DRC60 XPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
DRC60 Series AC-DC Power Supplies xxx Series www.xppower.com
- 60W convection cooled
- Compact low profile design
- UL/EN62368-1 approvals
- Class II operation
- Class B conducted & radiated emissions
- Universal input range 85 to 264VAC, 120 to 370VDC
- Adjustable output voltages from 5 to 48VDC
- High efficiency, up to 91%
- Input surge withstand 300VAC for 5s
- DC ‘ON’ LED indicator
- -30°C to +70°C operating temperature
- Full power to +45C
- 3 year warranty Dimensions: DRC60:
60 Watts
TheDRCrangeofcompactlightweightDINrailmountpowersuppliesisaconvenientandcosteffectivepowerconversionsolutionformany industrialandcommercialapplications.Withinternationalsafetycertification,anindustrialtemperaturerangeandclassBemissioncompliance, theDRCseriesalsofeaturesaDC“on”LED,wideoutputvoltageadjustmentrangeandalternativeDCinputrange. Models & Ratings Output Voltage Output Power Output Voltage Range(1) Output Current Ripple & Noise pk-pk Typical Efficiency(2) Maximum Capacitive Load Model Number 5V 33W 4.9 - 5.5V 6.5A 100mV 84% 20000μF DRC60US05 12V 54W 10.8 - 13.8V 4.5A 120mV 88% 10000μF DRC60US12 15V 60W 13.5 - 18.0V 4.0A 120mV 89% 8000μF DRC60US15 24V 60W 21.6 - 29.0V 2.5A 150mV 90% 4000μF DRC60US24 48V 60W 43.2 - 55.2V 1.25A 240mV 91% 680μF DRC60US48 Mechanical Details 0.197 (5.00) 2.047 (52.00) 0.394 (10.00) 2.283 (58.00) 3.648 (92.66) 3.543 (90.00) AC(N) AC(L) Output voltage adjustment DC on LED DRC60 xppower.com -Vo +Vo 1. All dimensions in inches (mm) 2. Weight: 0.39 lbs (175 g) 3. T olerance: ±0.039 in (±1.0 mm) 4. Screw terminal wire gauge: 12-24AWG 5. Connection screw maximum torque: 4.0 lbs-in (0.4 Nm) 6. Mounting rail type TS35 Notes Notes 1. Output power rating must not be exceeded. 2. Efficiency measured at 230V AC full load.
www.xppower.com 2 AC-DC Power Supplies Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 264 VAC See input voltage derating curve. Alternatively 120-370VDC(1) Input Frequency 47 50/60 63 Hz Input Current - Full Load 1.2/0.8 A 115/230 VAC Inrush Current 30/60 A At 115/230 VAC Input Protection Internal fuse fitted No Load Input Power 0.3/0.4 W Models below 48V output / 48V model output Input Surge 300 VAC Surge Withstand 300 General Characteristic Minimum Typical Maximum Units Notes & Conditions Isolation: Input to Output 4000 VAC Class II construction Switching Frequency 65 kHz Output LED Green LED to indicate output on Mean Time Between Failure 300 kHrs MIL-HDK-217F@25˚C Case Material Black plastic UL94V-0 rated Weight 0.39 (175g) lb (g) Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 4.9 55.2 VDC See Models and Ratings table Initial Set Accuracy ±2 % Output Voltage Adjustment See Models and Ratings table, output power rating must not be exceeded Minimum Load 0 A No minimum load required Capacitive Load μF See Models & Ratings table T ouch Current 0.25 mA rms At 264 VAC, 60 Hz Start Up Delay 3 s Rise time 4ms Hold Up Time 15/80 ms At full load and 115 VAC/230 VAC Line Regulation ±0.5 % Load Regulation ±1.5 % T ransient Response 4 % Max deviation recovering to within 2% in 2ms for a 50% load change. Ripple & Noise mV pk-pk Measured at 20 MHz bandwidth. See Models & Ratings table Overvoltage Protection 7. 5 V DRC60US05
16 DRC60US12
20 DRC60US15
36 DRC60US24
60 DRC60US48
Overload Protection 120 % Auto recovery Short Circuit Protection T rip and Restart (Hiccup Mode) T emperature Coefficient ±0.02 %/˚C Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating T emperature -30 +70 °C See thermal derating curve Storage T emperature -40 +85 °C Cooling Natural convection Operating Humidity 95 %RH Non-condensing Operating Altitude 2000 m Vibration and Shock T ested to GB/T2423.10-2008 and GB-T2423.22-2002 Note 1. DC input voltage was not assessed as part of the safety certification process.
www.xppower.com 06 Dec 2022 DRC60 Series AC-DC Power Supplies EMC: Emissions Phenomenon Standard Test Level Criteria Notes & Conditions Conducted EN55032 Class B Radiated EN55032 Class B Safety Approvals Safety Agency Safety Standard Notes & Conditions UL UL62368-1 TUV EN62368-1 CE Meets all applicable directives UKCA Meets all applicable legislation Temperature Derating -40 -20-30 0 10 20 70604030 Ambient temperature (°C) 100 Output power (%) -10 45 5/12/48V Blue 24V Red 15V Green Application Notes 100 Efficiency (%) 10 3020 40 50 60 100908070 Load (%) 5V Red other models Blue all 100 Efficiency (%) 5V Red other models Blue all 85 140115 160 180 200 264260240220 Input voltage Efficiency vs Load Input Voltage Derating Efficiency vs Input Voltage EMC: Immunity Phenomenon Standard Test Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 ±6 kV A Contact ±8 kV Air Discharge Radiated Immunity EN61000-4-3 10 V/m A EFT/Burst EN61000-4-4 ±2 kV A Surges EN61000-4-5 ±2 kV A Line to line Conducted EN61000-4-6 10 V rms A Dips EN61000-4-11 (220VAC) Dip. 100% (0VAC), 10ms Dip. 100% (0VAC), 20ms Dip. 60% (88VAC), 200ms Dip. 30% (154VAC), 500ms Dip. 20% (176VAC), 5000ms A Interrupt Int. 100% (0VAC), 5000ms B 1. Derating applies for start up below -30°C. Ripple & noise specifications may be exceeded. 85VAC/120VDC Input voltage 100 Output Power (%) 100VAC/140VDC 264VAC/370VDC For all models