DS1100D5S MTU | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

1 100kVA/50 Hz/Standby (Fuel-Optimized) 380 - 4 15V A TOGNUM GROUP BRAND SYSTEM RATINGS➀ Standby DS01 100D5S DS01 100D5S DS01 100D5S Voltage (L-L) 380V 400V 4 15V Phase 3 3 3 PF 0.8 0.8 0.8 Hz 50 50 50 kW 880 880 840 kVA 1 100 1 100 1050 Amps 167 1 1588 146 1 Generator model 575RSL7074 575RSL7074 575RSL7074 Temp rise 150 °C/40 °C 150 °C/40 °C 150 °C/40 °C Connection 6 LEAD HI WYE 6 LEAD HI WYE 6 LEAD HI WYE // Industry-leading average load factor // Outstanding fuel economy // Optimized maintenance intervals // Low installation costs // Best-in-class reliability and availability // Lifting vertically or with diagonal pull // Compact design BENEFITS Optional equipment shown. Standard equipment may vary. ➀ Power available up to 40°C/400 m

// Engine Air fi lters Oil pump for draining Full fl ow oil fi lters Closed crankcase ventilation Jacket water pump Thermostats Exhaust manifold – dry Belt driven radiator fan Radiator – unit mounted Electric starting motor – 24V Governor – electronic isochronous Base – formed steel SAE fl ywheel & bell housing Charging alternator Flexible fuel connectors Flexible exhaust connection // Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor VDE 0530, IEC 60034-1, BS4999, BS5000, CSA22.2-100, AS 1359 Sustained short circuit current of up to 250% of the rated current for up to 10 seconds Self-ventilated and drip-proof IP23 Superior voltage waveform Digital, volts-per-hertz regulator No load to full load regulation Brushless alternator with brushless pilot exciter

4 Pole, rotating fi eld

150 °C maximum standby temperature rise Heavy duty shielded ball bearings with a minimum B-10 life of 40,000 hrs Flexible coupling Full amortisseur windings 3-phase voltage sensing ±0.25% voltage regulation 100% of rated load – one step according to NFPA 1 10 3% maximum harmonic content STANDARD EQUIPMENT➀ ➀ Represents standard product only. Consult Factory/MTU Onsite Energy distributor for additional confi gurations. // Engine-generator set is designed and manufactured in facilities certifi ed to standards ISO 9001:2008 and ISO 14001:2004 // Performance Assurance Certification (PAC) - Engine-generator set tested according to ISO 8528-5 for transient response - Verifi ed product design, quality and performance integrity - All engine systems are type and factory tested // Power Rating - Permissible average power output during 24 hours of operation up to 85% CERTIFICATIONS AND STANDARDS

// Engine Manufacturer MTU Model 16V2000G65TD Type 4-Stroke Arrangement 16-V Displacement: L (cu inch) 1.99 (12 1) Bore: mm (inch) 130 (5.1) Stroke: mm (inch) 150 (5.9) Compression ratio 16:1 Rated speed rpm 1500 Engine Governor Electronic isochronous Max power: kWm (bhp) 975 (1307) Speed regulation ±0.25% Air fi lter Dry // Lube Oil Capacity Total oil system: l (gal) 102 (27) // Electrical Electric Volts DC 24 Cold cranking amps under -17 .8 °C (0 °F) 1000 // Fuel System Fuel supply connection size M22x1,5 - 60°/Male Fuel return connection size M12x1,5 - 60°/Male Maximum fuel lift: m (ft) 5 (16) Recommended fuel see MTU fl uids & lubrication spec. Total fuel fl ow: l/hr (gal/hr) 600 (159) // Fuel Consumption➁ gal/hr l/hr g/kwh At 100% of power rating: 62 234 199 At 75% of power rating: 45 172 195 At 50% of power rating: 31 1 16 198 // Cooling/Radiator System Ambient capacity of radiator: °C 40 (optional 50) ➂ Max. restriction of cooling air, intake, and discharge side of rad.: kPa (in. H 20) 0,2 (0,803) Water pump capacity: l/min (gpm) 667 (176) Heat rejection to coolant: kW (BTUM) 420 (23,885) Heat rejection to after cooler: kW (BTUM) 200 (1 1,374) Heat radiated to ambient: kW (BTUM) 45 (2559) Engine coolant capacity: l (gal) 1 10 (29) Coolant to cooler temperature: °C (°F) 95 (203) // Air Requirements➃ Aspirating: m3/min (SCFM) 72 (2540) Air fl ow required for rad. cooled unit: m3/min 1236 (43606) // Exhaust System Gas temp. (stack): °C (°F) 535 (995) Gas volume fl ow temp: m 3/min (SCFM) 198 (6985) Maximum allowable back pressure: kPA 8,5 (34) APPLICATION DATA // The engine-generator set complies to G3 // Engine generator set tested according to ISO 8528-5 for transient response // Accepts rated load in one step as per NFPA 1 10 // All engine-generator sets are type and factory tested // MTU Onsite Energy is a single source supplier // Global product support // Cooling System (integral set-mounted; engine driven fan) // 16V2000 diesel engine (31,84 Liter (1943 cu inch) displacement; 4-stroke) // Engine-generator resiliently mounted // Complete range of accessories // Brushless, rotating fi eld generator (PMG excitation; 250% short circuit capability; 2/3 pitch stator windings) // Complete system metering // LCD display STANDARD FEATURES➀ ➀ Represents standard product only. Consult Factory/MTU Onsite Energy distributor for additional confi gurations. ➁ Values in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. ➂ System ratings at 50°C may differ. ➃ Air density = 1.184 kg/m3 (0.0739 lbm/ft3)

Subject to change. | 3236 1 1 1 | Edition 01/13 | VMC 2013-06. // Tognum Group Companies: Europe / Mediterranean / CIS / Middle East / Africa / MTU Friedrichshafen GmbH / 88040 Friedrichshafen / Germany / Phone + 49 754 1 90 77777 / Fax +49 754 1 90 77778 / info@mtu-online.com // North East Asia / South East Asia / China / Australia / Pacifi c / Tognum Asia Pte. Ltd. / 1 Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 686 1 5922 / Fax + 65 6264 384 1 / powergen2@mtu-online.com // USA / Canada / Mexico / Latin America / MTU Onsite Energy / 100 Power Drive / Mankato, MN 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergen3@mtu-online.com //www.mtuonsiteenergy.com WEIGHTS AND DIMENSIONS SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA // Consult your local MTU Onsite Energy distributor for emissions data. RATING DEFINITIONS AND CONDITIONS // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 55 14, AS 2789 and DIN 627 1. // Deration factor: Altitude: Consult your local MTU Onsite Energy distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy distributor for temperature derations. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 4691 x 1920 x 2226 mm (185 x 76 x 88 inch) 6388 kg (14,084 lbs) Materials and specifi cations subject to change without notice. Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specifi c engine-generator set. Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specifi c template drawings.