DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

(Reference DP35D6S for Prime Rating Technical Data) SYSTEM RATINGS Standby DS35D6SGT DS35D6SPT DS35D6SJT DS35D6SVT DS35D6SRT DS35D6SNT Phase 1 3 3 3 3 3 Hz 60 60 60 60 60 60 kW 37 35 35 37 35 35 Amps 154 121 105 70 53 42 skVA@30% Voltage Dip 62 106 106 128 141 123 Generator Model 361CSL1601 284PSL1708 284PSL1708 361CSL1601 284PSL1708 284PSL5252 Temp Rise 130 °C/40 °C 130 °C/40 °C 130 °C/40 °C 130 °C/40 °C 130 °C/40 °C 130 °C/40 °C Connection 12 LEAD 12 LEAD 12 LEAD 12 LEAD 12 LEAD DOUBLE DELTA LOW WYE HI DELTA HI WYE HI WYE 4 LEAD WYE ** UL 2200 Off ered // Emissions – EPA Tier 3 Certifi ed // Generator set is designed and manufactured in facilities certifi ed to standards ISO 9001:2008 and ISO 14001:2004 // UL 2200 / CSA – Optional – UL 2200 Listed – CSA Certifi ed // Performance Assurance Certification (PAC) - Generator Set Tested to ISO 8528-5 for Transient Response - Verifi ed product design, quality and performance integrity - All engine systems are prototype and factory tested // Power Rating - Accepts Rated Load in One Step Per NFPA 1 10 CERTIFICATIONS AND STANDARDS

// Engine Air Cleaner Oil Pump Oil Drain Extension & S/O Valve Full Flow Oil Filter Fuel Filter with Water Separator Jacket Water Pump Thermostat Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 12V Governor – Mechanical Droop Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 12V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certifi ed Engine // Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Self-Ventilated and Drip-Proof Superior Voltage Waveform Solid State, Volts-per-Hertz Regulator ±1% Voltage Regulation No Load to Full Load Brushless Alternator with Brushless Pilot Exciter

4 Pole, Rotating Field

130 °C Maximum Standby Temperature Rise

1 Bearing, Sealed

125% Rotor Balancing 3-Phase Voltage Sensing 100% of Rated Load - One Step 5% Maximum Total Harmonic Distortion // Digital Control Panel(s) Digital Metering Engine Parameters Generator Protection Functions Engine Protection Windows ®-Based Software Multilingual Capability Remote Communications to RDP-1 10 Remote Annunciator Programmable Contact Inputs Programmable Contact Outputs UL Recognized, CSA Certifi ed, CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA1 10 Compatible STANDARD EQUIPMENT* // MTU Onsite Energy is a single source supplier // Global Product Support // 2 Year Standard Warranty // 4045TF280 Diesel Engine - 4.5 Liter Displacement - Mechanical Injection Pump - 4-Cycle // Engine-generator resilient mounted // Complete Range of Accessories // Generator - Brushless, Rotating Field Generator - 2/3 Pitch Windings - 300% Short Circuit Capability with Optional PMG // Digital Control Panel(s) - UL Recognized, CSA Certi fi ed, NFPA 1 10 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine Driven Fan STANDARD FEATURES* * Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional confi gurations.

// Engine Manufacturer John Deere Model 4045TF280 Type 4-Cycle Arrangement 4-Inline Displacement: L (in 3) 4.5 (275) Bore: cm (in) 10.6 (4.19) Stroke: cm (in) 12.7 (5.0) Compression Ratio 19.0:1 Rated RPM 1,800 Engine Governor Mechanical Droop Maximum Power: kWm (bhp) 63 (85) Speed Regulation ±0.50% Air Cleaner Dry // Liquid Capacity (Lubrication) Total Oil System: L (gal) 13 (3.4) Engine Jacket Water Capacity: L (gal) 8.5 (2.3) System Coolant Capacity: L (gal) 18.9 (5) // Electrical Electric Volts DC 12 Cold Cranking Amps Under -17.8 °C (0 °F) 925 // Fuel System Fuel Supply Connection Size 3/8” NPT Fuel Return Connection Size 3/8” NPT Maximum Fuel Lift: m (ft) 1.8 (6) Recommended Fuel Diesel #2 Total Fuel Flow: L/hr (gal/hr) 62.5 (16.5) // Fuel Consumption STANDBY At 100% of Power Rating: L/hr (gal/hr) 17.4 (4.6) At 75% of Power Rating: L/hr (gal/hr) 13.6 (3.6) At 50% of Power Rating: L/hr (gal/hr) 9.5 (2.5) // Cooling - Radiator System STANDBY Ambient Capacity of Radiator: °C (°F) 50 (122) Maximum Allowable Static Pressure on Rad. Exhaust: kPa (in. H20) 0.12 (0.5) Water Pump Capacity: L/min (gpm) 144 (38) Heat Rejection to Coolant: kW (BTUM) 36 (2,049) Heat Radiated to Ambient: kW (BTUM) 7.4 (422) Fan Power: kW (hp) 1.6 (2.2) // Air Requirements STANDBY Aspirating: *m3/min (SCFM) 5.3 (187) Air Flow Required for Rad. Cooled Unit: *m3/min (SCFM) 1 17 (4,088) Remote Cooled Applications; Air Flow Required for Dissipation of Radiated Gen-set Heat for a Max of 25 °F Rise: *m 3/min (SCFM) 27 (952) * Air density = 1.184 kg/m3 (0.0739 lbm/ft3) // Exhaust System STANDBY Gas Temp. (Stack): °C (°F) 579 (1,074) Gas Volume at Stack Temp: m 3/min (CFM) 19.2 (679) Maximum Allowable Back Pressure: kPa (in. H20) 7.5 (30) Minimum Allowable Back Pressure: kPa (in. H20) N/A APPLICATION DATA

© MTU Onsite Energy. Subject to alteration due to technological advances. OE 23 457 (77 3E) 2014-02 EMISSIONS DATA NOx HC CO PM 3.1 0.22 0.8 0.18 All units are in g/hp-hr and are EPA D2 cycle values. Emission levels of the engine may vary as a function of ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided are laboratory results from one engine representing this rating. The data was obtained under controlled environmental conditions with calibrated instrumentation traceable to the United States National Bureau of Standards and in compliance with US EPA regulations found within 40 CFR Part 89. The weighted cycle value from each engine is guaranteed to be below the US EPA Standards at the US EPA defi ned conditions. RATING DEFINITIONS AND CONDITIONS // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO 3046-1, BS 5514, AS 2789, and DIN 6271. // Deration Factor: Altitude: Consult your local MTU Onsite Energy Power Generation Distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation Distributor for temperature derations. WEIGHTS AND DIMENSIONS SOUND DATA Unit Type Standby Full Load Level 0: Open Power Unit dB(A) 80.5 Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with infi nite exhaust. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 1,724 x 752x 1,321 mm (67.87 x 29.62 x 52 in) 805 kg (1,770 lb) Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specifi c template drawings. Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specifi c generator set. Materials and specifi cations subject to change without notice. C/F = Consult Factory/MTU Onsite Energy Distributor MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com