  1. ECS60US12 1.5% pk-pk, 20 MHz bandwidth under certain line/load conditions. 2. See longform datasheet or contact sales for details. AC-DC Specification 25-60 Watts
  • IT & Medical Safety Approvals
  • Very Small 2” x 3” x 0.95” Package
  • <0.3 W No Load Input Power
  • 25, 45 & 60 W - Convection Cooled Ratings
  • Class I & Class II Installations
  • -20 °C to +70 °C Operation
  • 3 Year Warranty ECS Series Input Input Voltage • 80-264 VAC (120-370 VDC), derate linearly from 100% at 90 VAC to 80% at 80 VAC Input Frequency • 47-63 Hz Input Current • 25 W: 0.45 A, 45 W: 0.75 A, 60 W: 0.95 A typical at 115 VAC, full load, 25 W: 0.30 A, 45 W: 0.45 A, 60 W: 0.60 A, typical at 230 VAC, full load Inrush Current • 40 A max at 230 VAC, cold start 25 ˚C Power Factor • EN61000-3-2, class A No Load Input Power • US05, 12 & 24 models: <0.3 W, US48 and all ECS60 models: <0.5 W Earth Leakage Current • 260 μA at 264 VAC/60 Hz max, 80/160 μA typical 115/230 VAC Input Protection • T3.15 A/250 V internal fuse in line and neutral Output Output Voltage • 5-48 VDC (see tables) Output Voltage Trim • ±10% Initial Set Accuracy • ±1% Minimum Load • No minimum load required Start Up Delay • 1 s typical Start Up Rise Time • 50 ms Hold Up Time • 16 ms min at 115 VAC Drift • ±0.2% after 20 min warm up Line Regulation • ±0.5% max Load Regulation • ±1% Over/Undershoot • 5% typical Transient Response • 4% max. deviation, recovery to within 1% in 500 μs for a 50-75-50% load change Ripple & Noise • 1% pk-pk V1, 20 MHz bandwidth(1) Overvoltage Protection • 115-140% Vnom, recycle input to reset Overload Protection • 110-160% Short Circuit Protection • Continuous trip and restart (hiccup mode) Temperature • 0.05%/˚C Coefficient xppower.com General Efficiency • Up to 90%, model dependant Isolation • 4000 VAC In to Out, 2 x MOPP , 1500 VAC In to Earth, 1 x MOPP , 500 VDC Out to Earth, 1 x MOPP Switching Frequency • 65 KHz typical Power Density • Up to 7 .9 W/in3 MTBF • 25 & 45 W: 1072 kHrs, 60 W: 471 kHrs to MIL-HDBK-217F at 25 ˚C, GB Environmental Operating Temperature • -20 ˚C to +70 ˚C derate linearly from +50 ˚C at 2.5%/˚C to 50% load at +70 ˚C. Cooling • Convection, see thermal considerations Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes EMC & Safety Low Voltage PSU EMC • EN61204-3, high severity level Emissions • All models: EN55011/32 level B conducted. 45 & 60 W: EN55011/32 level A radiated, ECS25 & ECS60US24/48 models: level B radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, installation class 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions • EN61000-4-11 , 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B , EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation. Safety Approvals • IEC60950-1:2005 Ed 2 / IEC62368-1:2014 UL 62368-1 & CAN/CSA C22.2 No. 62368- 1-14, EN62368-1:2014/A11:2017 , IEC60601-1 CB report, ANSI/AAMI ES60601-1, TUV 60601-1, Including Risk Management, CE & UKCA meets all applicable directives & legislation. Equipment Protection • Class I and Class II Class

0.95 (24.2) 0.14 (3.6) SMD Height 1.75 (44.4) 0.25 (0.6) Faston Ground Tab 1.65 (41.8)1.31 (33.3) 3.00 (76.2) 2.00 (50.8) 0.27 (7.0) 0.20 (5.1) C5 C18 2.75 (69.8) 4 x Ø.156 (3.96) Mounting Holes Ø.312 (7.92) Clearance Top and Bottom ECS25Models and Ratings Mechanical Details Notes 1. All dimensions in inches (mm). 2. Weight 0.22 lbs (100 g) Notes 1. All dimensions in inches (mm). 2. Weight 0.5 lbs (230 g) Notes 1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations, derate output power by 20% with cover. Output Power Output Voltage Output Current Model Number(1) 25 W 12.0 VDC 2.08 A ECS25US12 25 W 15.0 VDC 1.67 A ECS25US15 25 W 24.0 VDC 1.04 A ECS25US24 25 W 48.0 VDC 0.52 A ECS25US48 J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp T erminals Faston ground tab requires insolated receptacle In put Connector J1 Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth Output Connector J2 Molex PN 09-65-2048 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN 1.40 (35.6) 0.70 (17.79) 1.23 (31.28) 0.22 (5.7) 3.48 (88.4) 3.03 (76.9) 1 4 Output Connector 12 J1 Input Connector Top View 0.63 (16.0) 0.22 (5.7) 3.03 (76.99) 1.26 (32.0) 2.52 (64.0) Bottom View 4 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration 4 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration 0.25 (0.6) Faston Ground Tab Covered version (All ECS25-60 Models)

  1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations, derate output power by 20% with cover. Notes AC-DC Output Power Output Voltage Output Current Model Number(1) 30 W 5.0 VDC 6.00 A ECS45US05 45 W 12.0 VDC 3.75 A ECS45US12 45 W 15.0 VDC 3.00 A ECS45US15 45 W 24.0 VDC 1.90 A ECS45US24 45 W 48.0 VDC 0.95 A ECS45US48 J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp T erminals Faston ground tab requires insolated receptacle In put Connector J1 Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth Out put Connector J2 Molex PN 09-65-2048 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series

5194 Crimp T erminals

Faston ground tab requires insolated receptacle In put Connector J1 Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth Out put Connector J2 Molex PN 09-65-2048 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN 0.14 (3.6) SMD Height Limit 2.75 (69.9) 1.75 (44.5) 0.25 (0.6) Faston Ground Tab 1.58 (40.3) 1.30 (33.0) 3.00 (76.2) 0.28 (7.0) 0.20 (5.1) 1.05 (26.7) 2.00 (50.8) C18 4 x Ø.156 (3.96) Mounting Holes Ø.312 (7.92) Clearance Top and Bottom 0.95 (24.2) 0.14 (3.6) SMD Height 2.75 (69.9) 1.75 (44.5) 1.65 (41.8) 1.31 (33.3) 3.00 (76.2) 2.00 0.28 (7.0) 0.20 (5.1) C5 C18 0.25 (0.6) Faston Ground Tab 4 x Ø.156 (3.96) Mounting Holes Ø.312 (7.92) Clearance Top and Bottom (50.8 )

5 V version

  1. All dimensions in inches (mm). 2. Weight 0.22 lbs (100 g)

27 July 2022

J1 mates with Molex Housing PN 09-50-1031 Faston ground tab requires insolated receptacle J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp T erminals Faston ground tab requires insolated receptacle In put Connector J1 Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth Out put Connector J2 Molex PN 09-65-2048 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN 1.05 (26.7) 0.14 (3.5)Components may extend beyond edge of PCB by 0.04 (1.0) J21 1.62 (41.1)1.30 (33.0) 0.20 (5.1) C5 C18 0.28 (7.1) A A 4 x ø0.156 (3.96) mounting holes ø3.12 (7.92) clearance top and bottom 3.00 (76.2) 1.75 (44.4) 0.12 (3.18) 2.00 (50.8) 2.75 (69.8)0.12 (3.1) Mounting points A should be connected together for optimum EMI performance 0.25 faston ground tab Mechanical Details 1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations, derate output power by 20% with cover. Notes Output Power Output Voltage Output Current Model Number(1) 40 W 5.0 VDC 8.00 A ECS60US05 60 W 12.0 VDC 5.00 A ECS60US12 60 W 15.0 VDC 4.00 A ECS60US15 60 W 24.0 VDC 2.50 A ECS60US24 60 W 48.0 VDC 1.25 A ECS60US48 Thermal Considerations (All ECS25-60 Models) In order to ensure safe operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of the components listed in the table must not be exceeded. See mechanical drawings for component locations. T emperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). Temperature Measurements (Ambient ≤50 °C) Component Max Temperature ºC T1 120 °C Q1 110 °C C5 105 °C C18 105 °C Notes 1. All dimensions in inches (mm). 2. Weight: 0.22 lbs (100 g)