Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU30 Series
30 Watts
Single, Dual, and Triple Outputs AC/DC Medical Desktop Power Supply Rev. B
FEATURES
- Splash Proof
- 3 Year Warranty
- Class I Insulation
- IEC-320-C14 Input Inlet
- Optional Output Connectors
- Single, Dual, and Triple Outputs
- Wide Input Voltage 90 to 264VAC, 47~63Hz
- Output Voltage Protection (Crowbar Design)
- Output Voltage Available from 3VDC thru 40VDC
- Input Surge Current, Over Voltage, and Over Load Protection SPECIFICATIONS: DTMPU30 Series All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Nom Max Unit INPUT (Vin) Operating Voltage Range 90 264 VAC Input Frequency 47 63 Hz Input Current (Low Line) Io = Full Load, Vin = 115VAC 0.9 A Input Current (High Line) Io = Full Load, Vin = 230VAC 0.34 A Inrush Current (Low Line) Io = Full Load, 25°C, Cool Start, Vin = 115VAC 12 15 A Inrush Current (High Line) Io = Full Load, 25°C, Cool Start, Vin = 230VAC 26 30 A Safety Ground Leakage Current Io = Full Load, Vin = 240VAC 0.1 mA Start-Up Time Io = Full Load, Vin = 100VAC 0.3 1.5 2 s OUTPUT (Vo) Output Voltage Range See Rating Chart VDC Load Regulation Vin = 230VAC 3 10 % Line Regulation Io = Full Load 0.5 1 % Output Power Range Vin = 90 to 264VAC 0 30 W Output Current Range See Rating Chart A *Ripple & Noise (peak to peak) Full Load, Vin = 90VAC 0.5 1 % Transient Response Io = Full Load to Half Load, Vin = 100VAC 4 ms Hold-Up Time Io = Full Load, Vin = 110VAC 12 ms Temperature Coefficient All Outputs -0.04 +0.04 %/°C PROTECTION Over Voltage Protection 112 132 % Over Current Protection 110 150 % GENERAL Efficiency Io = Full Load, Vin = 230VAC 70 83 85 % Dielectric Withstanding Voltage For Primary to Secondary Primary to Secondary 5600 VDC Dielectric Withstanding Voltage For Primary to Ground Primary to Ground 2800 VDC Isolation Resistance Test Voltage = 2100VDC 50 MΩ ENVIRONMENTAL Operating Temperature Derate linearly from 100% Load at 50°C to 50% load at 70°C 0 70 °C Storage Temperature -40 85 °C Relative Humidity 5 95 % PHYSICAL Weight Approximately 400 ~ 460 grams Dimensions 4.65 x 2.56 x 1.54 inches Warranty 3 years SAFETY EMI Requirements for CISPR-11 Vin = 220VAC B Class EMI Requirements for FCC PART-18 Vin = 110VAC B Class *Note: The Ripple & Noise for output voltages under 3.3VDC is 2% max.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU30 Series Single, Dual, and Triple Outputs AC/DC Medical Desktop Power Supply Rev. B OUTPUT VOLTAGE / CURRENT RATING CHARTS SINGLE OUTPUT MODELS Model Number Preset Voltage Output Voltage Range Max. Output Current Total Regulation Max. Output Power DTMPU30-101 5 VDC 3 ~ 5 VDC 6.66 ~ 4.00 A 5% 20W DTMPU30-102 6 VDC 5 ~ 6 VDC 5.00 ~ 4.16 A 5% 25W DTMPU30-103 8 VDC 6 ~ 8 VDC 4.16 ~ 3.12 A 5% 25W DTMPU30-104 11 VDC 8 ~ 11 VDC 3.75 ~ 2.72 A 4% 30W DTMPU30-105 13 VDC 11 ~ 13 VDC 2.72 ~ 2.30 A 3% 30W DTMPU30-106 16 VDC 13 ~ 16 VDC 2.30 ~ 1.87 A 3% 30W DTMPU30-107 21 VDC 16 ~ 21 VDC 1.87 ~ 1.42 A 3% 30W DTMPU30-108 27 VDC 21 ~ 27 VDC 1.42 ~ 1.11 A 2% 30W DTMPU30-109 33 VDC 27 ~ 33 VDC 1.11 ~ 0.91 A 2% 30W DTMPU30-110 40 VDC 33 ~ 40 VDC 0.90 ~ 0.75 A 2% 30W DUAL OUTPUT MODELS Model Number Output Voltage Min. Output Current Max. Output Current Max. Regulation Max. Output Power Output 1 +12 VDC 0.2A 2A 5% DTMPU30-209 Output 3 -12VDC 0A 0.5A 10% 30W Output 1 +15 VDC 0.15A 1.5A 5% DTMPU30-210 Output 3 -15 VDC 0A 0.5A 10% 30W TRIPLE OUTPUT MODELS Model Number Output Voltage Min. Output Current Max. Output Current Max. Regulation Max. Output Power Output 1 +5.0 VDC 0.25A 2.5A 5% Output 2 +12.0 VDC 0.13A 1.3A 5% DTMPU30-301 Output 3 -5.0 VDC 0A 0.5A 10% 25W Output 1 +5.0 VDC 0.25A 2.5A 5% Output 2 +12.0 VDC 0.1A 1.0A 5% DTMPU30-302 Output 3 -12.0 VDC 0A 0.5A 10% 30W Output 1 +5.0 VDC 0.25A 2.5A 5% Output 2 +15.0 VDC 0.1A 1.0A 5% DTMPU30-303 Output 3 -15.0 VDC 0A 0.5A 10% 30W Output 1 +5.0 VDC 0.3A 3.0A 5% Output 2 +24.0 VDC 0.1A 1.0A 5% DTMPU30-304 Output 3 -24.0 VDC 0A 0.5A 10% 30W Output 1 +5.0 VDC 0.3A 2.5A 5% Output 2 +24.0 VDC 0.1A 1.0A 5% DTMPU30-305 Output 3 -12.0 VDC 0A 0.5A 10% 30W Output 1 +3.3 VDC 0.25A 2.5A 7% Output 2 +12 VDC 0.11A 1.1A 5% DTMPU30-306 Output 3 -5 VDC 0A 0.5A 10% 25W NOTES 1. For single output models the output voltage is specified as a range (Ex: 33 ~ 40VDC); the preset voltage will be set as standard models if nothing different is requested. Please contact factory for ordering details. 2. Optional output connectors are available (see “DC Output Plug Selector List” link located at the bottom of the “Desktop” category page).
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU30 Series Single, Dual, and Triple Outputs AC/DC Medical Desktop Power Supply Rev. B DERATING CURVE MECHANICAL DRAWING Unit: inches [mm]