Platon Metal Tube VA Gas or Liquid DS1220 © TT Electronics plc Issue B 7/2017 Page 1 TT Electronics | Roxspur Measurement & Control Ltd
2 Downgate Drive, Sheffield, S4 8BT, England |Ph: +44(0)114 244 2521
www.roxspur.com | sales@roxspur.com General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Features: ½” - 4” line sizes No power required Clearly visible meter Scaled for process fluids Easy installation—flanged or screwed No glands or seals Robust, simple construction Pulsation damper on gas meter PLATON METAL TUBE VA FLOWMETER TYPE GMT GMT metal tube flowmeters are variable area meters of totally welded stainless steel construction. Liquid or Gas flowing up the tapered flowtube lifts the float to an equilibrium position, dependent on flow rate, and a magnetically coupled pointer indicates this flow on an external scale. The large meter indication is easily visible at a distance, with the pointer moving over a 1500 scale. Each scale is produced specifically for the fluid involved and process conditions expected: several flow ranges are available for meters of each standard line size. All gas flow meters are supplied with an integral piston damper t o smooth out flow pulsations. Installation is simple, in a vertical section of flow line: meters can be supplied with EN, ANSI or other standard flanges, o r BSP or NPT screwed connections. The robust construction with no glands or seals to leak means the meters are suitable for high pressure applications, or extremes of temperature. The standard GMT is totally self contained and needs no external power. Alternative materials are available to special order -for example Hastelloy or Monel wetted parts. For lower cost, Brass or Stainless steel bodied meters \`”-2” in size are available with screwed connections. The indicator can be provided with one or two flow alarm sensors, adjustable over the meter operating range. Full electronic transmission and totalization is also available, using the “VAMPIRE” electronic module. Metal tube meters are ideal for arduous industrial service as an alternative to large glass tube flowmeters. They have partic- ular advantages, where fluids are opaque or staining, or to provide higher safety and security for dangerous or toxic fluids. PRINCIPLE OF OPERATION The metering element consists of a precision machined tapered tube and a float. The height to which the float rises in taper is determined by the gap at which upward flow force and float weight are balanced. A permanent magnet encapsulated within the stainless steel float drives the external magnetically coupled pointer. Float movement is related to flow rate, and the indicator scale is marked in the correct units of flow for the process conditions. The standard unit requires no electrical power. Because the measuring element is a sharp edged disc, the meter is relatively insensitive to viscosity changes in the fluid, and to pipe bends in the external pipework. The only moving part in the flow i s the float, which is retained in place by float guides at either end of the meter.
© TT Electronics plc Issue B 7/2017 Page 2 TT Electronics | Roxspur Measurement & Control Ltd www.roxspur.com | sales@roxspur.com General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Platon Metal Tube VA Gas or Liquid DS1220 Flanged flow tube 316 Stainless Steel, all welded construction Flanges EN1092-1 PN16 or ANSI 150 standard. Other flanges to order Line Sizes 15, 25, 50, 80, 100mm Pressure To flange rating, 100 bar max Screwed flow tube Brass or 316 Stainless Steel Connections ½”, 1” or 2” BSPP or NPT standard Pressure 75 bar max GMTB (Brass) 100 bar max GMTS (Stainless) Float 316 Stainless Steel PVC float on low pressure drop option units Pulsation Damper All gas flowmeters have a dashpot damper built-in SPECIFICATION Indicator housing Polyester coated aluminum alloy, with UV stable polycarbonate face Protection IP65 Scale length Typically 100mm, 150 degrees Scales Produced to order to suit process fluid and conditions. Air and water flow ranges quoted opposite Turndown Typically 10:1 Accuracy ±2% FSD Hysteresis ±0.5% FSD Fluid Temperature 200˚C max (higher to special order) Response time Less than 0.5 secs Flow direction Vertically upwards Surface finish 1.6µm ORDER CODE Model Number GMT - - 3 1 4 G GMT Family Model Type No Digit Flanged Stainless B Brass Body Screwed S Stainless Body Screwed Electronics Outputs No Digital Standard Indicator A Single Flow Alarm AA Dual Flow Alarm XA AC Powered Transmitter XD CENELEC Approved Looped Power Transmitter Flow Pipe Size 1 15mm or 1/2” 2 25mm or 1” 3 50mm or 2” 4 80mm or 3” 5 100mm or 4” - (Example is 2” GMT, Flanged PN16 ranged 20-180m³/h Air) Fluid G = Gas L = Liquid Digit to identify specified flow range (See Table on Next Page) End Connections
1 Flanged EN PN16
2 Flanged ANSI 150lb
3 Flanged EN PN40
4 Flanged ANSI 300lb
5 Screwed BSPP Female
6 Screwed NPT Female
Specify process conditions at measurement point (Fluid type, density/SG, viscosity, temperature and pressure) plus operational flow range and units Note: Not all options available together
© TT Electronics plc Issue B 7/2017 Page 3 TT Electronics | Roxspur Measurement & Control Ltd www.roxspur.com | sales@roxspur.com General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Platon Metal Tube VA Gas or Liquid DS1220 FLOW RANGES OPTIONS 1. Oxygen Service Standard units cleaned to required specifications. Special units available with Brass internal construction 2. Alarm Output Sensor NAMUR type SJ2-N to DIN 19234 Approval EEx ia LLC T6 Single or dual alarms can be fitted to a GMT flowmeter: The sensor requires a suitable control room interface. Please ask for suppliers sep arate data sheet. 3. Electrical Output All GMT flow tube sensors can be fitted with “VAMPIRE” micro based electronics transmitter and flow indicator units. Please see Data Sheet DS1225. 4. Alternative body Materials/Design PTFE lined meter available for use with corrosive chemical. Float, guides and Flange raised face are PFTE or ceramic. Size/Model Flow Digit Water (20˚C) Air at ATP (m³/hr) Max DP (mbar) Flow Digits Air (ATP) m³/hr Natural Gas (ATP) m³/hr Max DP (mbar) 15mm (GMT1) 25mm (GMT2) 50mm (GMT3) 80mm (GMT4) 100mm (GMT5) 20-160 l/h 20-250 l/h 40-400 l/h 60-600 l/h 0.1-1.0 m³/h 0.2-1.6 m³/h 0.2-2.5 m³/h 0.4-4.0 m³/h 0.6-6.0 m³/h 1.0-10.0 m³/h 0.6-6.0 m³/h 1.0-10.0 m³/h 2.0-16.0 m³/h 2.0-25.0 m³/h 2.0-2.5 m³/h 3.0-40 m³/h 6.0-60 m³/h 10-100 m³/h 0.5-5.0 0.5-7.5 1.2-12 2.0-18 3.0-30 4.0-50 10-75 12-120 20-200 30-360 20-180 30-300 60-600 100-1000 N/A N/A N/A N/A 160 400 190 140 220 525 440 A B C D A B C D 0.3.-3 0.4-4 0.5-7 1.0-9 1.5-15 3-23 4-36 5-50 0.4-3.5 0.5-5 1.0-9 1.0-12 2-20 4-30 5-45 6-60 STANDARD UNITS LOW DP GAS UNITS NOTES 1. Unites will be scaled and calibrated for cus- tomers specific process conditions, which may differ from those trabulated (see over- leaf). 2. Typical maximum liquid viscosity is 50cP, lower for the highest flow ranges and small sizes. 3. Screwed 1? Units are not available for Flow Digit 6. The hygienic option with crevice free construction is polished to 0.4 - 0.8 µm finish and fitted with Triclover connections. In addition Triclover, RJT, DIN 11851, SMS connections can be fitted to standard flaged body. Refer to DS1221 for screwed GMT data sheet
© TT Electronics plc Issue B 7/2017 Page 4 TT Electronics | Roxspur Measurement & Control Ltd www.roxspur.com | sales@roxspur.com General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Platon Metal Tube VA Gas or Liquid DS1220 ALTERNATIVE FLUIDS Approximate flow ranges for alternative process fluids and gas pressures can be calculated using the following formulae. For a full calculation please contact our Sales Team. 1. Gases at pressure or temperature For air or gas flows where the pressure in the line on the discharge side of the flowmeter is not atmospheric (1.013 bar), multiply the flow range at ATP quoted in the table by a factor calculated as the square root of the pressure (in bar abs) divided by 1.013. Air flow in process = P (abs) 1.013 x Air flow in table For temperature changes: Air flow at T = 293 T (K) x Air flow in table 2. Alternative gases For gases other than air, find the Relative Density (RD) of the gas compared to air, and divide the flow range quoted for air in the table by the square root of the Relative Density. Gas flow range = Air flow in table x Examples of RD figures for some gases are as follows RD Acetylene 0.898 Carbon Dioxide 1.520 Nitrogen 0.968 Argon 1.380 Hydrogen 0.070 Oxygen 1.105 Butane 2.007 Natural Glass 0.608 Propane 1.522 3. Alternative liquids For non-vicious liquids other than water, the main correction arises from the density/SG. For the process liquid flow range, multiply the water flow range from the table by a factor D from below. SG 0.6 For liquid of 1.2 SG, the GMT411L flowmeter would have a full scale flow of 25 x 0.9 i.e 22m³/hr: the scale would be drawn 2-23 typically. Actual scale used would be rounded up, for example 2-23 in this case.
© TT Electronics plc Issue B 7/2017 Page 5 TT Electronics | Roxspur Measurement & Control Ltd www.roxspur.com | sales@roxspur.com General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Platon Metal Tube VA Gas or Liquid DS1220 Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. H owever, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation witho ut notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838 06HWAR0410 INSTALLATION 1. All AVA meters are designed for vertical installations, with flow upwards. It is necessary to have 5 straight pipe diameters upstream and 2 straight pipe diameters downstream. Bends in two places should be avoided. 2. The upstream and downstream pipe bores should suit the normal size of the instrument, if possible. 3. Ensure that no ferromagnetic material is situated within 100mm of the indicator. 4. Before installing the meter, the pipeline should be flushed to remove any foreign matter, or swarf, likely to collect on the float unit and magnet. 5. For ultimate protection a filter should be fitted upstream of the meter to remove large particles. Pipe Bore 15 25 50 80 100 A 51 45 42 42 39 B 48 51 66 87 100 C 250 250 250 300 400 D 51 49 49 75 113 E 26 34 27 N/A N/A F 27 41 60 N/A N/A DIMENSIONS