DTMPU63 WALL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU63 Series

63 Watt

AC/DC Medical Desktop Power Supply Rev. A

FEATURES

  • Splash Proof
  • 3 Year Warranty
  • Class I Insulation
  • IEC 320-C14 Input Inlet
  • Optional Output Connectors
  • CEC and Energy Star Compliant
  • Output Voltage Protection (Crowbar Design)
  • Wide Input Voltage 90 to 264VAC, 47 to 63Hz
  • Output Voltages Available from 5VDC to 36VDC
  • Input Surge Current, Over Voltage, and Over Load Protection SPECIFICATIONS: DTMPU63 Series All specifications are based on 25 o C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Nom Max Unit INPUT (Vin) Input Voltage 90 264 VAC Input Frequency 47 63 Hz Input Current (Low Line) Io = Full Load, Vin = 115VAC 1.62 A Input Current (High Line) Io = Full Load, Vin = 230VAC 0.72 A Inrush Current (Low Line) Io = Full Load, 25°C, Cool Start, Vin = 115VAC 12 15 A Inrush Current (High Line) Io = Full Load, 25°C, Cool Start, Vin = 230VAC 26 30 A Safety Ground Leakage Current Io = Full Load, Vin = 240VAC 0.1 0.3 mA Start-Up Time Io = Full Load, Vin = 100VAC 0.3 1 2 s OUTPUT (Vo) Output Voltage Range See Rating Chart VDC Load Regulation Vin = 230VAC 3 7 % Line Regulation Io = Full Load 0.5 1 % Output Power Vin = 90 to 264VAC 0 63 W Output Current Range See Rating Chart A Ripple & Noise (peak to peak) Full Load, Vin = 90VAC 0.5 1 % Transient Response Io = Full Load to Half Load, Vin = 100VAC 4 ms Hold-Up Time Io = Full Load, Vin = 110VAC 16 ms Temperature Coefficient All Outputs -0.04 +0.04 %/°C PROTECTION Over Voltage Protection 112 132 % Over Current Protection 110 150 % GENERAL Efficiency Io = Full Load, Vin = 230VAC 77 85 88 % Dielectric Withstanding Voltage For Primary to Secondary Primary to Secondary 5600 VDC Dielectric Withstanding Voltage For Primary to Ground Primary to Ground 2800 VDC Isolation Resistance Test Voltage = 2100VDC 50 MΩ ENVIRONMENTAL Operating Temperature Derate linearly from 100% Load at 50°C to 50% load at 70°C 0 50 +70 °C Storage Temperature -40 +85 °C Relative Humidity 5 95 % MTBF 100,000 hours PHYSICAL Weight Approximately 510 ~ 560 grams Dimensions 5.75(L) x 2.99(W) x 1.69(H) inches Warranty 3 years SAFETY EMI Requirements for CISPR-11 Vin = 220VAC B Class EMI Requirements for FCC PART-18 Vin = 110VAC B Class

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU63 Series AC/DC Medical Desktop Power Supply Rev. A OUTPUT VOLTAGE / CURRENT RATING CHART Model Number Output Voltage Max. Output Current Total Regulation (3) Max. Output Power DTMPU63-102 5 VDC 9A 7% 45W DTMPU63-103 7 VDC 7.85A 7% 55W DTMPU63-104 9 VDC 6.44A 5% 58W *DTMPU63-105 12 VDC 5.25A 5% 63W *DTMPU63-106 15 VDC 4.20A 5% 63W *DTMPU63-107 18 VDC 3.50A 5% 63W *DTMPU63-108 24 VDC 2.62A 3% 63W *DTMPU63-109 30 VDC 2.10A 3% 63W *DTMPU63-110 36 VDC 1.75A 3% 63W NOTES 1. The asterisk “ * ” next to the model number indicates CEC level IV. 2. The models with output voltages under 15VDC have been approved by TUV/PSE and models with output voltages from 15VDC~30VDC have been approved by JET/PSE. 3. Models DTMPU63-102~103 need to use AWG#16/5C/4FT output cable in order to meet the total regulation. Models DTMPU63-104~105 need to use AWG#16/2C/4FT output cable in order to meet the total regulation. Models DTMPU63-106~107 need to use AWG#18/2C/4FT output cable in order to meet the total regulation. Models DTMPU63-108~110 need to use AWG#18/2C/6FT output cable in order to meet the total regulation. The regulation and efficiency will change if a different output cable is used. 4. Optional output connectors are available (see “DC Output Plug Selector List” link located at the bottom of the “Desktop” category page). DERATING CURVE

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU63 Series AC/DC Medical Desktop Power Supply Rev. A MECHANICAL DRAWING Unit: inches [mm]