DI3DINAV1 CARLOGAVAZZI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Specifications are subject to change without notice 1

  • 3-dgt µP-based for AC currents or voltages
  • Selectable CT/VT primary range
  • DIN-rail mounting
  • Degree of protection (front): IP 40 Product Description Ordering Key DI3-DIN AV5AD0XX 3-dgt µP-based meter with double input for AC currents or voltages. With 20 select- able CV/VT primary ranges. The housing is for DIN-rail mounting and ensures a degree of protection (front) of IP 40. Panel Meters and Controllers AC Ammeter or Voltmeter Type DI3-DIN AV1/AV5 Type Selection Power supply 50/60 Hz 1) 50/60 Hz 1) 50/60 Hz 1) 50/60 Hz (standard) Range code AV1: 1 A/100 V Standard cur- rent/voltage AV5: 5 A/500 V Standard cur- rent/voltage See Range Table 1) Power supply on request Operating temperature 0° to 50°C (32° to 122°F) (R.H. < 90% non-condensing) Storage temperature -10° to 60°C (14° to 140°F) (R.H. < 90% non-condensing) Insulation reference voltage 300 Vrms to ground Dielectric strength 4000 Vrms for 1 minute Noise rejection CMRR 100 dB, 40 to 60 Hz. EMC IEC 60801-2, IEC 60801-3, IEC 60801-4 (level 2), EN 50 081-1, EN 50 082-1 Safety standards EN 61 010-1, IEC 61010-1, VDE 0411 Connector Screw-type Housing Dimensions 89 x 53.5 x 58.5 mm (3-DIN modules) Material ABS, self-extinguish.: UL 94 V-0 Degree of protection Front: IP 40 Weight Approx 200 g Approvals CE, CSA General SpecificationsInput Specifications Rated input 5 A/500 VAC, 45 to 400 Hz (1 A/100 VAC on request) Overload protection Cont. Current: 1.2 x rated input Voltage: 1.2 x rated input For 1 s Current: 5 x rated input Voltage: 2 x rated input Accuracy Temperature drift ± 350 ppm/ºC Display 7-segment LED, h 14.2 mm, 3 digits Sampling rate 1 time/s Indication Max. 999 Min. 000 500 VAC range Scale suppressionup to 5% f.s. Other ranges Scale suppressionup to 3% f.s. Over range EEE Input range selection DIP-switch selectable Decimal point position DIP-switch selectable AC supply 230 VAC, -15% +10%, 50/60 Hz (standard)

24 VAC, 48 VAC, 115 VAC,

(on request) Power consumption 3.2 VA Supply Specifications

2 Specifications are subject to change without notice

54.5 49.5 58.5 53.5 Dimensions (mm) Wiring Diagrams V A Front Panel Description 1. Display 3-dgt (maximum read-out 999). Alphanumeric indication by means of 7-segment display for: - Displaying of the measured value, over-range. Range Connection Decimal point Resolution Voltage drop Input imp. Range code position ammeters voltmeters 1A/100 V Direct 1A Direct 100 V 999/99.9 1 mA/0.1 V 1 V 1 M Ω AV1 5A/500 V Direct 5A Direct 500 V 9.99/999 10 mA/1 V 250 mV 1 M Ω AV5 10 A CT10/1 A CT10/5 A 9.99 10 mA 1 V/250 mV AV1/AV5 15 A CT15/1 A CT15/5 A 99.9 100 mA 1 V/250 mV AV1/AV5 25 A CT25/1 A CT25/5 A 99.9 100 mA 1 V/250 mV AV1/AV5 40 A CT40/1 A CT40/5 A 99.9 100 mA 1 V/250 mV AV1/AV5 50 A CT50/1 A CT50/5 A 99.9 100 mA 1 V/250 mV AV1/AV5 60 A CT60/1 A CT60/5 A 99.9 100 mA 1 V/250 mV AV1/AV5 100 A CT100/1 A CT100/5 A 99.9 100 mA 1 V/250 mV AV1/AV5

150 A CT150/1 A CT150/5 A 999 1 A 1 V/250 mV AV1/AV5

220 V VT220/100 V 999 1 V 1 M Ω AV1

250 A CT250/1 A CT250/5 A 999 1 A 1 V/250 mV AV1/AV5

380 V VT380/100 V 999 1 V 1 M Ω AV1

400 A CT400/1 A CT400/5 A 999 1 A 1 V/250 mV AV1/AV5

500 A/V CT500/1 A VT500/100 V 999 1 A/V 1 V 1 M Ω AV1

500 A CT500/5 A 999 1 A 250 mV AV5

600 A/V CT600/1 A VT600/100 V 999 1 A/V 1 V 1 M Ω AV1

600 A CT600/5 A 999 1 A 250 mV AV5

1000 A/V CT1000/1 A VT1000/100 V 999 1 A/V 1 V 1 M Ω AV1

1000 A CT1000/5 A 999 1 A 250 mV AV5

IN NCNC INA IN VPower supply 1 2345 67 8 IN NCNC INA IN VPower supply Current measurements Direct C.T. 1 2345 67 8 IN NCNC INA IN VPower supply 1 2345 67 8 IN NCNC INA IN VPower supply Voltage measurements Direct V.T.