Technical content
- 40 W Convection Rating
- 1.5” by 3” Footprint
- Low 1.1” Profile
- H igh Efficiency
- M edical and ITE A pprovals
- H igh Pow er D ensity
- Less than 0.15 W N o Load Input Pow er
- 3 Year W arranty Dimensions: ECF40: w w w .xppow er.com 1 Models & Ratings N otes 1. T ypical efficiency m easured at full load and 230 VA C input. ECF40 Series AC -D C Pow er Supplies
40 W atts
O utput Pow er O utput Voltage O utput C urrent Efficiency (1) M odel N um ber 4 0 W 1 2.0 V 3.34 A 91 % EC F 4 0U S1 2 4 0 W 1 5 .0 V 2.67 A 92% EC F 4 0U S1 5 4 0 W 1 8.0 V 2.23 A 93% EC F 4 0U S1 8 4 0 W 24 .0 V 1 .67 A 91 % EC F 4 0U S24 4 0 W 36.0 V 1 .1 1 A 90% EC F 4 0U S36 4 0 W 4 8.0 V 0.83 A 90% EC F 4 0U S4 8 0.13 (3.18) 1.5 (38.1) 1.25 (31.57) Line Neutral 3.00 (76.2) Ø 0.14 (3.6) through in 4 positions Output Voltage Control -VE +VE Output Terminals 0.13 (3.18) 2.75 (69.85) 1.11 (28.14) Mechanical Details 1 . A ll dim ensions show n in inches (m m ). T olerance: ±0.02 (0.5 ) 2. W eight: 0.1 5 lbs (69 g) approx. N otes C N 2 - O utput C onnector Pin 1 +Vout Pin 2 -Vout M ates w ith J ST housing VH R -2N and J ST Series SVH -21 T -P1 .1 crim p term inals C N 1 - Input C onnector Pin 1 N eutral Pin 2 N ot F itted Pin 3 Line M ounting hole m arked w ith m ust be connected to safety earth for class I
applications
M ates w ith J ST housing VH R -3N and J ST Series SVH -21 T -P1 .1 crim p term inals The ECF40 series is designed to minimize the no load power consumption and maximize efficiency to facilitate equipment design to meet the latest environmental legislation. Approved for medical and ITE applications, this range of single output AC-DC power supplies are packaged in a low profile 1.1” height with a foot print of just 1.5” by 3”. The ECF40 provides up to 40W convection-cooled over the full 90-264 VAC input range, and operates down to 80 VAC with minimal de-rating. The power supply features two AC line fuses and low leakage currents required by medical applications. The low profile, low noise and safety approvals covering ITE and medical standards allows the versatile ECF40 series to be used in a wide range of applications.
C haracteristic M inim um Typical M axim um U nits N otes & C onditions O utput Voltage 1 2 4 8 VD C See M odels and R atings table Initial Set A ccuracy ±1 % 5 0% load, 1 1 5 /230 VAC O utput Voltage Adjustm ent 1 0 % M inim um Load 0A N o m inim um load required Start U p D elay 12s O utput R ise Tim e 5 0 m s H old U p Tim e 8.3/20 m s M in at full load 1 1 5 /230 VAC Line R egulation ±0.5 % 90-264 VAC Load R egulation 1% 0-1 00% load. T ransient R esponse 4% R ecovery w ithin 1 % in less than 5 00 µs for a 5 0-7 5 % and 7 5 -5 0% load step O ver/U ndershoot 5% Full load R ipple & N oise 3/2 % pk-pk 1 2 V/1 5 -4 8 V m odels O vervoltage Protection 1 1 5 1 4 0 % Vnom , recycle input to reset O verload Protection 1 1 0 1 60 % I nom Short C ircuit Protection C ontinuous trip and restart (hiccup) T em perature C oefficient 0.05 % /˚C ECF40 Series w w w .xppow er.com 2 AC -D C Pow er Supplies Summary C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input R ange 80 1 1 5 /230 264 VAC D erate output from 1 00% at 90 VAC to 90% at 85 VAC and 80% at 80 VAC N o Load Input Pow er 0.1 5 W Efficiency 90 % 230 VAC (see fig.1 & 2) O perating T em perature -4 0 +7 0 °C See derating curve (fig.3) Safety A pprovals ITE IEC 609 50, U L609 50- 1, C SA 2 2 .2 N o.609 50- 1- 11 Ed 2 , EN 609 50- 1, LVD M edical IEC 60601- 1 Ed 3.1 Including R isk M anagem ent, AN SI/AAM I ES60601- 1 & C SA C 2 2 .2 N o.6061- 1:08, EN 60601- 1 General C haracteristic M inim um Typical M axim um U nits N otes & C onditions Efficiency 90 % Average active m ode efficiency at 25 % , 5 0% , 7 5 % and 1 00% load Isolation: Input to O utput Input to G round O utput to G round 4 000 VAC 2 M O PP 1 5 00 VAC 1 M O PP 5 00 VAC 1 M O PP at output voltage Pow er D ensity 8.1 W /in 3 M ean Tim e Betw een Failure 500 kH rs M IL-H D BK-21 7 F , N otice 2 +25 °C G B W eight 0.1 5 (69.0) lb(g) C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input Voltage - O perating 80 1 1 5 /230 264 VAC D erate output from 1 00% at 90 VAC to 90% at 85 VAC and 80% at 80 VAC Input Frequency 4 7 5 0/60 63 H z A gency approval, 4 7 -63 H z Pow er Factor EN 61 000-3-2 class A Input C urrent - Full Load 0.8/0.4 A 1 1 5 /230 VAC Inrush C urrent 60 A 264 VAC cold start, 25 ºC Earth Leakage C urrent 25 0 µA 264 VAC /60 H z N o load Input Pow er 0.1 5 W Input Protection T3.1 5 A /25 0 A , 25 0 V Internal fuse fitted in line and neutral.
C haracteristic M inim um Typical M axim um U nits N otes & C onditions O perating T em perature -4 0 +7 0 °C See derating curve, fig.3 Storage T em perature -4 0 +85 °C H um idity 5 95 % R H N on-condensing O perating A ltitude 5 000/4 000 m ITE/M edical Shock ±3 x 30g shocks in each plane, total 1 8 shocks. 30g = 1 1 m s (+/- 0.5 m secs), half sine. C onform s to EN 60068-2-27 Vibration Single axis 1 0-5 00 H z at 2g sw eep and endurance at resonance in all 3 planes. C onform s to EN 60068-2-6 ECF40 Series w w w .xppow er.com AC -D C Pow er Supplies Efficiency Vs Load Figure 1 EC F40PS12 Figure 2 EC F40PS24 100 2 5 5 0 7 5 1 0 0 Efficiency (%) Load (%)
115 VAC
Efficiency (%) Load (%)
EMC: Emissions EMC: Immunity ECF40 Series AC -D C Pow er Supplies w w w .xppow er.com 4 -40 -20 0 +70 +50 100 Some specification parameters may not be met Ambient Temperature (º C) Output Load (%) Figure 3 Tem perature D erating C urve Phenom enon Standard Test Level C riteria N otes & C onditions C onducted EN 5 5 01 1 /22 C lass B R adiated EN 5 5 01 1 /22 C lass A H arm onic C urrent EN 61 000-3-2 C lass A Voltage Functions EN 61 000-3-3 Phenom enon Standard Test Level C riteria N otes & C onditions M edical D evice EM C IEC 60601 -1 -2 Ed.4 .0 : 201 4 as below Low Voltage PSU EM C EN 61 204 -3 H igh severity level as below ESD EN 61 000-4 -2 ±8kV contact, ±1 5 kV air A R adiated EN 61 000-4 -3 3A EF T EN 61 000-4 -4 3A Surge EN 61 000-4 -5 Installation class 3 A C onducted EN 61 000-4 -6 3A M agnetic F ields EN 61 000-4 -8 4A D ips and Interruptions EN 61 000-4 -1 1 (1 00 VAC ) D ip 1 00% (0 VAC ), 8.4 m s A 25 % derating D ip 1 00% (0 VAC ), 1 6.7 m s B D ip 60% (4 0 VAC ), 200 m s B D ip 30% (7 0 VAC ), 5 00 m s B D ip 20% (80 VAC ), 5 000 m s B Int 1 00% (0 VAC ), 5 000 m s B EN 61 000-4 -1 1 (1 1 5 VAC ) D ip 1 00% (0 VAC ), 8.4 m s A D ip 1 00% (0 VAC ), 1 6.7 m s B D ip 60% (4 0 VAC ), 200 m s B D ip 30% (7 0 VAC ), 5 00 m s B D ip 20% (80 VAC ), 5 000 m s B Int 1 00% (0 VAC ), 5 000 m s B EN 61 000-4 -1 1 (24 0 VAC ) D ip 1 00% (0 VAC ), 1 0 m s A D ip 1 00% (0 VAC ), 20 m s B D ip 60% (96 VAC ), 200 m s B D ip 30% (168 VAC ), 500 m s B D ip 20% (1 92 VAC ), 5 000 m s B Int 1 00% (0 VAC ), 5 000 m s B EN 60601 -1 -2 (1 00 VAC ) D ip 1 00% (0 VAC ), 1 0 m s A 30% derating D ip 1 00% (0 VAC ), 20 m s A 60% derating D ip 60% (40 VAC ), 100 m s A 7 5 % derating D ip 30% (70 VAC ), 500 m s A Int 1 00% (0 VAC ), 5 000 m s B EN 60601 -1 -2 (4 20 VAC ) D ip 1 00% (0 VAC ), 1 0 m s A D ip 1 00% (0 VAC ), 20 m s A D ip 60% (96 VAC ), 100 m s A D ip 30% (168 VAC ), 500 m s A Int 1 00% (0 VAC ), 5 000 m s B
0.13 (3.18) 1.5 (38.1) 1.25 (31.57) Line Neutral 3.00 (76.2) Ø 0.14 (3.6) through in 4 positions Output Voltage Control -VE +VE Output Terminals 0.13 (3.18) 2.75 (69.85) 1.11 (28.14) ECF40 Series AC -D C Pow er Supplies 5 w w w .xppow er.com 02 Dec 16 Mechanical Details 1 . A ll dim ensions show n in inches (m m ). T olerance: ±0.02 (0.5 ) 2. W eight: 0.1 4 lbs (66 g) approx. N otes Safety Approvals Safety Agency Safety Standard N otes & C onditions C B R eport IEC 609 50- 1:2 005 Inform ation Technology U L U L609 50- 1, C SA 2 2 .2 N o.609 50- 1- 11 Ed 2 Inform ation Technology TU V EN 609 50- 1 Inform ation Technology C E LVD Safety Agency Safety Standard N otes & C onditions C B R eport IEC 60601- 1 Ed 3.1 Including R isk M anagem ent M edical U L AN SI/AAM I ES60601- 1: & C SA C 2 2 .2 N o.6061- 1:08 M edical C E EN 60601- 1 M edical Isolation Safety Standard N otes & C onditions Prim ary to Secondary 2 x M O PP (M eans of Patient Protection) IEC 60601- 1 Ed 3.1 Prim ary to Earth 1 x M O PP (M eans of Patient Protection) Secondary to Earth 1 x M O PP (M eans of Patient Protection) at output voltage C N 2 - O utput C onnector Pin 1 +Vout Pin 2 -Vout M ates w ith J ST housing VH R -2N and J ST Series SVH -21 T -P1 .1 crim p term inals C N 1 - Input C onnector Pin 1 N eutral Pin 2 N ot F itted Pin 3 Line M ounting hole m arked w ith m ust be connected to safety earth for class I M ates w ith J ST housing VH R -3N and J ST Series SVH -21 T -P1 .1 crim p term inals