DRF50US24-N1 XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Input 187-528 VAC 1Ø Adjustable Output High Peak Current Capability Overvoltage Protection Overcurrent Protection International Safety Approvals Input Input Voltage • 187-528 VAC single phase (264-746 DC) Input Frequency • 47-63 Hz Input Current • 1.1 A max @ 240 VAC Inrush Current • 25/50 A typical @ 240/480 VAC cold start +25 °C Power Factor • 0.98/0.93 typical at 240/480 VAC for DRF200 Leakage Current • 0.75 mA max (1.5 mA DRF200) Output Output Voltage • 24 VDC nominal Output Voltage • ±10% Adjustment Minimum Load • No minimum load required Start Up Time • 800 ms max with 240 VAC Hold Up Time • 10 ms (100 ms DRF200) typical at

240 VAC & 100% load

Drift • ±100 mV max Line Regulation • 96 mV max Load Regulation • 150 mV 0-100% load, 480 mV max 0-peak load Ripple & Noise • 680 mV pk-pk max 20 MHz bandwidth & 100% load Overvoltage • 115-150% of nominal rating, Protection recycle input to reset Overcurrent • >105% of peak current, Protection auto recovery Temperature • 0.04%/°C Coefficient Thermal Protection • Recycle input to reset General Efficiency • 82% typical at 240 VAC Isolation • 3000 VAC Input to Output

2000 VAC Input to Ground

500 VAC Output to Ground

Switching Frequency • 120 kHz PWM, 50 kHz PFC (DRF200) Environmental Operating • -10 °C to +70 °C (+60 °C DRF200) Temperature Contact Technical Sales for derating Storage • -20 °C to +75 °C Temperature Humidity • 20-90% non condensing Shock • 20 G, 11 ms once on the X axis Vibration • 2 G 10-55 Hz 3 axis EMC & Safety Emissions • EN55022 Level A conducted EN55022 Level A radiated ESD Susceptability • EN61000-4-2 Level 2 (Level 4 DRF200) Radiated • EN61000-4-3 Level 3 Susceptibility EFT/Burst • EN61000-4-4 Level 4 Surge • EN61000-4-5 Level 3 Safety Approvals • UL1950, cUL, EN60950, EN50178 50-200 Watts DRF Series AC-DC DIN Rail Specification THE XP ERTS IN POWER www.xpplc.com sales@xpplc.com

OUTPUT VOLTAGE & CURRENT RATINGS DRF 1. Peak current for 150 ms in every 30 second period. Only available with an input voltage of 240 to 528 VAC. Notes Mechanical Details www.xpplc.com sales@xpplc.com Output Output Current Model Voltage Nominal Peak(1) Number 21.6 - 26.4 V 2.1 A 6.7 A DRF50US24-N1 21.6 - 26.4 V 3.1 A 10.0 A DRF75US24-N1 21.6 - 26.4 V 8.4 A 42.0 A DRF200PS24-N1 Peak Loading Curves DRF50 Model Weight: <630g DRF75 Model Weight:<750g DRF200 Model Weight: <1700g NOTE: ( ) for DRF200 models t ≤ 150 ms, 30 s ≤ T (t ≤ 50 ms, 30 s ≤ T DRF200) Rev 3.0