DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

DE (ADE) 1ds_61A01_en_de: 100811D SPECIFICATIONS COMPACT HIGH-INSULATION POLARIZED POWER RELAY DE RELAYS (ADE) VDE mm inch 12.5 .492 25.0 .984 12.5 .492

FEATURES

  • Conforms to European safety standards (VDE0700 and VDE0631) Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch Creepage distance Min. 8mm .315 inch
  • Extensive product line-up
  • Surge voltage between contact and coil 12 kV
  • Low operating power Nominal operating power at 200 mW (Single side stable, 2 coil latching)
  • Compact body saves space Size: 12.5(W)  25.0(L)  12.5(H) mm
  • UL/CSA, VDE approved Contact Coil (at 20C, 68F) Characteristics Arrangement 1 Form A 1 Form A

1 Form B 2 Form A

Contact material AgSnO 2 type Initial contact resis- tance, max. (By voltage drop 6V DC 1A) 30m Rating (resistive load) Nominal switching capacity 10A 250V AC, 10A 30V DC 8A 250V AC, 8A 30V DC 8A 250V AC, 8A 30V DC Max. switching power 2,500 VA*, 300W 2,000 VA*, 240W 2,000 VA*, 240W Max. switching voltage 440V AC, 230V DC 440V AC, 230V DC 440V AC, 230V DC Max. switching current Min. switch- ing capac- ity 100 mA, 5 V DC Expected life (min. operations) Mechanical (at 300cpm) 10 Electrical (at 20 cpm) (resistive load) 105 105(AC) 5  104(DC) Electrical (16A / 230 V AC resistive)* 25000 20000 Nominal operating power Single side stable 200 mW 1 coil latching 100 mW 2 coil latching 200 mW Max. operating speed 20 cpm (at rated load) Initial insulation resistance*1 Min. 1,000 M (at 500 V DC) Initial breakdown voltage* Between open contacts 1,000 Vrms Between contact sets 4,000 Vrms (2 Form A,

1 Form A 1 Form B)

Between contact and coil 5,000 Vrms Surge voltage between contact and coil*3 Min. 12,000 V (initial) Operate time [Set time]*4 Max. 10ms (typ. 5ms) [Max. 10ms (typ. 4ms)] (at 20C 68F) Release time (without diode) [Reset time]*4 Max. 5ms (typ. 2ms) [Max. 10ms (typ. 4ms)] (at 20C 68F) Temperature rise (at 70C)*5 Max. 50C Shock resistance Functional*6 Min. 196 m/s2{20 G} Destructive*7 Min. 980 m/s2{100 G} Vibration resistance Functional*8 10 to 55 Hz at double amplitude of 2 mm Destructive 10 to 55 Hz at double amplitude of 3 mm Conditions for operation, transport and storage*9 (Not freezing and condens- ing at low temperature) Ambient temp. –40C to 70C –40F to 158F Humidity 5 to 85% R.H. Unit weight Approx. 7 g .25 oz #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Remarks * 16A possible for one contact set only with max. 4000 VA switching power. 1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA *3 Wave is standard shock voltage of 1.2  50s according to JEC-212-1981 *4 Nominal operating voltage applied to the coil, excluding contact bounce time. *5 By resistive method *6 Half-wave pulse of sine wave: 11ms, detection time: 10ms. *7 Half-wave pulse of sine wave: 6ms *8 Detection time: 10ms *9 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.

DE (ADE) 2 ds_61A01_en_de: 100811D TYPES AND COIL DATA (at 20C 68F)

  • Single side stable type

1 Form A, 1 Form A 1 Form B, 2 Form A

  • 1 coil latching type

1 Form A

  • 2 coil latching type

Note: Insert contact arrangement, e.g.1a, 1a1b, 2a, in  for contact form required. Part No. Nominal voltage, V DC Pick-up voltage, V DC (max.) (initial) Drop-out voltage, V DC (min.) (initial) Coil resistance,  (10%) Nominal operating current, mA (10%) Nominal operating power, mW Max. allowable voltage, V DC DE-3V 3 2.1 0.3 45 66.6 200 3.9 DE-5V 5 3.5 0.5 125 40 200 6.5 DE-6V 6 4.2 0.6 180 33.3 200 7.8 DE-9V 9 6.3 0.9 405 22.2 200 11.7 DE-12V 12 8.4 1.2 720 16.6 200 15.6 DE-24V 24 16.8 2.4 2,880 8.3 200 31.2 DE-48V 48 33.6 4.8 11,520 4.2 200 62.4 Part No. Nominal voltage, V DC Set voltage, V DC (max.) (initial) Reset voltage, V DC (min.) (initial) Coil resistance,  (10%) Nominal operating current, mA (10%) Nominal operating power, mW Max. allowable voltage, V DC DE-L-3V 3 2.1 2.1 90 33.3 100 3.9 DE-L-5V 5 3.5 3.5 250 20 100 6.5 DE-L-6V 6 4.2 4.2 360 16.7 100 7.8 DE-L-9V 9 6.3 6.3 812 11.1 100 11.7 DE-L-12V 12 8.4 8.4 1,440 8.3 100 15.6 DE-L-24V 24 16.8 16.8 5,760 4.2 100 31.2 Part No. Nominal voltage, V DC Set voltage, V DC (max.) (initial) Reset voltage, V DC (min.) (initial) Coil resistance,  (10%) Nominal operating current, mA (10%) Nominal operating power, mW Max. allowable voltage, V DCSet coil Reset coil Set coil Reset coil Set coil Reset coil DE-L2-5V 5 3.5 3.5 125 125 40 40 200 200 6.5 TYPICAL APPLICATIONS

  • Temperature controller
  • Automatic meter reading
  • OA equipment
  • FA equipment

ORDERING INFORMATION

Product name Contact arrangement Operating function Coil voltage, V DC DE 1a: 1 Form A 1a1b: 1 Form A 1 Form B 2a: 2 Form A Nil: Single side stable L: 1 coil latching L2: 2 coil latching 1.5, 3, 4.5, 5, 6, 9, 12, 24, 48 DE 1a L 3Ex. Notes: 1) Standard packing; Carton (tube package) 20 pcs. Case 500 pcs. 2) UL/CSA, VDE approved type is standard. V just for single side stable

DE (ADE) 3ds_61A01_en_de: 100811D DIMENSIONS(mm inch) Download from our Web site.CAD DataCAD Data CAD Data Single side stable 1 coil latching type 2 coil latching type Tolerance: 0.3 .012 0.5 dia .020 dia 25.0 .984 12.5 .492 7.62 .300 3.5 .138 2.44 .09615.24 .600 0.8 .032 0.8 .032 0.4 .016 1.0 .039 7.62 .300 12.0 .472 0.5 .020 0.5 dia .020 dia 0.5 dia .020 dia 3.5 .138 2.44 .096 0.8 .032 0.8 .032 1.0 .039 0.5 .020 25.0 .984 12.0 .472 12.70 .500 7.62 .300 2.54 .100 12.5 .492 7.62 .300 0.4 .016 PC board pattern (Bottom view) Single side stable 1 coil latching type 2 coil latching type Tolerance : 0.1 .004 7.62 .300 15.24 .600 6-1.2 dia 6-.047 dia 7.62 .300 8-1.2 dia 8-.047 dia 7.62 .300 12.70 .500 7.62 .300 2.54 .100 Schematic (Bottom view) Single side stable (1 Form A) (5,6: dummy terminal) (1 Form A 1 Form B) (Deenergized condition) (2 Form A) 431 86 5 86 5 13 4 86 5 13 4 1coil latching type (1 Form A) (5,6: dummy terminal) (1 Form A 1 Form B) (Reset condition) (2 Form A) 86 5 13 4 86 5 13 4 2coil latching type (1 Form A) (5,6: dummy terminal) (1 Form A 1 Form B) (Reset condition) (2 Form A) 432 4321 87 6 5 5678 432

DE (ADE) 4 ds_61A01_en_de: 100811D REFERENCE DATA 1. Max. switching power 2. Life curve Contact voltage Current, A No. of operations Contact load, A 3.-(1) Coil temperature rise (1 Form A) Tested sample: ADE109 Quantity: n=6 Ambient temperature: 25C to 70C 77F to 158F 3.-(2) Coil temperature rise (1 Form A 1 Form B) Tested sample: ADE309 Quantity: n=6 Ambient temperature: 25C to 70C 77F to 158F 3.-(3) Coil temperature rise (2 Form A) Tested sample: ADE209 Quantity: n=6 Ambient temperature: 25C to 70C 77F to 158F 8070 90 100 110 120 130 10A 10A 25°C 70°C 77°F 158°F Coil applied voltage, %V T emperature rise, °C 8070 90 100 110 120 130 25°C 70°C 77°F 158°F Coil applied voltage, %V T emperature rise, °C 8070 90 100 110 120 130 25°C 70°C 77°F 158°F Coil applied voltage, %V T emperature rise, °C 4-1. Operate/release time (1 Form A) Tested sample: DE1a-5V Quantity: n=5 4-2. Operate/release time (1 Form A 1 Form B) Tested sample: DE1a1b-5V, Quantity: n=5 4-3. Operate/release time (2 Form A) Tested sample: DE2a-5V, Quantity: n=5 8070 90 100 110 120 130 10A 10A 25°C 70°C 77°F 158°F Coil applied voltage, %V T emperature rise, °C Min. Min. Max. Max. Min. Max. 70 80 90 100 110 120 130 Operate/release time, ms Operate time Release time (With diode) Coil applied voltage, %V Release time x x x Min. Min. Max. Min. Max. Max. 70 80 90 100 110 120 130 Operate/release time, ms Operate time Release time (With diode) Coil applied voltage, %V Release time x x x 5-1. Ambient temperature characteristics (1 Form A) Tested sample: DE1a-5V, Ambient temperature: –40C to 80C –40F to 176F, Quantity: n=6 5-2. Ambient temperature characteristics (1 Form A 1 Form B) Tested sample: DE1a1b-5V, Ambient temperature: –40C to 80C –40F to 176F, Quantity: n=6 5-3. Ambient temperature characteristics (2 Form A) Tested sample: DE2a-5V, Ambient temperature: –40C to 80C –40F to 176F, Quantity: n=6 -40 -40 -20 -30 -20 -10 104 140 176 Ambient temperature,°C °F Drop-out voltage Pick-up voltage Rate of change, V% -30 -20 -10 Ambient temperature,°C °F Drop-out voltage Pick-up voltage Rate of change, V% -40 -40 -20 104 140 176 -30 -20 -10 Ambient temperature,°C °F Drop-out voltage Pick-up voltage Rate of change, V% -40 -40 -20 104 140 176

DE (ADE) 5ds_61A01_en_de: 100811D SAFETY STANDARDS For Cautions for Use, see Relay Technical Information. Item UL/C-UL (Recognized) CSA (Certified) VDE (Certified) File No. Contact rating File No. Contact rating File No. Contact rating

1 Form A E120782 PILOT DUTY B300

115944 8A 250V AC (cos =1.0)

1 Form B

115944 8A 250V AC (cos =1.0)

2 Form A E120782 PILOT DUTY B300

115944 8A 250V AC (cos =1.0) 6. Change of contact resistance No. of operations Contact resistance, Ω