ETA-USA Tel : 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta -usa.com 1) INPUT Description Min. Typical Max. Condition Input Voltage 90VAC 115/230V 264VAC Full Range; 50/60Hz Input Current(RMS) 2A @ 90Vac 1A @ 264Vac Max. Line Frequency 47Hz 50/60Hz 63Hz - Efficiency >80% 115VAC at full load EMI: FCC Class B; CISRP22 Class B; EN 55022 Class B 2) OUTPUT *Volt age Regulation: ±3% *Hold Up Time: 10ms typical at full load @ 115VAC Output Current Model Name Nominal Voltage Max. Power MIN. MAX. Ripple & Noise DTB40-09SX-W 9 40W 0.0A 4.4A 90mv DTB40-12SX-W 12 40W 0.0A 3.3A 120mv DTB40-13SX-W 13 40W 0.0A 3.1A 130mv NOTE: 1. Peak to Peak with 20MHz bandwidth and 10uF in parallel with a 0.1uF capacitor. 2. CV-Constant Voltage: +9V~+13.8V/40W 3)PROTECTION:

  • OVER VOLTAGE PROTECTION(OVP)
  • AC RECYCLE SHORT CIRCUIT PROTECTION
  • OUTPUT SHORT CIRCUIT PROTECTION(<0.03 OHM)
  • AUTO RECOVERY 4) ENVIRONMENT: Operating Temperature 0°C to 40°C Storage Temperature -10°C to +70°C MTBF: > 100’000 hours at full load and 25°C ambient temperature. GENERAL SPECIFICATION This specification describes the performance characteristics of a grounded, single phase, 40 Watts, Single Output Switching Adapter.

40 WATT

ETA-USA Tel : 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta -usa.com 5) SAFETY REQUIREMENTS UL 1950 CSA 22.2-234 TUV EN60950 IEC 950 CE: EMC &LVD 6) DIMENSION Dimension: 132(L) × 69(W) × 40(H)mm