UC2000-30GM-IU-R2-V15 PF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Features

• Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 3000 • Analog current and voltage output • Synchronization options • Adjustable acoustic power and sensitivity • Temperature compensation Diagrams Characteristic response curve Distance X [m] Distance Y [m] Curve 1: flat surface 100 mm x 100 mm Curve 2: round bar, Ø 25 mm 0.6 0.4 0.2 0.0 -0.2 -0.4 -0.6 -0.8 X Y

Ultrasonic sensor UC2000-30GM-IUR2-V15 Release date: 2016-08-01 13:43 Date of issue: 2016-08-01 104093_eng.xml Germany: +49 621 776 4411Pepperl+Fuchs Group Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. USA: +1 330 486 0001 Singapore: +65 6779 9091 Dimensions Electrical Connection Pinout Temperature probe Coded plug M30x1.5 114 27.5 LED Standard symbol/Connection: (version IU) Sync. Core colors in accordance with EN 60947-5-2. 0-10 V 4-20 mA + UB - UB (BN) (GY) (BK) (BU) (WH) U 1 BN 2 WH 3 BU 4 BK 5 GY Wire colors in accordance with EN 60947-5-2 (brown) (white) (blue) (black) (gray) Additional Information Analogue output function Near distance of evaluation Far distance of evaluation Analog function Rising slope Falling slope Zero line mode 20 mA/10 V 4 mA/0 V 4 mA/0 V 20 mA/10 V 20 mA/10 V 4 mA/0 V A1= 0 mm A2

Ultrasonic sensor UC2000-30GM-IUR2-V15 Release date: 2016-08-01 13:43 Date of issue: 2016-08-01 104093_eng.xml Germany: +49 621 776 4411Pepperl+Fuchs Group Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. USA: +1 330 486 0001 Singapore: +65 6779 9091 Description of Sensor Functions Programming procedure The sensor features 2 programmable analog outputs with programmable evaluation range. Programming the evaluation range and the operating mode is done either via the sensor's RS232 interf ace and ULTRA3000 software (see the ULTRA3000 software description) or by means of the programming plug at the sensor's back end which is described here. Programming of Evaluation Range 1. Disconnect supply voltage 2. Remove the programming plug to activate program mode. 3. Reconnect supply voltage (Reset) 4. Place the target at th e desired position for A1 5. Momentarily insert the programming plug in position A1 and then remove. This will program the position A1. 6. Place the target at th e desired position for A2 7. Momentarily insert the programming plug in position A2 and then remove. This will program the position A2. Notes: • Removing the programming plug saves the new position into the device memory. • The programming status is indicated by th e LED. A flashing green LED indicates that the target is detected; a flashing red LED indicates that no target is detected. Programming the Operation Mode If the program mode is still activated, continue at number 4. If not, activate program mode by performing the sequence numbers 1 to 3. 1. Disconnect supply voltage 2. Remove the programming plug to activate program mode. 3. Reconnect supply voltage (Reset) 4. Insert the programming plug in position E2/E3. By removing and reinserting the plug, the user can toggle through the three different modes of operation. The selected mode is indicated by the LEDs as shown below: • Rising slope mode, LED A2 flashes • Falling slope mode, LED A1 flashes • Zero line mode, LEDs A1 and A2 flash 5. Once the desired mode is selected, insert the programming plug in position T. This completes the programming procedure and sa ves the switch points and mode of operation. 6. The sensor now operates in normal mode. Note: The programming plug also functions as the temperature compensation. If the programming plug has not been inserted in the T position within 5 minutes, the sensor will return to normal operating mode with the latest saved values, without temperature compensation. Factory settings See technical data. Display The sensor provides LEDs to indicate various conditions. Accessories BF 30 Mounting flange, 30 mm BF 30-F Mounting flange with dead stop, 30 mm BF 5-30 Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm UVW90-M30 Ultrasonic -deflector UVW90-K30 Ultrasonic -deflector UC-30GM-PROG ULTRA3000 Software for ultrasonic sensors, comfort line UC-30GM-R2 DA5-IU-2K-V Process control and indication equipment V15-G-2M-PVC Female cordset, M12, 5-pin, PVC cable Coded plug T E2/E3

Ultrasonic sensor UC2000-30GM-IUR2-V15 Release date: 2016-08-01 13:43 Date of issue: 2016-08-01 104093_eng.xml Germany: +49 621 776 4411Pepperl+Fuchs Group Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. USA: +1 330 486 0001 Singapore: +65 6779 9091 Synchronization This sensor features a synchronization input for suppressing ultrasonic mutual interference ("cross talk"). If this input is not connected, the sensor will operate using internally generated clock pulses. It can be synchronized by applying an external square wave. The pulse duration must be ≥ 100 µs. Each falling edge of the synchronization pulse triggers transmission of a single ultrasonic pulse. If the synchronization signal remains low for ≥ 1 second, the sensor will revert to normal operating mode. Normal operating mode can also be activated by opening the signal connection to the synchronization input (see note below). If the synchronization input goes to a high level for > 1 second, the sensor will switch to standby mode, indicated by the green LED. In this mode, the outputs will remain in the last valid output state. Note: If the option for synchronization is not used, the synchronization input has to be connected to ground (0 V) or the sensor must be operated via a V1 cordset (4-pin). The synchronization function cannot be activated during programming mode and vice versa. The following synchronization modes are possible: 1. Several sensors (max. number see technical data) can be synchronized together by interconnecting their respective synchronization inputs. In this case, each sensor alternately transmits ultrasonic pulses in a self multiplexing mode. No two sensors will transmit pul ses at the same time (see note below). 2. Multiple sensors can be controlled by the same external synchronization signal. In this mode the sensors are triggered in parallel and are syn- chronized by a common external synchronization pulse. 3. A separate synchronization pulse can be sent to each individual sensor. In this mode the sensors operate in external multiplex mode (see note below). 4. A high level (+U B) on the synchronization input switches the sensor to standby mode. Note: Sensor response times will increase proportionally to the number of sensors that are in the synchronization string. This is a result of the multiplex- ing of the ultrasonic transmit and receive signal and the resulting increase in the measurement cycle time. Note on communication with the UC-30GM-R2 interface cable The UC-30GM-R2 interface cable allows for communicati on with the ultras onic sensor using ULTRA3000 software. The cable creates a connection between a PC RS-232 interface and the programming plug socket on the sensor. When connecting to the sensor, make certain the plug is lined up correctly; otherwise no communicati on will be possible. The key of the cable’s plug must be aligned to the groove of the socket on the sensor (not with the arrow symbol on the sen- sor). Programmable parameters with the ULTRA3000 software • Evaluation limits A1 and A2 •O p e r a t i o n m o d e • Sonic speed • Temperature offset (The inherent temp erature-rise of the sensor can be considered in the temperature compensation) • Expansion of the unusable area (for suppression of unusable area echoes) • Reduction of the detection range (for suppression of remote range echoes) • Time of measuring cycle • Acoustic power (interference of the burst duration) • Sensitivity • Behavior of the sensor in case of echo loss • Behavior of the sensor in case of a fault • Average formation via an allo wed number of measuring cycles • Selection of the parameter set, RS 232 or manually Note: When connected to a PC and running the ULTRA3000 software, the sensor can act as a long term data logger as well. Green LED Red LED Yellow LED A1 Yellow LED A2 During Normal Operation - Temperature compensated - with removed programming plug Interference (e.g. compressed air) On Off Off Off On Flashing Object in evaluation range Object in evaluation range remains in previous state Object in sensing range Object in sensing range remains in previous state During Sensor Programming Evaluation limit A1: Object detected No object detected Evaluation limit A2: Object detected No object detected Operation mode: Rising slope mode Falling slope mode Zero line mode Flashing Off Flashing Off On On On Off Flashing Off Flashing Off Off Off Flashing Flashing Off Off Off Flashing Flashing Off Off Flashing Flashing Flashing Off Flashing Standby Flashing Off remains in previous state remains in previous state A1 A2 E2 E3 LED yellow Dual-LED green/red LED yellow Evaluation limit 1 "Power on"/Disturbance Evaluation limit 2 LED-window V15-plug connector (M12x1) 1: TXD 2: RXD 3: not used 4: GND T emperature/program connector (PC connection via inter- face cable UC-30GM-R2) Groove

Ultrasonic sensor UC2000-30GM-IUR2-V15 Release date: 2016-08-01 13:43 Date of issue: 2016-08-01 104093_eng.xml Germany: +49 621 776 4411Pepperl+Fuchs Group Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. USA: +1 330 486 0001 Singapore: +65 6779 9091 Installation conditions If the sensor is installed in an environment where the temperature can fall below 0 °C, one of these mounting flanges must be used for mounting: BF30, BF30-F, or BF 5-30. If the sensor is mounted in a th rough hole using the included steel nuts, it must be mounted at the middle of the threaded hous ing. If it must be mounted at the front end of the threaded housing, plastic nuts with centering ring (optional accessories) must be used.