  • Ultra Slim Cases
  • 150% Peak Load for 4 seconds
  • Wide Output Adjustment Range
  • High Efficiency – Up to 92%
  • 12 V, 24 V & 48 V Versions
  • Low Output Ripple & Noise
  • -20 ºC to 70 ºC Operating Temperature DRS80-240 Series Input Input Voltage • 85-264 VAC Input Frequency • 47-63 Hz Input Current • 80 W: 2 A at 85 VAC

120 W: 2 A at 85 VAC

240 W: 4 A at 85 VAC

Inrush Current • 30 A max at 230 VAC Power Factor • DRS80 0.6 typical DRS120 & 240 0.95 typical Conforms to EN61000-3-2 Class A. Earth Leakage Current• 1.5 mA maximum Output Output Voltage • See table Output Voltage Trim • See table Initial Set Accuracy• ±1% at 50% load Minimum Load • No minimum load required Start Up Delay • 1 s maximum Start Up Rise Time • 20 ms typical Hold Up Time • 20 ms minimum at full load and 115 VAC Line Regulation • ±0.5% Load Regulation • ±1% Transient Response • 10% maximum deviation, recovering to less than 1% within 500 µs for 50% step load change at 0.2 A/µs Ripple & Noise • 100 mV pk-pk maximum, measured with

20 MHz BW

Overvoltage Protection• 12 V output: 16.5-18 V, 24 V output: 29-31.2 V, 48 V output: 57.6-62.4 V Overload Protection • 110-150% of rated current, constant current limit Short Circuit Protection• Trip and restart (hiccup mode) Temperature • ±0.02%/°C Coefficient xppower.com General Efficiency • See table Isolation • 3000 VAC Input to Output

1500 VAC Input to Ground

500 VDC Output to Ground

Switching Frequency • DRS80 60-300 kHz variable DRS120 & DRS240 100 kHz typical PFC & main converter Signals • DRS120 & 240: DC OK Volt free contacts MTBF • >200 kHrs to MIL HDBK217F Environmental Operating Temperature• -20 ºC to +70 ºC (see derating curves) Cooling • Natural covection Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -25 °C to +85 °C Shock • IEC68-2-6, 30 g, 11ms half sine, 3 times in each of 6 axes Vibration • IEC68-2-27, 10-500 Hz, 2 g 10 mins/sweep. 60 mins for each of 3 axes EMC & Safety Emissions • EN55022, class B conducted & radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, 4 KV Contact,

8 KV Air Discharge

Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Surge • EN61000-4-5, Installation Class 3 Perf Criteria B Conducted Immunity • EN61000-4-6, 3 V Perf Criteria A Dips & Interruptions• EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals • UL508, EN60950, UL1604 Pending

DRS80-240Models and Ratings Output Voltage Output Power Output Voltage Trim Output Current(1) Typical Efficiency(2) Model Number 12 V 72 W 12-15 V 6.0 A 89% DRS80US12 24 V 80 W 24-28 V 3.4 A 90% DRS80US24 48 V 80 W 48-56 V 1.7 A 91% DRS80US48 12 V 96 W 12-15 V 8.0 A 89% DRS120PS12 24 V 120 W 24-28 V 5.0 A 91% DRS120PS24 48 V 120 W 48-56 V 2.5 A 91% DRS120PS48 12 V 180 W 12-15 V 15.0 A 89% DRS240PS12 24 V 240 W 24-28 V 10.0 A 92% DRS240PS24 48 V 240 W 48-56 V 5.0 A 92% DRS240PS48 Notes 1. At nominal output voltage. Derate as output voltage increases. 2. At 230 VAC input, 100% load -20 0 10 20 30 40 50 60 70 100 Ambient Temp (˚C) Load (%) DRS80 & DRS120 -10 -20 0 10 20 30 40 50 60 70 100 Ambient Temp (˚C) Load (%) DRS240 L 1 6 DC Output AC Input 1 3 DC OK OVERLOAD W H 1 4 DC Output AC Input 1 3 DC OK OVERLOAD W H DRS120-240 DRS80 Pin Connections Conn Pin Designation AC Input

1 Neutral

2 Line

3 Ground

6 DC OK*

5 DC OK*

4 Negative

3 Negative

2 Positive

1 Positive

Model Sizes (inches/mm) Weight lbs (g) Wire sizes AWG (mm 2 )W L H DCOK DCOK DC OK Contact Rating: 0.3 A at 60 VDC

500 VDC isolation