DTIPU30 WALL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTIPU30 Series Single Output Up to 30 Watts AC/DC Desktop Power Supply Rev A
FEATURES
- Splash Proof
- 100% Burn-in
- Class I Insulation
- IEC-320-C14 Input Inlet
- Optional Output Connectors Available
- Over Voltage Protection (Crowbar Design)
- -20°C ~ +70°C Operating Temperature Range
- Wide Input Voltage Range: 90 to 264VAC, 47~63Hz
- Input Surge Current, Over Voltage, and Over Load Protection
DESCRIPTION
The DTIPU30 series of AC/DC desktop switching mode power supplies provide up to 30 watts of continuous output power. All models have a single output, universal input voltage range, and an operating te mperature range of –20°C ~ +70°C. These supplies are also pr otected against input surge current, over voltage, and over load conditions. All supplies are also UL 94V-1 compliant and include an IE C-320-C14 input connector for worldwide applications. All models meet FCC- Part-15 class B and CISPR-22 class B emission limits and are de signed to comply with UL/c-UL (UL 60950-1), TUV/GS (EN 60950-1), and new CE requirements. These supplies are 100% burn-in tested. SPECIFICATIONS: DTIPU30 Series All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Nom Max Unit INPUT (Vin) Operating Voltage Range 90 264 VAC Input Frequency 47 63 Hz Input Current (Low Line) Io = Full Load, Vin = 115VAC 0.8 A Input Current (High Line) Io = Full Load, Vin = 230VAC 0.5 A Inrush Current (Low Line) Io = Full Load, 25°C, Cool Start, Vin = 115VAC 12 15 A Inrush Current (High Line) Io = Full Load, 25°C, Cool Start, Vin = 230VAC 26 30 A Safety Ground Leakage Current Io = Full Load, Vin = 240VAC 0.5 0.75 mA Start-Up Time Io = Full Load, Vin = 100VAC 0.3 1 2 s OUTPUT (Vo) Output Voltage See Rating Chart VDC Load Regulation Vin = 230VAC 3 7 % Line Regulation Io = Full Load 0.5 1 % Output Power Vin = 90 to 264VAC 0 30 W Output Current See Rating Chart A *Ripple & Noise (peak to peak) Full Load, Vin = 90VAC 0.5 1 % Transient Response Time Io = Full Load to Half Load, Vin = 100VAC 4 ms Hold-Up Time Io = Full Load, Vin = 100VAC 12 ms Temperature Coefficient All Outputs -0.04 +0.04 %/°C PROTECTION Over Voltage Protection 112 132 % Over Current Protection 110 150 % GENERAL Efficiency Io = Full Load, Vin = 230VAC 65 75 85 % Dielectric Withstanding Voltage For Primary to Secondary Primary to Secondary 4242 VDC Dielectric Withstanding Voltage For Primary to Ground Primary to Ground 2121 VDC Isolation Resistance Test Voltage = 500VDC 50 MΩ ENVIRONMENTAL Operating Temperature Derates linearly from 100% Load at 40°C to 50% load at 70°C -20 +70 °C Storage Temperature -40 +85 °C Relative Humidity 5 95 % MTBF Operating Temperature at 25°C, Calculated per MIL-HDBK-217F 100,000 hours PHYSICAL Weight Approximately 265 ~ 280 grams Dimensions (L x W x H) 4.65 x 2.05 x 1.36 inches 118.0 x 52.0 x 34.5 mm Warranty 2 years SAFETY EMI Requirements for CISPR-22 Vin = 220VAC B Class EMI Requirements for FCC PART-15 Vin = 110VAC B Class *Note: The Ripple & Noise for output voltages under 3.3VDC is 2% max.
APPLICATIONS
- Scanners
- LCD Monitors
- Thermal Printers
- Humidity Temperature Meters
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 DTIPU30 Series Single Output Up to 30 Watts AC/DC Desktop Power Supply Rev A OUTPUT VOLTAGE / CURRENT RATING CHART Model Number Input Current Preset Voltage Output Voltage Range Output Current Total Regulation(3) Output Power *DTIPU30-101 90 ~ 264VAC 5 VDC 3 ~ 5 VDC 5.00 A max 7% 20W *DTIPU30-102 90 ~ 264VAC 6 VDC 5 ~ 6 VDC 5.00 ~ 4.16 A 5% 25W DTIPU30-103 90 ~ 264VAC 8 VDC 6 ~ 8 VDC 4.16 ~ 3.12 A 5% 25W DTIPU30-104 90 ~ 264VAC 11 VDC 8 ~ 11 VDC 3.75 ~ 2.72 A 5% 30W DTIPU30-105 90 ~ 264VAC 13 VDC 11 ~ 13 VDC 2.72 ~ 2.30 A 5% 30W DTIPU30-106 90 ~ 264VAC 16 VDC 13 ~ 16 VDC 2.30 ~ 1.87 A 5% 30W DTIPU30-107 90 ~ 264VAC 21 VDC 16 ~ 21 VDC 1.87 ~ 1.42 A 5% 30W DTIPU30-108 90 ~ 264VAC 27 VDC 21 ~ 27 VDC 1.42 ~ 1.11 A 5% 30W DTIPU30-109 90 ~ 264VAC 33 VDC 27 ~ 33 VDC 1.11 ~ 0.90 A 5% 30W DTIPU30-110 90 ~ 264VAC 40 VDC 33 ~ 40 VDC 0.90 ~ 0.75 A 3% 30W DTIPU30-111 90 ~ 264VAC 50 VDC 40 ~ 50 VDC 0.75 ~ 0.60 A 3% 30W NOTES 1. For single output models the output voltage is specified as a range (Ex: 40 ~ 50VDC); the preset voltage will be set as standard models if nothing different is requested. Please contact factory for ordering details. 2. The “ * ” symbol means PSE approval. 3. Models 101~102 need to use AWG#16/4FT output cable in order to meet the total regulation. Models 103~111 need to use AWG#18/6FT output cable in order to meet the total regulation. 4. Optional output connectors are available. Please call factory for ordering details. MECHANICAL DRAWING Unit: inches [mm]