Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DM84 23 Feb 26KS

  • Cadmium - free contacts
  • Height 15.7 mm
  • 5000 V / 10mm Reinforced insulation
  • For PCB and plug-in sockets
  • Accessories: sockets and modules
  • AC and DC Coils
  • Recyclable packing Contacts Ordering Code Contact arrangement 2C/O, 2NO Contact material AgNi, AgNi/Au 5 um, AgSnO2 D M 8 4 - 3 0 1 2 - 2 5 - 1 0 1 2 Max. switching voltage AC 250V / 400V Min. switching voltage 5V AgNi, 5V AgNi/Au 5 um, 10V AgSnO2 Series Coil code: Rated load AC AC1:8A / 250V, AC15:3A /120V, 1.5A / 240V (B300) See table DC DC1:8A / 24V, DC13:0.22A/120V, 0.1A / 250V (R300)Contact material 1 & 2 Min. switching current 5mA AgNi, 2mA AgNi/Au 5um, 10mA AgSnO2 20: AgNi Max. inrush current 15A AgSnO2 23: AgNi/Au 5m Rated current 8A 30: AgSnO2 Max. breaking capacity AC1 2000VA Min. breaking capacity 0.3W AgNi, 0.05W AgNi/Au 5 um, 1W AgSnO2 Contact arrangement Initial resistance ≤ 100 mΩ max, at 0.1A/24VDC 12: 2C/O Max. operating frequency at rated load AC1 600 cycles/hour 21: 2NO no load AC1 72,000 cycles/hour Coil Environmental protection Must release voltage AC/DC AC ≥ 0.15Un, DC ≥ 0.1Un 3: In cover, IP67 (waterproof) Operating range See tables 1, 2 and figures 4, 5 Insulation EN60664-1 5: For PCB and sockets Insulation category C250 / B400 Insulation rated voltage 400 VAC Rated surge voltage 4,000 VAC 1.2/50µs Overvoltage category III IEC 61810-5 (PN-IEC 664-1) Insulation pollution degree 3 Dieletric strength coil to contact 5,000VAC contact to contact DPDT:1,000 VAC, DPST-NO:2,000VAC (special) pole to pole 2,500VAC Contact - coil distance clearance & creepage ≥ 10mm Contact gap ≥ 0.35mm General Data Operating / Release time typ. 7ms / 3ms cosφ See figure 2 DC L/R=40 ms > 105 0.15 A, 220VDC Mechanical life ops. > 3 x 107 Environmental Environmental protection RTII IEC 61810-7 Cover protection IP40 or IP67 Solder bath temperature / time max. 270°C / 5s Ambient temperature operating AC -40 to +70°C, DC -40 to +85°C Notes: For AC loads this relay is designed for 50-60Hz standard industrial power and was tested according to AC1 category as defined by the IEC 60947-1 standard, covering low-frequency switchgear (typically 50-60 Hz). Operating at higher frequencies, places the component outside its certified utilisation category, invalidating all safety certifications (CE, UL, etc.) and manufacturer performance guarantees. storage -40 to +85°C Shock resistance 20g Vibration resistance (NO/NC) 10g / 5g 10...150 Hz Dimensions L x W x H 29 x 12.7 x 15.7mm Weight approx. 14g ü RoHS Compliant E305753

Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DM84 23 Feb 26KS DC Coil Data Table 1 Coil code Rated voltage (VDC) Coil resistance Ω ±10% (at 20°C) Coil operating voltage range (VDC@ 20°C) min. max. 1003 3 22 2.1 7.6 1005 5 60 3.5 12.7 1006 6 90 4.2 15.3 1009 9 200 6.3 22.9 1012 12 360 8.4 30.6 1018 18 710 12.6 45.9 1024 24 1440 16.8 61.2 1036 36 3140 25.2 91.8 1048 48 5700 33.6 122.4 1060 60 7500 42.0 153.0 1110 110 25200 77.0 280.0 Standard coil rated voltages marked with bold type AC Coil Data - 50/60Hz Table 2 Coil code Rated voltage (VAC) Coil resistance Ω ±10% (at 0°C) Coil operating voltage range (VAC@ 20°C) min. max. 5012 12 100 9.6 13.2 5024 24 400 19.2 28.8 5048 48 1550 38.4 57.6 5060 60 2600 48.0 72.0 5110 110 8900 88.0 132.0 5115 115 9600 92.0 138.0 5120 120 10200 96.0 144.0 5220 220 35500 176.0 264.0 5230 230 38500 184.0 276.0 5240 240 42500 ±15% 192.0 288.0 Standard coil rated voltages marked with bold type Connection Diagrams (pin side view) Fig. 2Dimensions mm Fig. 1 Terminal (pin) A1 (1); A2 (2) 22(3); 21(4): 24(5): 12(6); 11(7);14(8) mm Ø0.6 0.5 x 0.9 Drilling hole:

  • for relays Ø1.3 + 0.1mm
  • for sockets Ø1.5 + 0.1mm PCB Layout (solder side view) Fig. 3

Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DM84 23 Feb 26KS Electrical life at AC resistive load. Switching frequency: 600 Cycles per hour Fig. 4 Electrical life reduction factor at AC inductive load Fig. 5 Max. DC resistive load breaking capacity Fig. 6 Coil operating range DC Fig. 7 Coil operating range AC 50Hz Fig. 8 Relay mounting Relays DM84 are designed for:

  • Direct PCB mounting by soldering
  • DIN Rail, or panel mounting, screw terminal plug-in sockets, D14F-2Z-C* with clip JH-15PS. LED indicator & protecting modules DM***-BK are available for D14F-2Z-C* sockets
  • Plug-in sockets for PCB mounting D14F-2Z-A1 or D14F-2Z-A2 with clip JH-15PS Description of Fig. 7 and 8 A - relations between make voltage and ambient temperature at no load on contacts. Coil temperature and ambient temperature are equal before coil energizing. Make voltage is not higher than the value read on Y axis (multipli- cation of rated voltage). B - relations between make voltage and ambient temperature after initial coil heating up with 1.1 Un, at continuous load of I on contacts. Make voltage is not higher than the value read on Y axis (multiplication of rated voltage). 1, 2, 3 - values on Y axis represent allowed overvoltage on coil at certain ambient temperature and contact load: 1 - no load 2 - 50% of rated load 3 - rated load