ECS65 XPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
- Safety approvals cover frequency 4 7 -63 H z. AC-DC Specification 65/100/130 Watts
- IT & Medical Safety Approvals
- 65/80/100 W - Convection-cooled Ratings
- Class I & Class II Construction
- Industry Standard 2”x 4”Package
- <0.5 W No Load Input Power
- Low Leakage Current
- 3 Year Warranty ECS Series Input Input Voltage • 80-264 VA C (27 5 VA C EC S65) (120-37 0 VDC ), derate output pow er <9 0 VA C , see derating curves Input Frequency • 4 7 -4 00 H z (1) Input C urrent • 65 W : 1.0/0.6 A typical at 115/230 VA C 100 W : 1.5/0.9 A typical at 115/230 VA C , 130 W : 1.9 /1.1 A typical at 115/230 VA C full load Inrush C urrent • 4 0 A m ax at 230 VA C , cold start at 25 ˚C Pow er Factor • EN 61000-3-2, class A N o Load Input Pow er • <0.5 W Earth Leakage C urrent • 65/130 W : 260 µA at 264 VA C /60 H z m ax
100 W : 230 µA at 264 VA C /60 H z m ax
Input Protection • Internal T3.15/T5 A /250 V fuse in line and neutral Output O utput Voltage • 12-4 8 VDC (see tables) O utput Voltage Trim • ±10% Initial Set Accuracy • ±1% M inim um Load • N o m inim um load required Start U p D elay • 1 s typical Start U p R ise Tim e • 50 m s H old U p Tim e • 16 m s m in at 115 VA C D rift • ±0.2% after 20 m in w arm up Line R egulation • ±0.5% m ax Load R egulation • ±1% O ver/U ndershoot • 5% typical Transient R esponse • 4 % m ax. deviation, recovery to w ithin 1% in 500 µs for a 50-7 5-50% load change R ipple & N oise • 1% pk-pk, 20 M H z bandw idth O vervoltage Protection • 115-14 0% Vnom , recycle input to reset O verload Protection • 110-160% Short C ircuit Protection • C ontinuous trip and restart (hiccup m ode) Tem perature • 0.05% /˚C C oefficient xppow er.com General Efficiency • U p to 9 0% m odel dependent Isolation • 4 000 VA C Input to O utput, 2 x M O P P ,
1500 VA C Input to G round, 1 x M O P P ,
500 VDC O utput to G round, 1 x M O P P
Sw itching Frequency • 65 K H z typical Pow er D ensity • 65 W : 7 .7 W /in 3, 100 W : 10 W /in 3,
130 W : 13 W /in 3
M TB F • 65 W : 850 kH rs, 100 W : 834 kH rs,
130 W : 7 15 kH rs to M IL-H DBK -217 F
at 25 ˚C , G B Environmental O perating Tem perature • -20 ˚C (-4 0 ˚C , EC S130) to +7 0 ˚C derate linearly from +50 ˚C at 2.5% /˚C to 50% load at +7 0 ˚C . C ooling • C onvection & fan cooled rating s(see tables) O perating H um idity • 9 5% R H , non-condensing Storage Tem perature • -4 0 ˚C to +85 ˚C O perating Altitude • 65-100 W : 3000 m , 130 W : 5000m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rm s, 5 H z to 500 H z, 3 axes EMC & Safety Low Voltage PSU EM C • EN 61204 -3, high severity level Em issions • EN 55011/22 level B conducted EN 55011/22 level A radiated, level B Suffix ‘-B’ m odels H arm onic C urrents • EN 61000-3-2, class A Voltage Flicker • EN 61000-3-3 ESD Im m unity • EN 61000-4 -2, ±6 kV C ontact, ±15 kV A ir Discharge, P erf C riteria A R adiated Im m unity • EN 61000-4 -3, level 3 P erf C riteria A EFT/B urst • EN 61000-4 -4 , level 3 P erf C riteria A Surge • EN 61000-4 -5, installation class 3 P erf C riteria A C onducted Im m unity • EN 61000-4 -6, level 3 P erf C riteria A D ips & Interruptions • EN 61000-4 -11 , 30% 10 m s, 60% 100 m s, 100% 5000 m s, P erf C riteria A , B, B , EN 60601-1-2, 30% 500 m s, 60% 100 m s, 100% 10 m s, 100% 5000 m s, P erf C riteria A , A , A , B - 230 VA C . C onsult longform datasheet for 115 V operation. Safety Approvals • IEC 609 50-1 C B report, C SA 22.2 N o. 609 50-1, U L 609 50-1, TU V EN 609 50-1 IEC 60601-1 C B report, C SA 22.2 N o. 60601-1, A N SI/A M M I ES60601-1, TU V 60601-1, including risk m anagem ent Equipm ent Protection • C lass I & II (EC S65 N on ‘-B’ m odels, C lass C las s I only)
0.20 (5.1) 1.05 (26.7) 0.14 (3.5) SMD Component Height 2.00 (50.8) 0.95 (24.1) 0.125 (3.18) 1.75 (44.45) J1 0.96 (24.5) 0.20 (5.1) 4.00 (101.6)
0.25 Faston Ground Tab
4 X ø.156 (3.96) Mounting Holes ø.312 (7.92) Clearance top and bottom ECS65 Models and Ratings Mechanical Details Derating Curve - ECS65 Models Notes 1. A ll dim ensions in inches (m m ). 2. W eight: 0.386 lbs (17 5 g) J1 m ates w ith M olex H ousing P N 09 -50-1031, J2 m ates w ith M olex H ousing P N 09 -50-104 1 and both w ith M olex Series 519 4 C rim p T erm inals Notes In put C onnector J1 M olex PN 09-65-2 038 P in 1 L ine P in 2 N eutral 0.25” Faston Earth O utput C onnector J2 M olex PN 09-65-2 04 8 P in 1 +V1 P in 2 +V1 P in 3 RTN P in 4 RTN 1. For C lass B radiated em issions m odels, add suffix -B to m odel num ber. For covered versions, add suffix ‘-C ’ to m odel num ber or order part no. EC M 40/60 C O VER K IT for standalone cover. D erate output pow er by 20% w ith cover. The cover is not suitable for C lass II installations. O utput Pow er O utput Voltage O utput C urrent M odel N um ber (1) 65 W 12.0 VDC 5.4 A EC S65U S12 65 W 15.0 VDC 4 .3 A EC S65U S15 65 W 18.5 VDC 3.4 A EC S65U S18 65 W 24 .0 VDC 2.7 A EC S65U S24 65 W 28.0 VDC 2.3 A EC S65U S28 65 W 4 8.0 VDC 1.4 A EC S65U S4 8 100 80 90 85 275 Input Voltage (VAC) Output Power (%) 37 .5 100 -20 50 40 60 Ambient T emperature ( ºC) Open Frame Output Power (%)
4.00 (101.6) 4.50 (114.3) 3.75 (95.25) 0.37 (9.52) 1.75 (44.45) 1.01 (25.7) 0.125 (3.18) 0.20 (5.1) 0.10 (2.5) 0.125 (3.18) 2.00 (50.8) 1.00 (25.4) 0.125 (3.18) 0.20 (5.1)
0.25 Faston
4 X ø .156 (3.96) Mounting Holes ø .312 (7.92) Clearance top and bottom 4 X ø .156 (3.96) Mounting Holes ø .312 (7.92) Clearance top and bottom 1.01 (25.7) Voltage Adj. 1.750 (44.45) 3.750 (95.25) 0.20 (5.1) 0.20 (5.1) 2.00 (50.8) 1.25 (31.8) 0.14 (3.5) SMD Component Height 1.25 (31.8) 0.14 (3.5) SMD Component Height 1.00 (25.4) ECS100 Models and Ratings Mechanical Details Derating Curve - ECS100 Models Notes 1. A ll dim ensions in inches (m m ). T olerance .xx = ±0.02 (0.50); 2. W eight: 0.386 lbs (17 5 g) J1 m ates w ith M olex H ousing P N 09 -50-1031, J2 m ates w ith M olex H ousing P N 09 -50-104 1 and both w ith M olex Series 519 4 C rim p T erm inals Notes In put C onnector J1 M olex PN 09-65-2 038 P in 1 L ine P in 2 N eutral 0.25” Faston Earth O utput C onnector J2 M olex PN 09-65-2 04 8 P in 1 +V1 P in 2 +V1 P in 3 RTN P in 4 RTN 1. For C lass B radiated em issions m odels, add suffix -B to m odel num ber. For covered versions, add suffix ‘-C ’ to m odel num ber or order part no. EC M 40/60 C O VER K IT for standalone cover. D erate output pow er by 20% w ith cover. The cover is not suitable for C lass II installations. ‘-C ’ not available for ‘-B ’ m odels. O utput Pow er O utput Voltage O utput C urrent M odel N um ber (1) Forced C ooled (10 C FM ) C onvection-cooled 100 W 80 W 12.0 VDC 8.3 A EC S100U S12 100 W 80 W 15.0 VDC 6.7 A EC S100U S15 100 W 80 W 18.0 VDC 5.5 A EC S100U S18 100 W 80 W 24 .0 VDC 4 .2 A EC S100U S24 100 W 80 W 28.0 VDC 3.6 A EC S100U S28 100 W 80 W 4 8.0 VDC 2.1 A EC S100U S4 8 +70 100 -20 +50 +40 +60 Ambient Temperature (º C) Output Power (W) 100 80 90 85 264 Input Voltage (VAC) Output Power (%) Force-cooled >10 CFM Convection-cooled Convection-cooled with cover ‘-B’Model
4X 0.156 (3.96) MOUNTING HOLES 0.312 (7.92) CLEARANCE TOP AND BOTTOM 3.750 (95.25) 4.00 (101.6) 0.15 (3.8) 0.125 (3.17) 0.20 (5.1) 0.20 (5.1) .25 FASTON GROUND TAB J1 1.75 (44.45) 0.12 (3.18) 2.00 (50.8) Voltage Adjust 1.28 (32.5) N L Mechanical Details Derating Curve - ECS130 Models Notes 1. A ll dim ensions in inches (m m ). 2. W eight: 0.386 lbs (17 5 g) J1 m ates w ith M olex H ousing P N 09 -50-1031, J2 m ates w ith M olex H ousing P N 09 -50-104 1 and both w ith M olex Series 519 4 C rim p T erm inals Notes In put C onnector J1 M olex PN 09-65-2 038 P in 1 L ine P in 2 N eutral 0.25” Faston Earth O utput C onnector J2 M olex PN 09-65-2 04 8 P in 1 +V1 P in 2 +V1 P in 3 RTN P in 4 RTN 1. For covered versions, add suffix ‘-C ’ to m odel num ber or order part no. EC M 40/60 C O VER K IT for standalone cover, see derating curve. The cover is not suitable for C lass II installations. ‘-C ’. O utput Pow er O utput Voltage O utput C urrent M odel N um ber (1) Forced C ooled (10 C FM ) C onvection-cooled 130 W 100 W 12.0 VDC 10.9 A EC S130U S12 130 W 100 W 15.0 VDC 8.7 A EC S130U S15 130 W 100 W 18.0 VDC 7 .3 A EC S130U S18 130 W 100 W 24 .0 VDC 5.4 A EC S130U S24 130 W 100 W 28.0 VDC 4 .7 A EC S130U S28 130 W 100 W 4 8.0 VDC 2.7 A EC S130U S4 8 Ambient Temperature (º C) Output Power (W) 100 110 120 130 80 100 90 264 Input Voltage (VAC) Output Power (W) Forced-cooled >10 CFM Convection-cooled Convection-cooled with cover 100 110 120 130 -40 0-20 60 50 70 Forced-cooled >10 CFM Convection-cooled Convection-cooled with cover Some specification parame ters may not be met
Thermal Considerations - All Models Covered Version (not available for ECS100-B Models) Notes 1. A ll dim ensions in inches (m m ). 2. W eight: 0.8 lbs (360 g) In order to ensure safe and reliable operation of the P SU in the m ost adverse conditions perm itted in the end-use equipm ent, the tem perature of the com ponents listed in the table below m ust not be exceeded. See m echanical draw ing for com ponent locations. T em perature should be m onitored using K type therm ocouples placed on the hottest part of the com ponent (out of any direct air flow ). Tem perature M easurem ents (Am bient ≤ 50 °C ) C om ponent M ax Tem perature °C T1 110 °C C 5 100 °C C 4 100 °C Q 1 110 °C Input Connector Output Connector 0.25 (0.6) Ground Faston Terminal 4.49 (114.0) 2.52 (64.0) 1.54 (39.0) 2 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration 0.807 (20.50) 4.055 (103.00) 0.22 (5.5) 0.79 (20.0) 4 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration 4.055 (103.00) 0.984 (25.00) 0.22 (5.5) AC-DC ECS65/100/130 Mechanical Details 16-Aug-16