- Safety approvals cover frequency 47 -6 3 H z. 2. EC S6 0U S12 1.5 % pk-pk, 20 M H z bandw idth under certain line/load conditions. 3. See longform datasheet or contact sales for details. AC-DC Specification 25-60 Watts
- IT & Medical Safety Approvals
- Very Small 2 ”x 3 ”x 0.95 ”Package
- <0.3 W No Load Input Power
- 25, 45 & 60 W - Convection Cooled Ratings
- Class I & Class II Installations
- -20 °C to +70 °C Operation
- 3 Year Warranty ECS Series Input Input Voltage • 80-264 VA C (120-37 0 VDC ), derate linearly from 100% at 9 0 VA C to 80% at 80 VA C Input Frequency • 4 7 -4 00 H z (1) Input C urrent • 25 W : 0.4 5 A , 4 5 W : 0.7 5 A , 60 W : 0.9 5 A typical at 115 VA C , full load, 25 W : 0.30 A , 4 5 W : 0.4 5 A , 60 W : 0.60 A , typical at 230 VA C , full load Inrush C urrent • 4 0 A m ax at 230 VA C , cold start 25 ˚C Pow er Factor • EN 61000-3-2, class A N o Load Input Pow er • U S05, 12 & 24 m odels: <0.3 W , U S4 8 and all EC S60 m odels: <0.5 W Earth Leakage C urrent • 260 µA at 264 VA C /60 H z m ax, 80/160 µA typical 115/230 VA C Input Protection • T3.15 A /250 V internal fuse in line and neutral Output O utput Voltage • 5-4 8 VDC (see tables) O utput Voltage Trim • ±10% Initial Set Accuracy • ±1% M inim um Load • N o m inim um load required Start U p D elay • 1 s typical Start U p R ise Tim e • 50 m s H old U p Tim e • 16 m s m in at 115 VA C D rift • ±0.2% after 20 m in w arm up Line R egulation • ±0.5% m ax Load R egulation • ±1% O ver/U ndershoot • 5% typical Transient R esponse • 4 % m ax. deviation, recovery to w ithin 1% in 500 µs for a 50-7 5-50% load change R ipple & N oise • 1% pk-pk V1, 20 M H z bandw idth (2) O vervoltage Protection • 115-14 0% Vnom , recycle input to reset O verload Protection • 110-160% Short C ircuit Protection • C ontinuous trip and restart (hiccup m ode) Tem perature • 0.05% /˚C C oefficient xppow er.com General Efficiency • U p to 9 0% , m odel dependant Isolation • 4 000 VA C In to O ut, 2 x M O PP , 1500 VA C In to Earth, 1 x M O PP , 500 VDC O ut to Earth, 1 x M O PP Sw itching Frequency • 65 KH z typical Pow er D ensity • U p to 7 .9 W /in 3 M TB F • 25 & 4 5 W : 107 2 kH rs, 60 W : 4 7 1 kH rs to M IL-H DBK-217 F at 25 ˚C , G B Environmental O perating Tem perature • -20 ˚C to +7 0 ˚C derate linearly from +50 ˚C at 2.5% /˚C to 50% load at +7 0 ˚C . C ooling • C onvection, see therm al considerations O perating H um idity • 9 5% R H , non-condensing Storage Tem perature • -4 0 ˚C to +85 ˚C O perating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rm s, 5 H z to 500 H z, 3 axes EMC & Safety Low Voltage PSU EM C • EN 61204 -3, high severity level Em issions • A ll m odels: EN 55011/22 level B conducted. 4 5 & 60 W : EN 55011/22 level A radiated, EC S25 & EC S60U S24 /4 8 m odels: level B radiated H arm onic C urrents • EN 61000-3-2, class A Voltage Flicker • EN 61000-3-3 R adiated Im m unity • EN 61000-4 -3, level 3 Perf C riteria A EFT/B urst • EN 61000-4 -4 , level 3 Perf C riteria A Surge • EN 61000-4 -5, installation class 3 Perf C riteria A C onducted Im m unity • EN 61000-4 -6, level 3 Perf C riteria A D ips & Interruptions • EN 61000-4 -11 , 30% 10 m s, 60% 100 m s, 100% 5000 m s, Perf C riteria A , B, B , EN 60601-1-2, 30% 500 m s, 60% 100 m s, 100% 10 m s, 100% 5000 m s, Perf C riteria A , A , A , B - 230 VA C . C onsult longform datasheet for 115 V operation. Safety Approvals • IEC 609 50-1 C B report, U L609 50-1, TU V EN 609 50-1, IEC 60601-1 C B report, A N SI/A A M I ES60601-1, TU V 60601-1, Including R isk M anagem ent Equipm ent Protection • C lass I and C lass II C lass
0.95 (24.2) 0.14 (3.6) SMD Height 1.75 (44.4) 0.25 (0.6) Faston Ground Tab 1.65 (41.8) 1.31 (33.3) 3.00 (76.2) 2.00 (50.8) 0.27 (7.0) 0.20 (5.1) C5 C18 2.75 (69.8) 4 x Ø .156 (3.96) Mounting Holes Ø.3 12 (7.92) Clearance Top and Bottom ECS25 Models and Ratings Mechanical Details Notes 1. A ll dim ensions in inches (m m ). 2. W eight 0.22 lbs (100 g) Notes 1. A ll dim ensions in inches (m m ). 2. W eight 0.5 lbs (230 g) Notes 1. For covered versions, add suffix ‘-C ’ to m odel num ber or order part num ber EC S25 -6 0 C O VER KIT for standalone cover. N ot suitable for use in class II installations, derate output pow er by 20% w ith cover. O utput Pow er O utput Voltage O utput C urrent M odel N um ber (1) 25 W 12.0 VDC 2.08 A EC S25U S12 25 W 15.0 VDC 1.67 A EC S25U S15 25 W 24 .0 VDC 1.04 A EC S25U S24 25 W 4 8.0 VDC 0.52 A EC S25U S4 8 J1 m ates w ith M olex H ousing PN 09 -50-1031, J2 m ates w ith M olex H ousing PN 09 -50-104 1 and both w ith M olex Series 519 4 C rim p T erm inals In put C onnector J1 M olex PN 09-65-2 038 Pin 1 Line Pin 2 N eutral 0.25” Faston Earth O utput C onnector J2 M olex PN 09-65-2 04 8 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN 1.40 (35.6) 0.70 (17.79) 1.23 (31.28) 0.22 (5.7) 3.48 (88.4) 3.03 (76.9) 1 4 Output Connector 12 J1 Input Connector Top View 0.63 (16.0) 0.22 (5.7) 3.03 (76.99) 1.26 (32.0) 2.52 (64.0) Bottom View 4 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration 4 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration 0.25 (0.6) Faston Ground Tab Covered version (All ECS25-60 Models)
- For covered versions, add suffix ‘-C ’ to m odel num ber or order part num ber EC S25 -6 0 C O VER KIT for standalone cover. N ot suitable for use in class II installations, derate output pow er by 20% w ith cover. Notes AC-DC O utput Pow er O utput Voltage O utput C urrent M odel N um ber (1) 30 W 5.0 VDC 6.00 A EC S4 5U S05 4 5 W 12.0 VDC 3.7 5 A EC S4 5U S12 4 5 W 15.0 VDC 3.00 A EC S4 5U S15 4 5 W 24 .0 VDC 1.9 0 A EC S4 5U S24 4 5 W 4 8.0 VDC 0.9 5 A EC S4 5U S4 8 J1 m ates w ith M olex H ousing PN 09 -50-1031, J2 m ates w ith M olex H ousing PN 09 - 50-104 1 and both w ith M olex Series 519 4 C rim p T erm inals In put C onnector J1 M olex PN 09-65-2 038 Pin 1 Line Pin 2 N eutral 0.25” Faston Earth O ut put C onnector J2 M olex PN 09-65-2 04 8 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN J1 m ates w ith M olex H ousing PN 09 -50-1031, J2 m ates w ith M olex H ousing PN 09 -50-104 1 and both w ith M olex Series 519 4 C rim p T erm inals In put C onnector J1 M olex PN 09-65-2 038 Pin 1 Line Pin 2 N eutral 0.25” Faston Earth O ut put C onnector J2 M olex PN 09-65-2 04 8 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN 0.14 (3.6) SMD Height Limit 2.75 (69.9) 1.75 (44.5) 0.25 (0.6) Faston Ground Tab 1.58 (40.3) 1.30 (33.0) 3.00 (76.2) 0.28 (7.0) 0.20 (5.1) 1.05 (26.7) 2.00 (50.8) C18 4 x Ø.156 (3.96) Mounting H oles Ø .312 (7.92) Clearance Top and Bottom 0.95 (24.2) 0.14 (3.6) SMD Height 2.75 (69.9) 1.75 (44.5) 1.65 (41.8) 1.31 (33.3) 3.00 (76.2) 2.00 0.28 (7.0) 0.20 (5.1) C5 C18 0.25 (0.6) Faston Ground Tab 4 x Ø.156 (3.96) Mounting H oles Ø .312 (7.92) Clearance Top and Bottom (50.8 )
5 V version
- A ll dim ensions in inches (m m ). 2. W eight 0.22 lbs (100 g)
J1 m ates w ith M olex H ousing PN 09 -50-1031 J2 m ates w ith M olex H ousing PN 09 -50-104 1 and both w ith M olex Series 519 4 C rim p T erm inals In put C onnector J1 M olex PN 09-65-2 038 Pin 1 Line Pin 2 N eutral 0.25” Faston Earth O ut put C onnector J2 M olex PN 09-65-2 04 8 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN 1.05 (26.7) 0.14 (3.5) Components may extend beyond edge of PCB by 0.04 (1.0) J2 1 1.62 (41.1) 1.30 (33.0) 0.20 (5.1) C5 C18 0.28 (7.1) A A 4 x ø0.156 (3.96) mounting holes ø3.12 (7.92) clearance top and bottom 3.00 (76.2) 1.75 (44.4) 0.12 (3.18) 2.00 (50.8) 2.75 (69.8) 0.12 (3.1) Mounting points A should be connected together for optimum EMI performance 0.25 faston ground tab Mechanical Details 1. For covered versions, add suffix ‘-C ’ to m odel num ber or order part num ber EC S25 -6 0 C O VER KIT for standalone cover. N ot suitable for use in class II installations, derate output pow er by 20% w ith cover. Notes O utput Pow er O utput Voltage O utput C urrent M odel N um ber (1) 4 0 W 5.0 VDC 8.00 A EC S60U S05 60 W 12.0 VDC 5.00 A EC S60U S12 60 W 15.0 VDC 4 .00 A EC S60U S15 60 W 24 .0 VDC 2.50 A EC S60U S24 60 W 4 8.0 VDC 1.25 A EC S60U S4 8 Thermal Considerations (All ECS25-60 Models) In order to ensure safe and reliable operation of the PSU in the m ost adverse conditions perm itted in the end-use equipm ent, the tem perature of the com ponents listed in the table m ust not be exceeded. See m echanical draw ings for com ponent locations. T em perature should be m onitored using K type therm ocouples placed on the hottest part of the com ponent (out of any direct air flow ). Tem perature M easurem ents (Am bient ≤50 °C ) C om ponent M ax Tem perature ºC T1 110 °C Q 1 110 °C C 5 100 °C C 18 100 °C Notes 1. A ll dim ensions in inches (m m ). 2. W eight: 0.22 lbs (100 g)