TDI, TDO, TMS, and TCK, which are not available as general purpose I/O pins. (3) TQFP: thin quad flat pack. (4) PQFP: plastic quad flat pack. (5) Vertical migration is supported between the EP2C5F256 and the EP2C8F256 devices. However, not all of the DQ and DQS groups are supported. Vertical migration between the EP2C5 and the EP2C15 in the F256 package is not supported. (6) The I/O pin counts for the EP2C5, EP2C8, and EP2C15A devices include 8 dedicated clock pins that can be used for data inputs. The I/O counts for the EP2C20, EP2C35, EP2C50, and EP2C70 devices include 16 dedicated clock pins that can be used for data inputs. (7) EP2C8A, EP2C15A, and EP2C20A have a Fast On feature that has a faster POR time. The EP2C15A is only available with the Fast On option. (8) The EP2C5 optionally support the Fast On feature, which is designated with an “A” in the device ordering code. The EP2C5A is only available in the automotive speed grade. Refer to the Cyclone II section in the Automotive-Grade Device Handbook.
Altera Corporation 1–7 February 2008 Cyclone II Device Handbook, Volume 1 Introduction Vertical migration means that you can migrate to devices whose dedicated pins, configuration pins, and power pins are the same for a given package across device densities.
1 When moving from one density to a larger density, I/O pins are
often lost because of the greater number of power and ground pins required to support the additional logic within the larger device. For I/O pin migration across densities, you must cross reference the available I/O pins using the device pin-outs for all planned densities of a given package type to identify which I/O pins are migratable. To ensure that your board layout supports migratable densities within one package offering, enable the applicable vertical migration path within the Quartus II software (go to Assignments menu, then Device, then click the Migration Devices button). After compilation, check the information messages for a full list of I/O, DQ, LVDS, and other pins that are not available because of the selected migration path. Table 1–3 lists the Cyclone II device package offerings and shows the total number of non-migratable I/O pins when migrating from one density device to a larger density device. Table 1–3. Total Number of Non-Migratable I/O Pins for Cyclone II Vertical Migration Paths Vertical Migration Path 144-Pin TQFP 208-Pin PQFP 256-Pin FineLine BGA (1) 484-Pin FineLine BGA (2) 484-Pin Ultra FineLine BGA 672-Pin FineLine BGA (3) EP2C5 to EP2C8 44 1 (4) ——— EP2C8 to EP2C15 EP2C15 to EP2C20 —— 0 0 —— EP2C20 to EP2C35 ——1 6—— EP2C35 to EP2C50 — — — 28 28 (5) 28 EP2C50 to EP2C70 ————2 82 8 Notes to Tab le 1–3: (1) Vertical migration between the EP2C5F256 to the EP2C15AF256 and the EP2C5F256 to the EP2C20F256 devices is not supported. (2) When migrating from the EP2C20F484 device to the EP2C50 F484 device, a total of 39 I/O pins are non-migratable. (3) When migrating from the EP2C35F672 device to the EP2C70 F672 device, a total of 56 I/O pins are non-migratable. (4) In addition to the one non-migratable I/O pin, there are 34 DQ pins that are non-migratable. (5) The pinouts of 484 FBGA and 484 UBGA are the same.
1–8 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Cyclone II devices are available in up to three speed grades: –6, –7, and –8, with –6 being the fastest. Table 1–4 shows the Cyclone II device speed-grade offerings. Table 1–4. Cyclone II Device Speed Grades Device 144-Pin TQFP 208-Pin PQFP 240-Pin PQFP 256-Pin FineLine BGA 484-Pin FineLine BGA 484-Pin Ultra FineLine BGA 672-Pin FineLine BGA 896-Pin FineLine BGA Notes to Tab le 1–4: (1) The EP2C5 optionally support the Fast On feature, which is designated with an “A” in the device ordering code. The EP2C5A is only available in the automotive speed grade. Refer to the Cyclone II section in the Automotive-Grade Device Handbook for detailed information. (2) EP2C8A and EP2C20A are only available in industrial grade.
Altera Corporation 1–9 February 2008 Cyclone II Device Handbook, Volume 1 Introduction Referenced Documents This chapter references the following documents: ■ Hot Socketing & Power-On Reset chapter in Cyclone II Device Handbook ■ Automotive-Grade Device Handbook Document
Revision History
Table 1–5 shows the revision history for this document. Table 1–5. Document Revision History Date & Document Version Changes Made Summary of Changes February 2008 v3.2
- Added “Referenced Documents”.
- Updated “Features” section and Table 1–1, Table 1–2, and Table 1–4 with information about EP2C5A. February 2007 v3.1
- Added document revision history.
- Added new Note (2) to Table 1–2. Note to explain difference between I/O pin count information provided in Table 1–2 and in the Quartus II software documentation. November 2005 v2.1
- Updated Introduction and Features.
- Updated Table 1–3. July 2005 v2.0 ● Updated technical content throughout.
- Updated Table 1–2.
- Added Tables 1–3 and 1–4. November 2004 v1.1
- Updated Table 1–2.
- Updated bullet list in the “Features” section. June 2004 v1.0 Added document to the Cyclone II Device Handbook. —
1–10 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Document Revision History
Altera Corporation 2–1 February 2007 2. Cyclone II Architecture Functional
Description
Cyclone® II devices contain a two-dimensional row- and column-based architecture to implement custom logic. Column and row interconnects of varying speeds provide signal interconnects between logic array blocks (LABs), embedded memory blocks, and embedded multipliers. The logic array consists of LABs, with 16 logic elements (LEs) in each LAB. An LE is a small unit of logic providing efficient implementation of user logic functions. LABs are grouped into rows and columns across the device. Cyclone II devices range in density from 4,608 to 68,416 LEs. Cyclone II devices provide a global clock network and up to four phase-locked loops (PLLs). The global clock network consists of up to 16 global clock lines that drive throughout the entire device. The global clock network can provide clocks for all resources within the device, such as input/output elements (IOEs), LEs, embedded multipliers, and embedded memory blocks. The global clock lines can also be used for other high fan-out signals. Cyclone II PLLs provide general-purpose clocking with clock synthesis and phase shifting as well as external outputs for high-speed differential I/O support. M4K memory blocks are true dual-port memory blocks with 4K bits of memory plus parity (4,608 bits). These blocks provide dedicated true dual-port, simple dual-port, or single-port memory up to 36-bits wide at up to 260 MHz. These blocks are arranged in columns across the device in between certain LABs. Cyclone II devices offer between 119 to 1,152 Kbits of embedded memory. Each embedded multiplier block can implement up to either two 9 × 9-bit multipliers, or one 18 × 18-bit multiplier with up to 250-MHz performance. Embedded multipliers are arranged in columns across the device. Each Cyclone II device I/O pin is fed by an IOE located at the ends of LAB rows and columns around the periphery of the device. I/O pins support various single-ended and differential I/O standards, such as the 66- and 33-MHz, 64- and 32-bit PCI standard, PCI-X, and the LVDS I/O standard at a maximum data rate of 805 megabits per second (Mbps) for inputs and 640 Mbps for outputs. Each IOE contains a bidirectional I/O buffer and three registers for registering input, output, and output-enable signals. Dual-purpose DQS, DQ, and DM pins along with delay chains (used to CII51002-3.1
2–4 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Logic Elements Another special packing mode allows the register output to feed back into the LUT of the same LE so that the register is packed with its own fan-out LUT, providing another mechanism for improved fitting. The LE can also drive out registered and unregistered versions of the LUT output. In addition to the three general routing outputs, the LEs within an LAB have register chain outputs. Register chain outputs allow registers within the same LAB to cascade together. The register chain output allows an LAB to use LUTs for a single combinational function and the registers to be used for an unrelated shift register implementation. These resources speed up connections between LABs while saving local interconnect resources. See “MultiTrack Interconnect” on page 2–10 for more information on register chain connections. LE Operating Modes The Cyclone II LE operates in one of the following modes: ■ Normal mode ■ Arithmetic mode Each mode uses LE resources differently. In each mode, six available inputs to the LE—the four data inputs from the LAB local interconnect, the LAB carry-in from the previous carry-chain LAB, and the register chain connection—are directed to diff erent destinations to implement the desired logic function. LAB-wide signals provide clock, asynchronous clear, synchronous clear, synchronous load, and clock enable control for the register. These LAB-wide signals are available in all LE modes. The Quartus® II software, in conjunction with parameterized functions such as library of parameterized modules (LPM) functions, automatically chooses the appropriate mode for common functions such as counters, adders, subtractors, and arithmetic functions. If required, you can also create special-purpose functions that specify which LE operating mode to use for optimal performance. Normal Mode The normal mode is suitable for general logic applications and combinational functions. In normal mode, four data inputs from the LAB local interconnect are inputs to a four-input LUT (see Figure 2–3). The Quartus II Compiler automatically selects the carry-in or the data3 signal as one of the inputs to the LUT. LEs in normal mode support packed registers and register feedback.
Altera Corporation 2–5 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Figure 2–3. LE in Normal Mode Arithmetic Mode The arithmetic mode is ideal for implementing adders, counters, accumulators, and comparators. An LE in arithmetic mode implements a 2-bit full adder and basic carry chain (see Figure 2–4). LEs in arithmetic mode can drive out registered and unregistered versions of the LUT output. Register feedback and register packing are supported when LEs are used in arithmetic mode. data1 Four-Input LUT data2 data3 cin (from cout of previous LE) data4 clock (LAB Wide) ena (LAB Wide) aclr (LAB Wide) CLRN D Q ENA sclear (LAB Wide) sload (LAB Wide) Register chain connection Register chain output Row, Column, and Direct Link Routing Row, Column, and Direct Link Routing Local routing Register Feedback Packed Register Input
2–6 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Logic Elements Figure 2–4. LE in Arithmetic Mode The Quartus II Compiler automatically creates carry chain logic during design processing, or you can create it manually during design entry. Parameterized functions such as LPM functions automatically take advantage of carry chains for the appropriate functions. The Quartus II Compiler creates carry chains longer than 16 LEs by automatically linking LABs in the same column. For enhanced fitting, a long carry chain runs vertically, which allows fast horizontal connections to M4K memory blocks or embedded multipliers through direct link interconnects. For example, if a design has a long carry chain in a LAB column next to a column of M4K memory blocks, any LE output can feed an adjacent M4K memory block through the direct link interconnect. Whereas if the carry chains ran horizontally, any LAB not next to the column of M4K memory blocks would use other row or column interconnects to drive a M4K memory block. A carry chain continues as far as a full column. clock (LAB Wide) ena (LAB Wide) aclr (LAB Wide) CLRN D Q ENA Register chain connection sclear (LAB Wide) sload (LAB Wide) Register chain output Row, column, and direct link routing Row, column, and direct link routing Local routing Register Feedback Three-Input LUT Three-Input LUT cin (from cout of previous LE) data2 data1 cout
2–8 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Logic Array Blocks LAB Interconnects The LAB local interconnect can drive LEs within the same LAB. The LAB local interconnect is driven by column and row interconnects and LE outputs within the same LAB. Neighboring LABs, PLLs, M4K RAM blocks, and embedded multipliers from the left and right can also drive an LAB’s local interconnect through the direct link connection. The direct link connection feature minimizes the use of row and column interconnects, providing higher performance and flexibility. Each LE can drive 48 LEs through fast local and direct link interconnects. Figure 2–6 shows the direct link connection. Figure 2–6. Direct Link Connection LAB Control Signals Each LAB contains dedicated logic for driving control signals to its LEs. The control signals include: ■ Two clocks ■ Two clock enables ■ Two asynchronous clears ■ One synchronous clear ■ One synchronous load LAB Direct link interconnect to right Direct link interconnect from right LAB, M4K memory block, embedded multiplier, PLL, or IOE output Direct link interconnect from left LAB, M4K memory block, embedded multiplier, PLL, or IOE output Local Interconnect Direct link interconnect to left
Altera Corporation 2–9 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture This gives a maximum of seven control signals at a time. When using the LAB-wide synchronous load, the clkena of labclk1 is not available. Additionally, register packing and synchronous load cannot be used simultaneously. Each LAB can have up to four non-global control signals. Additional LAB control signals can be used as long as they are global signals. Synchronous clear and load signals are useful for implementing counters and other functions. The synchronous clear and synchronous load signals are LAB-wide signals that affect all registers in the LAB. Each LAB can use two clocks and two clock enable signals. Each LAB’s clock and clock enable signals are linked. For example, any LE in a particular LAB using the labclk1 signal also uses labclkena1. If the LAB uses both the rising and falling edges of a clock, it also uses both LAB-wide clock signals. De-asserting the clock enable signal turns off the LAB-wide clock. The LAB row clocks [5..0] and LAB local interconnect generate the LAB- wide control signals. The MultiTrack™ interconnect’s inherent low skew allows clock and control signal distribution in addition to data. Figure 2–7 shows the LAB control signal generation circuit. Figure 2–7. LAB-Wide Control Signals LAB-wide signals control the logic for the register’s clear signal. The LE directly supports an asynchronous clear function. Each LAB supports up to two asynchronous clear signals (labclr1 and labclr2). labclkena1 labclk2labclk1 labclkena2 labclr1 Dedicated LAB Row Clocks Local Interconnect Local Interconnect Local Interconnect Local Interconnect syncload synclr labclr2
2–10 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 MultiTrack Interconnect A LAB-wide asynchronous load signal to control the logic for the register’s preset signal is not available. The register preset is achieved by using a NOT gate push-back technique. Cyclone II devices can only support either a preset or asynchronous clear signal. In addition to the clear port, Cyclone II devices provide a chip-wide reset pin (DEV_CLRn) that resets all registers in the device. An option set before compilation in the Quartus II software controls this pin. This chip-wide reset overrides all other control signals. MultiTrack Interconnect In the Cyclone II architecture, connections between LEs, M4K memory blocks, embedded multipliers, and device I/O pins are provided by the MultiTrack interconnect structure with DirectDrive™ technology. The MultiTrack interconnect consists of continuous, performance-optimized routing lines of different speeds used for inter- and intra-design block connectivity. The Quartus II Compiler automatically places critical paths on faster interconnects to improve design performance. DirectDrive technology is a deterministic routing technology that ensures identical routing resource usage for any function regardless of placement within the device. The MultiTrack interconnect and DirectDrive technology simplify the integration stage of block-based designing by eliminating the re-optimization cycles that typically follow design changes and additions. The MultiTrack interconnect consists of row (direct link, R4, and R24) and column (register chain, C4, and C16) interconnects that span fixed distances. A routing structure with fixed-length resources for all devices allows predictable and repeatable performance when migrating through different device densities. Row Interconnects Dedicated row interconnects route signals to and from LABs, PLLs, M4K memory blocks, and embedded multipliers within the same row. These row resources include: ■ Direct link interconnects between LABs and adjacent blocks ■ R4 interconnects traversing four blocks to the right or left ■ R24 interconnects for high-speed access across the length of the device
Altera Corporation 2–11 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture The direct link interconnect allows an LAB, M4K memory block, or embedded multiplier block to drive into the local interconnect of its left and right neighbors. Only one side of a PLL block interfaces with direct link and row interconnects. The direct link interconnect provides fast communication between adjacent LABs and/or blocks without using row interconnect resources. The R4 interconnects span four LABs, three LABs and one M4K memory block, or three LABs and one embedded multiplier to the right or left of a source LAB. These resources are used for fast row connections in a four- LAB region. Every LAB has its own set of R4 interconnects to drive either left or right. Figure 2–8 shows R4 interconnect connections from an LAB. R4 interconnects can drive and be driven by LABs, M4K memory blocks, embedded multipliers, PLLs, and row IOEs. For LAB interfacing, a primary LAB or LAB neighbor (see Figure 2–8) can drive a given R4 interconnect. For R4 interconnects that drive to the right, the primary LAB and right neighbor can drive on to the interconnect. For R4 interconnects that drive to the left, the primary LAB and its left neighbor can drive on to the interconnect. R4 interconnects can drive other R4 interconnects to extend the range of LABs they can drive. Additionally, R4 interconnects can drive R24 interconnects, C4, and C16 interconnects for connections from one row to another. Figure 2–8. R4 Interconnect Connections Notes to Figure 2–8: (1) C4 interconnects can drive R4 interconnects. (2) This pattern is repeated for every LAB in the LAB row. Primary LAB (2) R4 Interconnect Driving Left Adjacent LAB can Drive onto Another LAB's R4 Interconnect C4 Column Interconnects (1) R4 Interconnect Driving Right LAB Neighbor LAB Neighbor
2–12 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 MultiTrack Interconnect R24 row interconnects span 24 LABs and provide the fastest resource for long row connections between non-adjacent LABs, M4K memory blocks, dedicated multipliers, and row IOEs. R24 row interconnects drive to other row or column interconnects at every fourth LAB. R24 row interconnects drive LAB local interconnects via R4 and C4 interconnects and do not drive directly to LAB local interconnects. R24 interconnects can drive R24, R4, C16, and C4 interconnects. Column Interconnects The column interconnect operates similar to the row interconnect. Each column of LABs is served by a dedicated column interconnect, which vertically routes signals to and from LABs, M4K memory blocks, embedded multipliers, and row and column IOEs. These column resources include: ■ Register chain interconnects within an LAB ■ C4 interconnects traversing a distance of four blocks in an up and down direction ■ C16 interconnects for high-speed vertical routing through the device Cyclone II devices include an enhanced interconnect structure within LABs for routing LE output to LE input connections faster using register chain connections. The register chain connection allows the register output of one LE to connect directly to the register input of the next LE in the LAB for fast shift registers. The Quartus II Compiler automatically takes advantage of these resources to improve utilization and performance. Figure 2–9 shows the register chain interconnects.
Altera Corporation 2–13 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Figure 2–9. Register Chain Interconnects The C4 interconnects span four LABs, M4K blocks, or embedded multipliers up or down from a source LAB. Every LAB has its own set of C4 interconnects to drive either up or down. Figure 2–10 shows the C4 interconnect connections from an LAB in a column. The C4 interconnects can drive and be driven by all types of architecture blocks, including PLLs, M4K memory blocks, embedded multiplier blocks, and column and row IOEs. For LAB interconnection, a primary LAB or its LAB neighbor (see Figure 2–10) can drive a given C4 interconnect. C4 interconnects can drive each other to extend their range as well as drive row interconnects for column-to-column connections. LE 1 LE 2 LE 3 LE 4 LE 5 LE 6 LE 7 LE 8 LE 9 LE 10 LE 11 LE 12 LE13 LE 14 LE 15 LE 16 Carry Chain Routing to Adjacent LE Local Interconnect Register Chain Routing to Adjacen t LE's Register Input Local Interconnect Routing Among LEs in the LAB
2–14 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 MultiTrack Interconnect Figure 2–10. C4 Interconnect Connections Note (1) Note to Figure 2–10: (1) Each C4 interconnect can drive either up or down four rows. C4 Interconnect Drives Local and R4 Interconnects Up to Four Rows Adjacent LAB can drive onto neighboring LAB's C4 interconnect C4 Interconnect Driving Up C4 Interconnect Driving Down LAB Row Interconnect Local Interconnect Primary LAB LAB Neighbor
Altera Corporation 2–15 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture C16 column interconnects span a length of 16 LABs and provide the fastest resource for long column connections between LABs, M4K memory blocks, embedded multipliers, and IOEs. C16 column interconnects drive to other row and column interconnects at every fourth LAB. C16 column interconnects drive LAB local interconnects via C4 and R4 interconnects and do not drive LAB local interconnects directly. C16 interconnects can drive R24, R4, C16, and C4 interconnects. Device Routing All embedded blocks communicate with the logic array similar to LAB-to-LAB interfaces. Each block (for example, M4K memory, embedded multiplier, or PLL) connects to row and column interconnects and has local interconnect regions driven by row and column interconnects. These blocks also have direct link interconnects for fast connections to and from a neighboring LAB. Table 2–1 shows the Cyclone II device’s routing scheme. Table 2–1. Cyclone II Device Routing Scheme (Part 1 of 2) Source Destination Register Chain Local Interconnect Direct Link Interconnect R4 Interconnect R24 Interconnect C4 Interconnect C16 Interconnect LE M4K RAM Block Embedded Multiplier PLL Column IOE Row IOE Register Chain v Local Interconnect vvvvvv Direct Link Interconnect v Interconnect v vvvv R24 Interconnect vvvv Interconnect v vvvv C16 Interconnect vvvv
2–16 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Global Clock Network & Phase-Locked Loops Global Clock Network & Phase-Locked Loops Cyclone II devices provide global clock networks and up to four PLLs for a complete clock management solution. Cyclone II clock network features include: ■ Up to 16 global clock networks ■ Up to four PLLs ■ Global clock network dynamic clock source selection ■ Global clock network dynamic enable and disable LE vvvv v M4K memory Block vvv v Embedded Multipliers vvv v PLL vv v Column IOE vv Row IOE vvvv Table 2–1. Cyclone II Device Routing Scheme (Part 2 of 2) Source Destination Register Chain Local Interconnect Direct Link Interconnect R4 Interconnect R24 Interconnect C4 Interconnect C16 Interconnect LE M4K RAM Block Embedded Multiplier PLL Column IOE Row IOE
Altera Corporation 2–17 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Each global clock network has a clock control block to select from a number of input clock sources (PLL clock outputs, CLK[] pins, DPCLK[] pins, and internal logic) to drive onto the global clock network. Table 2–2 lists how many PLLs, CLK[] pins, DPCLK[] pins, and global clock networks are available in each Cyclone II device. CLK[] pins are dedicated clock pins and DPCLK[] pins are dual-purpose clock pins. Figures 2–11 and 2–12 show the location of the Cyclone II PLLs, CLK[] inputs, DPCLK[] pins, and clock control blocks. Table 2–2. Cyclone II Device Clock Resources Device Number of PLLs Number of CLK Pins Number of DPCLK Pins Number of Global Clock Networks EP2C5 2 8 8 8 EP2C8 2 8 8 8 EP2C15 4 16 20 16 EP2C20 4 16 20 16 EP2C35 4 16 20 16 EP2C50 4 16 20 16 EP2C70 4 16 20 16
2–18 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Global Clock Network & Phase-Locked Loops Figure 2–11. EP2C5 & EP2C8 PLL, CLK[], DPCLK[] & Clock Control Block Locations Note to Figure 2–11: (1) There are four clock control blocks on each side. PLL 2 CLK[7..4] DPCLK7 DPCLK6 CLK[3..0] DPCLK0 DPCLK1 DPCLK10 DPCLK8 DPCLK2 GCLK[7..0] GCLK[7..0] DPCLK4 PLL 1 Clock Control Block (1) Clock Control Block (1)
Altera Corporation 2–19 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Figure 2–12. EP2C15 & Larger PLL, CLK[], DPCLK[] & Clock Control Block Locations Notes to Figure 2–12: (1) There are four clock control blocks on each side. (2) Only one of the corner CDPCLK pins in each corner can feed the clock control block at a time. The other CDPCLK pins can be used as general-purpose I/O pins. PLL 4 PLL 3 PLL 2 CLK[7..4] DPCLK7 CDPCLK5 CDPCLK4 DPCLK6 CLK[3..0] DPCLK0 CDPCLK0 CDPCLK1 DPCLK1 CDPCLK7 DPCLK[9..8]DPCLK[11..10] CLK[11..8] GCLK[15..0] GCLK[15..0] PLL 1 CDPCLK6 CDPCLK2 DPCLK[5..4]DPCLK[3..2] CLK[15..12] CDPCLK3 Clock Control Block (1) Clock Control Block (1) 16 16 (2) (2) (2) (2)
2–20 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Global Clock Network & Phase-Locked Loops Dedicated Clock Pins Larger Cyclone II devices (EP2C15 and larger devices) have 16 dedicated clock pins (CLK[15..0], four pins on each side of the device). Smaller Cyclone II devices (EP2C5 and EP2C8 devices) have eight dedicated clock pins (CLK[7..0], four pins on left and right sides of the device). These CLK pins drive the global clock network (GCLK), as shown in Figures 2–11 and 2–12. If the dedicated clock pins are not used to feed the global clock networks, they can be used as general-purpose input pins to feed the logic array using the MultiTrack interconnect. However, if they are used as general- purpose input pins, they do not have support for an I/O register and must use LE-based registers in place of an I/O register. Dual-Purpose Clock Pins Cyclone II devices have either 20 dual-purpose clock pins, larger Cyclone II devices (EP2C15 devices and higher), there are
20 DPCLK pins; four on the left and right sides and six on the top and
bottom of the device. The corner CDPCLK pins are first multiplexed before they drive into the clock control block. Since the signals pass through a multiplexer before feeding the clock control block, these signals incur more delay to the clock control block than other DPCLK pins that directly feed the clock control block. In the smaller Cyclone II devices (EP2C5 and EP2C8 devices), there are eight DPCLK pins; two on each side of the device (see Figures 2–11 and 2–12). A programmable delay chain is available from the DPCLK pin to its fan- out destinations. To set the propagation delay from the DPCLK pin to its fan-out destinations, use the Input Delay from Dual-Purpose Clock Pin to Fan-Out Destinations assignment in the Quartus II software. These dual-purpose pins can connect to the global clock network for high-fanout control signals such as clocks, asynchronous clears, presets, and clock enables, or protocol control signals such as TRDY and IRDY for PCI, or DQS signals for external memory interfaces.
Altera Corporation 2–21 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Global Clock Network The 16 or 8 global clock networks drive throughout the entire device. Dedicated clock pins (CLK[]), PLL outputs, the logic array, and dual-purpose clock (DPCLK[]) pins can also drive the global clock network. The global clock network can provide clocks for all resources within the device, such as IOEs, LEs, memory blocks, and embedded multipliers. The global clock lines can also be used for control signals, such as clock enables and synchronous or asynchronous clears fed from the external pin, or DQS signals for DDR SDRAM or QDRII SRAM interfaces. Internal logic can also drive the global clock network for internally generated global clocks and asynchronous clears, clock enables, or other control signals with large fan-out. Clock Control Block There is a clock control block for each global clock network available in Cyclone II devices. The clock control blocks are arranged on the device periphery and there are a maximum of 16 clock control blocks available per Cyclone II device. The larger Cyclone II devices (EP2C15 devices and larger) have 16 clock control blocks, four on each side of the device. The smaller Cyclone II devices (EP2C5 and EP2C8 devices) have eight clock control blocks, four on the left and right sides of the device. The control block has these functions: ■ Dynamic global clock network clock source selection ■ Dynamic enable/disable of the global clock network In Cyclone II devices, the dedicated CLK[] pins, PLL counter outputs, DPCLK[] pins, and internal logic can all feed the clock control block. The output from the clock control block in turn feeds the corresponding global clock network. The following sources can be inputs to a given clock control block: ■ Four clock pins on the same side as the clock control block ■ Three PLL clock outputs from a PLL ■ Four DPCLK pins (including CDPCLK pins) on the same side as the clock control block ■ Four internally-generated signals
2–22 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Global Clock Network & Phase-Locked Loops Of the sources listed, only two clock pins, two PLL clock outputs, one DPCLK pin, and one internally-generated signal are chosen to drive into a clock control block. Figure 2–13 shows a more detailed diagram of the clock control block. Out of these six inputs, the two clock input pins and two PLL outputs can be dynamic selected to feed a global clock network. The clock control block supports static selection of DPCLK and the signal from internal logic. Figure 2–13. Clock Control Block Notes to Figure 2–13: (1) The CLKSWITCH signal can either be set through the configuration file or it can be dynamically set when using the manual PLL switchover feature. The output of the multiplexer is the input reference clock (fIN) for the PLL. (2) The CLKSELECT[1..0] signals are fed by internal logic and can be used to dynamically select the clock source for the global clock network when the device is in user mode. (3) The static clock select signals are se t in the configuration file and cannot be dynamically controlled when the device is in user mode. (4) Internal logic can be used to enabled or di sabled the global clock network in user mode. CLKSWITCH (1) Static Clock Select (3) Static Clock Select (3) Internal Logic Clock Control Block DPCLK or CDPCLK CLKSELECT[1..0] (2) CLKENA (4) inclk1 inclk0 CLK[n + 3] CLK[n + 2] CLK[n + 1] CLK[n] fIN C2PLL Global Clock Enable/ Disable (3)
Altera Corporation 2–23 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Global Clock Network Distribution Cyclone II devices contains 16 global clock networks. The device uses multiplexers with these clocks to form six-bit buses to drive column IOE clocks, LAB row clocks, or row IOE clocks (see Figure 2–14). Another multiplexer at the LAB level selects two of the six LAB row clocks to feed the LE registers within the LAB. Figure 2–14. Global Clock Network Multiplexers LAB row clocks can feed LEs, M4K memory blocks, and embedded multipliers. The LAB row clocks also extend to the row I/O clock regions. IOE clocks are associated with row or column block regions. Only six global clock resources feed to these row and column regions. Figure 2–15 shows the I/O clock regions. Clock [15 or 7..0] Row I/O Region IO_CLK [5..0] Column I/O Region IO_CLK [5..0] LAB Row Clock LABCLK[5..0] Global Clock Network
2–24 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Global Clock Network & Phase-Locked Loops Figure 2–15. LAB & I/O Clock Regions f For more information on the global clock network and the clock control block, see the PLLs in Cyclone II Devices chapter in Volume 1 of the Cyclone II Device Handbook. Column I/O Clock Region IO_CLK[5..0] Column I/O Clock Region IO_CLK[5..0] I/O Clock Regions I/O Clock Regions 8 or 16 Global Clock Network Row I/O Clock Region IO_CLK[5..0] Cyclone Logic Array LAB Row Clocks labclk[5..0] LAB Row Clocks labclk[5..0] LAB Row Clocks labclk[5..0] LAB Row Clocks labclk[5..0] LAB Row Clocks labclk[5..0] LAB Row Clocks labclk[5..0] 6 6
Altera Corporation 2–25 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture PLLs Cyclone II PLLs provide general-purpose clocking as well as support for the following features: ■ Clock multiplication and division ■ Phase shifting ■ Programmable duty cycle ■ Up to three internal clock outputs ■ One dedicated external clock output ■ Clock outputs for differential I/O support ■ Manual clock switchover ■ Gated lock signal ■ Three different clock feedback modes ■ Control signals Cyclone II devices contain either two or four PLLs. Table 2–3 shows the PLLs available for each Cyclone II device. Table 2–3. Cyclone II Device PLL Availability Device PLL1 PLL2 PLL3 PLL4 EP2C5 vv EP2C8 vv EP2C15 vvv v EP2C20 vvv v EP2C35 vvv v EP2C50 vvv v EP2C70 vvv v
2–26 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Global Clock Network & Phase-Locked Loops Table 2–4 describes the PLL features in Cyclone II devices. Table 2–4. Cyclone II PLL Features Feature Description Clock multiplication and division m / (n × post-scale counter) m and post-scale counter values (C0 to C2) range from 1 to 32. n ranges from 1 to 4. Phase shift Cyclone II PLLs have an advan ced clock shift capability that enables programmable phase shifts in increments of at least 45°. The finest resolution of phase shifting is determined by the voltage control oscillator (VCO) period divided by 8 (for example, 1/1000 MHz/8 = down to 125-ps increments). Programmable duty cycle The programmable duty cycl e allows PLLs to generate clock outputs with a variable duty cycle. This feature is supported on each PLL post-scale counter (C0-C2). Number of internal clock outputs The Cyclone II PLL has three outputs which can drive the global clock network. One of these outputs (C2) can also drive a dedicated PLL<#>_OUT pin (single ended or differential). Number of external clock outputs The C2 output drives a dedicated PLL<#>_OUT pin. If the C2 output is not used to drive an external clock output, it can be used to drive the internal global clock network. The C2 output can concurrently drive the external clock output and internal global clock network. Manual clock switchover The Cyclone II PLLs suppor t manual switchover of the reference clock through internal logic. This enables you to switch between two reference input clocks during user mode for applications that may require clock redundancy or support for clocks with two different frequencies. Gated lock signal The lock output indicates that there is a stable clock output signal in phase with the reference clock. Cyclone II PLLs include a programmable counter that holds the lock signal low for a user-selected number of input clock transitions, allowing the PLL to lock before enabling the locked signal. Either a gated locked signal or an ungated locked signal from the locked port can drive internal logic or an output pin. Clock feedback modes In zero delay buffer mode , the external clock output pin is phase-aligned with the clock input pin for zero delay. In normal mode, the PLL compensates for the internal global clock network delay from the input clock pin to the clock port of the IOE output registers or registers in the logic array. In no compensation mode, the PLL does not compensate for any clock networks. Control signals The pllenable signal enables and disables the PLLs. The areset signal resets/resynchronizes the inputs for each PLL. The pfdena signal controls the phase frequency detector (PFD) output with a programmable gate.
2–28 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Embedded Memory Each M4K block can implement various types of memory with or without parity, including true dual-port, simple dual-port, and single-port RAM, ROM, and first-in first-out (FIFO) buffers. The M4K blocks support the following features: ■ 4,608 RAM bits ■ 250-MHz performance ■ True dual-port memory ■ Simple dual-port memory ■ Single-port memory ■ Byte enable ■ Parity bits ■ Shift register ■ FIFO buffer ■ ROM ■ Various clock modes ■ Address clock enable
1 Violating the setup or hold time on the memory block address
registers could corrupt memory contents. This applies to both read and write operations. Table 2–5 shows the capacity and distribution of the M4K memory blocks in each Cyclone II device. Table 2–5. M4K Memory Capacity & Distribution in Cyclone II Devices Device M4K Columns M4K Blocks Total RAM Bits EP2C5 2 26 119,808 EP2C8 2 36 165,888 EP2C15 2 52 239,616 EP2C20 2 52 239,616 EP2C35 3 105 483,840 EP2C50 3 129 594,432 EP2C70 5 250 1,152,000
Altera Corporation 2–29 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Table 2–6 summarizes the features supported by the M4K memory. Table 2–6. M4K Memory Features Feature Description Maximum performance (1) 250 MHz Total RAM bits per M4K block (including parity bits) 4,608 Configurations supported 4K × 1 2K × 2 1K × 4 512 × 8 512 × 9 256 × 16 256 × 18 128 × 32 (not available in true dual-port mode) 128 × 36 (not available in true dual-port mode) Parity bits One parity bit for each byte. The parity bit, along with internal user logic, can implement parity checking for error detection to ensure data integrity. Byte enable M4K blocks support byte writes when the write port has a data width of 1, 2, 4, 8, 9, 16, 18, 32, or 36 bits. The byte enables allow the input data to be masked so the device can write to specific bytes. The unwritten bytes retain the previous written value. Packed mode Two single-port memory blocks can be packed into a single M4K block if each of the two independent block sizes are equal to or less than half of the M4K block size, and each of the single-port memory blocks is configured in single-clock mode. Address clock enable M4K blocks s upport address clock enable, which is used to hold the previous address value for as long as the signal is enabled. This feature is useful in handling misses in cache applications. Memory initialization file (.mif) When configured as RAM or ROM, you can use an initialization file to pre-load the memory contents. Power-up condition Outputs cleared Register clears Out put registers only Same-port read-during-write New dat a available at positive clock edge Mixed-port read-during-write Old data available at positive clock edge Note to Table 2–6: (1) Maximum performance information is pr eliminary until device characterization.
2–30 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Embedded Memory Memory Modes Table 2–7 summarizes the different memory modes supported by the M4K memory blocks.
1 Embedded Memory can be inferred in your HDL code or
directly instantiated in the Quartus II software using the MegaWizard® Plug-in Manager Memory Compiler feature. Table 2–7. M4K Memory Modes Memory Mode Description Single-port memory M4K blocks suppo rt single-port mode, used when simultaneous reads and writes are not required. Single-port memory supports non-simultaneous reads and writes. Simple dual-port memory Simple dual-port memory supports a simultaneous read and write. Simple dual-port with mixed width Simple dual-port memory mode with different read and write port widths. True dual-port memory True dual-port mode supports any combination of two-port operations: two reads, two writes, or one read and one write at two different clock frequencies. True dual-port with mixed width True dual-port mode with different read and write port widths. Embedded shift register M4K memory bloc ks are used to implement shift registers. Data is written into each address location at the falling edge of the clock and read from the address at the rising edge of the clock. ROM The M4K memory blocks support ROM mode. A MIF initializes the ROM contents of these blocks. FIFO buffers A single clock or dual clock FIFO may be implemented in the M4K blocks. Simultaneous read and write from an empty FIFO buffer is not supported.
Altera Corporation 2–31 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Clock Modes Table 2–8 summarizes the different clock modes supported by the M4K memory. Table 2–9 shows which clock modes are supported by all M4K blocks when configured in the different memory modes. M4K Routing Interface The R4, C4, and direct link interconnects from adjacent LABs drive the M4K block local interconnect. The M4K blocks can communicate with LABs on either the left or right side through these row resources or with LAB columns on either the right or left with the column resources. Up to 16 direct link input connections to the M4K block are possible from the left adjacent LAB and another 16 possible from the right adjacent LAB. M4K block outputs can also connect to left and right LABs through each 16 direct link interconnects. Figure 2–17 shows the M4K block to logic array interface. Table 2–8. M4K Clock Modes Clock Mode Description Independent In this mode, a separate clock is available for each port (ports A and B). Clock A controls all registers on the port A side, while clock B controls all registers on the port B side. Input/output On each of the two ports, A or B, one clock controls all registers for inputs into the memory block: data input, wren, and address. The other clock controls the block’s data output registers. Read/write Up to two clocks are available in this mode. The write clock controls the block’s data inputs, wraddress, and wren. The read clock controls the data output, rdaddress, and rden. Single In this mode, a single clock, together with clock enable, is used to control all registers of the memory block. Asynchronous clear signals for the registers are not supported.Table 2–9. Cyclone II M4K Memory Clock Modes Clocking Modes True Dual-Port Mode Simple Dual-Port Mode Single-Port Mode Independent v Input/output vv v Read/write v Single clock vv v
2–32 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Embedded Multipliers Figure 2–17. M4K RAM Block LAB Row Interface f For more information on Cyclone II embedded memory, see the Cyclone II Memory Blocks chapter in Volume 1 of the Cyclone II Device Handbook. Embedded Multipliers Cyclone II devices have embedded multiplier blocks optimized for multiplier-intensive digital signal processing (DSP) functions, such as finite impulse response (FIR) filters, fast Fourier transform (FFT) functions, and discrete cosine transform (DCT) functions. You can use the embedded multiplier in one of two basic operational modes, depending on the application needs: ■ One 18-bit multiplier ■ Up to two independent 9-bit multipliers dataout M4K RAM Block datainaddress 16 16Direct link interconnect from adjacent LAB Direct link interconnect to adjacent LAB Direct link interconnect from adjacent LAB Direct link interconnect to adjacent LAB M4K RAM Block Local Interconnect Region C4 Interconnects R4 Interconnects LAB Row Clocks Clocks Byte enable Control Signals
Altera Corporation 2–33 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Embedded multipliers can operate at up to 250 MHz (for the fastest speed grade) for 18 × 18 and 9 × 9 multiplications when using both input and output registers. Each Cyclone II device has one to three columns of embedded multipliers that efficiently implement multiplication functions. An embedded multiplier spans the height of one LAB row. Table 2–10 shows the number of embedded multipliers in each Cyclone II device and the multipliers that can be implemented. The embedded multiplier consists of the following elements: ■ Multiplier block ■ Input and output registers ■ Input and output interfaces Figure 2–18 shows the multiplier block architecture. Table 2–10. Number of Embedded Multipliers in Cyclone II Devices Note (1) Device Embedded Multiplier Columns Embedded Multipliers 9 × 9 Multipliers 18 × 18 Multipliers EP2C5 1 13 26 13 EP2C8 1 18 36 18 EP2C15 1 26 52 26 EP2C20 1 26 52 26 EP2C35 1 35 70 35 EP2C50 2 86 172 86 EP2C70 3 150 300 150 Note to Table 2–10: (1) Each device has either the number of 9 × 9-, or 18 × 18-bit multipliers shown. The total number of multipliers for each device is not the sum of all the multipliers.
2–34 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Embedded Multipliers Figure 2–18. Multiplier Block Architecture Note to Figure 2–18: (1) If necessary, these signals can be registered once to match the data signal path. Each multiplier operand can be a unique signed or unsigned number. Two signals, signa and signb, control the representation of each operand respectively. A logic 1 value on the signa signal indicates that data A is a signed number while a logic 0 value indicates an unsigned number. Table 2–11 shows the sign of the multiplication result for the various operand sign representations. The result of the multiplication is signed if any one of the operands is a signed value. CLRN DQ ENA Data A Data B aclr clock ena signa (1) signb (1) CLRN DQ ENA CLRN DQ ENA Data Out Embedded Multiplier Block Output RegisterInput Register Table 2–11. Multiplier Sign Representation Data A (signa Value) Data B (signb Value) Result Unsigned Unsigned Unsigned Unsigned Signed Signed Signed Unsigned Signed Signed Signed Signed
Altera Corporation 2–35 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture There is only one signa and one signb signal for each dedicated multiplier. Therefore, all of the data A inputs feeding the same dedicated multiplier must have the same sign representation. Similarly, all of the data B inputs feeding the same dedicated multiplier must have the same sign representation. The signa and signb signals can be changed dynamically to modify the sign representation of the input operands at run time. The multiplier offers full precision regardless of the sign representation and can be registered using dedicated registers located at the input register stage. Multiplier Modes Table 2–12 summarizes the different modes that the embedded multipliers can operate in. Table 2–12. Embedded Multiplier Modes Multiplier Mode Description 18-bit Multiplier An embedded multiplier can be configured to support a single 18 × 18 multiplier for operand widths up to 18 bits. All 18-bit multiplier inputs and results can be registered independently. The multiplier operands can accept signed integers, unsigned integers, or a combination of both. 9-bit Multiplier An embedded multipli er can be configured to support two 9 × 9 independent multipliers for operand widths up to 9-bits. Both 9-bit multiplier inputs and results can be registered independently. The multiplier operands can accept signed integers, unsigned integers or a combination of both. There is only one signa signal to control the sign representation of both data A inputs and one signb signal to control the sign representation of both data B inputs of the 9-bit multipliers within the same dedicated multiplier.
2–36 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Embedded Multipliers Embedded Multiplier Routing Interface The R4, C4, and direct link interconnects from adjacent LABs drive the embedded multiplier row interface interconnect. The embedded multipliers can communicate with LABs on either the left or right side through these row resources or with LAB columns on either the right or left with the column resources. Up to 16 direct link input connections to the embedded multiplier are possible from the left adjacent LABs and another 16 possible from the right adjacent LAB. Embedded multiplier outputs can also connect to left and right LABs through 18 direct link interconnects each. Figure 2–19 shows the embedded multiplier to logic array interface. Figure 2–19. Embedded Multiplier LAB Row Interface LAB LAB Row Interface Block Embedded Multiplier [35..0][35..0] Embedded Multiplier to LAB Row Interface Block Interconnect Region
36 Inputs per Row 36 Outputs per Row
R4 InterconnectsC4 Interconnects C4 Interconnects Direct Link Interconnect from Adjacent LAB
18 Direct Link Outputs
Altera Corporation 2–37 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture There are five dynamic control input signals that feed the embedded multiplier: signa, signb, clk, clkena, and aclr. signa and signb can be registered to match the data signal input path. The same clk, clkena, and aclr signals feed all registers within a single embedded multiplier. f For more information on Cyclone II embedded multipliers, see the Embedded Multipliers in Cyclone II Devices chapter. I/O Structure & IOEs support many features, including: ■ Differential and single-ended I/O standards ■ 3.3-V , 64- and 32-bit, 66- and 33-MHz PCI compliance ■ Joint Test Action Group (JTAG) boundary-scan test (BST) support ■ Output drive strength control ■ Weak pull-up resistors during configuration ■ Tri-state buffers ■ Bus-hold circuitry ■ Programmable pull-up resistors in user mode ■ Programmable input and output delays ■ Open-drain outputs ■ DQ and DQS I/O pins ■ VREF pins Cyclone II device IOEs contain a bidirectional I/O buffer and three registers for complete embedded bidirectional single data rate transfer. Figure 2–20 shows the Cyclone II IOE structure. The IOE contains one input register, one output register, and one output enable register. You can use the input registers for fast setup times and output registers for fast clock-to-output times. Additionally, you can use the output enable (OE) register for fast clock-to-output enable timing. The Quartus II software automatically duplicates a single OE register that controls multiple output or bidirectional pins. You can use IOEs as input, output, or bidirectional pins.
Altera Corporation 2–39 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Figure 2–21. Row I/O Block Connection to the Interconnect Notes to Figure 2–21: (1) The 35 data and control signals consist of five data out lines, io_dataout[4..0], five output enables, five clocks, io_cclk[4..0], five asynchronous clear signals, io_caclr[4..0], and five synchronous clear signals, io_csclr[4..0]. (2) Each of the five IOEs in the row I/O block can have two io_datain (combinational or registered) inputs. R4 & R24 Interconnects C4 Interconnects I/O Block Local Interconnect
35 Data and
from Logic Array (1 io_datain0[4..0] io_datain1[4..0] (2) io_clk[5..0] Row I/O Block Contains up to Five IOEs Direct Link Interconnect to Adjacent LAB Direct Link Interconnect from Adjacent LAB LAB Local Interconnect LAB Row I/O Block
2–40 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Figure 2–22. Column I/O Block Connection to the Interconnect Notes to Figure 2–22: (1) The 28 data and control signals consist of four data out lines, io_dataout[3..0], four output enables, four clocks, io_cclk[3..0], four asynchronous clear signals, io_caclr[3..0], and four synchronous clear signals, io_csclr[3..0]. (2) Each of the four IOEs in the column I/O block can have two io_datain (combinational or registered) inputs.
28 Data &
from Logic Array (1) Column I/O Block Contains up to Four IOE s I/O Block Local Interconnect io_datain0[3..0] io_datain1[3..0] (2) R4 & R24 Interconnects LAB Local Interconnect C4 & C24 Interconnects LAB LAB LAB io_clk[5..0] Column I/O Block
2–42 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Figure 2–24. Control Signal Selection per IOE In normal bidirectional operation, you can use the input register for input data requiring fast setup times. The input register can have its own clock input and clock enable separate from the OE and output registers. You can use the output register for data requiring fast clock-to-output performance. The OE register is available for fast clock-to-output enable timing. The OE and output register share the same clock source and the same clock enable source from the local interconnect in the associated LAB, dedicated I/O clocks, or the column and row interconnects. All registers share sclr and aclr, but each register can individually disable sclr and aclr. Figure 2–25 shows the IOE in bidirectional configuration. clk_out ce_inclk_in ce_out aclr/preset sclr/preset Dedicated I/O Clock [5..0] Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect oe io_coe io_caclr Local Interconnect io_csclr io_cce_out io_cce_in io_cclk
Altera Corporation 2–43 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Figure 2–25. Cyclone II IOE in Bidirectional I/O Configuration The Cyclone II device IOE includes programmable delays to ensure zero hold times, minimize setup times, or increase clock to output times. A path in which a pin directly drives a register may require a programmable delay to ensure zero hold time, whereas a path in which a pin drives a register through combinational logic may not require the delay. Programmable delays decrease input-pin-to-logic-array and IOE input register delays. The Quartus II Compiler can program these delays to automatically minimize setup time while providing a zero hold time. Chip-Wide Reset OE Register VCCIO Optional PCI Clamp Column or Row Interconect io_clk[5..0] Input Register Input Pin to Input Register Delay or Input Pin to Logic Array Delay Open-Drain Outputsclr/preset OE clkout ce_out aclr/prn clkin ce_in Output Pin Delay Programmable Pull-Up Resistor Bus Hold PRN CLRN DQ Output Register PRN CLRN DQ PRN CLRN DQ VCCIO data_in0 data_in1 ENA ENA ENA
2–44 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Programmable delays can increase the register-to-pin delays for output registers. Table 2–13 shows the programmable delays for Cyclone II devices. There are two paths in the IOE for an input to reach the logic array. Each of the two paths can have a different delay. This allows you to adjust delays from the pin to internal LE registers that reside in two different areas of the device. You set the two combinational input delays by selecting different delays for two different paths under the Input delay from pin to internal cells logic option in the Quartus II software. However, if the pin uses the input register, one of delays is disregarded because the IOE only has two paths to internal logic. If the input register is used, the IOE uses one input path. The other input path is then available for the combinational path, and only one input delay assignment is applied. The IOE registers in each I/O block share the same source for clear or preset. You can program preset or clear for each individual IOE, but both features cannot be used simultaneously. You can also program the registers to power up high or low after configuration is complete. If programmed to power up low, an asynchronous clear can control the registers. If programmed to power up high, an asynchronous preset can control the registers. This feature prevents the inadvertent activation of another device’s active-low input upon power up. If one register in an IOE uses a preset or clear signal then all registers in the IOE must use that same signal if they require preset or clear. Additionally a synchronous reset signal is available for the IOE registers. External Memory Interfacing Cyclone II devices support a broad range of external memory interfaces such as SDR SDRAM, DDR SDRAM, DDR2 SDRAM, and QDRII SRAM external memories. Cyclone II devices feature dedicated high-speed interfaces that transfer data between external memory devices at up to
167 MHz/333 Mbps for DDR and DDR2 SDRAM devices and
167 MHz/667 Mbps for QDRII SRAM devices. The programmable DQS delay chain allows you to fine tune the phase shift for the input clocks or strobes to properly align clock edges as needed to capture data. Table 2–13. Cyclone II Programmable Delay Chain Programmable Delays Quartus II Logic Option Input pin to logic array delay Input delay from pin to internal cells Input pin to input register delay Input delay from pin to input register Output pin delay Delay from output register to output pin
Altera Corporation 2–45 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture In Cyclone II devices, all the I/O banks support SDR and DDR SDRAM memory up to 167 MHz/333 Mbps. All I/O banks support DQS signals with the DQ bus modes of ×8/×9, or ×16/×18. Table 2–14 shows the external memory interfaces supported in Cyclone II devices. Cyclone II devices use data (DQ), data strobe (DQS), and clock pins to interface with external memory. Figure 2–26 shows the DQ and DQS pins in the ×8/×9 mode. Table 2–14. External Memory Support in Cyclone II Devices Note (1) Memory Standard I/O Standard Maximum Bus Width Maximum Clock Rate Supported (MHz) Maximum Data Rate Supported (Mbps) SDR SDRAM LVTTL (2) 72 167 167 DDR SDRAM SSTL-2 class I (2) 72 167 333 (1) SSTL-2 class II (2) 72 133 267 (1) DDR2 SDRAM SSTL-18 class I (2) 72 167 333 (1) SSTL-18 class II (3) 72 125 250 (1) QDRII SRAM (4) 1.8-V HSTL class I (2) 36 167 668 (1) 1.8-V HSTL class II (3) 36 100 400 (1) Notes to T able 2–14: (1) The data rate is for designs using the Clock Delay Control circuitry . (2) The I/O standards are supported on al l the I/O banks of the Cyclone II device. (3) The I/O standards are supported only on the I/O ba nks on the top and bottom of the Cyclone II device. (4) For maximum performance, Altera recommends using the 1.8-V HSTL I/O standard because of higher I/O drive strength. QDRII SRAM devices also support the 1.5-V HSTL I/O standard.
2–46 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Figure 2–26. Cyclone II Device DQ & DQS Groups in ×8/×9 Mode Notes (1), (2) Notes to Figure 2–26: (1) Each DQ group consists of a DQS pin, DM pin, and up to nine DQ pins. (2) This is an idealized pin layout. For actual pin layout, refer to the pin table. Cyclone II devices support the data strobe or read clock signal (DQS) used in DDR and DDR2 SDRAM. Cyclone II devices can use either bidirectional data strobes or unidirectional read clocks. The dedicated external memory interface in Cyclone II devices also includes programmable delay circuitry that can shift the incoming DQS signals to center align the DQS signals within the data window. The DQS signal is usually associated with a group of data (DQ) pins. The phase-shifted DQS signals drive the global clock network, which is used to clock the DQ signals on internal LE registers. Table 2–15 shows the number of DQ pin groups per device. DQ Pins DQS Pin DM PinDQ Pins(2) Table 2–15. Cyclone II DQS & DQ Bus Mode Support (Part 1 of 2) Note (1) Device Package Number of ×8 Groups Number of ×9 Groups (5), (6) Number of ×16 Groups Number of ×18 Groups (5), (6) EP2C5 144-pin TQFP (2) 3 300 208-pin PQFP 7 (3) 433 EP2C8 144-pin TQFP (2) 3 300 208-pin PQFP 7 (3) 433 256-pin FineLine BGA® 8 (3) 444 EP2C15 256-pin FineLine BGA 8 4 4 4 484-pin FineLine BGA 16 (4) 888 EP2C20 256-pin FineLine BGA 8 4 4 4 484-pin FineLine BGA 16 (4) 888
Altera Corporation 2–47 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture You can use any of the DQ pins for the parity pins in Cyclone II devices. The Cyclone II device family supports parity in the ×8/×9, and ×16/×18 mode. There is one parity bit available per eight bits of data pins. The data mask, DM, pins are required when writing to DDR SDRAM and DDR2 SDRAM devices. A low signal on the DM pin indicates that the write is valid. If the DM signal is high, the memory masks the DQ signals. In Cyclone II devices, the DM pins are assigned and are the preferred pins. Each group of DQS and DQ signals requires a DM pin. When using the Cyclone II I/O banks to interface with the DDR memory, at least one PLL with two clock outputs is needed to generate the system and write clock. The system clock is used to clock the DQS write signals, commands, and addresses. The write clock is shifted by –90° from the system clock and is used to clock the DQ signals during writes. Figure 2–27 illustrates DDR SDRAM interfacing from the I/O through the dedicated circuitry to the logic array. EP2C35 484-pin FineLine BGA 16 (4) 888 672-pin FineLine BGA 20 (4) 888 EP2C50 484-pin FineLine BGA 16 (4) 888 672-pin FineLine BGA 20 (4) 888 EP2C70 672-pin FineLine BGA 20 (4) 888 896-pin FineLine BGA 20 (4) 888 Notes to T able 2–15: (1) Numbers are preliminary. (2) EP2C5 and EP2C8 devices in the 144-pin TQFP package do not have any DQ pin groups in I/O bank 1. (3) Because of available clock resources, only a total of 6 DQ/DQS groups can be implemented. (4) Because of available clock resources, only a total of 14 DQ/DQS groups can be implemented. (5) The ×9 DQS/DQ groups are also used as ×8 DQS/DQ groups. The ×18 DQS/DQ groups are also used as ×16 DQS/DQ groups. (6) For QDRI implementation, if you connect the D ports (wri te data) to the Cyclone II DQ pins, the total available ×9 DQS /DQ and ×18 DQS/DQ groups are half of that shown in Table 2–15. Table 2–15. Cyclone II DQS & DQ Bus Mode Support (Part 2 of 2) Note (1) Device Package Number of ×8 Groups Number of ×9 Groups (5), (6) Number of ×16 Groups Number of ×18 Groups (5), (6)
2–48 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Figure 2–27. DDR SDRAM Interfacing f For more information on Cyclone II external memory interfaces, see the External Memory Interfaces chapter in Volume 1 of the Cyclone II Device Handbook. DQS OE VCC PLL GND clk DQ OE DataA DataB Resynchronizing to System Clock Global Clock Clock Delay Control Circuitry -90˚ Shifted clk Adjacent LAB LEs Clock Control Block LE Register LE Register LE Register LE Register t en/dis Dynamic Enable/Disable Circuitry ENOUT ena_register_mode LE Register LE Register LE Register LE Register LE Register LE Register LE Register LE Register LE Register
Altera Corporation 2–49 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Programmable Drive Strength The output buffer for each Cyclone II device I/O pin has a programmable drive strength control for certain I/O standards. The LVTTL, LVCMOS, SSTL-2 class I and II, SSTL-18 class I and II, HSTL-18 class I and II, and HSTL-1.5 class I and II standards have several levels of drive strength that you can control. Using minimum settings provides signal slew rate control to reduce system noise and signal overshoot. Table 2–16 shows the possible settings for the I/O standards with drive strength control. Table 2–16. Programmable Drive Strength (Part 1 of 2) Note (1) I/O Standard IOH/IOL Current Strength Setting (mA) Top & Bottom I/O Pins Side I/O Pins LVTTL (3.3 V) 4 4 12 12 16 16 20 20 24 24 LVCMOS (3.3 V) 4 4 12 12 LVTTL/LVCMOS (2.5 V) 4 4 LVTTL/LVCMOS (1.8 V) 2 2 10 10 12 12
2–50 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Open-Drain Output Cyclone II devices provide an optional open-drain (equivalent to an open-collector) output for each I/O pin. This open-drain output enables the device to provide system-level control signals (that is, interrupt and write-enable signals) that can be asserted by any of several devices. LVCMOS (1.5 V) 2 2 SSTL-2 class I 8 8 12 12 SSTL-2 class II 16 16 SSTL-18 class I 6 6 10 10 SSTL-18 class II 16 HSTL-18 class I 8 8 10 10 12 12 HSTL-18 class II 16 HSTL-15 class I 8 8 HSTL-15 class II 16 Note to T able 2–16: (1) The default current in the Quartus II software is the maximum setting for each I/O standard. Table 2–16. Programmable Drive Strength (Part 2 of 2) Note (1) I/O Standard IOH/IOL Current Strength Setting (mA) Top & Bottom I/O Pins Side I/O Pins
Altera Corporation 2–51 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Slew Rate Control Slew rate control is performed by using programmable output drive strength. Bus Hold Each Cyclone II device user I/O pin provides an optional bus-hold feature. The bus-hold circuitry can hold the signal on an I/O pin at its last-driven state. Since the bus-hold feature holds the last-driven state of the pin until the next input signal is present, an external pull-up or pull-down resistor is not necessary to hold a signal level when the bus is tri-stated. The bus-hold circuitry also pulls undriven pins away from the input threshold voltage where noise can cause unintended high-frequency switching. You can select this feature individually for each I/O pin. The bus-hold output drives no higher than V CCIO to prevent overdriving signals.
1 If the bus-hold feature is enabled, the device cannot use the
programmable pull-up option. Disable the bus-hold feature when the I/O pin is configured for differential signals. Bus hold circuitry is not available on the dedicated clock pins. The bus-hold circuitry is only active after configuration. When going into user mode, the bus-hold circuit captures the value on the pin present at the end of configuration. The bus-hold circuitry uses a resistor with a nominal resistance (RBH) of approximately 7 kΩ to pull the signal level to the last-driven state. Refer to the DC Characteristics & Timing Specifications chapter in Volume 1 of the Cyclone II Device Handbook for the specific sustaining current for each VCCIO voltage level driven through the resistor and overdrive current used to identify the next driven input level. Programmable Pull-Up Resistor Each Cyclone II device I/O pin provides an optional programmable pull-up resistor during user mode. If you enable this feature for an I/O pin, the pull-up resistor (typically 25 kΩ) holds the output to the VCCIO level of the output pin’s bank.
1 If the programmable pull-up is enabled, the device cannot use
the bus-hold feature. The programmable pull-up resistors are not supported on the dedicated configuration, JTAG, and dedicated clock pins.
2–52 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Advanced I/O Standard Support Table 2–17 shows the I/O standards supported by Cyclone II devices and which I/O pins support them. Table 2–17. Cyclone II Supported I/O Standards & Constraints (Part 1 of 2) I/O Standard Type VCCIO Level Top & Bottom I/O Pins Side I/O Pins Input Output CLK, DQS User I/O Pins CLK, DQS PLL_OUT User I/O Pins 3.3-V LVTTL and LVCMOS (1) Single ended 3.3 V/ 2.5 V
3.3 V vvv v v
2.5-V LVTTL and LVCMOS Single ended 3.3 V/ 2.5 V
2.5 V vvv v v
1.8-V LVTTL and LVCMOS Single ended 1.8 V/ 1.5 V
1.8 V vvv v v
1.5-V LVCMOS Single ended 1.8 V/ 1.5 V
1.5 V vvv v v
2.5 V 2.5 V vvv v v SSTL-2 class II Voltage referenced 2.5 V 2.5 V vvv v v SSTL-18 class I Voltage referenced 1.8 V 1.8 V vvv v v SSTL-18 class II Voltage referenced HSTL-18 class I Voltage referenced 1.8 V 1.8 V vvv v v HSTL-18 class II Voltage referenced HSTL-15 class I Voltage referenced 1.5 V 1.5 V vvv v v HSTL-15 class II Voltage referenced PCI and PCI-X (1) (3) Single ended 3.3 V 3.3 V vv v Differential SSTL-2 class I or class II Pseudo differential (4) (5) 2.5 V v
2.5 V (5) v
(6) v (6) Differential SSTL-18 class I or class II Pseudo differential (4) (5) 1.8 V v (7)
1.8 V (5) v
(6) v (6)
Altera Corporation 2–53 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture f For more information on Cyclone II supported I/O standards, see the Selectable I/O Standards in Cyclone II Devices chapter in Volume 1 of the Cyclone II Device Handbook. High-Speed Differential Interfaces Cyclone II devices can transmit and receive data through LVDS signals at a data rate of up to 640 Mbps and 805 Mbps, respectively. For the LVDS transmitter and receiver, the Cyclone II device’s input and output pins support serialization and deserialization through internal logic. Differential HSTL-15 class I or class II Pseudo differential (4) (5) 1.5 V v (7)
1.5 V (5) v
(6) v (6) Differential HSTL-18 class I or class II Pseudo differential (4) (5) 1.8 V v (7) (6) v (6) LVDS Differential 2.5 V 2.5 V vvv v v RSDS and mini-LVDS (8) Differential (5) 2.5 V vv v LVPECL (9) Differential 3.3 V/ 2.5 V/ 1.8 V/ 1.5 V (5) vv Notes to T able 2–17: (1) To drive inputs higher than V CCIO but less than 4.0 V , disable the PCI clamping diode and turn on the Allow LVTTL and LVCMOS input levels to overdrive input buffer option in the Quartus II software. (2) These pins support SSTL-18 class II an d 1.8- and 1.5-V HSTL class II inputs. (3) PCI-X does not meet the IV curve requirement at the linear region. PCI-clamp diode is not available on top and bottom I/O pins. (4) Pseudo-differential HSTL and SSTL outputs use two si ngle-ended outputs with the second output programmed as inverted. Pseudo-differential HSTL and SSTL inputs treat differential inputs as two single-ended HSTL and SSTL inputs and only decode one of them. (5) This I/O standard is not supported on these I/O pins. (6) This I/O standard is only suppo rted on the dedicated clock pins. (7) PLL_OUT does not support differential SSTL-18 class II and differential 1.8 and 1.5-V HSTL class II. (8) mini-LVDS and RSDS are only supported on output pins. (9) LVPECL is only supported on clock inputs. Table 2–17. Cyclone II Supported I/O Standards & Constraints (Part 2 of 2) I/O Standard Type VCCIO Level Top & Bottom I/O Pins Side I/O Pins Input Output CLK, DQS User I/O Pins CLK, DQS PLL_OUT User I/O Pins
2–54 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features The reduced swing differential signaling (RSDS) and mini-LVDS standards are derivatives of the LVDS standard. The RSDS and mini-LVDS I/O standards are similar in electrical characteristics to LVDS, but have a smaller voltage swing and therefore provide increased power benefits and reduced electromagnetic interference (EMI). Cyclone II devices support the RSDS and mini-LVDS I/O standards at data rates up to 311 Mbps at the transmitter. A subset of pins in each I/O bank (on both rows and columns) support the high-speed I/O interface. The dual-purpose LVDS pins require an external-resistor network at the transmitter channels in addition to 100-Ω termination resistors on receiver channels. These pins do not contain dedicated serialization or deserialization circuitry. Therefore, internal logic performs serialization and deserialization functions. Cyclone II pin tables list the pins that support the high-speed I/O interface. The number of LVDS channels supported in each device family member is listed in Table 2–18. Table 2–18. Cyclone II Device LVDS Channels (Part 1 of 2) Device Pin Count Number of LVDS Channels (1) EP2C5 144 31 (35) 208 56 (60) 256 61 (65) EP2C8 144 29 (33) 208 53 (57) 256 75 (79) EP2C15 256 52 (60) 484 128 (136) EP2C20 240 45 (53) 256 52 (60) 484 128 (136) EP2C35 484 131 (139) 672 201 (209) EP2C50 484 119 (127) 672 189 (197)
Altera Corporation 2–55 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture You can use I/O pins and internal logic to implement a high-speed I/O receiver and transmitter in Cyclone II devices. Cyclone II devices do not contain dedicated serialization or deserialization circuitry. Therefore, shift registers, internal PLLs, and IOEs are used to perform serial-to-parallel conversions on incoming data and parallel-to-serial conversion on outgoing data. The maximum internal clock frequency for a receiver and for a transmitter is 402.5 MHz. The maximum input data rate of 805 Mbps and the maximum output data rate of 640 Mbps is only achieved when DDIO registers are used. The LVDS standard does not require an input reference voltage, but it does require a 100-Ω termination resistor between the two signals at the input buffer. An external resistor network is required on the transmitter side. f For more information on Cyclone II differential I/O interfaces, see the High-Speed Differential Interfaces in Cyclone II Devices chapter in Volume 1 of the Cyclone II Device Handbook. Series On-Chip Termination On-chip termination helps to prevent reflections and maintain signal integrity. This also minimizes the need for external resistors in high pin count ball grid array (BGA) packages. Cyclone II devices provide I/O driver on-chip impedance matching and on-chip series termination for single-ended outputs and bidirectional pins. EP2C70 672 160 (168) 896 257 (265) Note to T able 2–18: (1) The first number represents the number of bidirectional I/O pins which can be used as inputs or outputs. The number in parenthesis includes dedicated clock input pin pairs which can only be used as inputs. Table 2–18. Cyclone II Device LVDS Channels (Part 2 of 2) Device Pin Count Number of LVDS Channels (1)
2–56 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Cyclone II devices support driver impedance matching to the impedance of the transmission line, typically 25 or 50 Ω. When used with the output drivers, on-chip termination sets the output driver impedance to 25 or 50 Ω. Cyclone II devices also support I/O driver series termination (RS = 50 Ω) for SSTL-2 and SSTL-18. Table 2–19 lists the I/O standards that support impedance matching and series termination.
1 The recommended frequency range of operation is pending
silicon characterization. On-chip series termination can be supported on any I/O bank. VCCIO and VREF must be compatible for all I/O pins in order to enable on-chip series termination in a given I/O bank. I/O standards that support different RS values can reside in the same I/O bank as long as their VCCIO and VREF are not conflicting.
1 When using on-chip series termination, programmable drive
strength is not available. Impedance matching is implemented using the capabilities of the output driver and is subject to a certain degree of variation, depending on the process, voltage and temperature. The actual tolerance is pending silicon characterization. Table 2–19. I/O Standards Supporting Series Termination Note (1) I/O Standards Target RS (Ω)V CCIO (V) 3.3-V LVTTL and LVCMOS 25 (2) 3.3 2.5-V LVTTL and LVCMOS 50 (2) 2.5 1.8-V LVTTL and LVCMOS 50 (2) 1.8 SSTL-2 class I 50 (2) 2.5 SSTL-18 class I 50 (2) 1.8 Notes to Tab le 2–19: (1) Supported conditions are V CCIO =V CCIO ±50 mV . (2) These R S values are nominal values. Actual impedance varies across process, voltage, and temperature conditions.
Altera Corporation 2–57 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture I/O Banks The I/O pins on Cyclone II devices are grouped together into I/O banks and each bank has a separate power bus. EP2C5 and EP2C8 devices have four I/O banks (see Figure 2–28), while EP2C15, EP2C20, EP2C35, EP2C50, and EP2C70 devices have eight I/O banks (see Figure 2–29). Each device I/O pin is associated with one I/O bank. To accommodate voltage-referenced I/O standards, each Cyclone II I/O bank has a VREF bus. Each bank in EP2C5, EP2C8, EP2C15, EP2C20, EP2C35, and EP2C50 devices supports two VREF pins and each bank of EP2C70 supports four VREF pins. When using the VREF pins, each VREF pin must be properly connected to the appropriate voltage level. In the event these pins are not used as VREF pins, they may be used as regular I/O pins. The top and bottom I/O banks (banks 2 and 4 in EP2C5 and EP2C8 devices and banks 3, 4, 7, and 8 in EP2C15, EP2C20, EP2C35, EP2C50, and EP2C70 devices) support all I/O standards listed in Table 2–17, except the PCI/PCI-X I/O standards. The left and right side I/O banks (banks 1 and 3 in EP2C5 and EP2C8 devices and banks 1, 2, 5, and 6 in EP2C15, EP2C20, EP2C35, EP2C50, and EP2C70 devices) support I/O standards listed in Table 2–17, except SSTL-18 class II, HSTL-18 class II, and HSTL-15 class II I/O standards. See Table 2–17 for a complete list of supported I/O standards. The top and bottom I/O banks (banks 2 and 4 in EP2C5 and EP2C8 devices and banks 3, 4, 7, and 8 in EP2C15, EP2C20, EP2C35, EP2C50, and EP2C70 devices) support DDR2 memory up to 167 MHz/333 Mbps and QDR memory up to 167 MHz/668 Mbps. The left and right side I/O banks (1 and 3 of EP2C5 and EP2C8 devices and 1, 2, 5, and 6 of EP2C15, EP2C20, EP2C35, EP2C50, and EP2C70 devices) only support SDR and DDR SDRAM interfaces. All the I/O banks of the Cyclone II devices support SDR memory up to 167 MHz/167 Mbps and DDR memory up to 167 MHz/333 Mbps.
1 DDR2 and QDRII interfaces may be implemented in Cyclone II
side banks if the use of class I I/O standard is acceptable.
2–58 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features Figure 2–28. EP2C5 & EP2C8 I/O Banks Notes (1), (2) Notes to Figure 2–28: (1) This is a top view of the silicon die. (2) This is a graphic representation only. Refer to the pi n list and the Quartus II software for exact pin locations. (3) The LVPECL I/O standard is only su pported on clock input pins. This I/O standard is not supported on output pins. (4) The differential SSTL-18 and SSTL-2 I/O standards are only supported on clock input pins and PLL output clock pins. (5) The differential 1.8-V and 1.5-V HSTL I/O standards are only supported on clock input pins and PLL output clock pins. I/O Bank 2 I/O Bank 3 I/O Bank 4 I/O Bank 1 All I/O Banks Support ■ 3.3-V LVTTL/LVCMOS ■ 2.5-V LVTTL/LVCMOS ■ 1.8-V LVTTL/LVCMOS ■ 1.5-V LVCMOS ■ LVDS ■ RSDS ■ mini-LVDS ■ LVPECL (3) ■ SSTL-2 Class I and II ■ SSTL-18 Class I ■ HSTL-18 Class I ■ HSTL-15 Class I ■ Differential SSTL-2 (4) ■ Differential SSTL-18 (4) ■ Differential HSTL-18 (5) ■ Differential HSTL-15 (5) I/O Bank 3 Also Supports the 3.3-V PCI & PCI- X I/O Standards I/O Bank 1 Also Supports the 3.3-V PCI & PCI-X I/O Standards Individual Power Bus I/O Bank 2 Also Supports the SSTL-18 Class II, HSTL-18 Class II, & HSTL-15 Class II I/O Standards I/O Bank 4 Also Supports the SSTL-18 Class II, HSTL-18 Class II, & HSTL-15 Class II I/O Standards
Altera Corporation 2–59 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Figure 2–29. EP2C15, EP2C20, EP2C35, EP2C50 & EP2C70 I/O Banks Notes (1), (2) Notes to Figure 2–29: (1) This is a top view of the silicon die. (2) This is a graphic representation only. Refer to the pi n list and the Quartus II software for exact pin locations. (3) The LVPECL I/O standard is only su pported on clock input pins. This I/O standard is not supported on output pins. (4) The differential SSTL-18 and SSTL-2 I/O standards are only supported on clock input pins and PLL output clock pins. (5) The differential 1.8-V and 1.5-V HSTL I/O standards are only supported on clock input pins and PLL output clock pins. Each I/O bank has its own VCCIO pins. A single device can support 1.5-V , 1.8-V , 2.5-V , and 3.3-V interfaces; each individual bank can support a different standard with different I/O voltages. Each bank also has dual-purpose VREF pins to support any one of the voltage-referenced I/O Bank 2 Regular I/O Block Bank 8 Regular I/O Block Bank 7 I/O Bank 3 I/O Bank 4 I/O Bank 1 I/O Bank 5 I/O Bank 6 Individual Power Bus All I/O Banks Support ■ 3.3-V LVTTL/LVCMOS ■ 2.5-V LVTTL/LVCMOS ■ 1.8-V LVTTL/LVCMOS ■ 1.5-V LVCMOS ■ LVDS ■ RSDS ■ mini-LVDS ■ LVPECL (3) ■ SSTL-2 Class I and II ■ SSTL-18 Class I ■ HSTL-18 Class I ■ HSTL-15 Class I ■ Differential SSTL-2 (4) ■ Differential SSTL-18 (4) ■ Differential HSTL-18 (5) ■ Differential HSTL-15 (5) I/O Banks 3 & 4 Also Support the SSTL-18 Class II, HSTL-18 Class II, & HSTL-15 Class II I/O Standards I/O Banks 7 & 8 Also Support the SSTL-18 Class II, HSTL-18 Class II, & HSTL-15 Class II I/O Standards I/O Banks 5 & 6 Also Support the 3.3-V PCI & PCI-X I/O Standard s I/O Banks 1 & 2 Also Support the 3.3-V PCI & PCI-X I/O Standards
2–60 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 I/O Structure & Features standards (e.g., SSTL-2) independently. If an I/O bank does not use voltage-referenced standards, the VREF pins are available as user I/O pins. Each I/O bank can support multiple standards with the same VCCIO for input and output pins. For example, when VCCIO is 3.3-V , a bank can support LVTTL, LVCMOS, and 3.3-V PCI for inputs and outputs. Voltage-referenced standards can be supported in an I/O bank using any number of single-ended or differential standards as long as they use the same V REF and a compatible VCCIO value. MultiVolt I/O Interface The Cyclone II architecture supports the MultiVolt I/O interface feature, which allows Cyclone II devices in all packages to interface with systems of different supply voltages. Cyclone II devices have one set of VCC pins (VCCINT) that power the internal device logic array and input buffers that use the LVPECL, LVDS, HSTL, or SSTL I/O standards. Cyclone II devices also have four or eight sets of VCC pins (VCCIO) that power the I/O output drivers and input buffers that use the LVTTL, LVCMOS, or PCI I/O standards. The Cyclone II VCCINT pins must always be connected to a 1.2-V power and 3.3-V tolerant. The VCCIO pins can be connected to either a 1.5-V , 1.8-V , 2.5-V , or 3.3-V power supply, depending on the output requirements. The output levels are compatible with systems of the same voltage as the power supply (i.e., when VCCIO pins are connected to a 1.5-V power supply, the output levels are compatible with 1.5-V systems). When VCCIO pins are connected to a 3.3-V power supply, the output high is 3.3-V and is compatible with 3.3-V systems. Table 2–20 summarizes Cyclone II MultiVolt I/O support. Table 2–20. Cyclone II MultiVolt I/O Support (Part 1 of 2) Note (1) VCCIO (V) Input Signal Output Signal 1.5 vv v (2) v (2) v 2.5 vv v (5) v (5) v
Altera Corporation 2–61 February 2007 Cyclone II Device Handbook, Volume 1 Cyclone II Architecture Notes to T able 2–20: (1) The PCI clamping diode must be disabled to drive an input with voltages higher than VCCIO. (2) These input values overdrive the input buffer, so the pin le akage current is slightly higher than the default value. To drive inputs higher than VCCIO but less than 4.0 V , disable the PCI clamping diode and turn on Allow voltage overdrive for LVTTL/LVCMOS input pins option in Device setting option in the Quartus II software. (3) When V CCIO = 1.8-V , a Cyclone II device can drive a 1.5-V device with 1.8-V tolerant inputs. (4) When V CCIO = 3.3-V and a 2.5-V input signal feeds an input pin or when VCCIO = 1.8-V and a 1.5-V input signal feeds an input pin, the VCCIO supply current will be slightly larger than expected. The reason for this increase is that the input signal level does not drive to the VCCIO rail, which causes the input buffer to not completely shut off. Table 2–20. Cyclone II MultiVolt I/O Support (Part 2 of 2) Note (1) VCCIO (V) Input Signal Output Signal
2–62 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Document Revision History Document Table 2–21 shows the revision history for this document. Table 2–21. Document Revision History Date & Document Version Changes Made Summary of Changes February 2007 v3.1
- Added document revision history.
- Removed Table 2-1.
- Updated Figure 2–25.
- Added new Note (1) to Table 2–17.
- Added handpara note in “I/O Banks” section.
- Updated Note (2) to Table 2–20.
- Removed Drive Strength Control from Figure 2–25.
- Elaboration of DDR2 and QDRII interfaces supported by I/O bank included. November 2005 v2.1
- Updated Table 2–7.
- Updated Figures 2–11 and 2–12.
- Updated Programmable Drive Strength table.
- Updated Table 2–16.
- Updated Table 2–18.
- Updated Table 2–19. July 2005 v2.0 ● Updated technical content throughout.
- Updated Table 2–16. February 2005 v1.2 Updated figure 2-12. November 2004 v1.1 Updated Table 2–19. June 2004 v1.0 Added document to the Cyclone II Device Handbook.
Altera Corporation 3–1 February 2007 3. Configuration & Testing IEEE Std. 1149.1 (JTAG) Boundary Scan Support All Cyclone® II devices provide JTAG BST circuitry that complies with the IEEE Std. 1149.1. JTAG boundary-scan testing can be performed either before or after, but not during configuration. Cyclone II devices can also use the JTAG port for configuration with the Quartus® II software or hardware using either Jam Files (.jam) or Jam Byte-Code Files (.jbc). Cyclone II devices support IOE I/O standard reconfiguration through the JTAG BST chain. The JTAG chain can update the I/O standard for all input and output pins any time before or during user mode through the CONFIG_IO instruction. You can use this capability for JTAG testing before configuration when some of the Cyclone II pins drive or receive from other devices on the board using voltage-referenced standards. Since the Cyclone II device might not be configured before JTAG testing, the I/O pins may not be configured for appropriate electrical standards for chip-to-chip communication. Programming the I/O standards via JTAG allows you to fully test I/O connections to other devices. f For information on I/O reconfiguration, refer to the MorphIO: An I/O Reconfiguration Solution for Altera Devices White Paper. A device operating in JTAG mode uses four required pins: TDI, TDO, TMS, and TCK. The TCK pin has an internal weak pull-down resister, while the TDI and TMS pins have weak internal pull-up resistors. The TDO output pin and all JTAG input pin voltage is determined by the VCCIO of the bank where it resides. The bank VCCIO selects whether the JTAG inputs are 1.5-, 1.8-, 2.5-, or 3.3-V compatible.
1 Stratix® II, Stratix, Cyclone II and Cyclone devices must be
within the first 8 devices in a JTAG chain. All of these devices have the same JTAG controller. If any of the Stratix II, Stratix, Cyclone II or Cyclone devices are in the 9th of further position, they fail configuration. This does not affect Signal Tap II. CII51003-2.2
3–2 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 IEEE Std. 1149.1 (JTAG) Boundary Scan Support Cyclone II devices also use the JTAG port to monitor the logic operation of the device with the SignalTap® II embedded logic analyzer. Cyclone II devices support the JTAG instructions shown in Table 3–1. Table 3–1. Cyclone II JTAG Instructions (Part 1 of 2) JTAG Instruction Instruction Code Description SAMPLE/PRELOAD 00 0000 0101 Allows a snapshot of signals at the device pins to be captured and examined during normal device operation, and permits an initial data pattern to be output at the device pins. Also used by the SignalTap II embedded logic analyzer. EXTEST (1) 00 0000 1111 Allows the external circuitry and board-level interconnects to be tested by forcing a test pattern at the output pins and capturing test results at the input pins. BYPASS 11 1111 1111 Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data to pass synchronously through selected devices to adjacent devices during normal device operation. USERCODE 00 0000 0111 Selects the 32-bit USERCODE register and places it between the TDI and TDO pins, allowing the USERCODE to be serially shifted out of TDO. IDCODE 00 0000 0110 Selects the IDCODE register and places it between TDI and TDO, allowing the IDCODE to be serially shifted out of TDO. HIGHZ (1) 00 0000 1011 Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data to pass synchronously through selected devices to adjacent devices during normal device operation, while tri-stating all of the I/O pins. CLAMP (1) 00 0000 1010 Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data to pass synchronously through selected devices to adjacent devices during normal device operation while holding I/O pins to a state defined by the data in the boundary-scan register. ICR instructions Used when configuring a Cyclone II device via the JTAG port with a USB Blaster™ , ByteBlaster™ II, MasterBlaster™ or ByteBlasterMV™ download cable, or when using a Jam File or JBC File via an embedded processor. PULSE_NCONFIG 00 0000 0001 Emulates pulsing the nCONFIG pin low to trigger reconfiguration even though the physical pin is unaffected.
Altera Corporation 3–3 February 2007 Cyclone II Device Handbook, Volume 1 Configuration & Testing The Quartus II software has an Auto Usercode feature where you can choose to use the checksum value of a programming file as the JTAG user code. If selected, the checksum is automatically loaded to the USERCODE register. In the Settings dialog box in the Assignments menu, click Device & Pin Options, then General, and then turn on the Auto Usercode option. CONFIG_IO 00 0000 1101 Allows configuration of I/O standards through the JTAG chain for JTAG testing. Can be executed before, after, or during configuration. Stops configuration if executed during configuration. Once issued, the CONFIG_IO instruction holds nSTATUS low to reset the configuration device. nSTATUS is held low until the device is reconfigured. SignalTap II instructions Monitors internal device operation with the SignalTap II embedded logic analyzer. Note to Table 3–1: (1) Bus hold and weak pull-up resistor feat ures override the high-impedance state of HIGHZ, CLAMP, and EXTEST. Table 3–1. Cyclone II JTAG Instructions (Part 2 of 2) JTAG Instruction Instruction Code Description
3–4 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 IEEE Std. 1149.1 (JTAG) Boundary Scan Support The Cyclone II device instruction register length is 10 bits and the USERCODE register length is 32 bits. Tables 3–2 and 3–3 show the boundary-scan register length and device IDCODE information for Cyclone II devices. For more information on the Cyclone II JTAG specifications, refer to the DC Characteristics & Timing Specifications chapter in the Cyclone II Device Handbook, Volume 1. Table 3–2. Cyclone II Boundary-Scan Register Length Device Boundary-Scan Register Length EP2C5 498 EP2C8 597 EP2C15 969 EP2C20 969 EP2C35 1,449 EP2C50 1,374 EP2C70 1,890 Table 3–3. 32-Bit Cyclone II Device IDCODE Device IDCODE (32 Bits) (1) Version (4 Bits) Part Number (16 Bits) Man ufacturer Identity (11 Bits) LSB (1 Bit) (2) EP2C5 0000 0010 0000 1011 0001 000 0110 1110 1 EP2C8 0000 0010 0000 1011 0010 000 0110 1110 1 EP2C15 0000 0010 0000 1011 0011 000 0110 1110 1 EP2C20 0000 0010 0000 1011 0011 000 0110 1110 1 EP2C35 0000 0010 0000 1011 0100 000 0110 1110 1 EP2C50 0000 0010 0000 1011 0101 000 0110 1110 1 EP2C70 0000 0010 0000 1011 0110 000 0110 1110 1 Notes to Tab le 3–3: (1) The most significant bit (MSB) is on the left. (2) The IDCODE’s least significant bit (LSB) is always 1.
Altera Corporation 3–5 February 2007 Cyclone II Device Handbook, Volume 1 Configuration & Testing SignalTap II Embedded Logic Analyzer Cyclone II devices support the SignalTap II embedded logic analyzer, which monitors design operation over a period of time through the IEEE Std. 1149.1 (JTAG) circuitry. You can analyze internal logic at speed without bringing internal signals to the I/O pins. This feature is particularly important for advanced packages, such as FineLine BGA® packages, because it can be difficult to add a connection to a pin during the debugging process after a board is designed and manufactured. f For more information on the SignalTap II, see the Signal Tap chapter of the Quartus II Handbook, Volume 3. Configuration The logic, circuitry, and interconnects in the Cyclone II architecture are configured with CMOS SRAM elements. Altera FPGA devices are reconfigurable and every device is tested with a high coverage production test program so you do not have to perform fault testing and can instead focus on simulation and design verification. Cyclone II devices are configured at system power-up with data stored in an Altera configuration device or provided by a system controller. The Cyclone II device’s optimized interface allows the device to act as controller in an active serial configuration scheme with EPCS serial configuration devices. The serial configuration device can be programmed via SRunner, the ByteBlaster II or USB Blaster download cable, the Altera Programming Unit (APU), or third-party programmers. In addition to EPCS serial configuration devices, Altera offers in-system programmability (ISP)-capable configuration devices that can configure Cyclone II devices via a serial data stream using the Passive serial (PS) configuration mode. The PS interface also enables microprocessors to treat Cyclone II devices as memory and configure them by writing to a virtual memory location, simplifying reconfiguration. After a Cyclone II device has been configured, it can be reconfigured in-circuit by resetting the device and loading new configuration data. Real-time changes can be made during system operation, enabling innovative reconfigurable applications. Operating Modes The Cyclone II architecture uses SRAM configuration elements that require configuration data to be loaded each time the circuit powers up. The process of physically loading the SRAM data into the device is called configuration. During initialization, which occurs immediately after configuration, the device resets registers, enables I/O pins, and begins to operate as a logic device. You can use the 10MHz internal oscillator or the optional CLKUSR pin during the initialization. The 10 MHz internal oscillator is disabled in user mode. Together, the configuration and initialization processes are called command mode. Normal device operation is called user mode.
3–6 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Configuration Schemes SRAM configuration elements allow Cyclone II devices to be reconfigured in-circuit by loading new configuration data into the device. With real-time reconfiguration, the device is forced into command mode with the nCONFIG pin. The configuration process loads different configuration data, reinitializes the device, and resumes user-mode operation. You can perform in-field upgrades by distributing new configuration files within the system or remotely. A built-in weak pull-up resistor pulls all user I/O pins to V CCIO before and during device configuration. The configuration pins support 1.5-V/1.8-V or 2.5-V/3.3-V I/O standards. The voltage level of the configuration output pins is determined by the VCCIO of the bank where the pins reside. The bank VCCIO selects whether the configuration inputs are 1.5-V , 1.8-V , 2.5-V , or 3.3-V compatible. Configuration Schemes You can load the configuration data for a Cyclone II device with one of three configuration schemes (see Table 3–4), chosen on the basis of the target application. You can use a configuration device, intelligent controller, or the JTAG port to configure a Cyclone II device. A low-cost configuration device can automatically configure a Cyclone II device at system power-up. Multiple Cyclone II devices can be configured in any of the three configuration schemes by connecting the configuration enable (nCE) and configuration enable output (nCEO) pins on each device. f For more information on configuration, see the Configuring Cyclone II Devices chapter of the Cyclone II Handbook, Volume 2. Table 3–4. Data Sources for Configuration Configuration Scheme Data Source Active serial (AS) Low-cost serial configuration device Passive serial (PS) Enhanced or EPC2 c onfiguration device, MasterBlaster, ByteBlasterMV, ByteBlaster II or USB Blaster download cable, or serial data source JTAG MasterBlaster, ByteBlasterMV, ByteBl aster II or USB Blaster download cable or a microprocessor with a Jam or JBC file
Altera Corporation 3–7 February 2007 Cyclone II Device Handbook, Volume 1 Configuration & Testing Cyclone II Automated Single Event Upset Detection Cyclone II devices offer on-chip circuitry for automated checking of single event upset (SEU) detection. Some applications that require the device to operate error free at high elevations or in close proximity to earth’s North or South Pole require periodic checks to ensure continued data integrity. The error detection cyclic redundancy code (CRC) feature controlled by the Device & Pin Options dialog box in the Quartus II software uses a 32-bit CRC circuit to ensure data reliability and is one of the best options for mitigating SEU. You can implement the error detection CRC feature with existing circuitry in Cyclone II devices, eliminating the need for external logic. For Cyclone II devices, the CRC is pre-computed by Quartus II software and then sent to the device as part of the POF file header. The CRC_ERROR pin reports a soft error when configuration SRAM data is corrupted, indicating to the user to preform a device reconfiguration. Custom-Built Circuitry Dedicated circuitry in the Cyclone II devices performs error detection automatically. This error detection circuitry in Cyclone II devices constantly checks for errors in the configuration SRAM cells while the device is in user mode. You can monitor one external pin for the error and use it to trigger a re-configuration cycle. You can select the desired time between checks by adjusting a built-in clock divider. Software Interface In the Quartus II software version 4.1 and later, you can turn on the automated error detection CRC feature in the Device & Pin Options dialog box. This dialog box allows you to enable the feature and set the internal frequency of the CRC checker between 400 kHz to 80 MHz. This controls the rate that the CRC circuitry verifies the internal configuration SRAM bits in the FPGA device. f For more information on CRC, refer to AN: 357 Error Detection Using CRC in Altera FPGAs.
3–8 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Document Revision History Document Table 3–5 shows the revision history for this document. Table 3–5. Document Revision History Date & Document Version Changes Made Summary of Changes February 2007 v2.2
- Added document revision history.
- Added new handpara nore in “IEEE Std. 1149.1 (JTAG) Boundary Scan Support” section.
- Updated “Cyclone II Automated Single Event Upset Detection” section.
- Added information about limitation of cascading multi devices in the same JTAG chain.
- Corrected information on CRC calculation. July 2005 v2.0 Updated technical content. February 2005 v1.2 Updated information on JTAG chain limitations. November 2004 v1.1 Updated Table 3–4. June 2004 v1.0 Added document to the Cyclone II Device Handbook.
Altera Corporation 4–1 February 2007 4. Hot Socketing & Power-On Reset Introduction Cyclone® II devices offer hot socketing (also known as hot plug-in, hot insertion, or hot swap) and power sequencing support without the use of any external devices. You can insert or remove a Cyclone II board in a system during system operation without causing undesirable effects to the board or to the running system bus. The hot-socketing feature lessens the board design difficulty when using Cyclone II devices on printed circuit boards (PCBs) that also contain a hot-socketing feature, you no longer need to ensure a proper power-up sequence for each device on the board. The Cyclone II hot-socketing feature provides: ■ Board or device insertion and removal without external components or board manipulation ■ Support for any power-up sequence ■ Non-intrusive I/O buffers to system buses during hot insertion This chapter also discusses the power-on reset (POR) circuitry in Cyclone II devices. The POR circuitry keeps the devices in the reset state until the VCC is within operating range. Cyclone II Hot-Socketing Specifications Cyclone II devices offer hot-socketing capability with all three features listed above without any external components or special design requirements. The hot-socketing feature in Cyclone II devices offers the following: ■ The device can be driven before power-up without any damage to the device itself. ■ I/O pins remain tri-stated during power-up. The device does not drive out before or during power-up, thereby affecting other buses in operation. CII51004-3.1
4–2 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Cyclone II Hot-Socketing Specifications Devices Can Be Driven before Power-Up You can drive signals into the I/O pins, dedicated input pins, and dedicated clock pins of Cyclone II devices before or during power-up or power-down without damaging the device. Cyclone II devices support any power-up or power-down sequence (VCCIO and VCCINT) to simplify system level design. I/O Pins Remain Tri-Stated during Power-Up A device that does not support hot socketing may interrupt system operation or cause contention by driving out before or during power-up. In a hot-socketing situation, the Cyclone II device’s output buffers are turned off during system power-up or power-down. The Cyclone II device also does not drive out until the device is configured and has attained proper operating conditions. The I/O pins are tri-stated until the device enters user mode with a weak pull-up resistor (R) to 3.3V . Refer to Figure 4–1 for more information.
1 You can power up or power down the V
any sequence. The VCCIO and VCCINT must have monotonic rise to their steady state levels. (Refer to Figure 4–3 for more information.) The power supply ramp rates can range from 100 µs to 100 ms for non “A” devices. Both VCC supplies must power down within 100 ms of each other to prevent I/O pins from driving out. During hot socketing, the I/O pin capacitance is less than 15 pF and the clock pin capacitance is less than 20 pF. Cyclone II devices meet the following hot-socketing specification. ■ The hot-socketing DC specification is | IIOPIN | < 300 µA. ■ The hot-socketing AC specification is | IIOPIN | < 8 mA for 10 ns or less. This specification takes into account the pin capacitance but not board trace and external loading capacitance. You must consider additional capacitance for trace, connector, and loading separately. IIOPIN is the current at any user I/O pin on the device. The DC specification applies when all VCC supplies to the device are stable in the powered-up or powered-down conditions. For the AC specification, the peak current duration due to power-up transients is 10 ns or less. A possible concern for semiconductor devices in general regarding hot socketing is the potential for latch-up. Latch-up can occur when electrical subsystems are hot socketed into an active system. During hot socketing, the signal pins may be connected and driven by the active system before
Altera Corporation 4–3 February 2007 Cyclone II Device Handbook, Volume 1 Hot Socketing & Power-On Reset the power supply can provide current to the device’s VCC and ground planes. This condition can lead to latch-up and cause a low-impedance path from VCC to ground within the device. As a result, the device extends a large amount of current, possibly causing electrical damage. Altera has ensured by design of the I/O buffers and hot-socketing circuitry, that Cyclone II devices are immune to latch-up during hot socketing. Hot-Socketing Feature Implementation in Cyclone II Devices The hot-socketing feature turns off the output buffer during power up (either VCCINT or VCCIO supplies) or power down. The hot-socket circuit generates an internal HOTSCKT signal when either VCCINT or VCCIO is below the threshold voltage. Designs cannot use the HOTSCKT signal for other purposes. The HOTSCKT signal cuts off the output buffer to ensure that no DC current (except for weak pull-up leakage current) leaks through the pin. When VCC ramps up slowly, VCC is still relatively low even after the internal POR signal (not available to the FPGA fabric used by customer designs) is released and the configuration is finished. The CONF_DONE, nCEO, and nSTATUS pins fail to respond, as the output buffer cannot drive out because the hot-socketing circuitry keeps the I/O pins tristated at this low VCC voltage. Therefore, the hot-socketing circuit has been removed on these configuration output or bidirectional pins to ensure that they are able to operate during configuration. These pins are expected to drive out during power-up and power-down sequences. Each I/O pin has the circuitry shown in Figure 4–1.
Altera Corporation 4–5 February 2007 Cyclone II Device Handbook, Volume 1 Hot Socketing & Power-On Reset Figure 4–2. Transistor Level Diagram of FPGA Device I/O Buffers Notes to Figure 4–2: (1) This is the logic array signal or the larger of either the VCCIO or VPAD signal. (2) This is the larger of either the V CCIO or VPAD signal. Power-On Reset Circuitry Cyclone II devices contain POR circuitry to keep the device in a reset state until the power supply voltage levels have stabilized during power-up. The POR circuit monitors the VCCINT voltage levels and tri-states all user I/O pins until the VCC reaches the recommended operating levels. In addition, the POR circuitry also monitors the VCCIO level of the two I/O banks that contains configuration pins (I/O banks 1 and 3 for EP2C5 and EP2C8, I/O banks 2 and 6 for EP2C15A, EP2C20, EP2C35, EP2C50, and EP2C70) and tri-states all user I/O pins until the VCC reaches the recommended operating levels. After the Cyclone II device enters user mode, the POR circuit continues to monitor the VCCINT voltage level so that a brown-out condition during user mode can be detected. If the VCCINT voltage sags below the POR trip point during user mode, the POR circuit resets the device. If the VCCIO voltage sags during user mode, the POR circuit does not reset the device. "Wake-up" Time for Cyclone II Devices In some applications, it may be necessary for a device to wake up very quickly in order to begin operation. The Cyclone II device family offers the Fast-On feature to support fast wake-up time applications. Devices that support the Fast-On feature are designated with an “A” in the ordering code and have stricter power up requirements compared to non- A devices. Logic Array Signal (1) (2) VCCIO VPAD n+ n+ n-well n+p+p+ p-well p-substrate
4–6 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Power-On Reset Circuitry For Cyclone II devices, wake-up time consists of power-up, POR, configuration, and initialization. The device must properly go through all four stages to configure correctly and begin operation. You can calculate wake-up time using the following equation: Figure 4–3 illustrates the components of wake up time. Figure 4–3. Cyclone II Wake-Up Time Note to Figure 4–3: (1) V CC ramp must be monotonic. The VCC ramp time and POR time will depend on the device characteristics and the power supply used in your system. The fast-on devices require a maximum VCC ramp time of 2 ms and have a maximum POR time of 12 ms. Configuration time will depend on the configuration mode chosen and the configuration file size. You can calculate configuration time by multiplying the number of bits in the configuration file with the period of the configuration clock. For fast configuration times, you should use Passive Serial (PS) configuration mode with maximum DCLK frequency of 100 MHz. In addition, you can use compression to reduce the configuration file size and speed up the configuration time. The tCD2UM or tCD2UMC parameters will determine the initialization time.
1 For more information on the tCD2UM or tCD2UMC parameters, refer
to the Configuring Cyclone II Devices chapter in the Cyclone II Device Handbook. Wake-Up Time = VCC Ramp Time + POR Time + Configuration Time + Initialization Tim e VCC Ramp Time POR Time Configuration Time Initialization Time VCC Minimum Voltage Time User Mode
Altera Corporation 4–7 February 2007 Cyclone II Device Handbook, Volume 1 Hot Socketing & Power-On Reset If you cannot meet the maximum VCC ramp time requirement, you must use an external component to hold nCONFIG low until the power supplies have reached their minimum recommend operating levels. Otherwise, the device may not properly configure and enter user mode. Conclusion Cyclone II devices are hot socketable and support all power-up and power-down sequences with the one requirement that VCCIO and VCCINT be powered up and down within 100 ms of each other to keep the I/O pins from driving out. Cyclone II devices do not require any external devices for hot socketing and power sequencing. Document Table 4–1 shows the revision history for this document. Table 4–1. Document Revision History Date & Document Version Changes Made Summary of Changes February 2007 v3.1
- Added document revision history.
- Updated “I/O Pins Remain Tri-Stated during Power-Up” section.
- Updated “Power-On Reset Circuitry” section.
- Added footnote to Figure 4–3.
- Specified VCCIO and VCCINT supplies must be GND when "not powered".
- Added clarification about input-tristate behavior.
- Added infomation on VCC monotonic ramp. July 2005 v2.0 Updated technical content throughout. February 2005 v1.1 Removed ESD section. June 2004 v1.0 Added document to the Cyclone II Device Handbook.
4–8 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Document Revision History
Altera Corporation 5–1 February 2008 5. DC Characteristics and Timing Specifications Operating Conditions Cyclone® II devices are offered in commercial, industrial, automotive, and extended temperature grades. Commercial devices are offered in –6 (fastest), –7, and –8 speed grades. All parameter limits are representative of worst-case supply voltage and junction temperature conditions. Unless otherwise noted, the parameter values in this chapter apply to all Cyclone II devices. AC and DC characteristics are specified using the same numbers for commercial, industrial, and automotive grades. All parameters representing voltages are measured with respect to ground. Tables 5–1 through 5–4 provide information on absolute maximum ratings. Table 5–1. Cyclone II Device Absolute Maximum Ratings Notes (1), (2) Symbol Parameter Conditions Minimum Maximum Unit VCCINT Supply voltage With respect to ground –0.5 1.8 V VCCIO Output supply voltage –0.5 4.6 V VCCA_PLL [1..4] PLL supply voltage –0.5 1.8 V VIN DC input voltage (3) — –0.5 4.6 V IOUT DC output current, per pin — –25 40 mA TSTG Storage temperature No bias –65 150 °C TJ Junction temperature BGA packages under bias — 125 °C Notes to Tab le 5–1: (1) Conditions beyond those listed in this table cause pe rmanent damage to a device. These are stress ratings only. Functional operation at these levels or any other conditions beyond those specified in this chapter is not implied. Additionally, device operation at the absolute maximum ratings for extended periods of time may have adverse effect on the device reliability. (2) Refer to the Operating Requirements for Altera Devices Data Sheet for more information. (3) During transitions, the inputs may overshoot to the voltage shown in Table 5–4 based upon the input duty cycle. The DC case is equivalent to 100% duty cycle. During transition, the inputs may undershoot to –2.0 V for input currents less than 100 mA and periods shorter than 20 ns. CII51005-4.0
5–2 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Operating Conditions Table 5–2 specifies the recommended operating conditions for Cyclone II devices. It shows the allowed voltage ranges for VCCINT, VCCIO, and the operating junction temperature (TJ). The LVTTL and LVCMOS inputs are powered by VCCIO only. The LVDS and LVPECL input buffers on dedicated clock pins are powered by VCCINT. The SSTL, HSTL, LVDS input buffers are powered by both VCCINT and VCCIO. Table 5–2. Recommended Operating Conditions Symbol Parameter Conditions Minimum Maximum Unit VCCINT Supply voltage for internal logic and input buffers (1) 1.15 1.25 V VCCIO (2) Supply voltage for output buffers, 3.3-V operation (3) V Supply voltage for output buffers, 2.5-V operation (1) 2.375 2.625 V Supply voltage for output buffers, 1.8-V operation (1) 1.71 1.89 V Supply voltage for output buffers, 1.5-V operation (1) 1.425 1.575 V TJ Operating junction temperature For commercial use 0 85 °C For industrial use –40 100 °C For extended temperature use –40 125 °C For automotive use –40 125 °C Notes to Tab le 5–2: (1) The V CC must rise monotonically. The maximum VCC (both VCCIO and VCCINT) rise time is 100 ms for non-A devices and 2 ms for A devices. (2) The V CCIO range given here spans the lowest and highest operating voltages of all supported I/O standards. The recommended VCCIO range specific to each of the single-ended I/O standards is given in Table 5–6, and those specific to the differential standards is given in Table 5–8. (3) The minimum and maximum values of 3.0 V and 3.6 V , respectively, for V CCIO only applies to the PCI and PCI-X I/O standards. Refer to Table 5–6 for the voltage range of other I/O standards.
Altera Corporation 5–3 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Table 5–3. DC Characteristics for User I/O, Dual-Purpose, and Dedicated Pins (Part 1 of 2) Symbol Parameter Conditions Minimum Typical Maximum Unit VIN Input voltage (1), (2) –0.5 — 4.0 V Ii Input pin leakage current VIN = VCCIOmax to 0 V (3) –10 — 10 μA VOUT Output voltage — 0 — V CCIO V IOZ Tri-stated I/O pin leakage current VOUT = VCCIOmax to 0 V (3) –10 — 10 μA ICCINT0 VCCINT supply current (standby) VIN = ground, no load, no toggling inputs TJ = 25° C Nominal VCCINT EP2C5/A — 0.010 (4) A EP2C8/A — 0.017 (4) A EP2C15A — 0.037 (4) A EP2C20/A — 0.037 (4) A EP2C35 — 0.066 (4) A EP2C50 — 0.101 (4) A EP2C70 — 0.141 (4) A ICCIO0 VCCIO supply current (standby) VIN = ground, no load, no toggling inputs T J = 25° C VCCIO = 2.5 V EP2C5/A — 0.7 (4) mA EP2C8/A — 0.8 (4) mA EP2C15A — 0.9 (4) mA EP2C20/A — 0.9 (4) mA EP2C35 — 1.3 (4) mA EP2C50 — 1.3 (4) mA EP2C70 — 1.7 (4) mA
5–4 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Operating Conditions Table 5–4 shows the maximum VIN overshoot voltage and the dependency on the duty cycle of the input signal. Refer to Table 5–3 for more information. RCONF (5) (6) Value of I/O pin pull-up resistor before and during configuration V IN = 0 V; VCCIO = 3.3 V 10 25 50 k Ω VIN = 0 V; VCCIO = 2.5 V 15 35 70 k Ω VIN = 0 V; VCCIO = 1.8 V 30 50 100 k Ω VIN = 0 V; VCCIO = 1.5 V 40 75 150 k Ω VIN = 0 V; VCCIO = 1.2 V 50 90 170 k Ω Recommended value of I/O pin external pull-down resistor before and during configuration (7) —1 2 k Ω Notes to Tab le 5–3: (1) All pins, including dedicated inputs, clock, I/O, and JTAG pins, may be driven before VCCINT and VCCIO are powered. (2) The minimum DC input is –0.5 V . Du ring transitions, the inputs may undershoot to –2.0 V or overshoot to the voltages shown in Table 5–4, based on input duty cycle for input currents less than 100 mA. The overshoot is dependent upon duty cycle of the signal. The DC case is equivalent to 100% duty cycle. (3) This value is specified for normal device operation. The value may vary during power-up. This applies for all VCCIO (4) Maximum values depend on the actual T J and design utilization. See the Excel-based PowerPlay Early Power Estimator (www.altera.com) or the Quartus II PowerPlay Power Analyzer feature for maximum values. Refer to “Power Consumption” on page 5–13 for more information. (5) R CONF values are based on characterization. RCONF = VCCIO/IRCONF. RCONF values may be different if VIN value is not 0 V . Pin pull-up resistance values will be lower if an external source drives the pin higher than VCCIO. (6) Minimum condition at –40°C and high V CC, typical condition at 25°C and nominal VCC and maximum condition at 125°C and low VCC for RCONF values. (7) These values apply to all V CCIO settings. Table 5–3. DC Characteristics for User I/O, Dual-Purpose, and Dedicated Pins (Part 2 of 2) Symbol Parameter Conditions Minimum Typical Maximum Unit Table 5–4. VIN Overshoot Voltage for All Input Buffers Maximum VIN (V) Input Signal Duty Cycle 4.0 100% (DC) 4.1 90% 4.2 50% 4.3 30% 4.4 17% 4.5 10%
Altera Corporation 5–5 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Single-Ended I/O Standards Tables 5–6 and 5–7 provide operating condition information when using single-ended I/O standards with Cyclone II devices. Table 5–5 provides descriptions for the voltage and current symbols used in Tables 5–6 and 5–7. Table 5–5. Voltage and Current Symbol Definitions Symbol Definition VCCIO Supply voltage for single-ended inputs and for output drivers VREF Reference voltage for setting the input switching threshold VIL Input voltage that indicates a low logic level VIH Input voltage that indicates a high logic level VOL Output voltage that indicates a low logic level VOH Output voltage that indicates a high logic level IOL Output current condition under which VOL is tested IOH Output current condition under which VOH is tested VTT Voltage applied to a resistor termination as specified by HSTL and SSTL standards Table 5–6. Recommended Operating Conditions for User I/O Pins Using Single-Ended I/O Standards Note (1) (Part 1 of 2) I/O Standard VCCIO (V) V REF (V) V IL (V) V IH (V) Min Typ Max Min Typ Max Max Min 3.3-V LVTTL and LVCMOS 2.5-V LVTTL and LVCMOS 1.8-V LVTTL and LVCMOS VREF – 0.35 (AC) VREF + 0.18 (DC) VREF + 0.35 (AC) VREF – 0.35 (AC) VREF + 0.18 (DC) VREF + 0.35 (AC) VREF – 0.25 (AC) VREF + 0.125 (DC) VREF + 0.25 (AC)
5–6 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Operating Conditions VREF – 0.25 (AC) VREF + 0.125 (DC) VREF + 0.25 (AC) 1.8-V HSTL class I VREF – 0.2 (AC) VREF + 0.1 (DC) VREF + 0.2 (AC) 1.8-V HSTL class II VREF – 0.2 (AC) VREF + 0.1 (DC) VREF + 0.2 (AC) 1.5-V HSTL class I VREF – 0.2 (AC) VREF + 0.1 (DC) VREF + 0.2 (AC) 1.5-V HSTL class II VREF – 0.2 (AC) VREF + 0.1 (DC) VREF + 0.2 (AC) Note to Table 5–6: Table 5–7. DC Characteristics of User I/O Pins Using Single-Ended Standards Notes (1), (2) (Part 1 of 2) I/O Standard Test Conditions Voltage Thresholds IOL (mA) I OH (mA) Maximum V OL (V) Minimum V OH (V) 3.3-V LVTTL 4 –4 0.45 2.4 2.5-V LVTTL and LVCMOS 1– 1 0 . 4 2 . 0 1.8-V LVTTL and LVCMOS 2– 2 0 . 4 5 V CCIO – 0.45 1.5-V LVTTL and LVCMOS 2– 2 0 . 2 5 × V CCIO 0.75 × VCCIO PCI and PCI-X 1.5 –0.5 0.1 × V CCIO 0.9 × VCCIO SSTL-2 class I 8.1 –8.1 V TT – 0.57 V TT + 0.57 SSTL-2 class II 16.4 –16.4 V TT – 0.76 V TT + 0.76 SSTL-18 class I 6.7 –6.7 V TT – 0.475 V TT + 0.475 SSTL-18 class II 13.4 –13.4 0.28 V CCIO – 0.28 1.8-V HSTL class I 8 –8 0.4 V CCIO – 0.4 1.8-V HSTL class II 16 –16 0.4 V CCIO – 0.4 Table 5–6. Recommended Operating Conditions for User I/O Pins Using Single-Ended I/O Standards Note (1) (Part 2 of 2) I/O Standard VCCIO (V) V REF (V) V IL (V) V IH (V) Min Typ Max Min Typ Max Max Min
Altera Corporation 5–7 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Differential I/O Standards The RSDS and mini-LVDS I/O standards are only supported on output pins. The LVDS I/O standard is supported on both receiver input pins and transmitter output pins.
1 For more information on how these differential I/O standards
are implemented, refer to the High-Speed Differential Interfaces in Cyclone II Devices chapter of the Cyclone II Device Handbook. Figure 5–1 shows the receiver input waveforms for all differential I/O standards (LVDS, LVPECL, differential 1.5-V HSTL class I and II, differential 1.8-V HSTL class I and II, differential SSTL-2 class I and II, and differential SSTL-18 class I and II). 1.5-V HSTL class I 8 –8 0.4 V CCIO – 0.4 1.5V HSTL class II 16 –16 0.4 V CCIO – 0.4 Notes to Tab le 5–7: (1) The values in this table are ba sed on the conditions listed in Tables 5–2 and 5–6. (2) This specification is supported across all the programmable drive settings available as shown in the Cyclone II Architecture chapter of the Cyclone II Device Handbook. Table 5–7. DC Characteristics of User I/O Pins Using Single-Ended Standards Notes (1), (2) (Part 2 of 2) I/O Standard Test Conditions Voltage Thresholds IOL (mA) I OH (mA) Maximum V OL (V) Minimum V OH (V)
5–8 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Operating Conditions Figure 5–1. Receiver Input Waveforms for Differential I/O Standards Notes to Figure 5–1: (1) V ID is the differential input voltage. VID = |p – n|. (2) V ICM is the input common mode voltage. VICM = (p + n)/2. (3) The p – n waveform is a function of the positive channel (p) and the negative channel (n). Single-Ended Waveform Differential Waveform (Mathematical Function of Positive and Negative Channel) Positive Channel (p) = VIH Negative Channel (n) = VIL Ground VID (1) VID (1) VID (1) VICM (2) 0 V p − n (3)
Altera Corporation 5–9 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Table 5–8 shows the recommended operating conditions for user I/O pins with differential I/O standards. Table 5–8. Recommended Operating Conditions for User I/O Pins Using Differential Signal I/O Standards I/O Standard VCCIO (V) V ID (V) (1) VICM (V) V IL (V) V IH (V) Min Typ Max Min Typ Max Min Typ Max Min Max Min Max Mini-LVDS (2) LVPECL (3) (6) Differential 1.5-V HSTL class I and II (4) 1.425 1.5 1.575 0.2 — V CCIO + 0.6 0.68 — 0.9 — V REF – 0.20 VREF + 0.20 Differential 1.8-V HSTL class I and II (4) REF – 0.20 VREF + 0.20 Differential SSTL-2 class I and II (5) 2.375 2.5 2.625 0.36 — V CCIO + 0.6 0.5 × VCCIO – 0.2 0.5 × VCCIO 0.5 × VCCIO + 0.2 —V REF – 0.35 VREF + 0.35 Differential SSTL-18 class I and II (5) 1.7 1.8 1.9 0.25 — V CCIO + 0.6 0.5 × VCCIO – 0.2 0.5 × VCCIO 0.5 × VCCIO + 0.2 —V REF – 0.25 VREF + 0.25 Notes to Tab le 5–8: (1) Refer to the High-Speed Differential Interfaces in Cyclone II Devices chapter of the Cyclone II Device Handbook for measurement conditions on VID. (2) The RSDS and mini-LVDS I/O standard s are only supported on output pins. (3) The LVPECL I/O standard is only supported on clock in put pins. This I/O standard is not supported on output pins. (4) The differential 1.8-V and 1.5-V HSTL I/O standards are only supported on clock input pins and PLL output clock pins. (5) The differential SSTL-18 and SSTL-2 I/O standards are only supported on clock input pins and PLL output clock pins. (6) The LVPECL clock inputs are powered by V CCINT and support all VCCIO settings. However, it is recommended to connect VCCIO to typical value of 3.3V .
Altera Corporation 5–11 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications DC Characteristics for Different Pin Types Table 5–10 shows the types of pins that support bus hold circuitry. Differential 1.8-V HSTL class I and II (3) CCIO – 0.4 ——0 . 4 Differential SSTL-2 class I (4) 0.57 —— V TT – 0.57 Differential SSTL-2 class II (4) 0.76 —— V TT – 0.76 Differential SSTL-18 class I (4) V CCIO 0.125 0.5 × VCCIO 0.5 × VCCIO 0.125 VTT + 0.475 —— V TT – 0.475 Differential SSTL-18 class II (4) V CCIO 0.125 0.5 × VCCIO 0.5 × VCCIO 0.125 VCCIO – 0.28 — — 0.28 Notes to Tab le 5–9: (1) The LVPECL I/O standard is only supported on clock in put pins. This I/O standard is not supported on output pins. (2) The RSDS and mini-LVDS I/O standard s are only supported on output pins. (3) The differential 1.8-V HSTL and differential 1.5-V HSTL I/O standards are only supported on clock input pins and PLL output clock pins. (4) The differential SSTL-18 and SSTL-2 I/O standards are only supported on clock input pins and PLL output clock pins. Table 5–9. DC Characteristics for User I/O Pins Using Differential I/O Standards Note (1) (Part 2 of 2) I/O Standard VOD (mV) ΔVOD (mV) V OCM (V) V OH (V) V OL (V) Min Typ Max Min Max Min Typ Max Min Max Min Max Table 5–10. Bus Hold Support Pin Type Bus Hold I/O pins using single-ended I/O standards Y es I/O pins using differential I/O standards No Dedicated clock pins No JTAG No Configuration pins No
5–12 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 DC Characteristics for Different Pin Types Table 5–11 specifies the bus hold parameters for general I/O pins. On-Chip Termination Specifications Table 5–12 defines the specifications for internal termination resistance tolerance when using series or differential on-chip termination. Table 5–11. Bus Hold Parameters Note (1) Parameter Conditions VCCIO Level Unit1.8 V 2.5 V 3.3 V Min Max Min Max Min Max Bus-hold low, sustaining current VIN > VIL (maximum) 30 — 50 — 70 — μA Bus-hold high, sustaining current VIN < VIL (minimum) Bus-hold low, overdrive current
0 V < VIN < VCCIO — 200 — 300 — 500 μA
Bus-hold high, overdrive current
0 V < VIN < VCCIO — –200 — –300 — –500 μA
Notes to Tab le 5–11: (1) There is no specification for bus-hold at V CCIO = 1.5 V for the HSTL I/O standard. (2) The bus-hold trip points are based on calc ulated input voltages from the JEDEC standard. Table 5–12. Series On-Chip Termination Specifications Symbol Description Conditions Resistance Tolerance Commercial Max Industrial Max Extended/ Automotive Temp Max Unit 25-Ω RS Internal series termination without calibration (25-Ω setting) VCCIO = 3.3V ±30 ±30 ±40 % 50-Ω RS Internal series termination without calibration (50-Ω setting) VCCIO = 2.5V ±30 ±30 ±40 % 50-Ω RS Internal series termination without calibration (50-Ω setting) Note to Table 5–12: (1) For commercial –8 devices, the tolerance is ±40%.
Altera Corporation 5–13 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Table 5–13 shows the Cyclone II device pin capacitance for different I/O pin types. Power Consumption You can calculate the power usage for your design using the PowerPlay Early Power Estimator and the PowerPlay Power Analyzer feature in the Quartus® II software. The interactive PowerPlay Early Power Estimator is typically used during the early stages of FPGA design, prior to finalizing the project, to get a magnitude estimate of the device power. The Quartus II software PowerPlay Power Analyzer feature is typically used during the later stages of FPGA design. The PowerPlay Power Analyzer also allows you to apply test vectors against your design for more accurate power consumption modeling. In both cases, only use these calculations as an estimation of power, not as a specification. For more information on PowerPlay tools, refer to the PowerPlay Early Power Estimator User Guide and the Power Estimation and Analysis section in volume 3 of the Quartus II Handbook.
1 You can obtain the Excel-based PowerPlay Early Power
Estimator at www.altera.com. Refer to Table 5–3 on page 5–3 for typical ICC standby specifications. The power-up current required by Cyclone II devices does not exceed the maximum static current. The rate at which the current increases is a function of the system power supply. The exact amount of current consumed varies according to the process, temperature, and power ramp rate. The duration of the I CCINT power-up requirement depends on the VCCINT voltage supply rise time. Table 5–13. Device Capacitance Note (1) Symbol Parameter Typical Unit CIO Input capacitance for user I/O pin. 6 pF CLVDS Input capacitance for dual-purpose LVDS/user I/O pin. 6 pF CVREF Input capacitance for dual-purpose VREF pin when used as VREF or user I/O pin. 21 pF CCLK Input capacitance for clock pin. 5 pF Note to T able 5–13: (1) Capacitance is sample-tested only. Ca pacitance is measured using time-domain reflectometry (TDR). Measurement accuracy is within ±0.5 pF.
5–14 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications You should select power supplies and regulators that can supply the amount of current required when designing with Cyclone II devices. Altera recommends using the Cyclone II PowerPlay Early Power Estimator to estimate the user-mode ICCINT consumption and then select power supplies or regulators based on the values obtained. Timing Specifications The DirectDrive™ technology and MultiTrack™ interconnect ensure predictable performance, accurate simulation, and accurate timing analysis across all Cyclone II device densities and speed grades. This section describes and specifies the performance, internal, external, high-speed I/O, JTAG, and PLL timing specifications. This section shows the timing models for Cyclone II devices. Commercial devices meet this timing over the commercial temperature range. Industrial devices meet this timing over the industrial temperature range. Automotive devices meet this timing over the automotive temperature range. Extended devices meet this timing over the extended temperature range. All specifications are representative of worst-case supply voltage and junction temperature conditions. Preliminary and Final Timing Specifications Timing models can have either preliminary or final status. The Quartus II software issues an informational message during the design compilation if the timing models are preliminary. Table 5–14 shows the status of the Cyclone II device timing models. Preliminary status means the timing model is subject to change. Initially, timing numbers are created using simulation results, process data, and other known parameters. These tests are used to make the preliminary numbers as close to the actual timing parameters as possible.
Altera Corporation 5–15 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Final timing numbers are based on actual device operation and testing. These numbers reflect the actual performance of the device under worst-case voltage and junction temperature conditions. Performance Table 5–15 shows Cyclone II performance for some common designs. All performance values were obtained with Quartus II software compilation of LPM, or MegaCore functions for the FIR and FFT designs. Table 5–14. Cyclone II Device Timing Model Status Device Speed Grade Preliminary Final EP2C5/A Commercial/Industrial — v Automotive v — EP2C8/A Commercial/Industrial — v Automotive v — EP2C15A Commercial/Industrial — v Automotive v — EP2C20/A Commercial/Industrial — v Automotive v — EP2C35 Commercial/Industrial — v EP2C50 Commercial/Industrial — v EP2C70 Commercial/Industrial — v Table 5–15. Cyclone II Performance (Part 1 of 4)
Applications
Resources Used Performance (MHz) LEs M4K Memory Blocks DSP Blocks Speed Grade Speed Grade (6) Speed Grade (7) Speed Grade LE 16-to-1 multiplexer (1) 21 0 0 385.35 313.97 270.85 286.04 32-to-1 multiplexer (1) 38 0 0 294.2 260.75 228.78 191.02 16-bit counter 16 0 0 401.6 349.4 310.65 310.65 64-bit counter 64 0 0 157.15 137.98 126.08 126.27
5–16 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications Memory M4K block Simple dual-port RAM 128 × 36 bit (3), (5) 0 1 0 235.29 194.93 163.13 163.13 True dual-port RAM 128 × 18 bit (3), (5) 0 1 0 235.29 194.93 163.13 163.13 FIFO 128 × 16 bit (5) 32 1 0 235.29 194.93 163.13 163.13 Simple dual-port RAM 128 × 36 bit (4),(5) 0 1 0 210.08 195.0 163.02 163.02 True dual-port RAM 128x18 bit (4),(5) 0 1 0 163.02 163.02 163.02 163.02 DSP block 9 × 9-bit multiplier (2) 0 0 1 260.01 216.73 180.57 180.57 18 × 18-bit multiplier (2) 0 0 1 260.01 216.73 180.57 180.57 18-bit, 4 tap FIR filter 113 0 8 182.74 147.47 127.74 122.98 Larger Designs 8-bit, 16 tap parallel FIR filter 52 0 4 153.56 131.25 110.44 110.57 8-bit, 1024 pt, Streaming,
3 Mults/5 Adders FFT function
3191 22 9 235.07 195.0 147.51 163.02 8-bit, 1024 pt, Streaming,
4 Mults/2 Adders FFT function
3041 22 12 235.07 195.0 146.3 163.02 8-bit, 1024 pt, Single Output,
1 Parallel FFT Engine, Burst,
1056 5 3 235.07 195.0 147.84 163.02 8-bit, 1024 pt, Single Output, 1006 5 4 235.07 195.0 149.99 163.02 8-bit, 1024 pt, Single Output,
2 Parallel FFT Engines, Burst,
1857 10 6 200.0 195.0 149.61 163.02 8-bit, 1024 pt, Single Output, 1757 10 8 200.0 195.0 149.34 163.02 8-bit, 1024 pt, Quad Output, 2550 10 9 235.07 195.0 148.21 163.02 Table 5–15. Cyclone II Performance (Part 2 of 4) Resources Used Performance (MHz) LEs M4K Memory Blocks DSP Blocks Speed Grade Speed Grade (6) Speed Grade (7) Speed Grade
Altera Corporation 5–17 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Larger Designs 8-bit, 1024 pt, Quad Output, 2400 10 12 235.07 195.0 140.11 163.02 8-bit, 1024 pt, Quad Output, 4343 14 18 200.0 195.0 152.67 163.02 8-bit, 1024 pt, Quad Output, 4043 14 24 200.0 195.0 149.72 163.02 8-bit, 1024 pt, Quad Output,
4 Parallel FFT Engines, Burst,
7496 28 36 200.0 195.0 150.01 163.02 8-bit, 1024 pt, Quad Output, 6896 28 48 200.0 195.0 151.33 163.02 8-bit, 1024 pt, Quad Output,
1 Parallel FFT Engine, Buffered
Burst, 2934 18 9 235.07 195.0 148.89 163.02 8-bit, 1024 pt, Quad Output, Burst, 2784 18 12 235.07 195.0 151.51 163.02 8-bit, 1024 pt, Quad Output,
2 Parallel FFT Engines, Buffered
Burst, 4720 30 18 200.0 195.0 149.76 163.02 8-bit, 1024 pt, Quad Output, Burst, 4420 30 24 200.0 195.0 151.08 163.02 Table 5–15. Cyclone II Performance (Part 3 of 4) Resources Used Performance (MHz) LEs M4K Memory Blocks DSP Blocks Speed Grade Speed Grade (6) Speed Grade (7) Speed Grade
5–18 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications Internal Timing Refer to Tables 5–16 through 5–19 for the internal timing parameters. Larger Designs 8-bit, 1024 pt, Quad Output,
4 Parallel FFT Engines, Buffered
Burst, 3 Mults/5 Adders FFT function 8053 60 36 200.0 195.0 149.23 163.02 8-bit, 1024 pt, Quad Output, Burst, 4 Mults/2 Adders FFT function 7453 60 48 200.0 195.0 151.28 163.02 Notes to T able 5–15 : (1) This application uses regi stered inputs and outputs. (2) This application uses registered multiplier input and output stages within the DSP block. (3) This application uses the same clock source for both A and B ports. (4) This application uses independent clock sources for A and B ports. (5) This application uses PLL clock outputs that are globa lly routed to connect and drive M4K clock ports. Use of non-PLL clock sources or local routing to drive M4K clock ports may result in lower performance numbers than shown here. Refer to the Quartus II timing report for actual performance numbers. (6) These numbers are for commercial devices. (7) These numbers are for automotive devices. Table 5–15. Cyclone II Performance (Part 4 of 4) Resources Used Performance (MHz) LEs M4K Memory Blocks DSP Blocks Speed Grade Speed Grade (6) Speed Grade (7) Speed Grade Table 5–16. LE_FF Internal Timing Microparameters (Part 1 of 2) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max TH 266 — 306 — 306 — ps — — 286 — 306 — ps TCO 141 250 135 277 135 304 ps — — 141 — 141 — ps TCLR 191 — 244 — 244 — ps — — 217 — 244 — ps
Altera Corporation 5–19 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications TPRE 191 — 244 — 244 — ps — — 217 — 244 — ps TCLKL 1000 — 1242 — 1242 — ps — — 1111 — 1242 — ps TCLKH 1000 — 1242 — 1242 — ps — — 1111 — 1242 — ps tLUT 180 438 172 545 172 651 ps — — 180 — 180 — ps Notes to T able 5–16: (1) For the –6 speed grades, the minimum timing is for th e commercial temperature grade. The –7 speed grade devices offer the automotive temperature grade. The –8 speed grade devices offer the industrial temperature grade. (2) For each parameter of the –7 speed grade columns, the value in the first row represents the minimum timing parameter for automotive devices. The second row represents the minimum timing parameter for commercial devices. (3) For each parameter of the –8 speed grade columns, the value in the first row represents the minimum timing parameter for industrial devices. The second row represents the minimum timing parameter for commercial devices. Table 5–17. IOE Internal Timing Microparameters (Part 1 of 2) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max T S U 7 6 —1 0 1—1 0 1— p s — — 89 — 101 — ps TH 88 — 106 — 106 — ps — — 97 — 106 — ps TCO 99 155 95 171 95 187 ps — — 99 — 99 — ps TPIN2COMBOUT_R 384 762 366 784 366 855 ps — —3 8 4—3 8 4— p s TPIN2COMBOUT_C 385 760 367 783 367 854 ps — —3 8 5—3 8 5— p s TCOMBIN2PIN_R 1344 2490 1280 2689 1280 2887 ps — — 1344 — 1344 — ps Table 5–16. LE_FF Internal Timing Microparameters (Part 2 of 2) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max
5–20 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications TCOMBIN2PIN_C 1418 2622 1352 2831 1352 3041 ps — — 1418 — 1418 — ps TCLR 137 — 165 — 165 — ps — —1 5 1—1 6 5— p s TPRE 192 — 233 — 233 — ps — —2 1 2—2 3 3— p s TCLKL 1000 — 1242 — 1242 — ps — — 1111 — 1242 — ps TCLKH 1000 — 1242 — 1242 — ps — — 1111 — 1242 — ps Notes to T able 5–17: (1) For the –6 speed grades, the minimum timing is for th e commercial temperature grade. The –7 speed grade devices offer the automotive temperature grade. The –8 speed grade devices offer the industrial temperature grade. (2) For each parameter of the –7 speed grade columns, the value in the first row represents the minimum timing parameter for automotive devices. The second row represents the minimum timing parameter for commercial devices. (3) For each parameter of the –8 speed grade columns, the value in the first row represents the minimum timing parameter for industrial devices. The second row represents the minimum timing parameter for commercial devices. Table 5–18. DSP Block Internal Timing Microparameters (Part 1 of 2) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max T S U 4 7—6 2—6 2— p s — — 54 — 62 — ps TH 110 — 113 — 113 — ps — — 111 — 113 — ps T C O 000000 p s — —0—0— p s TINREG2PIPE9 652 1379 621 1872 621 2441 ps — — 652 — 652 — ps TINREG2PIPE18 652 1379 621 1872 621 2441 ps — — 652 — 652 — ps Table 5–17. IOE Internal Timing Microparameters (Part 2 of 2) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max
Altera Corporation 5–21 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications TPIPE2OUTREG 47 104 45 142 45 185 ps — — 47 — 47 — ps TPD9 529 2470 505 3353 505 4370 ps — — 529 — 529 — ps TPD18 425 2903 406 3941 406 5136 ps — — 425 — 425 — ps TCLR 2686 — 3572 — 3572 — ps — — 3129 — 3572 — ps TCLKL 1923 — 2769 — 2769 — ps — — 2307 — 2769 — ps TCLKH 1923 — 2769 — 2769 — ps — — 2307 — 2769 — ps Notes to T able 5–18: (1) For the –6 speed grades, the minimum timing is for th e commercial temperature grade. The –7 speed grade devices offer the automotive temperature grade. The –8 speed grade devices offer the industrial temperature grade. (2) For each parameter of the –7 speed grade columns, the value in the first row represents the minimum timing parameter for automotive devices. The second row represents the minimum timing parameter for commercial devices. (3) For each parameter of the –8 speed grade columns, the value in the first row represents the minimum timing parameter for industrial devices. The second row represents the minimum timing parameter for commercial devices. Table 5–19. M4K Block Internal Timing Microparameters (Part 1 of 3) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max TM4KRC 2387 3764 2275 4248 2275 4736 ps — — 2387 — 2387 — ps TM4KWERESU 35 — 46 — 46 — ps ——4 0—4 6— p s TM4KWEREH 234 — 267 — 267 — ps — — 250 — 267 — ps TM4KBESU 35 — 46 — 46 — ps ——4 0—4 6— p s Table 5–18. DSP Block Internal Timing Microparameters (Part 2 of 2) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max
5–22 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications TM4KBEH 234 — 267 — 267 — ps — — 250 — 267 — ps TM4KDATAASU 35 — 46 — 46 — ps ——4 0—4 6— p s TM4KDATAAH 234 — 267 — 267 — ps — — 250 — 267 — ps TM4KADDRASU 35 — 46 — 46 — ps ——4 0—4 6— p s TM4KADDRAH 234 — 267 — 267 — ps — — 250 — 267 — ps TM4KDATABSU 35 — 46 — 46 — ps ——4 0—4 6— p s TM4KDATABH 234 — 267 — 267 — ps — — 250 — 267 — ps TM4KRADDRBSU 35 — 46 — 46 — ps ——4 0—4 6— p s TM4KRADDRBH 234 — 267 — 267 — ps — — 250 — 267 — ps TM4KDATACO1 466 724 445 826 445 930 ps — — 466 — 466 — ps TM4KDATACO2 2345 3680 2234 4157 2234 4636 ps — — 2345 — 2345 — ps TM4KCLKH 1923 — 2769 — 2769 — ps — — 2307 — 2769 — ps TM4KCLKL 1923 — 2769 — 2769 — ps — — 2307 — 2769 — ps Table 5–19. M4K Block Internal Timing Microparameters (Part 2 of 3) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max
Altera Corporation 5–23 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Cyclone II Clock Timing Parameters Refer to Tables 5–20 through 5–34 for Cyclone II clock timing parameters. EP2C5/A Clock Timing Parameters Tables 5–21 and 5–22 show the clock timing parameters for EP2C5/A devices. TM4KCLR 191 — 244 — 244 — ps — — 217 — 244 — ps Notes to T able 5–19: (1) For the –6 speed grades, the minimum timing is for th e commercial temperature grade. The –7 speed grade devices offer the automotive temperature grade. The –8 speed grade devices offer the industrial temperature grade. (2) For each parameter of the –7 speed grade columns, the value in the first row represents the minimum timing parameter for automotive devices. The second row represents the minimum timing parameter for commercial devices. (3) For each parameter of the –8 speed grade columns, the value in the first row represents the minimum timing parameter for industrial devices. The second row represents the minimum timing parameter for commercial devices. Table 5–19. M4K Block Internal Timing Microparameters (Part 3 of 3) Parameter –6 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade (3) Unit Min Max Min Max Min Max Table 5–20. Cyclone II Clock Timing Parameters Symbol Parameter tCIN Delay from clock pad to I/O input register tCOUT Delay from clock pad to I/O output register tPLLCIN Delay from PLL inclk pad to I/O input register tPLLCOUT Delay from PLL inclk pad to I/O output register Table 5–21. EP2C5/A Column Pins Global Clock Timing Parameters (Part 1 of 2) Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial
5–24 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications EP2C8/A Clock Timing Parameters Tables 5–23 and 5–24 show the clock timing parameters for EP2C8/A devices. Notes to T able 5–21: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–22. EP2C5/A Row Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Notes to T able 5–22: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–21. EP2C5/A Column Pins Global Clock Timing Parameters (Part 2 of 2) Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Table 5–23. EP2C8/A Column Pins Global Clock Timing Parameters (Part 1 of 2) Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial
Altera Corporation 5–25 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications EP2C15A Clock Timing Parameters Tables 5–25 and 5–26 show the clock timing parameters for EP2C15A devices. Notes to T able 5–23: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–24. EP2C8/A Row Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Notes to T able 5–24: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–23. EP2C8/A Column Pins Global Clock Timing Parameters (Part 2 of 2) Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Table 5–25. EP2C15A Column Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial
5–26 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications EP2C20/A Clock Timing Parameters Tables 5–27 and 5–28 show the clock timing parameters for EP2C20/A devices. Notes to T able 5–25: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–26. EP2C15A Row Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Notes to T able 5–26: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–25. EP2C15A Column Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Table 5–27. EP2C20/A Column Pins Global Clock Timing Parameters (Part 1 of 2) Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial
Altera Corporation 5–27 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications EP2C35 Clock Timing Parameters Tables 5–29 and 5–30 show the clock timing parameters for EP2C35 devices. Notes to T able 5–27: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–28. EP2C20/A Row Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Notes to T able 5–28: (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–27. EP2C20/A Column Pins Global Clock Timing Parameters (Part 2 of 2) Parameter Fast Corner –6 Speed Grade –7 Speed Grade (1) –7 Speed Grade (2) –8 Speed Grade UnitIndustrial/ Automotive Commercial Table 5–29. EP2C35 Column Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Industrial Commercial
5–28 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications EP2C50 Clock Timing Parameters Tables 5–31 and 5–32 show the clock timing parameters for EP2C50 devices. Table 5–30. EP2C35 Row Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Industrial Commercial Table 5–31. EP2C50 Column Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Industrial Commercial Table 5–32. EP2C50 Row Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Industrial Commercial
Altera Corporation 5–29 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications EP2C70 Clock Timing Parameters Tables 5–33 and 5–34 show the clock timing parameters for EP2C70 devices. Clock Network Skew Adders Table 5–35 shows the clock network specifications. Table 5–33. EP2C70 Column Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Industrial Commercial Table 5–34. EP2C70 Row Pins Global Clock Timing Parameters Parameter Fast Corner –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Industrial Commercial Table 5–35. Clock Network Specifications Name Description Max Unit Clock skew adder EP2C5/A, EP2C8/A (1) Inter-clock network, same bank ±88 ps Inter-clock network, same side and entire chip ±88 ps Clock skew adder EP2C15A, EP2C20/A, EP2C35, EP2C50, EP2C70 (1) Inter-clock network, same bank ±118 ps Inter-clock network, same side and entire chip ±138 ps Note to T able 5–35: (1) This is in addition to intra-clock network skew, which is modeled in the Quartus II software.
5–30 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications IOE Programmable Delay Refer to Table 5–36 and 5–37 for IOE programmable delay. Table 5–36. Cyclone II IOE Programmable Delay on Column Pins Notes (1), (2) Parameter Paths Affected Number of Settings Fast Corner (3) –6 Speed Grade –7 Speed Grade (4) –8 Speed Grade Unit Min Offset Max Offset Min Offset Max Offset Min Offset Max Offset Min Offset Max Offset Input Delay from Pin to Internal Cells Pad -> I/O dataout to core 7 0 2233 0 3827 0 4232 0 4349 ps 0 2344 — — 0 4088 — — ps Input Delay from Pin to Input Register Pad -> I/O input register 8 0 2656 0 4555 0 4914 0 4940 ps 0 2788 — — 0 4748 — — ps Delay from Output Register to Output Pin I/O output register -> Pad 2 0 303 0 563 0 638 0 670 ps 0 318 — — 0 617 — — ps Notes to T able 5–36: (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of the Quartus II software. (2) The minimum and maximum of fset timing numbers are in reference to setting “0” as available in the Quartus II software. (3) The value in the first row for each parameter represe nts the fast corner timing parameter for industrial and automotive devices. The second row represents the fast corner timing parameter for commercial devices. (4) The value in the first row is for automotive de vices. The second row is for commercial devices. Table 5–37. Cyclone II IOE Programmable Delay on Row Pins Notes (1), (2) (Part 1 of 2) Parameter Paths Affected Number of Settings Fast Corner (3) –6 Speed Grade –7 Speed Grade (4) –8 Speed Grade Unit Min Offset Max Offset Min Offset Max Offset Min Offset Max Offset Min Offset Max Offset Input Delay from Pin to Internal Cells Pad -> I/O dataout to core 7 0 2240 0 3776 0 4174 0 4290 ps 0 2352 — — 0 4033 — — ps
Altera Corporation 5–31 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Default Capacitive Loading of Different I/O Standards Refer to Table 5–38 for default capacitive loading of different I/O standards. Input Delay from Pin to Input Register Pad -> I/O input register 8 0 2669 0 4482 0 4834 0 4859 ps 0 2802 — — 0 4671 — — ps Delay from Output Register to Output Pin I/O output register - > Pad 2 0 308 0 572 0 648 0 682 ps 0 324 — — 0 626 — — ps Notes to T able 5–37 : (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of the Quartus II software. (2) The minimum and maximum of fset timing numbers are in reference to setting “0” as available in the Quartus II software. (3) The value in the first row represents the fast corner timing parameter for industrial and automotive devices. The second row represents the fast corner timing parameter for commercial devices. (4) The value in the first row is for automotive de vices. The second row is for commercial devices. Table 5–37. Cyclone II IOE Programmable Delay on Row Pins Notes (1), (2) (Part 2 of 2) Parameter Paths Affected Number of Settings Fast Corner (3) –6 Speed Grade –7 Speed Grade (4) –8 Speed Grade Unit Min Offset Max Offset Min Offset Max Offset Min Offset Max Offset Min Offset Max Offset Table 5–38. Default Loading of Different I/O Standards for Cyclone II Device (Part 1 of 2) I/O Standard Capacitive Load Unit LVTTL 0 pF LVCMOS 0 pF 2.5V 0 pF 1.8V 0 pF 1.5V 0 pF PCI 10 pF PCI-X 10 pF SSTL_2_CLASS_I 0 pF SSTL_2_CLASS_II 0 pF SSTL_18_CLASS_I 0 pF
5–32 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications SSTL_18_CLASS_II 0 pF 1.5V_HSTL_CLASS_I 0 pF 1.5V_HSTL_CLASS_II 0 pF 1.8V_HSTL_CLASS_I 0 pF 1.8V_HSTL_CLASS_II 0 pF DIFFERENTIAL_SSTL_2_CLASS_I 0 pF DIFFERENTIAL_SSTL_2_CLASS_II 0 pF DIFFERENTIAL_SSTL_18_CLASS_I 0 pF DIFFERENTIAL_SSTL_18_CLASS_II 0 pF 1.5V_DIFFERENTIAL_HSTL_CLASS_I 0 pF 1.5V_DIFFERENTIAL_HSTL_CLASS_II 0 pF 1.8V_DIFFERENTIAL_HSTL_CLASS_I 0 pF 1.8V_DIFFERENTIAL_HSTL_CLASS_II 0 pF LVDS 0 pF 1.2V_HSTL 0 pF 1.2V_DIFFERENTIAL_HSTL 0 pF Table 5–38. Default Loading of Different I/O Standards for Cyclone II Device (Part 2 of 2) I/O Standard Capacitive Load Unit
Altera Corporation 5–33 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications I/O Delays Refer to Tables 5–39 through 5–43 for I/O delays. Table 5–39. I/O Delay Parameters Symbol Parameter tDIP Delay from I/O datain to output pad tOP Delay from I/O output register to output pad tPCOUT Delay from input pad to I/O dataout to core tPI Delay from input pad to I/O input register Table 5–40. Cyclone II I/O Input Delay for Column Pins (Part 1 of 3) I/O Standard Parameter Fast Corner –6 Speed Grade Speed Grade (1) Speed Grade (2) Speed Grade UnitIndustrial/ Automotive Commer -cial LVTTL t PI 581 609 1222 1228 1282 1282 ps tPCOUT 367 385 760 783 854 854 ps 2.5V t PI 624 654 1192 1238 1283 1283 ps tPCOUT 410 430 730 793 855 855 ps 1.8V t PI 725 760 1372 1428 1484 1484 ps tPCOUT 511 536 910 983 1056 1056 ps 1.5V t PI 790 828 1439 1497 1556 1556 ps tPCOUT 576 604 977 1052 1128 1128 ps LVCMOS t PI 581 609 1222 1228 1282 1282 ps tPCOUT 367 385 760 783 854 854 ps SSTL_2_CLASS_I t PI 533 558 990 1015 1040 1040 ps tPCOUT 319 334 528 570 612 612 ps SSTL_2_CLASS_II t PI 533 558 990 1015 1040 1040 ps tPCOUT 319 334 528 570 612 612 ps SSTL_18_CLASS_I t PI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps SSTL_18_CLASS_II t PI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps
5–34 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications 1.5V_HSTL_CLASS_I t PI 589 617 1145 1176 1208 1208 ps tPCOUT 375 393 683 731 780 780 ps 1.5V_HSTL_CLASS_II t PI 589 617 1145 1176 1208 1208 ps tPCOUT 375 393 683 731 780 780 ps 1.8V_HSTL_CLASS_I t PI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps 1.8V_HSTL_CLASS_II t PI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps DIFFERENTIAL_SSTL_2_ CLASS_I tPI 533 558 990 1015 1040 1040 ps tPCOUT 319 334 528 570 612 612 ps DIFFERENTIAL_SSTL_2_ CLASS_II tPI 533 558 990 1015 1040 1040 ps tPCOUT 319 334 528 570 612 612 ps DIFFERENTIAL_SSTL_18_ CLASS_I tPI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps DIFFERENTIAL_SSTL_18_ CLASS_II tPI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps 1.8V_DIFFERENTIAL_HSTL_ CLASS_I tPI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps 1.8V_DIFFERENTIAL_HSTL_ CLASS_II tPI 577 605 1027 1035 1045 1045 ps tPCOUT 363 381 565 590 617 617 ps 1.5V_DIFFERENTIAL_HSTL_ CLASS_I tPI 589 617 1145 1176 1208 1208 ps tPCOUT 375 393 683 731 780 780 ps 1.5V_DIFFERENTIAL_HSTL_ CLASS_II tPI 589 617 1145 1176 1208 1208 ps tPCOUT 375 393 683 731 780 780 ps LVDS t PI 623 653 1072 1075 1078 1078 ps tPCOUT 409 429 610 630 650 650 ps 1.2V_HSTL t PI 570 597 1263 1324 1385 1385 ps tPCOUT 356 373 801 879 957 957 ps Table 5–40. Cyclone II I/O Input Delay for Column Pins (Part 2 of 3) I/O Standard Parameter Fast Corner –6 Speed Grade Speed Grade (1) Speed Grade (2) Speed Grade UnitIndustrial/ Automotive Commer -cial
Altera Corporation 5–35 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications 1.2V_DIFFERENTIAL_HSTL t PI 570 597 1263 1324 1385 1385 ps tPCOUT 356 373 801 879 957 957 ps Notes to T able 5–40 : (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–41. Cyclone II I/O Input Delay for Row Pins (Part 1 of 2) I/O Standard Parameter Fast Corner –6 Speed Grade Speed Grade (1) Speed Grade (2) Speed Grade UnitIndustrial/ Automotive Commer -cial LVTTL t PI 583 611 1129 1160 1240 1240 ps tPCOUT 366 384 762 784 855 855 ps 2.5V t PI 629 659 1099 1171 1244 1244 ps tPCOUT 412 432 732 795 859 859 ps 1.8V t PI 729 764 1278 1360 1443 1443 ps tPCOUT 512 537 911 984 1058 1058 ps 1.5V t PI 794 832 1345 1429 1513 1513 ps tPCOUT 577 605 978 1053 1128 1128 ps LVCMOS t PI 583 611 1129 1160 1240 1240 ps tPCOUT 366 384 762 784 855 855 ps SSTL_2_CLASS_I t PI 536 561 896 947 998 998 ps tPCOUT 319 334 529 571 613 613 ps SSTL_2_CLASS_II t PI 536 561 896 947 998 998 ps tPCOUT 319 334 529 571 613 613 ps SSTL_18_CLASS_I t PI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps SSTL_18_CLASS_II t PI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps 1.5V_HSTL_CLASS_I t PI 593 621 1051 1109 1167 1167 ps tPCOUT 376 394 684 733 782 782 ps Table 5–40. Cyclone II I/O Input Delay for Column Pins (Part 3 of 3) I/O Standard Parameter Fast Corner –6 Speed Grade Speed Grade (1) Speed Grade (2) Speed Grade UnitIndustrial/ Automotive Commer -cial
5–36 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications 1.5V_HSTL_CLASS_II t PI 593 621 1051 1109 1167 1167 ps tPCOUT 376 394 684 733 782 782 ps 1.8V_HSTL_CLASS_I t PI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps 1.8V_HSTL_CLASS_II t PI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps DIFFERENTIAL_SSTL_2_ CLASS_I tPI 536 561 896 947 998 998 ps tPCOUT 319 334 529 571 613 613 ps DIFFERENTIAL_SSTL_2_ CLASS_II tPI 536 561 896 947 998 998 ps tPCOUT 319 334 529 571 613 613 ps DIFFERENTIAL_SSTL_18_ CLASS_I tPI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps DIFFERENTIAL_SSTL_18_ CLASS_II tPI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps 1.8V_DIFFERENTIAL_HSTL_ CLASS_I tPI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps 1.8V_DIFFERENTIAL_HSTL_ CLASS_II tPI 581 609 933 967 1004 1004 ps tPCOUT 364 382 566 591 619 619 ps 1.5V_DIFFERENTIAL_HSTL_ CLASS_I tPI 593 621 1051 1109 1167 1167 ps tPCOUT 376 394 684 733 782 782 ps 1.5V_DIFFERENTIAL_HSTL_ CLASS_II tPI 593 621 1051 1109 1167 1167 ps tPCOUT 376 394 684 733 782 782 ps LVDS t PI 651 682 1036 1075 1113 1113 ps tPCOUT 434 455 669 699 728 728 ps PCI t PI 595 623 1113 1156 1232 1232 ps tPCOUT 378 396 746 780 847 847 ps PCI-X t PI 595 623 1113 1156 1232 1232 ps tPCOUT 378 396 746 780 847 847 ps Notes to T able 5–41 : (1) These numbers are for commercial devices. (2) These numbers are for automotive devices. Table 5–41. Cyclone II I/O Input Delay for Row Pins (Part 2 of 2) I/O Standard Parameter Fast Corner –6 Speed Grade Speed Grade (1) Speed Grade (2) Speed Grade UnitIndustrial/ Automotive Commer -cial
Altera Corporation 5–37 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Table 5–42. Cyclone II I/O Output Delay for Column Pins (Part 1 of 6) I/O Standard Drive Strength Parameter Fast Corner –6 Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial/ Automotive Commer -cial LVTTL 4 mA t OP 1524 1599 2903 3125 3341 3348 ps tDIP 1656 1738 3073 3319 3567 3567 ps 8 mA t OP 1343 1409 2670 2866 3054 3061 ps tDIP 1475 1548 2840 3060 3280 3280 ps 12 mA t OP 1287 1350 2547 2735 2917 2924 ps tDIP 1419 1489 2717 2929 3143 3143 ps 16 mA t OP 1239 1299 2478 2665 2844 2851 ps tDIP 1371 1438 2648 2859 3070 3070 ps 20 mA t OP 1228 1288 2456 2641 2820 2827 ps tDIP 1360 1427 2626 2835 3046 3046 ps 24 mA (1) tOP 1220 1279 2452 2637 2815 2822 ps tDIP 1352 1418 2622 2831 3041 3041 ps LVCMOS 4 mA t OP 1346 1412 2509 2695 2873 2880 ps tDIP 1478 1551 2679 2889 3099 3099 ps 8 mA t OP 1240 1300 2473 2660 2840 2847 ps tDIP 1372 1439 2643 2854 3066 3066 ps 12 mA t OP 1221 1280 2428 2613 2790 2797 ps tDIP 1353 1419 2598 2807 3016 3016 ps 16 mA t OP 1203 1262 2403 2587 2765 2772 ps tDIP 1335 1401 2573 2781 2991 2991 ps 20 mA t OP 1194 1252 2378 2562 2738 2745 ps tDIP 1326 1391 2548 2756 2964 2964 ps 24 mA (1) tOP 1192 1250 2382 2566 2742 2749 ps tDIP 1324 1389 2552 2760 2968 2968 ps
5–38 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications 2.5V 4 mA t OP 1208 1267 2478 2614 2743 2750 ps tDIP 1340 1406 2648 2808 2969 2969 ps 8 mA t OP 1190 1248 2307 2434 2554 2561 ps tDIP 1322 1387 2477 2628 2780 2780 ps 12 mA t OP 1154 1210 2192 2314 2430 2437 ps tDIP 1286 1349 2362 2508 2656 2656 ps 16 mA (1) tOP 1140 1195 2152 2263 2375 2382 ps tDIP 1272 1334 2322 2457 2601 2601 ps 1.8V 2 mA t OP 1682 1765 3988 4279 4563 4570 ps tDIP 1814 1904 4158 4473 4789 4789 ps 4 mA t OP 1567 1644 3301 3538 3768 3775 ps tDIP 1699 1783 3471 3732 3994 3994 ps 6 mA t OP 1475 1547 2993 3195 3391 3398 ps tDIP 1607 1686 3163 3389 3617 3617 ps 8 mA t OP 1451 1522 2882 3074 3259 3266 ps tDIP 1583 1661 3052 3268 3485 3485 ps 10 mA t OP 1438 1508 2853 3041 3223 3230 ps tDIP 1570 1647 3023 3235 3449 3449 ps 12 mA (1) tOP 1438 1508 2853 3041 3223 3230 ps tDIP 1570 1647 3023 3235 3449 3449 ps 1.5V 2 mA t OP 2083 2186 4477 4870 5256 5263 ps tDIP 2215 2325 4647 5064 5482 5482 ps 4 mA t OP 1793 1881 3649 3965 4274 4281 ps tDIP 1925 2020 3819 4159 4500 4500 ps 6 mA t OP 1770 1857 3527 3823 4112 4119 ps tDIP 1902 1996 3697 4017 4338 4338 ps 8 mA (1) tOP 1703 1787 3537 3827 4111 4118 ps tDIP 1835 1926 3707 4021 4337 4337 ps Table 5–42. Cyclone II I/O Output Delay for Column Pins (Part 2 of 6) I/O Standard Drive Strength Parameter Fast Corner –6 Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial/ Automotive Commer -cial
Altera Corporation 5–39 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications SSTL_2_ CLASS_I 8 mA t OP 1196 1254 2388 2516 2638 2645 ps tDIP 1328 1393 2558 2710 2864 2864 ps 12 mA (1) tOP 1174 1231 2277 2401 2518 2525 ps tDIP 1306 1370 2447 2595 2744 2744 ps SSTL_2_ CLASS_II 16 mA t OP 1158 1214 2245 2365 2479 2486 ps tDIP 1290 1353 2415 2559 2705 2705 ps 20 mA t OP 1152 1208 2231 2351 2464 2471 ps tDIP 1284 1347 2401 2545 2690 2690 ps 24 mA (1) tOP 1152 1208 2225 2345 2458 2465 ps tDIP 1284 1347 2395 2539 2684 2684 ps SSTL_18_ CLASS_I 6 mA t OP 1472 1544 3140 3345 3542 3549 ps tDIP 1604 1683 3310 3539 3768 3768 ps 8 mA t OP 1469 1541 3086 3287 3482 3489 ps tDIP 1601 1680 3256 3481 3708 3708 ps 10 mA t OP 1466 1538 2980 3171 3354 3361 ps tDIP 1598 1677 3150 3365 3580 3580 ps 12 mA (1) tOP 1466 1538 2980 3171 3354 3361 ps tDIP 1598 1677 3150 3365 3580 3580 ps SSTL_18_ CLASS_II 16 mA t OP 1454 1525 2905 3088 3263 3270 ps tDIP 1586 1664 3075 3282 3489 3489 ps 18 mA (1) tOP 1453 1524 2900 3082 3257 3264 ps tDIP 1585 1663 3070 3276 3483 3483 ps 1.8V_HSTL_ CLASS_I 8 mA t OP 1460 1531 3222 3424 3618 3625 ps tDIP 1592 1670 3392 3618 3844 3844 ps 10 mA t OP 1462 1534 3090 3279 3462 3469 ps tDIP 1594 1673 3260 3473 3688 3688 ps 12 mA (1) tOP 1462 1534 3090 3279 3462 3469 ps tDIP 1594 1673 3260 3473 3688 3688 ps Table 5–42. Cyclone II I/O Output Delay for Column Pins (Part 3 of 6) I/O Standard Drive Strength Parameter Fast Corner –6 Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial/ Automotive Commer -cial
5–40 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications 1.8V_HSTL_ CLASS_II 16 mA t OP 1449 1520 2936 3107 3271 3278 ps tDIP 1581 1659 3106 3301 3497 3497 ps 18 mA t OP 1450 1521 2924 3101 3272 3279 ps tDIP 1582 1660 3094 3295 3498 3498 ps 20 mA (1) tOP 1452 1523 2926 3096 3259 3266 ps tDIP 1584 1662 3096 3290 3485 3485 ps 1.5V_HSTL_ CLASS_I 8 mA t OP 1779 1866 4292 4637 4974 4981 ps tDIP 1911 2005 4462 4831 5200 5200 ps 10 mA t OP 1784 1872 4031 4355 4673 4680 ps tDIP 1916 2011 4201 4549 4899 4899 ps 12 mA (1) tOP 1784 1872 4031 4355 4673 4680 ps tDIP 1916 2011 4201 4549 4899 4899 ps 1.5V_HSTL_ CLASS_II 16 mA (1) tOP 1750 1836 3844 4125 4399 4406 ps tDIP 1882 1975 4014 4319 4625 4625 ps DIFFERENTIAL_ SSTL_2_CLASS_I 8 mA t OP 1196 1254 2388 2516 2638 2645 ps tDIP 1328 1393 2558 2710 2864 2864 ps 12 mA (1) tOP 1174 1231 2277 2401 2518 2525 ps tDIP 1306 1370 2447 2595 2744 2744 ps DIFFERENTIAL_ SSTL_2_CLASS_II 16 mA t OP 1158 1214 2245 2365 2479 2486 ps tDIP 1290 1353 2415 2559 2705 2705 ps 20 mA t OP 1152 1208 2231 2351 2464 2471 ps tDIP 1284 1347 2401 2545 2690 2690 ps 24 mA (1) tOP 1152 1208 2225 2345 2458 2465 ps tDIP 1284 1347 2395 2539 2684 2684 ps Table 5–42. Cyclone II I/O Output Delay for Column Pins (Part 4 of 6) I/O Standard Drive Strength Parameter Fast Corner –6 Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial/ Automotive Commer -cial
Altera Corporation 5–41 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications DIFFERENTIAL_ SSTL_18_CLASS_I 6 mA t OP 1472 1544 3140 3345 3542 3549 ps tDIP 1604 1683 3310 3539 3768 3768 ps 8 mA t OP 1469 1541 3086 3287 3482 3489 ps tDIP 1601 1680 3256 3481 3708 3708 ps 10 mA t OP 1466 1538 2980 3171 3354 3361 ps tDIP 1598 1677 3150 3365 3580 3580 ps 12 mA (1) tOP 1466 1538 2980 3171 3354 3361 ps tDIP 1598 1677 3150 3365 3580 3580 ps DIFFERENTIAL_ SSTL_18_CLASS_II 16 mA t OP 1454 1525 2905 3088 3263 3270 ps tDIP 1586 1664 3075 3282 3489 3489 ps 18 mA (1) tOP 1453 1524 2900 3082 3257 3264 ps tDIP 1585 1663 3070 3276 3483 3483 ps 1.8V_DIFFERENTIAL _HSTL_CLASS_I 8 mA t OP 1460 1531 3222 3424 3618 3625 ps tDIP 1592 1670 3392 3618 3844 3844 ps 10 mA t OP 1462 1534 3090 3279 3462 3469 ps tDIP 1594 1673 3260 3473 3688 3688 ps 12 mA (1) tOP 1462 1534 3090 3279 3462 3469 ps tDIP 1594 1673 3260 3473 3688 3688 ps 1.8V_DIFFERENTIAL _HSTL_CLASS_II 16 mA t OP 1449 1520 2936 3107 3271 3278 ps tDIP 1581 1659 3106 3301 3497 3497 ps 18 mA t OP 1450 1521 2924 3101 3272 3279 ps tDIP 1582 1660 3094 3295 3498 3498 ps 20 mA (1) tOP 1452 1523 2926 3096 3259 3266 ps tDIP 1584 1662 3096 3290 3485 3485 ps 1.5V_DIFFERENTIAL _HSTL_CLASS_I 8 mA t OP 1779 1866 4292 4637 4974 4981 ps tDIP 1911 2005 4462 4831 5200 5200 ps 10 mA t OP 1784 1872 4031 4355 4673 4680 ps tDIP 1916 2011 4201 4549 4899 4899 ps 12 mA (1) tOP 1784 1872 4031 4355 4673 4680 ps tDIP 1916 2011 4201 4549 4899 4899 ps Table 5–42. Cyclone II I/O Output Delay for Column Pins (Part 5 of 6) I/O Standard Drive Strength Parameter Fast Corner –6 Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial/ Automotive Commer -cial
5–42 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications 1.5V_DIFFERENTIAL _HSTL_CLASS_II 16 mA (1) tOP 1750 1836 3844 4125 4399 4406 ps tDIP 1882 1975 4014 4319 4625 4625 ps LVDS — t OP 1258 1319 2243 2344 2438 2445 ps tDIP 1390 1458 2413 2538 2664 2664 ps RSDS — t OP 1258 1319 2243 2344 2438 2445 ps tDIP 1390 1458 2413 2538 2664 2664 ps MINI_LVDS — t OP 1258 1319 2243 2344 2438 2445 ps tDIP 1390 1458 2413 2538 2664 2664 ps SIMPLE_RSDS — t OP 1221 1280 2258 2435 2605 2612 ps tDIP 1353 1419 2428 2629 2831 2831 ps 1.2V_HSTL — t OP 2403 2522 4635 5344 6046 6053 ps tDIP 2535 2661 4805 5538 6272 6272 ps 1.2V_DIFFERENTIAL _HSTL —t OP 2403 2522 4635 5344 6046 6053 ps tDIP 2535 2661 4805 5538 6272 6272 ps Notes to T able 5–42: (1) This is the default setting in the Quartus II software. (2) These numbers are for commercial devices. (3) These numbers are for automotive devices. Table 5–42. Cyclone II I/O Output Delay for Column Pins (Part 6 of 6) I/O Standard Drive Strength Parameter Fast Corner –6 Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial/ Automotive Commer -cial
Altera Corporation 5–43 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Table 5–43. Cyclone II I/O Output Delay for Row Pins (Part 1 of 4) I/O Standard Drive Strength Parameter Fast Corner Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial /Auto- motive Commer- cial LVTTL 4 mA t OP 1343 1408 2539 2694 2885 2891 ps tDIP 1467 1540 2747 2931 3158 3158 ps 8 mA t OP 1198 1256 2411 2587 2756 2762 ps tDIP 1322 1388 2619 2824 3029 3029 ps 12 mA t OP 1156 1212 2282 2452 2614 2620 ps tDIP 1280 1344 2490 2689 2887 2887 ps 16 mA t OP 1124 1178 2286 2455 2618 2624 ps tDIP 1248 1310 2494 2692 2891 2891 ps 20 mA t OP 1112 1165 2245 2413 2574 2580 ps tDIP 1236 1297 2453 2650 2847 2847 ps 24 mA (1) tOP 1105 1158 2253 2422 2583 2589 ps tDIP 1229 1290 2461 2659 2856 2856 ps LVCMOS 4 mA t OP 1200 1258 2231 2396 2555 2561 ps tDIP 1324 1390 2439 2633 2828 2828 ps 8 mA t OP 1125 1179 2260 2429 2591 2597 ps tDIP 1249 1311 2468 2666 2864 2864 ps 12 mA (1) tOP 1106 1159 2217 2383 2543 2549 ps tDIP 1230 1291 2425 2620 2816 2816 ps 2.5V 4 mA t OP 1126 1180 2350 2477 2598 2604 ps tDIP 1250 1312 2558 2714 2871 2871 ps 8 mA (1) tOP 1105 1158 2177 2296 2409 2415 ps tDIP 1229 1290 2385 2533 2682 2682 ps
5–44 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications 1.8V 2 mA t OP 1503 1576 3657 3927 4190 4196 ps tDIP 1627 1708 3865 4164 4463 4463 ps 4 mA t OP 1400 1468 3010 3226 3434 3440 ps tDIP 1524 1600 3218 3463 3707 3707 ps 6 mA t OP 1388 1455 2857 3050 3236 3242 ps tDIP 1512 1587 3065 3287 3509 3509 ps 8 mA t OP 1347 1412 2714 2897 3072 3078 ps tDIP 1471 1544 2922 3134 3345 3345 ps 10 mA t OP 1347 1412 2714 2897 3072 3078 ps tDIP 1471 1544 2922 3134 3345 3345 ps 12 mA (1) tOP 1332 1396 2678 2856 3028 3034 ps tDIP 1456 1528 2886 3093 3301 3301 ps 1.5V 2 mA t OP 1853 1943 4127 4492 4849 4855 ps tDIP 1977 2075 4335 4729 5122 5122 ps 4 mA t OP 1694 1776 3452 3747 4036 4042 ps tDIP 1818 1908 3660 3984 4309 4309 ps 6 mA (1) tOP 1694 1776 3452 3747 4036 4042 ps tDIP 1818 1908 3660 3984 4309 4309 ps SSTL_2_ CLASS_I 8 mA t OP 1090 1142 2152 2268 2376 2382 ps tDIP 1214 1274 2360 2505 2649 2649 ps 12 mA (1) tOP 1097 1150 2131 2246 2354 2360 ps tDIP 1221 1282 2339 2483 2627 2627 ps SSTL_2_ CLASS_II 16 mA (1) tOP 1068 1119 2067 2177 2281 2287 ps tDIP 1192 1251 2275 2414 2554 2554 ps SSTL_18_ CLASS_I 6 mA t OP 1371 1437 2828 3018 3200 3206 ps tDIP 1495 1569 3036 3255 3473 3473 ps 8 mA t OP 1365 1431 2832 3024 3209 3215 ps tDIP 1489 1563 3040 3261 3482 3482 ps 10 mA (1) tOP 1374 1440 2806 2990 3167 3173 ps tDIP 1498 1572 3014 3227 3440 3440 ps Table 5–43. Cyclone II I/O Output Delay for Row Pins (Part 2 of 4) I/O Standard Drive Strength Parameter Fast Corner Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial /Auto- motive Commer- cial
Altera Corporation 5–45 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications 1.8V_HSTL_ CLASS_I 8 mA t OP 1364 1430 2853 3017 3178 3184 ps tDIP 1488 1562 3061 3254 3451 3451 ps 10 mA t OP 1332 1396 2842 3011 3173 3179 ps tDIP 1456 1528 3050 3248 3446 3446 ps 12 mA (1) tOP 1332 1396 2842 3011 3173 3179 ps tDIP 1456 1528 3050 3248 3446 3446 ps 1.5V_HSTL_ CLASS_I 8 mA (1) tOP 1657 1738 3642 3917 4185 4191 ps tDIP 1781 1870 3850 4154 4458 4458 ps DIFFERENTIAL_ SSTL_2_ CLASS_I 8 mA t OP 1090 1142 2152 2268 2376 2382 ps tDIP 1214 1274 2360 2505 2649 2649 ps 12 mA (1) tOP 1097 1150 2131 2246 2354 2360 ps tDIP 1221 1282 2339 2483 2627 2627 ps DIFFERENTIAL_ SSTL_2_ CLASS_II 16 mA (1) t OP 1068 1119 2067 2177 2281 2287 ps tDIP 1192 1251 2275 2414 2554 2554 ps DIFFERENTIAL_ SSTL_18_ CLASS_I 6 mA t OP 1371 1437 2828 3018 3200 3206 ps tDIP 1495 1569 3036 3255 3473 3473 ps 8 mA t OP 1365 1431 2832 3024 3209 3215 ps tDIP 1489 1563 3040 3261 3482 3482 ps 10 mA (1) tOP 1374 1440 2806 2990 3167 3173 ps tDIP 1498 1572 3014 3227 3440 3440 ps 1.8V_ DIFFERENTIAL_ HSTL_ CLASS_I 8 mA t OP 1364 1430 2853 3017 3178 3184 ps tDIP 1488 1562 3061 3254 3451 3451 ps 10 mA t OP 1332 1396 2842 3011 3173 3179 ps tDIP 1456 1528 3050 3248 3446 3446 ps 12 mA (1) tOP 1332 1396 2842 3011 3173 3179 ps tDIP 1456 1528 3050 3248 3446 3446 ps 1.5V_ DIFFERENTIAL_ HSTL_ CLASS_I 8 mA (1) tOP 1657 1738 3642 3917 4185 4191 ps tDIP 1781 1870 3850 4154 4458 4458 ps Table 5–43. Cyclone II I/O Output Delay for Row Pins (Part 3 of 4) I/O Standard Drive Strength Parameter Fast Corner Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial /Auto- motive Commer- cial
5–46 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications Maximum Input and Output Clock Rate Maximum clock toggle rate is defined as the maximum frequency achievable for a clock type signal at an I/O pin. The I/O pin can be a regular I/O pin or a dedicated clock I/O pin. The maximum clock toggle rate is different from the maximum data bit rate. If the maximum clock toggle rate on a regular I/O pin is 300 MHz, the maximum data bit rate for dual data rate (DDR) could be potentially as high as 600 Mbps on the same I/O pin. Table 5–44 specifies the maximum input clock toggle rates. Table 5–45 specifies the maximum output clock toggle rates at default load. Table 5–46 specifies the derating factors for the output clock toggle rate for non-default load. To calculate the output toggle rate for a non-default load, use this formula: The toggle rate for a non-default load LVDS — t OP 1216 1275 2089 2184 2272 2278 ps tDIP 1340 1407 2297 2421 2545 2545 ps RSDS — t OP 1216 1275 2089 2184 2272 2278 ps tDIP 1340 1407 2297 2421 2545 2545 ps MINI_LVDS — t OP 1216 1275 2089 2184 2272 2278 ps tDIP 1340 1407 2297 2421 2545 2545 ps PCI — t OP 989 1036 2070 2214 2352 2358 ps tDIP 1113 1168 2278 2451 2625 2625 ps PCI-X — t OP 989 1036 2070 2214 2352 2358 ps tDIP 1113 1168 2278 2451 2625 2625 ps Notes to T able 5–43: (1) This is the default setting in the Quartus II software. (2) These numbers are for commercial devices. (3) These numbers are for automotive devices. Table 5–43. Cyclone II I/O Output Delay for Row Pins (Part 4 of 4) I/O Standard Drive Strength Parameter Fast Corner Speed Grade Speed Grade (2) Speed Grade (3) Speed Grade UnitIndustrial /Auto- motive Commer- cial
Altera Corporation 5–47 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications = 1000 / (1000/toggle rate at default load + derating factor * load value in pF/1000) For example, the output toggle rate at 0 pF (default) load for SSTL-18 Class II 18mA I/O standard is 270 MHz on a –6 device column I/O pin. The derating factor is 29 ps/pF. For a 10pF load, the toggle rate is calculated as: 1000 / (1000/270 + 29 × 10/1000) = 250 (MHz) Tables 5–44 through 5–46 show the I/O toggle rates for Cyclone II devices. Table 5–44. Maximum Input Clock Toggle Rate on Cyclone II Devices (Part 1 of 2) I/O Standard Maximum Input Clock Toggle Rate on Cyclone II Devices (MHz) Column I/O Pins Row I/O Pins Dedicated Clock Inputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade LVTTL 450 405 360 450 405 360 420 380 340 2.5V 450 405 360 450 405 360 450 405 360 1.8V 450 405 360 450 405 360 450 405 360 1.5V 300 270 240 300 270 240 300 270 240 LVCMOS 450 405 360 450 405 360 420 380 340 SSTL_2_CLASS_I 500 500 500 500 500 500 500 500 500 SSTL_2_CLASS_II 500 500 500 500 500 500 500 500 500 SSTL_18_CLASS_I 500 500 500 500 500 500 500 500 500 SSTL_18_CLASS_II 500 500 500 500 500 500 500 500 500 1.5V_HSTL_CLASS_I 500 500 500 500 500 500 500 500 500 1.5V_HSTL_CLASS_II 500 500 500 500 500 500 500 500 500 1.8V_HSTL_CLASS_I 500 500 500 500 500 500 500 500 500 1.8V_HSTL_CLASS_II 500 500 500 500 500 500 500 500 500 PCI — — — 350 315 280 350 315 280 PCI-X — — — 350 315 280 350 315 280 DIFFERENTIAL_SSTL_2_ CLASS_I 500 500 500 500 500 500 500 500 500 DIFFERENTIAL_SSTL_2_ CLASS_II 500 500 500 500 500 500 500 500 500
5–48 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications DIFFERENTIAL_SSTL_18_ CLASS_I 500 500 500 500 500 500 500 500 500 DIFFERENTIAL_SSTL_18_ CLASS_II 500 500 500 500 500 500 500 500 500 1.8V_DIFFERENTIAL_HSTL_ CLASS_I 500 500 500 500 500 500 500 500 500 1.8V_DIFFERENTIAL_HSTL_ CLASS_II 500 500 500 500 500 500 500 500 500 1.5V_DIFFERENTIAL_HSTL_ CLASS_I 500 500 500 500 500 500 500 500 500 1.5V_DIFFERENTIAL_HSTL_ CLASS_II 500 500 500 500 500 500 500 500 500 LVPECL — — — — — — 402 402 402 LVDS 402 402 402 402 402 402 402 402 402 1.2V_HSTL 110 90 80 — — — 110 90 80 1.2V_DIFFERENTIAL_HSTL 110 90 80 — — — 110 90 80 Table 5–45. Maximum Output Clock Toggle Rate on Cyclone II Devices (Part 1 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate on Cyclone II Devices (MHz) Column I/O Pins (1) Row I/O Pins (1) Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade LVTTL 4 mA 120 100 80 120 100 80 120 100 80 8 mA 200 170 140 200 170 140 200 170 140 12 mA 280 230 190 280 230 190 280 230 190 16 mA 290 240 200 290 240 200 290 240 200 20 mA 330 280 230 330 280 230 330 280 230 24 mA 360 300 250 360 300 250 360 300 250 Table 5–44. Maximum Input Clock Toggle Rate on Cyclone II Devices (Part 2 of 2) I/O Standard Maximum Input Clock Toggle Rate on Cyclone II Devices (MHz) Column I/O Pins Row I/O Pins Dedicated Clock Inputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade
Altera Corporation 5–49 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications LVCMOS 4 mA 250 210 170 250 210 170 250 210 170 8 mA 280 230 190 280 230 190 280 230 190 12 mA 310 260 210 310 260 210 310 260 210 1 6 m A 3 2 0 2 7 0 2 2 0 —————— 2 0 m A 3 5 0 2 9 0 2 4 0 —————— 2 4 m A 3 7 0 3 1 0 2 5 0 —————— 2.5V 4 mA 180 150 120 180 150 120 180 150 120 8 mA 280 230 190 280 230 190 280 230 190 1 2 m A 4 4 0 3 7 0 3 0 0 —————— 1 6 m A 4 5 0 4 0 5 3 5 0 —————— 1.8V 2 mA 120 100 80 120 100 80 120 100 80 4 mA 180 150 120 180 150 120 180 150 120 6 mA 220 180 150 220 180 150 220 180 150 8 mA 240 200 160 240 200 160 240 200 160 10 mA 300 250 210 300 250 210 300 250 210 12 mA 350 290 240 350 290 240 350 290 240 1.5V 2 mA 80 60 50 80 60 50 80 60 50 4 mA 130 110 90 130 110 90 130 110 90 6 mA 180 150 120 180 150 120 180 150 120 8 m A 2 3 0 1 9 0 1 6 0 —————— SSTL_2_CLASS_I 8 mA 400 340 280 400 340 280 400 340 280 12 mA 400 340 280 400 340 280 400 340 280 SSTL_2_CLASS_II 16 mA 350 290 240 350 290 240 350 290 240 2 0 m A 4 0 0 3 4 0 2 8 0 —————— 2 4 m A 4 0 0 3 4 0 2 8 0 —————— SSTL_18_ CLASS_I 6 mA 260 220 180 260 220 180 260 220 180 8 mA 260 220 180 260 220 180 260 220 180 10 mA 270 220 180 270 220 180 270 220 180 1 2 m A 2 8 0 2 3 0 1 9 0 —————— Table 5–45. Maximum Output Clock Toggle Rate on Cyclone II Devices (Part 2 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate on Cyclone II Devices (MHz) Column I/O Pins (1) Row I/O Pins (1) Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade
5–50 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications 1 8 m A 2 7 0 2 2 0 1 8 0 —————— 1.8V_HSTL_ CLASS_I 8 mA 260 220 180 260 220 180 260 220 180 10 mA 300 250 210 300 250 210 300 250 210 12 mA 320 270 220 320 270 220 320 270 220 1.8V_HSTL_ CLASS_II 16 mA 230 190 160 — — ———— 1 8 m A 2 4 0 2 0 0 1 6 0 —————— 2 0 m A 2 5 0 2 1 0 1 7 0 —————— 1.5V_HSTL_ CLASS_I 8 mA 210 170 140 210 170 140 210 170 140 1 0 m A 2 2 0 1 8 0 1 5 0 —————— 1 2 m A 2 3 0 1 9 0 1 6 0 —————— 1.5V_HSTL_ CLASS_II 16 mA 210 170 140 — — ———— DIFFERENTIAL_ SSTL_2_CLASS_I 8 mA 400 340 280 400 340 280 400 340 280 12 mA 400 340 280 400 340 280 400 340 280 DIFFERENTIAL_ SSTL_2_CLASS_II 16 mA 350 290 240 350 290 240 350 290 240 2 0 m A 4 0 0 3 4 0 2 8 0 —————— 2 4 m A 4 0 0 3 4 0 2 8 0 —————— DIFFERENTIAL_ SSTL_18_CLASS_I 6 mA 260 220 180 260 220 180 260 220 180 8 mA 260 220 180 260 220 180 260 220 180 10 mA 270 220 180 270 220 180 270 220 180 1 2 m A 2 8 0 2 3 0 1 9 0 —————— DIFFERENTIAL_SSTL _18_CLASS_II 1 6 m A 2 6 0 2 2 0 1 8 0 —————— 1 8 m A 2 7 0 2 2 0 1 8 0 —————— 1.8V_ DIFFERENTIAL_HSTL _CLASS_I 8 mA 260 220 180 260 220 180 260 220 180 10 mA 300 250 210 300 250 210 300 250 210 12 mA 320 270 220 320 270 220 320 270 220 1.8V_ DIFFERENTIAL_HSTL _CLASS_II 1 6 m A 2 3 0 1 9 0 1 6 0 —————— 1 8 m A 2 4 0 2 0 0 1 6 0 —————— 2 0 m A 2 5 0 2 1 0 1 7 0 —————— Table 5–45. Maximum Output Clock Toggle Rate on Cyclone II Devices (Part 3 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate on Cyclone II Devices (MHz) Column I/O Pins (1) Row I/O Pins (1) Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade
Altera Corporation 5–51 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications 1.5V_ DIFFERENTIAL_HSTL _CLASS_I 8 mA 210 170 140 210 170 140 210 170 140 1 0 m A 2 2 0 1 8 0 1 5 0 —————— 1 2 m A 2 3 0 1 9 0 1 6 0 —————— 1.5V_ DIFFERENTIAL_HSTL _CLASS_II 1 6 m A 2 1 0 1 7 0 1 4 0 —————— LVDS — 400 340 280 400 340 280 400 340 280 RSDS — 400 340 280 400 340 280 400 340 280 MINI_LVDS — 400 340 280 400 340 280 400 340 280 SIMPLE_RSDS — 380 320 260 380 320 260 380 320 260 1.2V_ DIFFERENTIAL_HSTL PCI — — — — 350 315 280 350 315 280 PCI-X — — — — 350 315 280 350 315 280 LVTTL OCT_25_ OHMS 360 300 250 360 300 250 360 300 250 LVCMOS OCT_25_ OHMS 360 300 250 360 300 250 360 300 250 2.5V OCT_50_ OHMS 240 200 160 240 200 160 240 200 160 1.8V OCT_50_ OHMS 290 240 200 290 240 200 290 240 200 OHMS 240 200 160 240 200 160 — — — OHMS 290 240 200 290 240 200 — — — Note to Table 5–45: (1) This is based on single data rate I/Os. Table 5–45. Maximum Output Clock Toggle Rate on Cyclone II Devices (Part 4 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate on Cyclone II Devices (MHz) Column I/O Pins (1) Row I/O Pins (1) Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade
5–52 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications Table 5–46. Maximum Output Clock Toggle Rate Derating Factors (Part 1 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate Derating Factors (ps/pF) Column I/O Pins Row I/O Pins Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade LVTTL 4 mA 438 439 439 338 362 387 338 362 387 8 mA 306 321 336 267 283 299 267 283 299 12 mA 139 179 220 193 198 202 193 198 202 16 mA 145 158 172 139 147 156 139 147 156 20 mA 65 77 90 74 79 84 74 79 84 24 mA 19 20 21 14 18 22 14 18 22 LVCMOS 4 mA 298 305 313 197 205 214 197 205 214 8 mA 190 205 219 112 118 125 112 118 125 12 mA 43 72 101 27 31 35 27 31 35 2.5V 4 mA 228 233 237 270 306 343 270 306 343 8 mA 173 177 180 191 199 208 191 199 208 1 2 m A 1 1 9 1 2 1 1 2 3 —————— 1.8V 2 mA 452 457 461 332 367 403 332 367 403 4 mA 321 347 373 244 291 337 244 291 337 6 mA 227 255 283 178 222 266 178 222 266 8 mA 37 118 199 58 133 207 58 133 207 10 mA 41 72 103 46 85 123 46 85 123 12 mA 7 8 10 13 28 44 13 28 44 1.5V 2 mA 738 764 789 540 604 669 540 604 669 4 mA 499 518 536 300 354 408 300 354 408 6 mA 261 271 282 60 103 146 60 103 146 SSTL_2_CLASS_I 8 mA 46 47 49 25 40 56 25 40 56 12 mA 67 69 70 23 42 60 23 42 60
Altera Corporation 5–53 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications SSTL_2_CLASS_II 16 mA 42 43 45 15 29 42 15 29 42 SSTL_18_ CLASS_I 6 mA 20 22 24 46 47 49 46 47 49 8 mA 20 22 24 47 49 51 47 49 51 10 mA 20 22 25 23 25 27 23 25 27 1.8V_HSTL_ CLASS_I 8 mA 26 28 29 59 61 63 59 61 63 10 mA 46 47 48 65 66 68 65 66 68 12 mA 67 67 67 71 71 72 71 71 72 1.5V_HSTL_ CLASS_I 8 mA 40 40 41 28 32 36 28 32 36 DIFFERENTIAL_SSTL_2 _CLASS_I 8 mA 46 47 49 25 40 56 25 40 56 12 mA 67 69 70 23 42 60 23 42 60 DIFFERENTIAL_SSTL_2 _CLASS_II 16 mA 42 43 45 15 29 42 15 29 42 DIFFERENTIAL_SSTL_ 18_CLASS_I 6 mA 20 22 24 46 47 49 46 47 49 8 mA 20 22 24 47 49 51 47 49 51 10 mA 20 22 25 23 25 27 23 25 27 Table 5–46. Maximum Output Clock Toggle Rate Derating Factors (Part 2 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate Derating Factors (ps/pF) Column I/O Pins Row I/O Pins Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade
5–54 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications DIFFERENTIAL_SSTL_ 18_CLASS_II 1.8V_ DIFFERENTIAL_HSTL_ CLASS_I 8 mA 26 28 29 59 61 63 59 61 63 10 mA 46 47 48 65 66 68 65 66 68 12 mA 67 67 67 71 71 72 71 71 72 1.8V_ DIFFERENTIAL_HSTL_ CLASS_II 1.5V_ DIFFERENTIAL_HSTL_ CLASS_I 8 mA 40 40 41 28 32 36 28 32 36 1.5V_ DIFFERENTIAL_HSTL_ CLASS_II L V D S — 1 11 31 61 11 31 51 11 31 5 R S D S — 1 11 31 61 11 31 51 11 31 5 MINI_LVDS — 11 13 16 11 13 15 11 13 15 SIMPLE_RSDS — 15 19 23 15 19 23 15 19 23 1 . 2 V _ H S T L — 1 3 0 1 3 2 1 3 3 —————— 1.2V_ DIFFERENTIAL_HSTL PCI — — — — 99 120 142 99 120 142 PCI-X — — — — 99 121 143 99 121 143 LVTTL OCT_25 _OHMS 13 14 14 21 27 33 21 27 33 LVCMOS OCT_25 _OHMS 13 14 14 21 27 33 21 27 33 2.5V OCT_50 _OHMS 346 369 392 324 326 327 324 326 327 1.8V OCT_50 _OHMS 198 203 209 202 203 204 202 203 204 Table 5–46. Maximum Output Clock Toggle Rate Derating Factors (Part 3 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate Derating Factors (ps/pF) Column I/O Pins Row I/O Pins Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade
Altera Corporation 5–55 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications High Speed I/O Timing Specifications The timing analysis for LVDS, mini-LVDS, and RSDS is different compared to other I/O standards because the data communication is source-synchronous. You should also consider board skew, cable skew, and clock jitter in your calculation. This section provides details on the timing parameters for high-speed I/O standards in Cyclone II devices. Table 5–47 defines the parameters of the timing diagram shown in Figure 5–3. SSTL_2_CLASS_I OCT_50 _OHMS 67 69 70 25 42 60 25 42 60 SSTL_18_CLASS_I OCT_50 _OHMS 30 33 36 47 49 51 47 49 51 Table 5–46. Maximum Output Clock Toggle Rate Derating Factors (Part 4 of 4) I/O Standard Drive Strength Maximum Output Clock Toggle Rate Derating Factors (ps/pF) Column I/O Pins Row I/O Pins Dedicated Clock Outputs Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Speed Grade Table 5–47. High-Speed I/O Timing Definitions (Part 1 of 2) Parameter Symbol Description High-speed clock f HSCKLK High-speed receiver and transmitter input and output clock frequency. Duty cycle t DUTY Duty cycle on high-speed transmitter output clock. High-speed I/O data rate HSIODR High-speed receiv er and transmitter input and output data rate. Time unit interval TUI TUI = 1/HSIODR. Channel-to-channel skew TCCS The ti ming difference between the fastest and slowest output edges, including tCO variation and clock skew. The clock is included in the TCCS measurement. TCCS = TUI – SW – (2 × RSKM)
Altera Corporation 5–57 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Figure 5–4. High-Speed I/O Timing Budget Note (1) Note to Figure 5–4: (1) The equation for the high-speed I/O timing budget is: period = TCCS + RSKM + SW + RSKM. Table 5–48 shows the RSDS timing budget for Cyclone II devices at 311 Mbps. RSDS is supported for transmitting from Cyclone II devices. Cyclone II devices cannot receive RSDS data because the devices are intended for applications where they will be driving display drivers. Cyclone II devices support a maximum RSDS data rate of 311 Mbps using DDIO registers. Cyclone II devices support RSDS only in the commercial temperature range. Internal Clock Period RSKM 0.5 × TCCS RSKM 0.5 × TCCSSW Table 5–48. RSDS Transmitter Timing Specification (Part 1 of 2) Symbol Conditions –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Min Typ Max (1) Min Typ Max (1) Min Typ Max (1) fHSCLK (input clock frequency) ×10 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×8 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×7 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×4 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×2 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×1 10 — 311 10 — 311 10 — 311 MHz Device operation in Mbps ×10 100 — 311 100 — 311 100 — 311 Mbps ×8 80 — 311 80 — 311 80 — 311 Mbps ×7 70 — 311 70 — 311 70 — 311 Mbps ×4 40 — 311 40 — 311 40 — 311 Mbps ×2 20 — 311 20 — 311 20 — 311 Mbps ×1 10 — 311 10 — 311 10 — 311 Mbps t DUTY — 45 — 55 45 — 55 45 — 55 %
5–58 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications In order to determine the transmitter timing requirements, RSDS receiver timing requirements on the other end of the link must be taken into consideration. RSDS receiver timing parameters are typically defined as tSU and tH requirements. Therefore, the transmitter timing parameter specifications are tCO (minimum) and tCO (maximum). Refer to Figure 5–4 for the timing budget. The AC timing requirements for RSDS are shown in Figure 5–5. Output jitter (peak to peak) tRISE 20–80%, CLOAD = 5 pF tFALL 80–20%, CLOAD = 5 pF tLOCK — — 100 — 100 — — 100 μs Note to Table 5–48: (1) These specifications are for a thre e-resistor RSDS implementation. For single-resistor RSDS in ×10 through ×2 modes, the maximum data rate is 170 Mbps and the corresponding maximum input clock frequency is 85 MHz. For single-resistor RSDS in ×1 mode, the maximum data rate is 170 Mbps, and the maximum input clock frequency is 170 MHz. For more information about the different RSDS implementations, refer to the High-Speed Differential Interfaces in Cyclone II Devices chapter of the Cyclone II Device Handbook. Table 5–48. RSDS Transmitter Timing Specification (Part 2 of 2) Symbol Conditions –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Min Typ Max (1) Min Typ Max (1) Min Typ Max (1)
Altera Corporation 5–59 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Figure 5–5. RSDS Transmitter Clock to Data Relationship Table 5–49 shows the mini-LVDS transmitter timing budget for Cyclone II devices at 311 Mbps. Cyclone II devices cannot receive mini-LVDS data because the devices are intended for applications where they will be driving display drivers. A maximum mini-LVDS data rate of 311 Mbps is supported for Cyclone II devices using DDIO registers. Cyclone II devices support mini-LVDS only in the commercial temperature range. Transmitter Valid Data Transmitter Valid Data Valid Data Total Skew Valid Data tSU (2 ns) tH (2 ns) Channel-to-Channel Skew (1.68 ns) Transmitter Clock (5.88 ns) At transmitter tx_data[11..0] At receiver rx_data[11..0] Table 5–49. Mini-LVDS Transmitter Timing Specification (Part 1 of 2) Symbol Conditions –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Min Typ Max Min Typ Max Min Typ Max fHSCLK (input clock frequency) ×10 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×8 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×7 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×4 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×2 10 — 155.5 10 — 155.5 10 — 155.5 MHz ×1 10 — 311 10 — 311 10 — 311 MHz
5–60 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications In order to determine the transmitter timing requirements, mini-LVDS receiver timing requirements on the other end of the link must be taken into consideration. The mini-LVDS receiver timing parameters are typically defined as tSU and tH requirements. Therefore, the transmitter timing parameter specifications are tCO (minimum) and tCO (maximum). Refer to Figure 5–4 for the timing budget. The AC timing requirements for mini-LVDS are shown in Figure 5–6. Figure 5–6. mini-LVDS Transmitter AC Timing Specification Notes to Figure 5–6: (1) The data setup time, t SU, is 0.225 × TUI. (2) The data hold time, t H, is 0.225 × TUI. Device operation in Mbps ×10 100 — 311 100 — 311 100 — 311 Mbps ×8 80 — 311 80 — 311 80 — 311 Mbps ×7 70 — 311 70 — 311 70 — 311 Mbps ×4 40 — 311 40 — 311 40 — 311 Mbps ×2 20 — 311 20 — 311 20 — 311 Mbps ×1 10 — 311 10 — 311 10 — 311 Mbps t DUTY — 45 — 55 45 — 55 45 — 55 % Output jitter (peak to peak) t RISE 20–80% — — 500 — — 500 — — 500 ps tFALL 80–20% — — 500 — — 500 — — 500 ps tLOCK — — 100 — — 100 — — 100 μs Table 5–49. Mini-LVDS Transmitter Timing Specification (Part 2 of 2) Symbol Conditions –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Min Typ Max Min Typ Max Min Typ Max tSU (1) tH (2) TUI tSU (1) tH (2) LVDSCLK[]n LVDSCLK[]p LVDS[]p LVDS[]n
Altera Corporation 5–61 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Tables 5–50 and 5–51 show the LVDS timing budget for Cyclone II devices. Cyclone II devices support LVDS receivers at data rates up to 805 Mbps, and LVDS transmitters at data rates up to 640 Mbps. Table 5–50. LVDS Transmitter Timing Specification (Part 1 of 2) Symbol Conditions –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Min Typ Max (1) Max (2) Min Typ Max (1) Max (2) Min Typ Max (1) Max (2) fHSCLK (input clock fre- quency) ×10 10 — 320 320 10 — 275 320 10 — 155.5 (4) 320 (6) MHz ×8 10 — 320 320 10 — 275 320 10 — 155.5 (4) 320 (6) MHz ×7 10 — 320 320 10 — 275 320 10 — 155.5 (4) 320 (6) MHz ×4 10 — 320 320 10 — 275 320 10 — 155.5 (4) 320 (6) MHz ×2 10 — 320 320 10 — 275 320 10 — 155.5 (4) 320 (6) MHz (8) 402.5 (8) MHz HSIODR ×10 100 — 640 640 100 — 550 640 100 — 311 (5) 550 (7) Mbps ×8 80 — 640 640 80 — 550 640 80 — 311 (5) 550 (7) Mbps ×7 70 — 640 640 70 — 550 640 70 — 311 (5) 550 (7) Mbps ×4 40 — 640 640 40 — 550 640 40 — 311 (5) 550 (7) Mbps ×2 20 — 640 640 20 — 550 640 20 — 311 (5) 550 (7) Mbps (9) 402.5 (9) Mbps tDUTY — 45 — 55 — 45 — 55 — 45 — 55 — % TCCS (3) Output jitter (peak to peak) —— — 500 —— 500 —— 550 (10) ps tRISE 20–80% 150 200 250 150 200 250 150 200 250 (11) ps
5–62 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications tFALL 80–20% 150 200 250 150 200 250 150 200 250 (11) ps tLOCK —— — 100 —— 100 —— 100 (12) μs Notes to T able 5–50: (1) The maximum data rate that complies with duty cycle distortion of 45–55%. (2) The maximum data rate when taking duty cycle in abso lute ps into consideration that may not comply with 45–55% duty cycle distortion. If the downstream receiver can handle duty cycle distortion beyond the 45–55% range, you may use the higher data rate values from this column. You can calculate the duty cycle distortion as a percentage using the absolute ps value. For example, for a data rate of 640 Mbps (UI = 1562.5 ps) and a tDUTY of 250 ps, the duty cycle distortion is ± tDUTY /(UI*2) *100% = ± 250 ps/(1562.5 *2) * 100% = ± 8%, which gives you a duty cycle distortion of 42–58%. (3) The TCCS specification applies to the entire bank of LVDS , as long as the SERDES logic is placed within the LAB adjacent to the output pins. (4) For extended temperature devices, the maximum input clock frequency for ×10 through ×2 modes is 137.5 MHz. (5) For extended temperature device s, the maximum data rate for ×10 through ×2 modes is 275 Mbps. (6) For extended temperatur e devices, the maximum input clock frequency for ×10 through ×2 modes is 200 MHz. (7) For extended temperature device s, the maximum data rate for ×10 through ×2 modes is 400 Mbps. (8) For extended temperature devi ces, the maximum input clock frequency for ×1 mode is 340 MHz. (9) For extended temperature de vices, the maximum data rate for ×1 mode is 340 Mbps. (10) For extended temperature de vices, the maximum output jitter (peak to peak) is 600 ps. (11) For extended temperature devices, the maximum t RISE and tFALL are 300 ps. (12) For extended temperat ure devices, the maximum lock time is 500 us. Table 5–50. LVDS Transmitter Timing Specification (Part 2 of 2) Symbol Conditions –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Min Typ Max (1) Max (2) Min Typ Max (1) Max (2) Min Typ Max (1) Max (2)
Altera Corporation 5–63 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications External Memory Interface Specifications Table 5–52 shows the DQS bus clock skew adder specifications. Table 5–51. LVDS Receiver Timing Specification Symbol Conditions –6 Speed Grade –7 Speed Grade –8 Speed Grade Unit Min Typ Max Min Typ Max Min Typ Max fHSCLK (input clock frequency) ×10 10 — 402.5 10 — 320 10 — 320 (1) MHz ×8 10 — 402.5 10 — 320 10 — 320 (1) MHz ×7 10 — 402.5 10 — 320 10 — 320 (1) MHz ×4 10 — 402.5 10 — 320 10 — 320 (1) MHz ×2 10 — 402.5 10 — 320 10 — 320 (1) MHz ×1 10 — 402.5 10 — 402.5 10 — 402.5 (3) MHz HSIODR ×10 100 — 805 100 — 640 100 — 640 (2) Mbps ×8 80 — 805 80 — 640 80 — 640 (2) Mbps ×7 70 — 805 70 — 640 70 — 640 (2) Mbps ×4 40 — 805 40 — 640 40 — 640 (2) Mbps ×2 20 — 805 20 — 640 20 — 640 (2) Mbps ×1 10 — 402.5 10 — 402.5 10 — 402.5 (4) Mbps Input jitter tolerance tLOCK — — — 100 — — 100 — — 100 (5) ps Notes to T able 5–51: (1) For extended temperatur e devices, the maximum input clock frequency for x10 through x2 modes is 275 MHz. (2) For extended temperature device s, the maximum data rate for x10 through x2 modes is 550 Mbps. (3) For extended temperature devi ces, the maximum input clock frequency for x1 mode is 340 MHz. (4) For extended temperature de vices, the maximum data rate for x1 mode is 340 Mbps. (5) For extended temperat ure devices, the maximum lock time is 500 us. Table 5–52. DQS Bus Clock Skew Adder Specifications Mode DQS Clock Skew Adder Unit ×9 155 ps ×18 190 ps Note to T able 5–52: (1) This skew specification is the absolute maximum and minimum skew. For example, skew on a ×9 DQ group is 155 ps or ±77.5 ps.
Altera Corporation 5–65 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Table 5–53 shows the JTAG timing parameters and values for Cyclone II devices.
1 Cyclone II devices must be within the first 17 devices in a JTAG
chain. All of these devices have the same JTAG controller. If any of the Cyclone II devices are in the 18th position or after they will fail configuration. This does not affect the SignalTap ® II logic analyzer. f For more information on JTAG, refer to the IEEE 1149.1 (JTAG) Boundary-Scan Testing for Cyclone II Devices chapter in the Cyclone II Handbook. Table 5–53. Cyclone II JTAG Timing Parameters and Values Symbol Parameter Min Max Unit tJCP TCK clock period 40 — ns tJCH TCK clock high time 20 — ns tJCL TCK clock low time 20 — ns tJPSU JTAG port setup time (2) 5— n s tJPH JTAG port hold time 10 — ns tJPCO JTAG port clock to output (2) —1 3 n s tJPZX JTAG port high impedance to valid output (2) —1 3 n s tJPXZ JTAG port valid output to high impedance (2) —1 3 n s tJSSU Capture register setup time (2) 5— n s tJSH Capture register hold time 10 — ns tJSCO Update register clock to output — 25 ns tJSZX Update register high impedance to valid output — 25 ns tJSXZ Update register valid output to high impedance — 25 ns Notes to T able 5–53: (1) This information is preliminary. (2) This specification is shown for 3.3-V LVTTL/LVCMOS an d 2.5-V LVTTL/LVCMOS operation of the JTAG pins. For 1.8-V LVTTL/LVCMOS and 1.5-V LVCMOS, the JTAG port and capture register clock setup time is 3 ns and port clock to output time is 15 ns.
5–66 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Timing Specifications PLL Timing Specifications Table 5–54 describes the Cyclone II PLL specifications when operating in the commercial junction temperature range (0° to 85° C), the industrial junction temperature range (–40° to 100° C), the automotive junction temperature range (–40° to 125° C), and the extended temperature range (–40° to 125° C). Follow the PLL specifications for –8 speed grade devices when operating in the industrial, automotive, or extended temperature range. Table 5–54. PLL Specifications Note (1) (Part 1 of 2) Symbol Parameter Min Typ Max Unit fIN Input clock frequency (–6 speed grade) 10 — (4) MHz Input clock frequency (–7 speed grade) 10 — (4) MHz Input clock frequency (–8 speed grade) 10 — (4) MHz fINPFD PFD input frequency (–6 speed grade) 10 — 402.5 MHz PFD input frequency (–7 speed grade) 10 — 402.5 MHz PFD input frequency (–8 speed grade) 10 — 402.5 MHz f INDUTY Input clock duty cycle 40 — 60 % tINJITTER (5) Input clock period jitter — 200 — ps fOUT_EXT (external clock output) PLL output frequency (–6 speed grade) 10 — (4) MHz PLL output frequency (–7 speed grade) 10 — (4) MHz PLL output frequency (–8 speed grade) 10 — (4) MHz fOUT (to global clock) PLL output frequency (–6 speed grade) 10 — 500 MHz PLL output frequency (–7 speed grade) 10 — 450 MHz PLL output frequency (–8 speed grade) 10 — 402.5 MHz tOUTDUTY Duty cycle for external clock output (when set to 50%) 45 — 55 % tJITTER (p-p) (2) Period jitter for external clock output fOUT_EXT > 100 MHz —— 3 0 0 p s fOUT_EXT ≤ 100 MHz — — 30 mUI tLOCK Time required to lock from end of device configuration — — 100 (6) μs tPLL_PSERR Accuracy of PLL phase shift — — ±60 ps
5–68 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Duty Cycle Distortion (T/2 – D1) / T (the low percentage boundary) (T/2 + D2) / T (the high percentage boundary) DCD Measurement Techniques DCD is measured at an FPGA output pin driven by registers inside the corresponding I/O element (IOE) block. When the output is a single data rate signal (non-DDIO), only one edge of the register input clock (positive or negative) triggers output transitions (Figure 5–9). Therefore, any DCD present on the input clock signal, or caused by the clock input buffer, or different input I/O standard, does not transfer to the output signal. Figure 5–9. DCD Measurement Technique for Non-DDIO (Single-Data Rate) Outputs However, when the output is a double data rate input/output (DDIO) signal, both edges of the input clock signal (positive and negative) trigger output transitions (Figure 5–10). Therefore, any distortion on the input clock and the input clock buffer affect the output DCD. DQ DFF clk output IOE
Altera Corporation 5–69 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications Figure 5–10. DCD Measurement Technique for DDIO (Double-Data Rate) Outputs When an FPGA PLL generates the internal clock, the PLL output clocks the IOE block. As the PLL only monitors the positive edge of the reference clock input and internally re-creates the output clock signal, any DCD present on the reference clock is filtered out. Therefore, the DCD for a DDIO output with PLL in the clock path is better than the DCD for a DDIO output without PLL in the clock path. Tables 5–55 through 5–58 give the maximum DCD in absolution derivation for different I/O standards on Cyclone II devices. Examples are also provided that show how to calculate DCD as a percentage. DQ PRN CLRN DFF INPUT VCCclk output DQ PRN CLRN DFFVCC GND Table 5–55. Maximum DCD for Single Data Outputs (SDR) on Row I/O Pins Notes (1), (2) (Part 1 of 2) Row I/O Output Standard C6 C7 C8 Unit LVCMOS 165 230 230 ps LVTTL 195 255 255 ps 2.5-V 120 120 135 ps 1.8-V 115 115 175 ps 1.5-V 130 130 135 ps SSTL-2 Class I 60 90 90 ps SSTL-2 Class II 65 75 75 ps SSTL-18 Class I 90 165 165 ps HSTL-15 Class I 145 145 205 ps HSTL-18 Class I 85 155 155 ps
5–70 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Duty Cycle Distortion Here is an example for calculating the DCD as a percentage for an SDR output on a row I/O on a –6 device: If the SDR output I/O standard is SSTL-2 Class II, the maximum DCD is 65 ps (refer to Table 5–55). If the clock frequency is 167 MHz, the clock period T is: T = 1/ f = 1 / 167 MHz = 6 ns = 6000 ps To calculate the DCD as a percentage: (T/2 – DCD) / T = (6000 ps/2 – 65 ps) / 6000 ps = 48.91% (for low boundary) (T/2 + DCD) / T = (6000 ps/2 + 65 ps) / 6000ps = 51.08% (for high boundary Differential SSTL-2 Class I 60 90 90 ps Differential SSTL-2 Class II 65 75 75 ps Differential SSTL-18 Class I 90 165 165 ps Differential HSTL-18 Class I 85 155 155 ps Differential HSTL-15 Class I 145 145 205 ps LVDS 60 60 60 ps Simple RSDS 60 60 60 ps Mini LVDS 60 60 60 ps PCI 195 255 255 ps PCI-X 195 255 255 ps Notes to Tab le 5–55: (1) The DCD specification is characterized using the maximum drive strength available for each I/O standard. (2) Numbers are applicable for commercial, industrial, and automotive devices. Table 5–56. Maximum DCD for SDR Output on Column I/O Notes (1), (2) (Part 1 of 2) Column I/O Output Standard C6 C7 C8 Unit LVCMOS 195 285 285 ps LVTTL 210 305 305 ps Table 5–55. Maximum DCD for Single Data Outputs (SDR) on Row I/O Pins Notes (1), (2) (Part 2 of 2) Row I/O Output Standard C6 C7 C8 Unit
Altera Corporation 5–71 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications 2.5-V 140 140 155 ps 1.8-V 115 115 165 ps 1.5-V 745 745 770 ps SSTL-2 Class I 60 60 75 ps SSTL-2 Class II 60 60 80 ps SSTL-18 Class I 60 130 130 ps SSTL-18 Class II 60 135 135 ps HSTL-18 Class I 60 115 115 ps HSTL-18 Class II 75 75 100 ps HSTL-15 Class I 150 150 150 ps HSTL-15 Class II 135 135 155 ps Differential SSTL-2 Class I 60 60 75 ps Differential SSTL-2 Class II 60 60 80 ps Differential SSTL-18 Class I 60 130 130 ps Differential SSTL-18 Class II 60 135 135 ps Differential HSTL-18 Class I 60 115 115 ps Differential HSTL-18 Class II 75 75 100 ps Differential HSTL-15 Class I 150 150 150 ps Differential HSTL-15 Class II 135 135 155 ps LVDS 60 60 60 ps Simple RSDS 60 70 70 ps Mini-LVDS 60 60 60 ps Notes to Tab le 5–56: (1) The DCD specification is characterized using the maximum drive strength available for each I/O standard. (2) Numbers are applicable for commercial, industrial, and automotive devices. Table 5–57. Maximum for DDIO Output on Row Pins with PLL in the Clock Path Notes (1), (2) (Part 1 of 2) Row Pins with PLL in the Clock Path C6 C7 C8 Unit LVCMOS 270 310 310 ps LVTTL 285 305 335 ps 2.5-V 180 180 220 ps 1.8-V 165 175 205 ps Table 5–56. Maximum DCD for SDR Output on Column I/O Notes (1), (2) (Part 2 of 2) Column I/O Output Standard C6 C7 C8 Unit
5–72 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Duty Cycle Distortion For DDIO outputs, you can calculate actual half period from the following equation: Actual half period = ideal half period – maximum DCD For example, if the DDR output I/O standard is SSTL-2 Class II, the maximum DCD for a –5 device is 155 ps (refer to Table 5–57). If the clock frequency is 167 MHz, the half-clock period T/2 is: 1.5-V 280 280 280 ps SSTL-2 Class I 150 190 230 ps SSTL-2 Class II 155 200 230 ps SSTL-18 Class I 180 240 260 ps HSTL-18 Class I 180 235 235 ps HSTL-15 Class I 205 220 220 ps Differential SSTL-2 Class I 150 190 230 ps Differential SSTL-2 Class II 155 200 230 ps Differential SSTL-18 Class I 180 240 260 ps Differential HSTL-18 Class I 180 235 235 ps Differential HSTL-15 Class I 205 220 220 ps LVDS 95 110 120 ps Simple RSDS 100 155 155 ps Mini LVDS 95 110 120 ps PCI 285 305 335 ps PCI-X 285 305 335 ps Notes to Tab le 5–57: (1) The DCD specification is characterized using the maximum drive strength available for each I/O standard. (2) Numbers are applicable for commercial, industrial, and automotive devices. Table 5–57. Maximum for DDIO Output on Row Pins with PLL in the Clock Path Notes (1), (2) (Part 2 of 2) Row Pins with PLL in the Clock Path C6 C7 C8 Unit
Altera Corporation 5–73 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications The actual half period is then = 3000 ps – 155 ps = 2845 ps Table 5–58. Maximum DCD for DDIO Output on Column I/O Pins with PLL in the Clock Path Notes (1), (2) Column I/O Pins in the Clock Path C6 C7 C8 Unit LVCMOS 285 400 445 ps LVTTL 305 405 460 ps 2.5-V 175 195 285 ps 1.8-V 190 205 260 ps 1.5-V 605 645 645 ps SSTL-2 Class I 125 210 245 ps SSTL-2 Class II 195 195 195 ps SSTL-18 Class I 130 240 245 ps SSTL-18 Class II 135 270 330 ps HSTL-18 Class I 135 240 240 ps HSTL-18 Class II 165 240 285 ps HSTL-15 Class I 220 335 335 ps HSTL-15 Class II 190 210 375 ps Differential SSTL-2 Class I 125 210 245 ps Differential SSTL-2 Class II 195 195 195 ps Differential SSTL-18 Class I 130 240 245 ps Differential SSTL-18 Class II 132 270 330 ps Differential HSTL-18 Class I 135 240 240 ps Differential HSTL-18 Class II 165 240 285 ps Differential HSTL-15 Class I 220 335 335 ps Differential HSTL-15 Class II 190 210 375 ps LVDS 110 120 125 ps Simple RSDS 125 125 275 ps Mini-LVDS 110 120 125 ps Notes to Tab le 5–58: (1) The DCD specification is characterized using the maximum drive strength available for each I/O standard. (2) Numbers are applicable for commercial, industrial, and automotive devices.
5–74 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Referenced Documents Referenced Documents This chapter references the following documents: ■ Cyclone II Architecture chapter in Cyclone II Device Handbook ■ High-Speed Differential Interfaces in Cyclone II Devices chapter of the Cyclone II Device Handbook ■ IEEE 1149.1 (JTAG) Boundary-Scan Testing for Cyclone II Devices chapter in the Cyclone II Handbook ■ Operating Requirements for Altera Devices Data Sheet ■ PowerPlay Early Power Estimator User Guide ■ PowerPlay Power Analysis chapters in volume 3 of the Quartus II Handbook Document Table 5–59 shows the revision history for this document. Table 5–59. Document Revision History Date and Document Version Changes Made Summary of Changes February 2008 v4.0
- Updated the following tables with I/O timing numbers for automotive-grade devices: 5–57, and 5–58.
- Added “Referenced Documents”. Added I/O timing numbers for automotive-grade devices. April 2007 v3.2
- Updated Table 5–3. Updated R CONF typical and maximum values in Table 5–3.
Altera Corporation 5–75 February 2008 Cyclone II Device Handbook, Volume 1 DC Characteristics and Timing Specifications February 2007 v3.1
- Added document revision history.
- Added VCCA minimum and maximum limitations in Table 5–1.
- Updated Note (1) in Table 5–2.
- Updated the maximum VCC rise time for Cyclone II “A” devices in Table 5–2.
- Updated RCONF information in Table 5–3.
- Changed VI to Ii in Table 5–3.
- Updated LVPECL clock inputs in Note (6) to Table 5–8.
- Updated Note (1) to Table 5–12.
- Updated CVREF capacitance description in Table 5–13.
- Updated “Timing Specifications” section.
- Updated Table 5–45.
- Added Table 5–46 with information on toggle rate derating factors.
- Corrected calculation of the period based on a 640 Mbps data rate as 1562.5 ps in Note (2) to Table 5–50.
- Updated “PLL Timing Specifications” section.
- Updated VCO range of 300–500 MHz in Note (3) to Table 5–54.
- Updated chapter with extended temperature information. December 2005 v2.2 Updated PLL Timing Specifications — November 2005 v2.1 Updated technical content throughout. — July 2005 v2.0 Updated technical content throughout. — November 2004 v1.1 Updated the “Differential I/O Standards” section. Updated Table 5–54. June 2004 v1.0 Added document to the Cyclone II Device Handbook. —
5–76 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2008 Document Revision History
Altera Corporation 6–1 February 2007 6. Reference & Ordering Information Software Cyclone® II devices are supported by the Altera® Quartus® II design software, which provides a comprehensive environment for system-on-a-programmable-chip (SOPC) design. The Quartus II software includes HDL and schematic design entry, compilation and logic synthesis, full simulation and advanced timing analysis, SignalTap® II logic analyzer, and device configuration. See the Quartus II Handbook for more information on the Quartus II software features. The free Quartus II Web Edition software, available at www.Altera.com, supports Microsoft Windows XP and Windows 2000. The full version of Quartus II software is available through the Altera subscription program. The full version of Quartus II software supports all Altera devices, is available for Windows XP , Windows 2000, Sun Solaris, and Red Hat Linux operating systems, and includes a free suite of popular IP MegaCore ® functions for DSP applications and interfacing to external memory devices. Quartus II software and Quartus II Web Edition software support seamless integration with your favorite third party EDA tools. Device Pin-Outs Device pin-outs for Cyclone II devices are available on the Altera web site (www.altera.com). For more information contact Altera Applications. Ordering Information Figure 6–1 describes the ordering codes for Cyclone II devices. For more information on a specific package, contact Altera Applications. CII51006-1.4
6–2 Altera Corporation Cyclone II Device Handbook, Volume 1 February 2007 Document Revision History Figure 6–1. Cyclone II Device Packaging Ordering Information Document Table 6–1 shows the revision history for this document. Device Type Package Type 6, 7, or 8, with 6 being the fastest Number of pins for a particular package ES: Thin quad flat pack (TQFP) Plastic quad flat pack (PQFP) FineLine BGA Ultra FineLine BGA EP2C: Cyclone II C: Commercial temperat ure (t J = 0° C to 85° C) Industrial temperature (tJ = -40° C to 100° C) Optional SuffixFamily Signature Operating Temperature Speed Grade Pin Count Engineering sample 7EP2C 70 C 324FE S Indicates specific device options or shipment method. N: Lead-free de vices A Fast-On Indicates devices with fast POR (Power on Reset) time. Table 6–1. Document Revision History Date & Document Version Changes Made Summary of Changes February 2007 v1.5
- Added document revision history.
- Updated Figure 6–1.
- Added Ultra FineLine BGA detail in UBGA Package information in Figure 6–1. November 2005 v1.2 Updated software introduction. November 2004 v1.1 Updated Figure 6–1. June 2004 v1.0 Added document to the Cyclone II Device Handbook.