DSL240 XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

240 Watts

  • Ultra Slim Design
  • 150% Peak Load for 3 seconds
  • Full Power from -40 °C to +60°C
  • High Efficiency – Up to 93%
  • Hazardous Locations Approval
  • Parallel Capability
  • 3 Year Warranty DSL240 Series Input Input Voltage • 88-264 VAC (120-375 VDC) Input Frequency • 47-63 Hz Input Current • 2.3 A at 115 VAC, 1.15 A at 230 VAC Inrush Current • 24/48 A max at 115/230 VAC Power Factor • 0.97 typical at 230 VAC Conforms to EN61000-3-2 Class A. Earth Leakage Current• 3.5 mA maximum Input Protection • Internal fuse in line, T5.0 A/250 VAC Output Output Voltage • See table Output Voltage Trim • See table Initial Set Accuracy • +1% at 100% load Minimum Load • No minimum load required Start Up Delay • 1.0 s max Start Up Rise Time • 150 ms max Hold Up Time • 25 ms minimum at full load and 115 VAC Line Regulation • ±1% Load Regulation • ±1% (±5% in parallel mode) Transient Response • 10% maximum deviation, recovering to less than 1% within 2 ms for 50% step load change at 0.2 A/µs Ripple & Noise • 100 mV pk-pk maximum, measured with

20 MHz bandwidth

Overvoltage Protection• 12 V output: 15-16.5 V,

24 V output: 30-33 V

Overload Protection • 120-150% of rated current (see application note) Short Circuit Protection• Trip and restart (hiccup mode) auto recovery within 7 s Temperature • ±0.03%/°C Coefficient Thermal Protection • 110°C max, measured on internal heatsink auto recovery Parallel Operation • A maximum of 3 units can be paralleled. Max power available is 90% of total rated power. Minimum load of 10% required per unit Maximum Capacitive • 7000 µF (start up delay increases to 1.5s Load and rise time to 500 ms) xppower.com General Efficiency • See table Isolation • 3000 VAC Input to Output

1500 VAC Input to Ground

500 VAC Output to Ground

Switching Frequency • 100 kHz typical PFC & main converter at

230 VAC and full load

DC OK Signal • Volt free contacts rated at 60 VDC/ 0.3 A on 24 V versions only Output LED • Green LED to indicate output on. Red LED to indicate low output voltage. See mechanical details for operating range. MTBF • >370 kHrs to BELLCORE Issue 6 at 40 °C, GB Environmental Operating Temperature• -40 °C to +70 °C (see derating curves) Cooling • Natural convection Operating Humidity • 20-95% RH, non-condensing Protection • IP20 Storage Temperature • -40 °C to +85 °C Operating Altitude • 4850 m Shock • IEC68-2-27, 4 g, 22 ms half sine, 3 times in each of 6 axes Vibration • IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep. 60 mins for each of 3 axes EMC & Safety Emissions • EN55022, class B conducted & radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, 8 KV Contact,

15 KV Air Discharge, Perf Criteria A

Radiated Immunity • EN61000-4-3, 10 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 4 Perf Criteria A Surge • EN61000-4-5, Installation Class 4 Perf Criteria A Conducted Immunity • EN61000-4-6, 10 V Perf Criteria A Magnetic Field • EN61000-4-8, level 4, Perf Criteria A Dips & Interruptions • EN55024, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals • UL508, UL60950-1, EN60950-1, ANSI/ISA 12.12.01 (Class I, Division 2, Groups A, B, C and D)

Output Voltage Output Power Output Voltage Trim(4) Output Current Peak Load(3) Typical Efficiency(2) Model Number (1) 12 V 192 W 11.75-14.5 V 16.0 A 24.0 A 90% DSL240PS12-I 24 V 240 W 22.5-28.5 V 10.0 A 15.0 A 93% DSL240PS24-I Notes 1. Add suffix ‘D’ for detachable connector option e.g. DSL240PS24-ID. 2. Typical efficiency at 230 VAC and full load. 3. Peak load is for a maximum of 3 s with 20% duty cycle. Average power is not to exceed nominal output power. 4. Output current should be limited so that nominal output power is not exceeded. -20 -40 0 10 20 30 40 50 60 70 100 Ambient Temp (˚C) Load (%) 4.59 (116.6) 2.52 (64.0) 4.9 (124.50) 5.65 (143.5) 0.3 (7.0) ‘-D’ version (detachable connectors) The green LED is lit if the output voltage is OK (10-11.2 VDC for 12 V units, 17.6-19.4 VDC for 24 V units at start up) The red LED is lit if the output voltage is low (10-11.2 VDC for 12 V units, 17.6-19.4 VDC for 24 V units after start up) Pin Connections Conn Pin Designation AC Input

1 Ground

2 Neutral

3 Line

1 DC OK*

2 DC OK*

3 Positive

4 Positive

5 Negative

6 Negative

Contact Rating: 0.3 A at 60 VDC

500 VDC isolation

Open = Output fail Closed = Output good * 24 V models only. 1. All dimensions in inches (mm) 2. Weight: 1.916 lbs (860g) 3. Tolerance: ±0.02 in (±0.5 mm) 4. Screw terminal: 10-24 AWG cables size. Detachable connector version: 14-24 AWG cable size. Notes Derating Curves Peak Loading DC OK OCP Peak Continuous 3 sec 3 sec Auto recovery within 7 sec < 7 sec OCP < 7 sec

360 W for 24 V

258 W for 12 V

198 W for 12 V