Specifications are subject to change without notice (02.04.08) 1 Product Description Timers True Delay on Release Type DBB51

  • Time range 1 to 600 s - capacitor powered
  • Knob-adjustable time setting
  • Automatic start after drop-out of power supply
  • Repeatability: ≤ 0.2%
  • Output: 5 A SPDT relay
  • For mounting on DIN-rail in accordance with DIN/EN 50 022
  • 17.5 mm DIN-rail housing (DIN 43880)
  • Combined AC and DC power supply
  • LED indication for relay status and power supply ON Multi voltage (tr ue) delay on release timer. Time ranges from 1 to 600 s covered by 3 models. Housing 17.5 mm wide suit - able for DIN-rail mounting. Fits in M36 cover. Type Selection Mounting Output Time range Supply: 24 VDC and 24 to 240 VAC For DIN-rail SPDT 1 to 10 s DBB 51 C M24 10S SPDT 6 to 60 s DBB 51 C M24 1M SPDT 60 to 600 s DBB 51 C M24 10M Time Specifications Output Specifications Time ranges Type 10 S 1 to 10 s Type 1 M 6 to 60 s Type 10 M 60 to 600 s Repeatability ≤ 0.2% Time variation Within rated power supply ≤ 0.05% Within ambient temperature ≤ 0.2% Reset Power supply applied for: DBB51CM2410S ≥ 200 ms DBB51CM241M, ≥ 200 ms DBB51CM2410M ≥ 400 ms Output SPDT relay Rated insulation voltage 250 VAC (RMS) Contact Ratings (AgSnO2)µ Resistive loads AC 1 5 A @ 250 VAC DC 12 5 A @ 24 VDC Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC Mechanical life ≥ 30 x 10 operations Electrical life ≥ 10 operations (at 5 A, 250 V, cos ϕ = 1) Operating frequency < 7200 operations / h Dielectric strength Dielectric voltage 2 kVAC (RMS) Rated impulse withstand voltage 2.5 kV (1.2/50 µs) Ordering key Housing Function Type Item number Output Power Supply Range DBB 51 C M24 10M Supply Specifications Power supply Overvoltage cat. III Rated operational voltage (IEC 60664, IEC 60038) through terminals: A1, A2 24 VDC ± 15% and 24 to 240 VAC +10% -15%, 45 to 65 Hz Voltage interruption ≤ 40 ms Rated operational power AC supply: 1.5 VA DC supply: 0.06 W

2 Specifications are subject to change without notice (02.04.08) DBB51 Operation Diagram General Specifications Housing Dimensions 17.5 x 81 x 67.2 mm Material PA66 Weight 70 g Screw terminals Tightening torque Max 0.5 Nm according to IEC EN 60947 Approvals UL, CSA CE Marking Yes EMC Electromagnetic Compatibility Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Timer Specifications According to EN 61812-1 When the power supply is applied the relay operates. When the power supply is interrupted the time period starts and, at the end of the set time period, the relay releases. If power supply is reapplied before the relay releases the time is reset and the relay remains ON. Note: DBB51 shoud not be oper- ated by pulses shorter than 200 ms. For these puroposes the relay DMB51, operated by external contact function, should be used. Time setting Knob adjustable on absolute scale. Wiring Diagram /c109 16 18 L(+) N(-) Mode of Operation/Settings ON OFF Dimensions 67.2 18.7 17.5 Power ON delay ≤ 200 ms Power OFF delay ≤ 100 ms Indication for Power supply ON LED, green Output relay ON LED, yellow (flashing when timing) Environment (EN 60529) Degree of protection IP 20 Pollution degree 3 (IEC 60664) Operating temperature -20 to 60 °C, R.H. < 95% Storage temperature -30 to 80 °C, R.H. < 95%