DBA52 CARLOGAVAZZI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Specifications are subject to change without notice (21.07.08) 1

  • Time range 0.1 s to 100 h
  • Knob selection of time range
  • Knob-adjustable time setting
  • Repeatability: ≤ 0.2%
  • Output: 5 A SPDT relay
  • For mounting on DIN-rail in accordance with DIN/EN 50 022
  • 17.5 mm DIN-rail housing
  • Combined AC and DC power supply
  • LED indication for relay status and power supply ON Multi-voltage delay on release timer with 7 knob selectable time ranges with- in 0.1 s and 100 h. For mounting on DIN-rail. Timers Delay on Release Type DBA52 Product Description Ordering Key Housing Function Type Item number Output Power supply DBA 52 C M24 Type Selection Mounting Output Housing Supply: 24 VDC and 24 to 240 VAC DIN-rail SPDT D-Housing DBA 52 C M24 Time Specifications Output Specifications Time ranges Knob Selectable 0.1 to 1 s 1 to 10 s 6 to 60 s 60 to 600 s 0.1 to 1 h 1 to 10 h 10 to 100 h Setting accuracy ≤ 5% Repeatability ≤ 0.2% Time variation Within rated power supply ≤ 0.05%/V Within ambient temperature ≤ 0.2%/ºC Reset Manual reset of time and/or relay Close the trigger contact between pins A1 and Y1 Pulse duration ≥ 100 ms Power supply interruption ≥ 200 ms Output SPDT relay Rated insulation voltage 250 VAC (rms) Contact Ratings (AgSnO2)µ Resistive loads AC 1 5 A @ 250 VAC DC 12 5 A @ 24 VDC Small inductive loadsAC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC Mechanical life ≥ 30 x 106 operations Electrical life ≥ 105 operations (at 5 A, 250 V, cos ϕ = 1) Operating frequency < 7200 operations/h Dielectric strength Dielectric voltage 2 kVAC (rms) Rated impulse withstand volt. 2.5 kV (1.2/50 µs) Supply Specifications Power supply Overvoltage cat. II Rated operational voltage (IEC 60664, IEC 60038) through terminals: A1, A2 24 VDC ±15% and 24 to 240 VAC Voltage interruption ≤ 10 ms Rated operational power AC supply 4 VA DC supply 1.5 W

2 Specifications are subject to change without notice (21.07.08) 67.2 18.7 17.5 Dimensions Operating Diagram DBA52 The relay operates as soon as the trigger contact is closed. The time period begins when the trigger contact is opened. The relay releases at the end of the set delay time or when the power supply is disconnect- ed. The relay operates again when the input contact is closed again. If it is closed before the end of the delay time the relay keeps ON, a new time period begins as soon as the trigger contact is opened again. Additional Load It's possible to wire an addi- tional load (i.e. a relay) between pins Y1 and A2 driven by the trigger contact without damaging the device (see wiring diagram). Yellow LED working mode Timing: Slow blinking Relay ON: See operation diagrams Incorrect knobs position: Fast blinking General Specifications Time Setting Mode of Operation Power ON delay ≤ 100 ms Indication for Power supply ON LED, green Output relays ON LED, yellow (flashing when timing) Environment (EN 60529) Degree of protection IP 20 Pollution degree 2 (IEC 60664) Operating temperature -20° to +60°C, R.H. < 95% Storage temperature -30° to +80°C, R.H. < 95% Housing Dimensions 17.5 x 81 x 67.2 mm Material PA66 Weight Approx. 75 g Screw terminals Tightening torque Max. 0.5 Nm according to IEC EN 60947 Approvals UL, CSA CE Marking Yes EMC Electromagnetic Compatibility Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Timer Specifications According to EN 61812-1 Function□Dr□-□Delay□on□release Power□supply Relay□ON Trigger□input T LED ON OFF L(+) N(-) /c109 16 18 S DBA52 Wiring Diagram Centre knob: Time setting on relative scale: 1 to 10 with r espect to the chosen range. Lower knob: Setting of time range.