ECL10US03 XPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
10 Watts
- Ultra Compact Size
- Low Cost
- Single Outputs from 3.3 to 48 V
- PCB Mount & Open Frame
- Encapsulated PCB Mount
- Class II
- Peak Load Capability ECL10 Series Input Input Voltage • 85-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz Input Current • 0.20 A rms at 230 VAC Inrush Current • 20 A at 115 VAC, 40 A at 230 VAC, Earth Leakage Current• Class II construction no earth Input Protection • Internal 1 A fuse Output Output Voltage • See tables Output Voltage Trim • ±5% (not encapsulated units) Initial Set Accuracy • ±1% Minimum Load • No minimum load required Start Up Delay • 2 s max Start Up Rise Time • 14 ms max Hold Up Time • 16 ms typical at full load &115 VAC Line Regulation • ±0.5% max Load Regulation • ±1% max Transient Response • 4% max deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • 3.3-5 V versions: 50 mV pk-pk, 12-15 V versions: 120 mV pk-pk, 24-48 V versions: 200 mV pk-pk,
20 MHz BW
Overvoltage Protection• 115-135% Vnom, recycle input to reset Overload Protection • 120-150% Short Circuit Protection• Trip and restart (Hiccup mode) Temperature • 0.05%/°C Coefficient xppower.com General Efficiency • See tables Isolation • 3000 VAC Input to Output Switching Frequency • 70 kHz typical Power Density • 5.5 W/In3 (PCB mount version) MTBF • >450 kHrs per MIL-HDBK-217F Environmental Operating Temperature• -20 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C Cooling • Convection-cooled Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Operating Altitude • 3000 m Vibration • 2 g, 10 Hz to 500 kHz, 10 mins/cycle, 60 mins each cycle EMC & Safety Emissions • EN55022, level B conducted & radiated Harmonic Currents • EN61000-3-2, EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, 10 V/m 80% mod Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, 10 Vrms Perf Criteria A Magnetic Fields • EN61000-4-8, 10 A/m Perf Criteria A Dips & Interruptions • EN61000-4-11, 70% U T for 10 ms, 40% U T for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B Safety Approvals • EN60950, UL60950, CSA22.2 No. 234 per cUL
0.150 (3.80) 1.000 (25.40) 0.800 (20.32) 0.170 (4.40) 0.730 (18.46) 0.900 (22.86) 0.400 (10.16) 0.100 (2.54) 0.100 (2.54) 0.180 (45.72) 1.800 (45.72) ø 0.070 (ø1.80) ø 0.040 (ø1.00) 4 x ø 0.040 (ø1.00) 2.000 (50.80) 0.100 (2.54) +Vo -Vo V Adj. V Adj. ACN ACL Open Frame - PCB Mount (-P) Open Frame - Chassis Mount (-T) 2.600 (66.04) 2.285 (58.04) 4-ø0.126 (ø3.20) 0.157 (4.00) 0.727 (18.47) 0.850 (21.59) 0.157 (4.00) 0.685 (17.40) 1.000 (25.40) +Vo -VoACN ACL 1.070 (27.20) 0.130 (3.40) 0.130 (3.40) 0.910 (23.00) 0.390 (10.00) 2.060 (52.41) +Vo-Vo ACL ACN Encapsulated (-E) TOP VIEW Mechanical Details Models and Ratings Output Power Output Voltage Output Current Efficiency Model Number (2) Nominal Peak(1) 8.6 W 3.3 VDC 2.60 A 3.38 A 72% ECL10US03 ^† 10 W 5.0 VDC 2.00 A 2.60 A 75% ECL10US05 ^† 10 W 9.0 VDC 1.10 A 1.43 A 78% ECL10US09 ^† 10 W 12.0 VDC 0.83 A 1.08 A 78% ECL10US12 ^† 10 W 15.0 VDC 0.67 A 0.87 A 80% ECL10US15 ^† 10 W 24.0 VDC 0.42 A 0.55 A 82% ECL10US24 ^† 10 W 48.0 VDC 0.21 A 0.27 A 82% ECL10US48 ^† Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. Add suffix to model number to define type: add ‘-P’ for PCB mount, add ‘-T’ for chassis mount, add ‘-E’ for encapsulated. 1. Dimensions in inches (mm). Mating Connectors (Chassis mount only) Input Connector: JST PHR-3 Output Connector: JST PHR-2 Crimps: SPH-002T-P0.5S Cable harness with 300 mm wire available, order part no. ECL10 LOOM KIT † Available from Farnell. See pages 204-206. ^ Available from Newark. See pages 207-208. Notes