Specifications are subject to change without notice (14.04.20) 1 Timers True delay on release Types DBB02, PBB02

  • Time range 60 s to 10 h - battery powered
  • 3 time ranges selectable by DIP-switches
  • Knob-adjustable time setting
  • Automatic start after drop-out of power supply
  • Repeatability: ≤ 0.2%
  • Output: 8 A SPDT or 8 A DPDT relay
  • For mounting on DIN-rail in accordance with DIN/EN/ EC 60715 or Plug-in
  • 22.5 mm Euronorm or 36 mm Plug-in module housing
  • Combined AC and DC power supply
  • LED indication for power supply ON Product Description Ordering key DBB 02 C M24 Housing Function Type Item number Output Power Supply Multi voltage true delay on release timer with 3 time ranges from 60 s to 10 h selectable by DIP-switches. The built-in non-replace- able battery (Ni-MH) will be charged while the power supply is applied. For mounting on DIN-rail (DBB02) or Plug-in (PBB02). Type Selection Mounting Output Housing Supply: 24 to 240 VAC/DC For DIN-rail SPDT D - Housing DBB 02 C M24 DPDT D - Housing DBB 02 D M24 Plug-in SPDT P - Housing PBB 02 C M24 DPDT P - Housing PBB 02 D M24 Time Specifications Time ranges Selectable by DIP-switches 60 to 600 s 0.1 to 1 h 1 to 10 h Repeatability ≤ 0.2% Output Specifications Output SPDT or DPDT relay Rated insulation voltage 250 VAC (RMS) Contact Ratings(AgNi) µ Resistive loads AC 1 8 A @ 250 VAC DC 12 5 A @ 24 VDC Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC Mechanical life ≥ 2 x 10 operations Electrical life AC 1 ≥ 10 operations (at 8 A, 250 V, cos j = 1) Dielectric strength Dielectric voltage 2 kVAC (RMS) Rated impulse withstand voltage 4 kV (1.2/50µs) DBB02 PBB02 Time variation Within rated battery voltage ≤ 1% Within rated power supply ≤ 0.05% Within ambient temperature ≤ 0.2% Reset Power supply applied for min. 200 ms Supply Specifications Power supply Overvoltage cat. III Rated operational voltage (IEC 60664, IEC 60038) through terminals: (DBB02) A1, A2 24 to 240 VAC/DC (PBB02) 2, 10 +10% -15%, 45 to 65 Hz Voltage interruption ≤ 40 ms Rated operational power AC supply: 3.7 VA DC supply: 1.3 W Built-in non-replaceable battery for time function Nominal capacity 70 mAh Charge Via power supply Working life ≥ 500 charge/discharge cycles Note: for the shipment, you must comply with the relevant packaging and labeling regulation.

2 Specifications are subject to change without notice (14.04.20) DBB02, PBB02 General Specifications Power ON delay ≤ 200 ms Power OFF delay ≤ 100 ms Indication for Power supply ON LED, green Environment (EN 60529) Degree of protection IP 20 Pollution degree 3 (DBB02), 2 (PBB02) (IEC 60664) Operating temperature up to 265 VAC, 135 VDC 0 to 60 °C, R.H. < 95% from 135 VDC @5A 0 to 45 °C, R.H. < 95% Storage temperature -30 to 80 °C, R.H. < 95% Mode of Operation Range/Time Setting Adjust the time range set- ting the DIP-switches 1 and 2 as shown below. To access the DIP-switches open the plastic cover using a screwdriver as shown below. Centre knob: Time setting on relative scale: 1 to 10 with respect to the chosen range. Operation Diagram Time range ON OFF ON ON: 60 to 600 s ON ON OFF OFF: 0.1 to 1 h OFF OFF OFF ON: 1 to 10 h ON OFF Housing Dimensions DBB02 22.5 x 80 x 99.5 mm PBB02 36 x 80 x 94 mm Weight Approx 130 g Screw terminals (DBB02) Tightening torque Max 0.5 Nm according to IEC EN 60947 Approval UL, CSA CE Mark Yes EMC Electromagnetic Compatibility Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Timer Specifications According to EN 61812-1 The relay(s) operates as soon as the power supply is applied. When the power supply is interrupted the time period starts and, at the expiration of the set time period, the relay releases. If the power supply is reapplied before the relay released the time is reset and the relay remains ON. The built-in non-replace- able battery (Ni-MH) will be charged while the power supply is applied. Note: DBB02 and PBB02 should not be operated by pulses shorter than 200 ms. For these purposes the relays DMB01 or PMB01, operated by external contact function, should be used. The battery test is per- formed on terminals + and A2 or 7 and 10. It is recommended to con- nect DBB02 and PBB02 to the power supply for 42 h before it is put into regular service in order to compen- sate for energy losses due to, for example, a long stor- age period.

Specifications are subject to change without notice (14.04.20) 3 DBB02, PBB02 Wiring Diagrams Curves DBB02 PBB02 The tables indicate the charging time needed to keep the built-in battery fully charged for a certain adjusted time period. Example Adjusted time period 10h, battery charging time will be about 2.2 h. At 5 operations: 5 x 10 h, bat- tery charging will be 5 x 2,2 h. If the calculated charging time cannot be obtained, then the battery voltage has to be checked, as it must not drop below 4.2 VDC (min. battery voltage). Test can be perfomed on terminals + and A2 or 7 and 10. Charging time (sec) Charging time (sec) Charging time (hrs) Time range 60 to 600 s Time range 0.1 to 1 h Time range 1 to 10 h Dimensions 22.5 80 83.5 99.5 28.5 DIN-rail 28.5 Plug-in