DG05-3021-35-1005 DURAKOOL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DG05 23 Feb 26KS

  • Miniature pcb power relay
  • Up to 16A /30VDC or 250VAC Rating
  • Industry standard style
  • 200mW or 450mW Coil options ü ROHS Compliant Contacts Ordering Code Contact arrangement SPST-NO (1 Form A) Contact material AgSnO2, AgSnO2In2O3* D G 0 5 - 3 0 2 1 - 3 5 - 1 0 0 5 Max. switching voltage AC/DC 250VAC / 30VDC Min. switching current / voltage 100mA/12VDC Series Coil code: Max. switching power 2500VA / 300W: 4000VA / 480W See tables Rated load AC1 10A / 250VAC, 16A / 250VAC (AgSnO2In2O3)* Contact material 1 & 2 DC1 10A / 30VDC, 16A / 30VDC (AgSnO2In2O3)* 30: AgSnO2 (10A) Initial resistance ≤ 50mΩ, max. at 0.1A/6VDC 70: AgSnO2In2O3 (16A)* Coil Rated voltage DC 3...24V (3V not UL approved) Contact arrangement Must release voltage ≥ 0.1Un 21: SPST-NO (1 N/O) Operating range See tables 1 & 2 Rated power consumption DC 200mW (Sensitive Coil) / 450mW (Standard Coil) Environmental protection IP67 Insulation 3: In cover, sealed Insulation resistance 1000MΩ at 500VDC, 50%RH Tracking resistance CTI 250 Mounting & terminations Dielectric strength 10A: coil to contact 4000Vrms 50/60Hz, 1min 5: For PCB 16A: coil to contact 3600Vrms 50/60Hz, 1min contact to contact 1000Vrms 50/60Hz, 1min Surge resistance coil to contact 10,000V / 1.2x50 µs General Data Operating time (excluding bounce) typ. ≤ 6ms (200mW Coil), ≤ 10ms (450mW Coil) Release time (excluding bounce) typ. ≤ 5ms Electrical life 10A ops. ≥ 1 x 105 (resistive), max. 30 ops. per minute 16A ops. ≥ 5 x 104 (resistive), max. 6 ops. per minute Mechanical life ops. ≥ 1 x 107 (no load), max. 300 ops. per minute Environmental Ambient temperature operating / storage -40 to +85°C Notes: *UL pending on 16A variant For AC loads this relay is designed for 50-60Hz standard industrial power and was tested according to AC1 category as defined by the IEC 60947-1 standard, covering low-frequency switchgear (typically 50-60 Hz). Operating at higher frequencies, places the component outside its certified utilisation category, invalidating all safety certifications (CE, UL, etc.) and manufacturer performance guarantees. Shock resistance functional / destructive 10g / 100g Vibration resistance DA 1.5mm 10-55Hz Flammability class UL 94V-0 Dimensions L x W x H 18.3 x 10.2 x 15.2mm Weight approx. ~7g E305753

Specifications are subject to change without notice. E&OE.See website for contact details: www.durakool.com DG05 23 Feb 26KS Overall Dimensions mm Fig. 1 Coil Data (450mW) Table 1 Coil code Nominal voltage (VDC) Coil resistance (Ω) ±10% Must operate voltage max. (VDC) Must release voltage min. (VDC) Allowable voltage (VDC) 10031 3 20 2.25 0.30 3.9 1005 5 55 3.75 0.50 6.5 1006 6 80 4.50 0.60 7.8 1009 9 180 6.75 0.90 11.7 1012 12 320 9.00 1.20 15.6 1024 24 1280 18.00 2.40 31.2 1 3VDC Coil not UL approved. Coil Data (200mW) Table 2 Coil code Nominal voltage (VDC) Coil resistance (Ω) ±10% Must operate voltage max. (VDC) Must release voltage min. (VDC) Allowable voltage (VDC) S0031 3 45 2.25 0.30 3.9 S005 5 125 3.75 0.50 6.5 S006 6 180 4.50 0.60 7.8 S009 9 400 6.75 0.90 11.7 S012 12 720 9.00 1.20 15.6 S024 24 2800 18.00 2.40 31.2 1 3VDC Coil not UL approved. DG05-3021-35-1012 10A 250VAC 10A 30VDC 0.4 1.0 1.0 15.5 0.3 10.218.2 0.3 0514 7.6 12.7 2.51.5 Bottom View Dimensions in mm Tolerances: < 1mm: ±0.2 1 ~ 5mm: ±0.3 > 5mm: ±0.5 18.3 15.2