Specifications are subject to change without notice (10.12.2020) 1 Proximity Sensors Capacitive Thermoplastic Polyester Housing

  • 4TH Generation TRIPLESHIELDTM
  • Adjustable sensing distance: 2 - 10 mm Flush or 3-15 mm Non-flush
  • Protection: short-circuit, transients and reverse polarity
  • Dust and humidity compensation
  • Dust or Temperature alarm output
  • Rated operational voltage: 10-40 VDC
  • Output: DC 200 mA, NPN or PNP
  • Standard Output: NO and NC
  • LED indications for Power-supply, Target and Stability
  • IP67, IP68, IP69K, Nema 1, 2, 4, 4X, 5, 6, 6P, 12
  • Cable and M12 connector versions available Product Description The CA18CA.. capacitive proximity switches feature an improved 4 TH Genera - tion TRIPLESHIELDTM tech - nology. Furthermore, these sensors feature increased immunity to electromagnetic interference (EMI), especial - ly to frequency drives. Not only does 4 TH Generation TRIPLESHIELDTM feature an increased EMI, but it also increases the immuni - ty to humidity and dust. The implementation of stability indication eases the setup procedure as both Stable ON and Stable OFF positions are indicated by the green and yellow LEDs. The sensing distance is increased by 25 % allowing room for additional stable detection. The Dust Alarm function gives an early warning that the sensing surroundings have to be cleaned. The Temperature alarm func- tion raises an alarm if the sensing surface goes beyond 60 degree Celcius. The sensor housing is featur- ing IP69K as well as approval by ECOLAB for cleaning- and disinfection agents. Rated operating distance (Sn) Non-flush mounted sensor 0 - 12 mm (factory setting 12 mm), (ref. target 36x36 mm ST37, 1 mm thick, grounded) Flush mounted sensor 0 - 8 mm (factory setting 8 mm - non-flush mounted) (ref. target 24x24 mm ST37, 1 mm thick, grounded) Specifications EN 60947-5-2 Ordering Key Capacitive prox im ity switch Housing diameter (mm) Housing material Housing length Detection principle Rated operating dist. (mm) Output type Output configuration Connection type CA18CAN12NAM1 Housing Sensor Output Output Connection Rated operating Ordering no. Ordering no. Ordering no. diameter type type function distance (Sn) Standard Dust alarm Temperature alarm M 18 Flush NPN NO+NC Cable 0 - 8 mm CA18CAF08NA M 18 Flush NPN NO+NC M12 Plug 0 - 8 mm CA18CAF08NAM1 M 18 Flush PNP NO+NC Cable 0 - 8 mm CA18CAF08PA M 18 Flush PNP NO+NC M12 Plug 0 - 8 mm CA18CAF08PAM1 M 18 Flush PNP NO Cable 0 - 8 mm CA18CAF08PODU1) CA18CAF08POTA 1) M 18 Flush PNP NC Cable 0 - 8 mm CA18CAF08PCDU1) CA18CAF08PCTA 1) M 18 Non-Flush NPN NO+NC Cable 0 - 12 mm CA18CAN12NA M 18 Non-Flush NPN NO+NC M12 Plug 0 - 12 mm CA18CAN12NAM1 M 18 Non-Flush PNP NO+NC Cable 0 - 12 mm CA18CAN12PA M 18 Non-Flush PNP NO+NC M12 Plug 0 - 12 mm CA18CAN12PAM1 M 18 Non-Flush PNP NO Cable 0 - 12 mm CA18CAN12PODU2) CA18CAN12POTA 2) M 18 Non-Flush PNP NC Cable 0 - 12 mm CA18CAN12PCDU2) CA18CAN12PCTA 2) 1) Replaced by CA18CAF08BPA2IO 2) Replaced by CA18CAN12BPA2IO Type Selection

2 Specifications are subject to change without notice (10.12.2020) Specifications (cont.) EN 60947-5-2 Sensitivity control Adjustable by potentiometer Electrical adjustment 11 turns Mechanical adjustment 16 turns Adjustable distance Flush types 2 to 10 mm Non-flush types 3 to 15 mm Effective operating dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x Sn Usable operating dist. (Su)* 0.85 x Sr ≤ Su ≤ 1.15 x Sr Repeat accuracy (R) ≤ 5% Hysteresis (H) 3 - 20% Rated operational volt. (UB) 10 to 40 VDC (ripple incl.) Ripple ≤ 10% Output function NPN or PNP Output switching function N.O. and N.C. Rated operational current (Ie) ≤ 200 mA (continuous) Capacitive load 100 nF No-load supply current (Io) ≤ 12 mA Voltage drop (Ud) ≤ 2.0 VDC @ 200 mA DC Minimum operational current (Im) ≥ 0.5 mA OFF state current (Ir) ≤ 100 μA Protection Short-circuit, reverse polarity, transients Frequency of operating cycles (f) 50 Hz Response time OFF-ON (ton) ≤ 10 ms Response time ON-OFF (toff) ≤ 10 ms Power ON delay (tv) ≤ 200 ms Indication Target detected LED, yellow Power and detection stability LED, green Environment Installation category III (IEC 60664, 60664A; 60947-1) Degree of pollution 3 (IEC 60664, 60664A; 60947-1) Degree of protection IP 67, IP 68/60 min., IP69K (IEC 60529; 60943-1) NEMA type 1, 2, 4, 4X, 5, 6, 6P, 12 Operating temperature -30 to +85°C ( -22 to +185°F) Max. temperature on sensing face 120°C (248°F) Storage temperature -40 to +85°C (-40 to +185°F) Rated insulation voltage 1 kVAC (rms) IEC protection class III Tightening torque ≤ 2.6 Nm Connection Cable PVC, Ø5.2 x 2 m, 4 x 0.34 mm2 Oil proof, grey Plug (M1) M12 x 1 - 4 pin Temperature alarm output 60ºC ± 5ºC Response time examples TA = 25°C 14 sec @ TEXC = 800°C 315 sec @ TEXC = 80°C TRIPLESHIELDTM Exceeding the norms for capacitive sensors Electrostatic discharge (EN61000-4-2) Contact discharge > 40 kV Air discharge > 40 kV Electrical fast transients/burst Surge (EN 61000-4-5) Power-supply > 2kV (with 500 Ω) Sensor output > 2kV (with 500 Ω) Wire conducted disturbances (EN 61000-4-6) > 20 Vrms Power-frequency magnetic fields (EN 61000-4-8) Continous > 60 A/m, 75.9 µ tesla Short-time > 600 A/m, 759 µ tesla Radiated RF electromagnetic fields (EN 61000-4-3) > 20 V/m Shock (IEC 60068-2-27) 30 G / 11ms, 3 pos, 3 neg per axis Rough handling shocks (IEC 60068-2-31) 2 times from 1m 100 times from 0,5m Vibration (IEC 60068-2-6) 10 to 150 Hz, 1 mm / 15 G Housing material Body PBT, grey, 30% glass reinforced Cable gland PA12, black Fingernuts PA12, black Trimmershaft Nylon Weight Cable version 150 g Plug version 75 g Approvals cULus (UL508), ECOLAB CE-marking Yes MTTFd 825 years @ 40°C (+104°F) The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications. The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning. The sensor is exposed to high pressure water from a spray nozzle that is fed with 80°C water at 8’000– 10’000 KPa (80–100bar) and a flow rate of 14–6L/min. The nozzle is held 100 –150 mm from the sensor at angles of 0°, 30°, 60° and 90° for 30s each. The test device sits on a turntable that rotates with a speed of 5 times per minute. The sensor must not suffer any damaging effects from the high pressure water in appear - ance and function. 90° 60° 30° * For Flush type sensor flush mounted in conductive material, the usable operating distance (Su) is 0.80 x Sr ≤ Su ≤ 1.2 x Sr for temperatures exceeding 0 - 60 °C ( 32 - 140°F).

Specifications are subject to change without notice (10.12.2020) 3 The environments in which capacitive sensors are installed can often be unsta - ble as regards temperature, humidity, object distance and industrial (noise) interference. That is why Carlo Gavazzi offers as standard features in all TRIPLESHIELD TM capac - itive sensors a user-friendly sensitivity adjustment instead of a fixed sensing range. Like- wise, these sensors provide an extended sensing range to accommodate mechanically demanding areas and tem - perature stability to ensure high immunity to electromag- netic interference (EMI) and a minimum need for adjusting sensitivity, if the temperature varies. Note: The sensors are factory set (default) to nominal sensing range Sn.Sn. Adjustment Guide Wiring Diagram NPN BN BK WH BU 10 - 40 VDC 200 mA PNP BN BK WH BU 10 - 40 VDC 200 mA PNP Dust- or Temperature alarm on NC BN BK WH (DU/TA) BU 10 - 40 VDC 200 mA PNP Dust- or Temperature alarm on NO 10 - 40 VDC 200 mA BN BK WH (DU/TA) BU Detection Diagram Y X Sensor Target -25 -20 -15 -10 -8 -4 -2 0 2 6 8 10 12 144 -0,31 -0,24 -0,16 0 0,08 0,24 0,31 0,39 0,47 0,55 -0,98 -0,79 -0,59 -0,39 -0,20 0,00 0,20 0,39 0,59 0,79 0,98 0,16-0,08 -25 -20 -15 -10 -8 -4 -2 0 2 6 8 10 12 144 -0,31 -0,24 -0,16 0 0,08 0,24 0,31 0,39 0,47 0,55 -0,98 -0,79 -0,59 -0,39 -0,20 0,00 0,20 0,39 0,59 0,79 0,98 0,16-0,08 Flush Non-flush Distance (mm) Distance (mm) (mm) (mm) Distance (inch) Distance (inch) (inch) (inch) Sensor head Sensor head

4 Specifications are subject to change without notice (10.12.2020) Dimensions PlugCable Colour code

1 Brown

2 White

3 Blue

4 Black

CA18CAF.... M18 x 1.0 x 55 LED CA18CAF....M1 M18 x 1.0 x 55 15 M12 x 1.0 LED CA18CAN.... M18 x 1.0 x 47 8 15 LED CA18CAN....M1 M18 x 1.0 x 47 8 15 M12 x 1.0 LED DIST. OUTPUT STABLE Yellow LED Sensitivity adjustment Green LED The back of the sensor Detection Stability Indication Dust alarm NC >1 sec. >1 sec. >1 sec. >2 sec. Dust alarm NO >1 sec. >1 sec. >1 sec. >2 sec. Output NC Output NO Yellow LED ON Green LED ON Stable OFF Output OFF Output ON Stable ON Time Target influence

Specifications are subject to change without notice (10.12.2020) 5 Installation Hints Capacitive sensors have a unique ability to detect al- most any material in li quid or solid form. Capa ci tive sen - sors are able to detect me- tallic as well as non-metallic ob jects. How ever, their tradi- tional use is for non-metallic materials such as:

  • Plastics Industry Resins, regrinds or mould- ed products.
  • Chemical Industry Cleansers, fertilizers, liq - uid soaps, corrosives and pe t ro chemicals.
  • Wood Industry Saw dust, paper products, door and window frames.
  • Ceramics & Glass Industry Raw materials, clay or finish ed products, bottles.
  • Packaging Industry Package inspection for lev- el or contents, dry goods, fruits and vegetables, dairy products. Materials are detected due to their dielectric constant. The bigger the size of an object, the higher the density of ma- terial, the better or easier it is to detect the object. The nominal sensing di stan- ce for a capaci tive sensor is refe r red to a grounded me tal plate (ST37). For addi- tional information regarding di elec tric ratings of materi- als please re fer to Technical Information. Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/ current peaks, separate the prox. switch pow- er cables from any other power cables, e.g. motor, contactor or solenoid cables Not correct Correct The cable should not be pulled A proximity switch should not serve as a mechanical stop Any repetitive flexing of the cable should be avoided Delivery Contents
  • User manual
  • 2 x M18 fingernuts
  • Screwdriver
  • Packaging: Cardboard box Accessories
  • Connector type CONB14NF-... -series.
  • Mounting Brackets AMB18-S.. (straight), AMB18-A.. (angled)