Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU15 Series

15 Watt Single Output

AC/DC Desktop Power Supply Rev. B

FEATURES

  • Splash Proof
  • Single Output
  • 3 Year Warranty
  • Optional Output Connectors
  • Over Temperature Detection
  • A & C Types: Class I Insulation
  • 3 Types of Inlet Connectors Available
  • Over Voltage and Over Load Protection
  • Wide Input Voltage 90 to 264VAC, 47~63Hz
  • B Type: Class II Insulation (Double Insulation)
  • Output Voltages Available from 5VDC to 36VDC SPECIFICATIONS: DTMPU15 Series All specifications are based on 25 o C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Nom Max Unit INPUT (Vin) Operating Voltage Range 90 264 VAC Input Frequency 47 63 Hz Input Current (Low Line) Io = Full Load, Vin = 115VAC 0.25 0.33 A Input Current (High Line) Io = Full Load, Vin = 230VAC 0.17 0.18 A Inrush Current (Low Line) Io = Full Load, 25°C, Cool Start, Vin = 115VAC 14 16 A Inrush Current (High Line) Io = Full Load, 25°C, Cool Start, Vin = 230VAC 28 30 A Safety Ground Leakage Current Io = Full Load, Vin = 240VAC 0.3 mA Start-Up Time Io = Full Load, Vin = 100VAC 0.5 1 s OUTPUT (Vo) Output Voltage Range See Rating Chart VDC Load Regulation Vin = 230VAC 1 3 5 % Line Regulation Io = Full Load 0.5 1 % Output Power Range Vin = 90 to 264VAC 0 15 W Output Current Range See Rating Chart A Ripple & Noise (peak to peak) Full Load, Vin = 90VAC 0.5 1 % Transient Response Io = Full Load to Half Load, Vin = 100VAC 4 ms Hold-Up Time Io = Full Load, Vin = 110VAC 10 16 ms PROTECTION Over Voltage Protection (1) 112 132 % Over Current Protection (1) 110 150 % GENERAL Efficiency Io = Full Load, Vin = 230VAC 73 85 % Dielectric Withstanding Voltage For Primary to Secondary Primary to Secondary 5600 VDC Dielectric Withstanding Voltage For Primary to Ground (A & C Types Only) Primary to Ground 2800 VDC Isolation Resistance Test Voltage = 500VDC 50 MΩ Power Consumption (No Load) No Load, Vin = 230VAC 0 0.4 0.5 W ENVIRONMENTAL Operating Temperature Derate linearly from 100% Load at 50°C to 50% load at 70°C 0 50 70 °C Storage Temperature -40 85 °C Relative Humidity 5 95 % Temperature Coefficient All Outputs -0.04 +0.04 %/°C Thermal Shutdown by Junction Temperature Controller (1) The parameter is not subject to production test-verified by design/characterization of integrated controller. -20 +125 °C MTBF Operating temperature at 25°C, calculated per MIL-HDBK-217F 100,000 hours PHYSICAL Weight Approximately 170 grams Dimensions A Type: 4.11 x 1.65 x 1.22 inches B & C Types: 3.90 x 1.65 x 1.22 inches Input Inlet IEC-320-C14, IEC-320-C8, IEC-320-C6 Warranty 3 years SAFETY EMI Requirements for EN55022 Vin = 230VAC, 50Hz B Class EMI Requirements for FCC Part-15, FCC Part 18 Vin = 120VAC, 60Hz B Class (1) When the power system interruption is isolated, the product would re-start after recovering by hand. Type A Type B Type C

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU15 Series AC/DC Desktop Power Supply Rev. B OUTPUT VOLTAGE/ CURRENT RATING CHART Model Number Output Voltage Output Current Total Regulation (2) Maximum Output Power DTMPU15x-102 5 VDC 2.60A 5% 13W DTMPU15x-103 7 VDC 1.85A 5% 13W DTMPU15x-104 9 VDC 1.66A 5% 15W DTMPU15x-105 12 VDC 1.25A 5% 15W DTMPU15x-106 16 VDC 0.93A 5% 15W DTMPU15x-107 18 VDC 0.83A 5% 15W DTMPU15x-108 24 VDC 0.62A 3% 15W DTMPU15x-109 30 VDC 0.50A 3% 15W DTMPU15x-110 36 VDC 0.41A 3% 15W NOTES 1. The DTMPU15 Series is designated as DTMPU15x-y where x represents the type of AC input inlet connector which can either be A (IEC-320-C14), B (IEC-320-C8), or C (IEC-320-C6); y can be 102, 103, 104, 105, 106, 107, 108, 109, or 110 for output voltage. 2. Models DTMPU15-102, 103, and 105 needs to use AWG#16/4FT output cable in order to meet the total regulation. Models DTMPU15-104, 106~110 needs to use AWG#18/4FT output cable in order to meet the total regulation. The regulation and efficiency will change if a different output cable is used. 3. Optional output connectors are available (see “DC Output Plug Selector List” link located at the bottom of the “Desktop” category page). DERATING CURVE

Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTMPU15 Series AC/DC Desktop Power Supply Rev. B MECHANICAL DRAWINGS Unit: inches [mm] TYPE A TYPES B & C