DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 21

Technical content

Approved for Class I and Class II applications, the ECM range of single and multiple output AC-DC, 40-60 W power supplies from XP feature the world's smallest footprint for units of these ratings. Both are just 2" x 4" (50.8 mm x 101.6 mm) and 1.2" (30.48 mm) high. Furthermore, these high-density power supplies meet EN55022 Level B conducted emissions with maximum leakage currents of 100 µA at 115 VAC or 200 µA at 230 VAC. As a result, these switchers are equally suitable for industrial, IT and medical applications, with no price premium for meeting medical requirements. The ECM40-60 series have single output versions from 5 V to 48 VDC, adjustable by ±10%, and dual and triple output versions covering combinations of 3.3 V , 5 V , 12 V , 15 V and 24 V . They are dual-fused for compliance with IEC60601-1 and efficiency is 80-85%, depending upon the model, so minimal excess heat is generated. The power supplies deliver full power between 0 °C and +50 °C and will operate at up to +70 °C with derating and only 5 CFM of cooling. Comprehensive overvoltage, overload and short circuit protection is built in. Covers, looms and connector kits are available. EC M 40-60

  • 40 & 60 Watt Models
  • Small Size 2.0”x 4.0”x 1.2”
  • Low Leakage Current
  • Industrial & Medical Approvals
  • Full Load Available Convection Cooled
  • Wide Operating Temperature 0 °C to +70 °C
  • Level B Conducted Emissions
  • EN61000 Compliant
  • Universal AC Input 90-264 VAC
  • Input Frequency 47-63 & 440 Hz
  • Single & Multiple Outputs
  • Cover Kits Available
  • Mating Connector & Loom Kits Available

xppow er.com G eneral Specifications Input C haracteristics C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input Voltage - Operating 90 264 VAC 120-370 VDC Input Frequency 47 50/60 63 Hz 400 Hz operation available Input Current - No load 41 mA 230 VAC Input Current - Full load 1.38 A 90 VAC Inrush Current 40 A Cold start at 230 VAC Power Factor 0.62 230 VAC Earth Leakage Current 290 µA 264 VAC Input Protection T3.15 A/ 250 V internal fuse in line & neutral C haracteristic M inim um Typical M axim um U nits N otes & C onditions Efficiency 70 % (at 230 VAC full load) 3.3 & 5 V single output versions

80 All other single output versions

75 Dual output versions

1500 Input to ground

500 Output to ground

Switching Frequency 70 kHz Fixed Power Density 6.25 W/In 3 For 60 W version Weight 0.33 (150) lbs (g) MTBF 600 kHrs Mil HDBK 217F O utput C haracteristics C haracteristic M inim um Typical M axim um U nits N otes & C onditions Output Voltage 5.0 48.0 VDC See modules table Initial Set Accuracy V1: ±1, V 2 & V 3: ±5 % Output Voltage Trim ±10 %V 1 (V 2 will track V 1 by the same %) Minimum load V1: 0.5, V 2: 0.1 A Not required on single output models Start Up Delay 1.5 s 90 VAC Start Up Rise Time 10 ms Hold Up Time 16 75 ms 115-230 VAC input Drift ±0.2 % Line Regulation ±0.5 % 90-264 VAC Load Regulation ±1.0 % Single output V1: ±3, V 2 & V 3: ±5 % Dual output Transient Response 4% Output voltage recovers to within 1% in less than 500 µs for 50% load change. Ripple & Noise 1 %pk-pk 20 MHz bandwidth Overvoltage Protection 115 135 VDC Recycle input to reset Overload Protection 110 170 % Imax Auto-recovery Short Circuit Protection Trip & restart (hiccup mode) Temperature Coefficient 0.05 %/ºC All specifications are at nominal input, full resistance load at 25°C unless otherwise stated.

xppow er.com Environm ental C haracteristic M inim um Typical M axim um U nits N otes & C onditions Operating Temperature -0 +70 ºC See derating curves Storage Temperature -40 +85 ºC Cooling 0 CFM Convection-cooled Operating Humidity 95 % RH Non- condensing Operating Altitude 3000 m Shock 30 Gpk Half sine 6 axis Vibration 2G 5-500 Hz 3 axis Electrom agnetic C om patibility & Im m unity Standard Test Level C riteria N otes & C onditions Emissions EN55022 Class B Conducted EN55022 Class A Radiated EN60601-1-2 Class B Conducted Harmonic Currents EN61000-3-2 Voltage Flicker EN61000-3-3 ESD Immunity EN61000-4-2 level 2, performance criteria A Radiated Immunity EN61000-4-3 10 V/m, performance criteria A EFT/Burst EN61000-4-4 level 2, performance criteria A Surge EN61000-4-5 level 3, performance criteria A Conducted Immunity EN61000-4-6 10 Vrms, performance criteria A Dips & Interruptions EN61000-4-11 70% U T : performance criteria A For 10 ms, 100% load 40% U T : performance criteria B For 100 ms, 100% load 0% U T : performance criteria B For 5000 ms, 100% load Dips & Interruptions EN61000-4-11 (Medical) 70% Ut, performance criteria A For 500 ms, Medical, 100% load 40% Ut, performance criteria A For 100 ms, Medical, 60% load 0% Ut, performance criteria A For 10 ms, Medical, 100% load 0% Ut, performance criteria B For 5000 ms, Medical, 100% load Safety Approvals Safety Agency Safety Standard Category CB Report Certificate # US/12606 & 12607/UL IEC60950-1:2005 Ed 2 Information Technology UL UL File #E139109-A62-UL UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology TUV TUV Certificate # B08 07 57396 052 & B09 03 57396 058, EN60950-1:2004 Information Technology CE LVD Safety Agency Safety Standard Category CB Report Certificate #US/18293 & 18269/UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV TUV Certificate # B12 01 57396 125, EN60601-1:2006 Medical Equipment Protection Class Safety Standard Notes & Conditions Class I & Class II IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3 See safety agency conditions of acceptability for details Means of Protection Category Primary to Secondary 1 x MOPP (Means of Patient Protection) Contact Sales for 2 x MOPP IEC60601-1 Ed 3 Primary to Earth 1 x MOPP (Means of Patient Protection)

M odels & R atings xppow er.com M ax Pow er O utputs M odel N um ber V1 Im in/Im ax (3) V2 Im in/Im ax V3 Im in/Im ax 4 0 W 5.0 V 0.0 A / 8.0 A EC M 4 0U S05 †* 7 .0 V 0.0 A / 5.7 A EC M 4 0U S07 9.0 V 0.0 A / 4 .4 A EC M 4 0U S09 * 1 2.0 V 0.0 A / 3.5 A EC M 4 0U S1 2 †* 1 5.0 V 0.0 A / 2.7 A EC M 4 0U S1 5 †* 1 8.0 V 0.0 A / 2.2 A EC M 4 0U S1 8 24 .0 V 0.0 A / 1 .7 A EC M 4 0U S24 †* 33.0 V 0.0 A / 1 .2 A EC M 4 0U S33 4 8.0 V 0.0 A / 0.9 A EC M 4 0U S4 8 †* N otes 1. V2 will track a change in V1 by the same percentage change in voltage as V1 is trimmed. 2. To receive unit with cover fitted, add suffix ‘-C’ to model number. For Class I operation only. 3. A 120% peak load can be taken for up to 100 ms with a 25% duty cycle. Average load not to exceed maximum power rating. † Available from F arnell InO ne. * Available from N ew ark InO ne. M ax Pow er O utputs M odel N um ber V1 Im in/Im ax (3) V2 Im in/Im ax V3 Im in/Im ax 6 0 W 5.0 V 0.0 A / 1 2.00 A EC M 6 0U S05 †* 7 .0 V 0.0 A / 8.6 0 A EC M 6 0U S07 9.0 V 0.0 A / 6 .70 A EC M 6 0U S09 * 1 2.0 V 0.0 A / 5.00 A EC M 6 0U S1 2 †* 1 5.0 V 0.0 A / 4 .00 A EC M 6 0U S1 5 †* 1 8.0 V 0.0 A / 3.30 A EC M 6 0U S1 8 20.0 V 0.0 A / 3.00 A EC M 6 0U S20 24 .0 V 0.0 A / 2.50 A EC M 6 0U S24 †* 28.0 V 0.0 A / 2.1 4 A EC M 6 0U S28 33.0 V 0.0 A / 1 .80 A EC M 6 0U S33 4 8.0 V 0.0 A / 1 .25 A EC M 6 0U S4 8 †*

xppow er.com Transient R esponse Therm al D erating C urves 20 10 30 40 50 60 70 80 0 % 50% 100% Output Power Ambient Temp (°C) 75% 25% 20 10 30 40 50 60 70 80 0 % 50% 100% Output Power Ambient Temp (°C) 75% 25% N ote: D erate by 1 0% if cover is fitted All EC M 40 m odels convection-cooled All EC M 40 m odels w ith 5 C FM 20 10 30 40 50 60 70 80 0 % 75% Output Power Ambient Temp (°C) 100% 25% 50% 20 10 30 40 50 60 70 80 0 % 50% 100% Output Power Ambient Temp (°C) 75% 25% N ote: D erate by 1 0% if cover is fitted All EC M 6 0 m odels convection-cooled All EC M 6 0 m odels w ith 5 C FM EC M 6 0U S24 25% load change

xppow er.com Efficiency Versus Input Voltage EC M 6 0U S24 w ith 6 0 W load EC M 6 0U T33 w ith 50 W load Efficiency Versus O utput Load EC M 6 0U S24 at 230 VAC input EC M 6 0U T33 at 230 VAC input

xppow er.com Start U p D elay EC M 6 0U S24 w ith 6 0 W load EC M 6 0U S24 w ith 6 0 W load at 230 VAC EC M 6 0U T33 w ith 6 0 W load H old U p Tm e O verload C haracteristics EC M 6 0U S24. W hen current reaches 5.4 A, output goes into trip and restart (hiccup) m ode

xppow er.com R ipple & N oise EC M 6 0U S24 w ith 6 0 W load N oise m easured is 6 4 m V pk-pk EC M 6 0U T33 output 1 w ith 30 W load. N oise m easured is 36 m V pk-pk EC M 6 0U T33 output 2 w ith 1 5 W load. N oise m easured is 6 8 m V pk-pk EC M 6 0U T33 output 3 w ith 7 W load. N oise m easured is 34 m V pk-pk

xppow er.com C onducted N oise EC M 6 0U S24 at full load EC M 6 0U T33 at full load

xppow er.com 1 0 M echanical D etails - Single O utput M odels Therm al C onsiderations 4X ø0.156 (3.96) mounting holes ø0.312 (7.92) clearance top and bottom SMD component height V Adj. 1.20 (30.5) 0.14 (3.5) 4.00 (101.6) 2.00 (50.8) 1.75 (44.45) 3.75 (95.25) 1 J2 CR2 0.25 x 0.32 faston ground tab W eight: approx. 0.33 lb (1 50g) O utput C onnector J2 Pin Single 1 +V1 2 +V1

3 RTN

4 RTN

5 N .C . 6 N .C . C om ponent M axim um Tem perature L1 1 1 0 °C T1 1 1 0 °C C R 2 1 20 °C C 4 95 °C N otes 2. C able harnesses w ith 300m m w ire available. F or single output m odels, order part num ber EC M 4 0/6 0S LO O M . F or m ulti-output m odels, order part num ber EC M 4 0/6 0D T LO O M . 3. M ating connector kit available. O rder part num ber EC M 4 0/6 0 C O N KIT . 5. † All accessories available from F arnell InO ne. In put C onnector J1 Pin 1 Line Pin 2 N eutral J1 m ates w ith M olex housing 4 306 1 -0003 and M olex series 51 94 crim p term inals. G round (0.25 faston) tab standard. T o ensure correct and reliable operation of the PSU , the tem perature of the com ponents listed in the table below m ust not be exceeded. See m echanical details for com ponent locations. J2 m ates w ith M olex housing 4 306 1 -0006 & M olex series 51 94 crim p term inals.

xppow er.com M echanical D etails - Single O utput M odels (3 x 5) Therm al C onsiderations W eight: approx. 0.4 lb (1 80 g) O utput C onnector J2 Pin Single 1 +V1 2 +V1 5 N .C . 6 N .C . C om ponent M axim um Tem perature L1 1 1 0 °C T1 1 1 0 °C C R 2 1 20 °C C 4 95 °C N otes 2. C able harnesses w ith 300m m w ire available. F or single output m odels, order part num ber EC M 4 0/6 0S LO O M . F or m ulti-output m odels, order part num ber EC M 4 0/6 0D T LO O M . 3. M ating connector kit available. O rder part num ber EC M 4 0/6 0 C O N KIT . 5. † All accessories available from F arnell InO ne. In put C onnector J1 Pin 1 Line Pin 2 N eutral J1 m ates w ith M olex housing 4 306 1 -0003 and M olex series 51 94 crim p term inals. G round (0.25 faston) tab standard. T o ensure correct and reliable operation of the PSU , the tem perature of the com ponents listed in the table below m ust not be exceeded. See m echanical details for com ponent locations. J2 m ates w ith M olex housing 4 306 1 -0006 & M olex series 51 94 crim p term inals. 4 x ø0.156 (3.96) Mounting Holes ø0.312 (7.92) Clearance Top & Bottom 0.25 (6.35) Faston Ground Tab, Optional 4.55 (115.57 5.00 (127.0) 2.55 (64.7) 3.00 (76.2) 0.14 (3.6), SMD Component Height 1.20 (30.5) 0.22 (5.71) 0.22 (5.71) NL 6 1

xppow er.com 1 2 M echanical D etails - M ulti O utput M odels Therm al C onsiderations 4X ø0.156 (3.96) mounting holes ø0.312 (7.92) clearance top and bottom SMD component height 1.20 (30.5) 0.14 (3.5) 4.00 (101.6) 2.00 (50.8) 1.75 (44.45) 3.75 (95.25) CR2 W eight: approx. 0.33 lb (1 50g) O utput C onnector J2 Pin Single 1 +V1 2 +V1 C om ponent M axim um Tem perature L1 1 1 0 °C T1 1 1 0 °C C R 2 1 20 °C C 4 95 °C N otes 2. C able harnesses w ith 300m m w ire available. F or single output m odels, order part num ber EC M 4 0/6 0S LO O M . F or m ulti-output m odels, order part num ber EC M 4 0/6 0D T LO O M . 3. M ating connector kit available. O rder part num ber EC M 4 0/6 0 C O N KIT . 5. † All accessories available from F arnell InO ne. In put C onnector J1 Pin 1 Line Pin 2 N eutral J1 m ates w ith M olex housing 4 306 1 -0003 and M olex series 51 94 crim p term inals. G round (0.25 faston) tab standard. T o ensure correct and reliable operation of the PSU , the tem perature of the com ponents listed in the table below m ust not be exceeded. See m echanical details for com ponent locations. J2 m ates w ith M olex housing 4 306 1 -0006 & M olex series 51 94 crim p term inals. 1 0-M ay-1 6

  • 100 Watt Models
  • Small Size 2.5” x 4.5” x 1.2”
  • Low Leakage Current
  • Industrial & Medical Approvals
  • Convection & Force Cooled Ratings
  • Wide Operating Temperature 0 °C to +70 °C
  • Level B Conducted Emissions
  • EN61000 Compliant
  • Universal AC Input 90-264 VAC
  • Input Frequency 47-63 & 440 Hz
  • Cover Kits Available
  • Mating Connector & Cable Harness Kits Available Approved for Class I and Class II applications, the ECM100 range of single output AC-DC, 100 W power supplies from XP feature t he Furthermore, these high-density power supplies meet EN55022 Level B conducted emissions with maximum leakage currents of 125 μA at 115 VAC or 210 μA at 230 VAC. As a result, these switchers are equally suitable for industrial, IT and medical applic ations, with no price premium for meeting medical requirements. The ECM100 series have single output versions from 3.3 V to 48 VDC, adjustable by ±10%. They are dual-fused for compliance with IEC60601-1 and efficiency is 80-85%, depending upon the model, so minimal excess heat is generated. The power supplies deliver full power between 0 °C and +50 °C and will operate at up to +70 °C with derating and only 5 CFM of cooling. Comprehensive overvoltage, overload and short circuit protection is built in. Covers, cable harnesses and connector kits are available.

xppower.com Input Characteristics Charactristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 90 264 VAC 120-370 VDC Input Frequency 47 50/60 63 Hz 400 Hz operation available Power Factor 0.62 230 VAC Input Current - No Load 40 mA 230 VAC Input Current - Full Load 0.9 A 230 VAC Inrush Current 40 A 230 VAC cold start Earth Leakage Current 125/210 μA 115/230 VAC Input Protection T3.15 A/250 V internal fuse in both line and neutral Output Characteristics Charactristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 3.3 48.0 VDC See Models and Ratings Table Initial Set Accuracy V 1: ±1. V2,V3 & V4: ±5 % Output Voltage Adjustment ±5 % 3.3 & 5 V versions ±10 All other versions Minimum Load A See model tables Start Up Delay 1.5 s 90 VAC Start Up Rise Time 50 ms Hold Up Time 16 75 ms 115-230 VAC input Drift ±0.2 % Line Regulation ±0.5 % 90-264 VAC Load Regulation ±1 % Single output versions V1 & V2: ±1. V3 & V4: ±5 Multi output versions Transient Response 4 % Recovery to within 1% in less than 500 μs for a 25% load change Ripple & Noise 1 %pk-pk 20 MHz bandwidth Overvoltage Protection 115 135 % V 1 only. Recycle input to reset Overload Protection 110 150 % Primary power limit, auto-recovery Short Circuit Protection Trip & restart (Hiccup mode) Temperature Coefficient 0.05 %/˚C General Specifications Characteristic Minimum Typical Maximum Units Notes & Conditions Reliability and Service Life Isolation Input to Output Test Voltage 4000 VAC Test duration: 1 min Input to Ground Test Voltage 1500 VAC Test duration: 1 min Output to Ground Test Voltage 500 VAC Test duration: 1 min Other Specifications Efficiency 80-85 % See Efficiency Graphs Switching Frequency 70 kHz Fixed Weight 0.4 (180) lb (g) Power Density 7.40 W/In MTBF 600 kHrs MIL HDBK 217F

xppower.com Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +70 ˚C See derating curves Storage Temperature -40 +85 ˚C Cooling 5 CFM For full power operation Humidity 95 %RH Non-condensing Operating Altitude 3000 m Shock 30 G peak Half sine 6 axis Vibration 2 G rms 5 Hz to 500 Hz, 3 axis Electromagnetic Compatibility - Emissions Electromagnetic Compatibility - Immunity Phenomenon Standard Test Level Criteria Notes & Conditions ESD EN61000-4-2 3 A EFT EN61000-4-4 3 A Radiated Field EN61000-4-3 10 V/m A Surges EN61000-4-5 3 A Conducted EN61000-4-6 10 Vrms A Dips and Interruptions EN61000-4-11 (Medical) 70% Ut A For 500 ms, Medical, 100% load 40% Ut A For 100 ms, Medical, 60% load 0% Ut A For 10 ms, Medical, 100% load 0% Ut B For 5000 ms, Medical, 100% load Dips and Interruptions EN61000-4-11 70% Ut A For 10 ms, 100% load 40% Ut B For 100 ms, 100% load <5% Ut B For 5000 ms, 100% load Phenomenon Standard Test Level Criteria Notes & Conditions Conducted EN55022/11 Class B Voltage Flicker EN61000-3-3 Harmonic Currents EN61000-3-2 Class A Safety Agency Approvals Safety Agency Safety Standard Category CB Report UL IEC60950-1:2005 Ed 2 Information Technology UL UL File #E139109 UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology TUV TUV EN60950-1:2004 Information Technology CE LVD Safety Agency Safety Standard Category CB Report UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV EN60601-1:2006 Medical Equipment Protection Class Safety Standard Notes & Conditions Class I & Class II IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 2 See safety agency conditions of acceptability for details Means of Protection Category Primary to Secondary (ECM100USxx Models) 2 x MOPP (Means of Patient Protection) IEC60601-1 Ed 3Primary to Secondary (ECM100UMxx Models) 1 x MOPP (Means of Patient Protection) Contact Sales for 2 x MOPP Primary to Earth 1 x MOPP (Means of Patient Protection)

All ECM100 single output models convection cooled xppower.com Models and Ratings Derating Curves 2010 30 40 50 60 70 80 100 Output Power (W) Ambient Temp (°C) A D C A B C D B US24-48 US12-18 US05 US03 Output Voltage Output Current Minimum Output Current Maximum Ripple & Noise Model NumberConvection cooled 5 CFM 3.3 V 0.0 A 15.0 A 20.0 A 50 mV ECM100US03 5.0 V 0.0 A 15.0 A 20.0 A 50 mV ECM100US05 7.0 V 0.0 A 11.4 A 14.3 A 70 mV ECM100US07 9.0 V 0.0 A 8.8 A 11.1 A 90 mV ECM100US09 12.0 V 0.0 A 7.5 A 8.3 A 120 mV ECM100US12 15.0 V 0.0 A 6.0 A 6.6 A 150 mV ECM100US15 18.0 V 0.0 A 5.0 A 5.5 A 180 mV ECM100US18 24.0 V 0.0 A 4.1 A 4.1 A 240 mV ECM100US24 28.0 V 0.0 A 3.6 A 3.6 A 280 mV ECM100US28 33.0 V 0.0 A 3.0 A 3.0 A 330 mV ECM100US33 48.0 V 0.0 A 2.1 A 2.1 A 480 mV ECM100US48 Notes Multi Output Models Single Output Models 1. To receive unit with cover fitted, add suffix ‘-C’ to model number. 2.Output 3 available with opposite polarity for OEM quant ities. Power Max Convection Power Max

5 CFM Output 1 Imin/Imax Output 2 Imin/Imax Output 3 Imin/Imax Output 4 Imin/Imax Model

All ECM100 models with 5 CFM 2010 30 40 50 60 70 80 50% 100%Output Power Ambient Temp (°C) 75% 25% Note: 1. Derate by 10% if cover is fitted. 2. For multi output convection- cooled operation above 50 °C derate linearly to 50% at 70 °C.

xppower.com Transient Response ECM100US24 25% load change Efficiency shown for ECM100US24 Efficiency shown for ECM100US24 Efficiency Versus Input Voltage 82% 83% 84% 85% 0 50 100 150 200 250 300 Input Voltage Efficiency % Efficiency Versus Output Load 10% 20% 30% 40% 50% 60% 70% 80% 90% 0 0.5 1 1.5 2 2.5 3 3.5 Output Load Efficiency %

ECM100US24 start up 115 VAC at 100% load ECM100US24 start up 230 VAC at 100% load xppower.com Start Up Delay Hold Up Time 012345678 Current A Voltage V ECM100US24. When current reaches 6.9 A, output goes into trip & restart (Hiccup mode) ECM100US24 hold up 115 VAC at 100% load Hold up time is 20.8 ms Overload Characteristics

xppower.com Output Ripple & Noise Conducted Noise ECM100US24 with 100 W load Noise measured is 28 mV ECM100US12 Class I - Output floating (full load) ECM100UQ44 Class I - Output floating (full load) ECM100US12 Class I - Output grounded (full load) ECM100UQ44 Class I - Output grounded (full load)

xppower.com Mechanical Details - Single Output Models Thermal Considerations 4X ø0.156 [3.96] mounting holes ø0.312 [7.92] clearance top and bottom SMD component height C12 CR3 0.25 (6.35) Faston ground tab 1.20 (30.5) 0.14 [3.5] 4.50 (114.3) 2.50 (63.5) 2.25 (57.15) 4.25 (107.95) Output Connector J2 Pin Single 1 +V1 2 +V1 3 +V1 4 +V1

5 V1 RTN

6 V1 RTN

7 V1 RTN

8 V1 RTN

9 NOT USED

10 NOT USED

11 NOT USED

12 NOT USED

Component Maximum Temperature L1 110 °C T1 110 °C CR3 120 °C C12 95 °C Notes 2. Cable harnessess with 300mm wire available. For single output models, order part number ECM100S LOOM. 3. Mating connector kit available. Order part number ECM100 CONKIT . 4. Covers available. Order part number ECM100 COVER. In put Connector J1 Pin 1 Line Pin 2 Neutral J1 mates with Molex housing 43061-0003 and Molex series 5194 crimp terminals. Ground (0.25 faston) tab standard. T o ensure correct and reliable operation of the PSU, the temperature of the components listed in the table below must not be exceeded. See mechanical details for component locations. J2 mates with Molex housing 43061-0012 & Molex series 5194 crimp terminals

xppower.com Thermal Considerations Component Maximum Temperature L1 110 °C T1 110 °C CR2 120 °C C17 95 °C Mechanical Details - Multi Output Models 4X ø0.156 [3.96] mounting holes ø0.312 [7.92] clearance top and bottom SMD component height C17 CR2 0.25 (6.35) Faston ground tab 1.20 (30.5) 0.14 [3.5] 4.50 (114.3) 2.50 (63.5) 2.25 (57.15) 4.25 (107.95) Output Connector J2 Pin Multi 1 +V1 2 +V1 3 +V1 4 +V1

5 RTN

6 RTN

7 RTN

8 RTN

11 ±V3 12 -V4 Notes 2. Cable harnessess with 300mm wire available. For multi output models (dual and triple output only), order part number ECM100D T LOOM. 3. Mating connector kit available. Order part number ECM100 CONKIT . 4. Covers available. Order part number ECM100 COVER. In put Connector J1 Pin 1 Line Pin 2 Neutral J1 mates with Molex housing 43061-0003 and Molex series 5194 crimp terminals. Ground (0.25 faston) tab standard. T o ensure correct and reliable operation of the PSU, the temperature of the components listed in the table below must not be exceeded. See mechanical details for component locations. J2 mates with Molex Housing 43061-0012 and Molex series 5194 crimp terminals 23-Sept-14