DHVC200-4061-S8-1236-R1 DURAKOOL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

HVDC Contactor 500A / 1000VDC Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DHVC200 03 Sep 25KS

  • 500A Continuous
  • Max. breaking current = 2000A
  • Magnet arc blowout
  • Auxiliary contact
  • Male or female power terminals
  • Side or bottom mount
  • Available with PWM coil economiser ü RoHS Compliant Contacts Ordering Code Contact arrangement SPST-NO-DM Contact material Oxygen Free Copper ( Cu. C10200) DHVC200 - 4 0 6 1 - S 8 - 1 2 3 6 - R 1 Max. switching voltage DC 1000VDC (current dependent - see fig. 1) Rated load (resistive, cos φ=1) DC1 200A Series Coil code: Max continuous thermal current DC1 500A with 300mm2, or larger, conductors See tables 1 & 230s 600A Contact material Instant peak current max. 5000A / 10msec 40: Cu. C10200 Max switching current 1 time only 2000A @ 320VDC Terminal temperature rise above ambient <70°C. IEC EN60947 GB14/14048.4 Contact voltage drop max. 80mV @ 200A Contact arrangement Auxiliary contact (when fitted) arrangement SPST-NO (1 Form A) 61: SPST-NO* max. current 2A @ 24VDC / 3A @ 125VAC 71: SPST-NO + Auxiliary* min. current 100mA @ 8V 81: SPST-NO Coil 91: SPST-NO + Auxiliary Nominal voltage DC 9 ~ 36VDC, 32 ~ 95VDC - see Tables 1 & 2 * Polarized - see Page 2 Rated power consumption hold 2W approx. Insulation Mounting & terminations Insulation resistance initial >1000MΩ @1000VDC Bottom mount life end 50MΩ (Min.) B8: M8 male stud power terminals Dielectric strength coil to contact 3000Vrms / <1mA / 1 min (at sea level) B9: M6 female power terminals contact to contact 1500Vrms / <1mA / 1 min (at sea level) Side mount General Data S8: M8 male stud power terminals Operating time at 20°C max. 30ms S9: M6 female power terminals Release time at 20°C max. 10ms Bounce time at 20°C max. 5ms Coil wire & auxiliary wire (when fitted) length Electrical life at rated load 10,000 operations @ 270VDC see page 2 R: 390mm Mechanical life 3 x 105 T: 150mm Environmental Ambient temperature operating -40 to +85°C Coil wire & auxiliary contact termination Relative humidity 20 to 90%RH 1: None (bare ends) Shock resistance 100G peak, 11ms 1/2 sine, peak 3: Mini-fit female (see Fig. 3) Vibration resistance 20G sine peak (80 to 2000Hz)  NB: UL ratings may differ and not all variants are UL approved. Contact Durakool for more information.Dimensions see Figs. 4 & 5 (Page 3) Weight approx. >450g (will vary according to option) E305753 

HVDC Contactor 500A / 1000VDC Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DHVC200 03 Sep 25KS Coil Data (with PWM economiser) Table 1. Coil code Nominal voltage (V DC) Us Coil operating range (V DC) Must operate voltage max. (V DC) Must release voltage (V DC) Starting current (A) Maintain (hold) current (A) 1236 9 ~ 36 9 ~ 36 8 ~ 9 5.5 ~ 7.0 3.8 0.18 @ 12V 0.09 @ 24V 3295 32 ~ 95 32 ~ 95 31 ~ 32 18.0 ~ 20.0 1.4 0.03 @ 48V PWM Coil economiser: no additional coil surge suppression required. Coil terminals are polarized. DHVC200 with coil code type 3295 is not UL approved. Coil Data (no PWM economiser) Table 2. Coil code Nominal voltage (V DC) Us Coil operatingrange (V DC) Must operate voltage (V DC) Must release voltage (V DC) Coil power (W) 1012 12 10.2 ~ 14.4 ≤ 9.0 ≥1.0 12 ~15 1024 24 20.4 ~ 28.8 ≤ 18.0 ≥ 2.0 12 ~15 1048 48 40.8 ~ 57.6 ≤ 36.0 ≥ 4.0 12 ~15 Only available with polarized power terminals - contact codes “61” & “71”. DHVC200 types without economiser are not UL approved. Electrical performance Fig. 1. Electrical life: Resistive load, polarized types only Electrical Life: Resistive load, non-polarized types only Connection Diagram Fig. 2. Optional Mini-fit Connector Fig. 3. Connector for coil & auxilary contact (x2) 1 = Coil lead terminal +ve (red) 2 = Coil lead terminal -ve (black) Auxilary contact leads = white Fitted socket type: SM-2A-HW Fitted terminal type: SMY-HW NB: Contact codes 81 & 91 Power terminals are not polarised Dimensions in mm 100000 10000 1000 100 100000 10000 1000 100 10 100 1000 100002001 10 100 200 1000 10000 Load current (A) Load current (A) Life (operations) Life (operations) Break only above 650A Break only above 650A 650 650 Recommended conductor size of 95mm2 and terminal temperature rise maximum in accordance with ISO (EN) 60947.1 70⁰C. Carry current is highly dependent upon conductor size. With 95mm2: 200A continuous, 300A 60m, 400A 20m, 800A 30s, 2000A 0.6s Life estimates are based on tests and extrapolated data. The user is advised to confirm the performance in their application.

HVDC Contactor 500A / 1000VDC Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DHVC200 03 Sep 25KS Dimensions - PWM type (with economiser) Fig. 4 Dimensions - No PWM type (no economiser) Fig. 5 Notes: 1: Polarity sensitive types 61 & 71: Observe contact polarity as indicated. Contactor life will be severely reduced if incorrectly connected. 2: The maximum make current is 650A to avoid contact welding. 4: Power contact (M8) nut torque = 8 ~ 10Nm, Power Contact (M6) nut torque = 6 ~ 8Nm; Installation/mounting torque = 1.7 ~ 3.5Nm. 5: Coil wire length and terminations can be customised upon request. 6. Coil and auxiliary contact wires: Teflon insulated UL1887 20AWG 7: Main contacts should be connected with cable section of more than 250mm², if used at maximum rated current. Bottom Mount - male terminals Bottom Mount - female terminals Side Mount - male terminals Side Mount - female terminals optional auxiliary contact leads shown A1+ A1+ Top view (male terminals) Top view (female terminals) optional auxiliary contact leads shown Bottom Mount - male terminals Bottom Mount - female terminals Side Mount - male terminals Side Mount - female terminals Top view (male terminals) Top view (male terminals) optional auxiliary contact leads shown optional auxiliary contact leads shown optional auxiliary contact leads shown A1+ A1+ M6 x 12 Hex Bolt M6 x 12 Hex Bolt M6 x 12 Hex Bolt M6x12