D340101 ZIEHL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de MINIPAN 352V Universal-Instrument MINIPAN 352V for DIN-rail-mounting Measuring of resistance: Range 0...500 Ω Range 0...30 kΩ Easy programming with 3 buttons and supporting display: Display (zero, fullscale, decimal point) 2 switching points with hysteresis and delays EasyLimit for easy setting of alarms Switching with automatic reset or interlocked MIN/MAX-contacts or operating-/closed cur- rent mode of relays Storage of MIN- and MAX-values Average of multiple measurings Simulation of operation Code-lock against manipulation of settings Outputs 2 potential-free change-over contacts (co) Supply-voltage for external measuring transducer 4-20 mA Sticker with different measuring units included Terminals pluggable Mounting dimensions 72x72 mm Supply-voltage AC/DC 24-240 V Option: analog output 4...20 mA (insulated when externally supplied) With its 4 digit, 14 mm high display, Digital Panelmeters of MINIPAN 352V- series allow the accurate display of different values in the Measuring inputs AC (True RMS), DC current and voltage and measuring of restistance and of temperatures with various sensors are combined in one instrument. Two programmable switching points allow applications as limit-switch or 2- or 3-point con- troller. With EasyLimit the switching points can be set easily. Other parameters are blocked and thus protected from unindended manipulation. With its analog output (option) it is in addition a measuring- transducer. The display can be easily pro- grammed by the user (e.g. input DC 4-20 mA / display 0-350.0 m/s In addition the built-in universal power-supply AC/DC 24-240 V makes it even more versatile. Temperature: Pt 100 (RTD) , Pt 1000, KTY 83 and KTY 84 in 2- or 3-wire connection Thermocouples type B, E, J, K, L, N, R, S, T Measuring range –170 ... +1820 °C Resolution 0.1 °C (up to 999.9 C) Display in °C or °F AC/DC-measuring inputs: 300 mV for measuring current with external shunt 1 and 5 A for direct measu- ring of current (or AC with external transformer) 500 V
10 V for standard signals
Part numbers: D340101 D340110 with analog output
ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de MINIPAN 352V Technical Data MINIPAN 352V AC/DC 24-240 V DC 20 - 297 V (0,85 x 24 V...1,35 x 220 V) AC 20 - 264 V (0,85 x 24 V...1,1 x 240 V) < 5 VA 48...62 Hz potentially separated from supply-voltage (always connect 1 input only at the same time) ± 300 mV / 29 kΩ / max. ±2,5 V ± 10.00 V / 1 MΩ / max. ±50 V ± 500.0 V / 3 MΩ / max. ±600 V ± 20.00 mA / Shunt 8 Ω/ max. ±100 mA ± 1.00 A / Shunt 150 mΩ / max. ±2 A ± 5.00 A / Shunt 30 mΩ / max. ±7,5 A for 10 s 300 mV / 20 kΩ / max. 2,5 V 10.00 V / 1 MΩ / max. 50 V 500.0 V / 3 MΩ / max. 600 V 20.00 mA / Shunt 8 Ω / max. 100 mA 1.00 A / Shunt 150 mΩ / max. 2 A 5.00 A / Shunt 30 mΩ / max. 7,5 A for 10 s 0...500 Ω 0... 30 kΩ Pt 100, Pt 1000, KTY 83, KTY 84, 2- or 3-wire con- nection, line-resistance max. 3x 50 Ω B, E, J, K, L, N, R, S, T < 300 ms x Ø < 700 ms + 300 ms x Ø < 600 ms (3-wire + thermocouple) < 300 ms (2-wire) Typ 2, see "general technical informations" 2x1 change-over) contanct 4-20 mA (insulated when externally supplied) DC 15-20 V / max. 45 mA -1999 / +9999 ± 0,1 % ± 1 Digit ± 0,02 % K ± 0,5 % ± 1 Digit ± 0,05 % K 500 Ω: 0,2 % ± 0,5 Ω 30 kΩ: 0,5 % ±2 Ω 90 x 70 x 58 mm on 35 mm DIN rail according to EN 60 715 or with 2 screws M4 (option) -20...+60 °C IP 30 IP 20 approx. 190 g Power supply Measuring inputs Accuracy Housing Rated supply-voltage Us Tolerance DC Tolerance AC Power consumption Frequency DC-measuring Measuring-range / input- Resistance / overload capacity AC-measuring Measuring-range / input- Resistance / overload capacity Messuring of resistance Temperature-measuring Sensor-input Thermocouples Measuring time DC Measuring time AC Measuring time temperature + Resistance Relay output Analog output Supply-voltage for loop-powered measuring transducer and analog output Resolution Error DC (of FullScale) Error AC (of FullScale) Error resistance (of value) Error Pt 100 (of value) Housing Dimensions (h x w x d) mm Attachment Ambient temperature range Protection housing Protection terminals Weight Output 2011-01-30