Part Number Nomenclature 2 CCT, CRI & R9 Specification . .2 Chromaticity Bin Structure .3 Operating Characteristics . . 8 Optical and Electrical Charac- Mechanical Dimension . . . 11 Generation 6 CXM-11 COB Arrays White LED Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Features:
- High lumen output and efficacy typical
- Over 2185 lm, 147 LPW @ 3000K, 90CRI, Tj = 85ºC
- CCT range 2200K, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K and 6500K
- 3 SDCM and 2 SDCM color binning standard
- Excellent optical emission uniformity and color over angle consistency
- Superior thermal conductivity for uniform heat spreading
- Environmentally friendly: RoHS and REACH compliant
- ENEC certification RoHS REACH
All Luminus COB products are packaged and labeled with part numbers as outlined in the table on page 4 . Luminus may include any smaller chromaticity bin that is contained in the larger bin as part of the ordered part . When shipped, each package will contain only a single flux and chromaticity bin . The part number designation is as follows: CXM 11 NN XX VV QQPP FG W Product Family LES1 CCT2 Min . CRI3 Typical Voltage Package Configurator4 Flux Bin Chromaticity Bin Chip on Board, Multi-die 11 .6mm LES diameter See Note 2 below CRI See Table Below Volts (V) TA60 TC60 Lumens See page 3 for bins Part Number Nomenclature Note: R9 values have a tolerance of +/- 5% CCT, CRI and R9 Values Notes: 1. Light Emitting Surface (LES) Diameter. 2. Correlated Color Temperature (CCT), NN nomenclature corresponds to the following: 22 = 2200K 24 = 2400K 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K 50 = 5000K 65= 6500K 3. Minimum Color Rendering Index (CRI). 4. TC is a standard substrate with sulfur resistance process, TA is an alternative substrate; 6 means gen 6 COB products, 0 means a product with chromaticity on the BBL, 2 stand for chromaticity Below BBL. 5 . Luminus part numbers may be accompanied by prefixes or suffixes . The most common is the “Rev01” suffix indicating a part is fully released and carries a full warranty . These additional characters may appear on shipping labels, packing slips and invoices . In all cases the basic part number described above will always be included . Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Correlated Color Temperatures XX Value CRI *R9 2700K, 3000K, 3500K, 4000K, 5000K, 6500K 80 >80 >0 2200K, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K, 6500K 90 >90 >50 2700K, 3000K 95 >95 >80 3500K, 4000K, 5000K >70
Note: Luminus maintains a +/- 0.005 tolerance on chromaticity (CIEx and CIEy) measurements Chromaticity Bins: 1931 CIE Color Space Chromaticity Bin Structure The following tables describe the chromaticity bin center points, the orientation angle for the MacAdam ellipse (θ °), and the maximum radii for the ellipses . The ANSI Bin is provided for reference . 0.3 0.32 0.34 0.36 0.38 0.4 0.42 0.44 0.46 CIE y CIE x 2700K 3000K 3500K 4000K 5000K Black Body ANSI C78.377-2008 2-step Ellipse 3-step Ellipse 6500K 2400K Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com CCT Center Point Angle 3-step Bin 2-step Bin CIEx CIEy θ (°) a b a b
The following tables describe products with typical flux and minimum flux measured at 450mA and specified at Tj = 85ºC . The values at 25ºC are calculated and shown for reference only . Note: Luminus maintains a +/- 6% tolerance on flux measurements. Luminus maintains a +/- 2% tolerance on CRI measurements. Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com CCT Output Flux (lm) Color Rendering Index (min .) Ordering Part Number Typ . (85ºC) Min . (85ºC) Calculated Typ . (25ºC) 3-step MacAdam Ellipse 2-step MacAdam Ellipse 2200K 1795 1670 1975 90 CXM-11-22-90-36-TA60-F7-3 CXM-11-22-90-36-TA60-F7-2 2400K 1950 1815 2145 90 CXM-11-24-90-36-TA60-F7-3 CXM-11-24-90-36-TA60-F7-2 2700K 2370 2205 2610 80 CXM-11-27-80-36-TA60-F7-3 CXM-11-27-80-36-TA60-F7-2 2105 1960 2315 90 CXM-11-27-90-36-TA60-F7-3 CXM-11-27-90-36-TA60-F7-2 1765 1640 1940 95 CXM-11-27-95-36-TA60-F7-3 CXM-11-27-95-36-TA60-F7-2 3000K 2505 2325 2755 80 CXM-11-30-80-36-TA60-F7-3 CXM-11-30-80-36-TA60-F7-2 2185 2030 2400 90 CXM-11-30-90-36-TA60-F7-3 CXM-11-30-90-36-TA60-F7-2 1860 1730 2045 95 CXM-11-30-95-36-TA60-F7-3 CXM-11-30-95-36-TA60-F7-2 3500K 2550 2370 2805 80 CXM-11-35-80-36-TA60-F7-3 CXM-11-35-80-36-TA60-F7-2 2240 2080 2465 90 CXM-11-35-90-36-TA60-F7-3 CXM-11-35-90-36-TA60-F7-2 1945 1805 2135 95 CXM-11-35-95-36-TA60-F7-3 CXM-11-35-95-36-TA60-F7-2 4000K 2605 2425 2865 80 CXM-11-40-80-36-TA60-F7-3 CXM-11-40-80-36-TA60-F7-2 2290 2130 2520 90 CXM-11-40-90-36-TA60-F7-3 CXM-11-40-90-36-TA60-F7-2 2050 1905 2255 95 CXM-11-40-95-36-TA60-F7-3 CXM-11-40-95-36-TA60-F7-2 5000K 2645 2460 2910 80 CXM-11-50-80-36-TA60-F7-3 CXM-11-50-80-36-TA60-F7-2 2285 2125 2515 90 CXM-11-50-90-36-TA60-F7-3 CXM-11-50-90-36-TA60-F7-2 2145 1995 2360 95 CXM-11-50-95-36-TA60-F7-3 CXM-11-50-95-36-TA60-F7-2 6500K 2565 2385 2825 80 CXM-11-65-80-36-TA60-F7-3 CXM-11-65-80-36-TA60-F7-2 2295 2135 2525 90 CXM-11-65-90-36-TA60-F7-3 CXM-11-65-90-36-TA60-F7-2
The following tables describe products with typical flux and minimum flux measured at 450mA and specified at Tj = 85ºC . The values at 25ºC are calculated and shown for reference only . Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com CCT Output Flux (lm) Color Rendering Index (min .) Ordering Part Number Typ . (85ºC) Min . (85ºC) Calculated Typ . (25ºC) 3-step MacAdam Ellipse 2-step MacAdam Ellipse 2200K 1795 1670 1975 90 CXM-11-22-90-36-TC60-F7-3 CXM-11-22-90-36-TC60-F7-2 2400K 1950 1815 2145 90 CXM-11-24-90-36-TC60-F7-3 CXM-11-24-90-36-TC60-F7-2 2700K 2370 2205 2610 80 CXM-11-27-80-36-TC60-F7-3 CXM-11-27-80-36-TC60-F7-2 2105 1960 2315 90 CXM-11-27-90-36-TC60-F7-3 CXM-11-27-90-36-TC60-F7-2 1765 1640 1940 95 CXM-11-27-95-36-TC60-F7-3 CXM-11-27-95-36-TC60-F7-2 3000K 2505 2325 2755 80 CXM-11-30-80-36-TC60-F7-3 CXM-11-30-80-36-TC60-F7-2 2185 2030 2400 90 CXM-11-30-90-36-TC60-F7-3 CXM-11-30-90-36-TC60-F7-2 1860 1730 2045 95 CXM-11-30-95-36-TC60-F7-3 CXM-11-30-95-36-TC60-F7-2 3500K 2550 2370 2805 80 CXM-11-35-80-36-TC60-F7-3 CXM-11-35-80-36-TC60-F7-2 2240 2080 2465 90 CXM-11-35-90-36-TC60-F7-3 CXM-11-35-90-36-TC60-F7-2 1945 1805 2135 95 CXM-11-35-95-36-TC60-F7-3 CXM-11-35-95-36-TC60-F7-2 4000K 2605 2425 2865 80 CXM-11-40-80-36-TC60-F7-3 CXM-11-40-80-36-TC60-F7-2 2290 2130 2520 90 CXM-11-40-90-36-TC60-F7-3 CXM-11-40-90-36-TC60-F7-2 2050 1905 2255 95 CXM-11-40-95-36-TC60-F7-3 CXM-11-40-95-36-TC60-F7-2 5000K 2645 2460 2910 80 CXM-11-50-80-36-TC60-F7-3 CXM-11-50-80-36-TC60-F7-2 2285 2125 2515 90 CXM-11-50-90-36-TC60-F7-3 CXM-11-50-90-36-TC60-F7-2 2145 1995 2360 95 CXM-11-50-95-36-TC60-F7-3 CXM-11-50-95-36-TC60-F7-2 6500K 2565 2385 2825 80 CXM-11-65-80-36-TC60-F7-3 CXM-11-65-80-36-TC60-F7-2 2295 2135 2525 90 CXM-11-65-90-36-TC60-F7-3 CXM-11-65-90-36-TC60-F7-2 Note: Luminus maintains a +/- 6% tolerance on flux measurements. Luminus maintains a +/- 2% tolerance on CRI measurements.
Note: Luminus maintains a +/- 0.005 tolerance on chromaticity (CIEx and CIEy) measurements Chromaticity Bins: 1931 CIE Color Space Chromaticity Bin Structure The following tables describe the chromaticity bin center points, the orientation angle for the MacAdam ellipse (θ °), and the maximum radii for the ellipses . The ANSI Bin is provided for reference . 0.3000 0.3200 0.3400 0.3600 0.3800 0.4000 0.4200 0.4400 0.4600 CIE y CIE x 2700K 3000K 3500K 4000K Black Body ANSI C78.377-2008 2-step Ellipse 3-step Ellipse 5000K Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com CCT Center Point Angle 3-step Bin 2-step Bin CIEx CIEy θ (°) a b a b
PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com The following tables describe products with typical flux and minimum flux measured at 450mA and specified at Tj = 85ºC . The values at 25ºC are calculated and shown for reference only . CCT Output Flux (lm) Color Rendering Index (min .) Ordering Part Number Typ . (85ºC) Min . (85ºC) Calculated Typ . (25ºC) 3-step MacAdam Ellipse 2-step MacAdam Ellipse 2700K 2005 1865 2205 90 3000K 2125 1980 2340 90 3500K 2180 2025 2400 90 Note: Luminus maintains a +/- 6% tolerance on flux measurements. Luminus maintains a +/- 2% tolerance on CRI measurements.
Operating Characteristics1 Parameter Symbol Minimum Typical Maximum Unit Forward Current2 If 450 1200 mA Forward Voltage3 Vf 31 .4 33 .1 37 .2 V Power 14 .5 44 .5 W Operating Case Temperature Tc 105 ºC Light Emitting Surface Diameter LES 11 .7 mm Thermal Resistance (junction-to-case) Qjc 0 .29 ºC/W Junction Temperature Tj 140 ºC Viewing Angle 120 Degree Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Notes: 1. Device measurements are at Tj =85⁰C. 2. To prevent damage refer to operating conditions and derating curves for appropriate maximum operating conditions 3. Voltage is rated at typical forward current. For voltage at higher drive current, refer to performance graphs. 4. Thermal resistance is measured from LED junction-to-Tc (thermal contact point), at typical current using JESD51-14. 5. Device operation not recommended at drive currents less than 10% of the typical value 6. Caution must be taken not to stare at the light emitted from these LEDs. Under special circumstances, the high intensity could damage the eye.
Relative Output Flux vs. Forward Current @ 85ºC Forward Current vs. Forward Voltage @ 85ºC Optical & Electrical Characteristics Relative Output Flux vs. Junction Temperature Change in Voltage vs. Junction Temperature Change in CIE_x/y vs. Junction Temp. (3000K, 90CRI) Change in CIE_x/y vs. Forward Current (3000K, 90CRI) 31.0 32.0 33.0 34.0 35.0 0 10 20 30 40 50 60 70 80 90 100 110 120 Voltage (Vf) Tj (°C) 80% 90% 100% 110% 120% 130% 0 10 20 30 40 50 60 70 80 90 100 110 120 Relative Luminous Flux Tj (°C) -0.004 -0.002 0.000 0.002 0.004 0.006 0.008 0 10 20 30 40 50 60 70 80 90 100 110 120 Δ CIEx, Δ CIEy Tj (°C) Δ CIEx Δ CIEy -0.002 -0.001 0.000 0.001 Δ CIEx, Δ CIEy If (A) Δ CIEx Δ CIEy 40% 80% 120% 160% 200% 240% 280% Relative Luminous Flux If (A) 30.0 31.0 32.0 33.0 34.0 35.0 36.0 37.0 38.0 Voltage (Vf) If (A) Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com
PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Typical Polar Radiation Pattern Typical Angular Radiation Pattern 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 380 430 480 530 580 630 680 730 780 strength density WLD(nm) Gen 6 Spectrum 22-90 24-90 27-90 30-90 35-90 40-90 50-90 65-90
Mechanical Dimensions (TA) Mechanical Dimensions (TC) Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Note: Unless otherwise specified, tolerance is ± 0.3mm Note: Unless otherwise specified, tolerance is ± 0.3mm
Shipping Container-(TA & TC) Label Information ⑤ ⑥ Notes: ① Manufacturer part number, flux bin and chromaticity bin ② Customer part number ③ Rev.01 indicates a fully released product ④ Box ID ⑤ Production ID ⑥ Total number of units in a box N o te: 45 pcs per tray and 5 trays are stacked together to be sealed in an anti-static bag . N o te: The anti-static bag is boxed for easier storage, 225 pcs per box . Package model -- for illumination Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Label model -- for illustration only
PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Every Luminus LED is fully tested to ensure it meets the high quality standards customers have come to expect from Luminus’ products . Luminus Chip-on-Board (COB) LED series have consistently delivered the highest lumen performance with the best color quality of any COB supplier . Driving performance enhancements through more than 5 generations of COB products has provided Luminus a comprehensive understanding of the lighting market for directional sources positioning Luminus as the COB manufacturer of choice for the most discriminating lighting manufacturers . Technology Overview Test Specifications Traceability Each Luminus COB LED is marked with a 2D bar code that contains a unique serial number . With this serial number, Luminus has the ability to provide customers with actual test data measurements for a specific LED . In addition, the 2D bar code is linked to manufacturing date codes that enables traceability of production processes and materials . Testing Temperature Luminus COB products are measured at temperatures typical for the LED operating in the fixture . Each device is tested at 85ºC junction temperature eliminating the need to scale data sheet specifications to real world situations . Chromaticity Bin Range Chromaticity binning delivers color consistency for every order . Standard products are delivered with a 3-step MacAdam ellipse . This ensures color performance matching in the application . For the most demanding application, Luminus is one of only a few companies that can provide a 2 SDCM bin distribution . These tightly controlled, small distribution bins provide customers predictable, repeatable colors . Reliability Designed from the ground up, the Luminus COB LED is one of the most reliable light sources in the world today . UL and IEC Recognized Compliance Luminus COB arrays are tested in accordance with ANSI/UL 8750 to ensure safe operation for their intended applications . Further, Luminus maintains IEC-62031 safety ratings on all COB products . REACH & RoHS Compliance All LED products manufactured by Luminus are REACH and RoHS compliant and free of hazardous materials, including lead and mercury .
(Part #) Product Datasheet Generation 6 CXM-11 Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Luminus products are designed for robust performance in general lighting application . However, care must be taken when handling and assembling the LEDs into their fixtures . To avoid damaging Luminus COBs please follow these guidelines . The following is an overview of the application notes detailing some of the practices to follow when working with these devices . More detailed information is available on the Luminus web site at www .luminus .com . General Handling Devices are made to be lifted or carried with tweezers on two adjacent corners opposite the contact pads . At no time should the devices be handled by or should anything come in contact with the light emitting surface (LES) area . This area includes the yellow colored circular area and the ring surrounding it . There are electrical connections under the LES which if damaged will cause the device to fail . In addition, the ring frame itself should not be used for moving, lifting or carrying the device . Also do not attach any optics or mechanical holders to the ring as it is not capable to handle the mechanical stress . Storage Condition Please follow the conditions below . Before opened Temperature 5~30ºC, relative humidity less than 60% . After opened Temperature 5~30ºC, relative humidity less than 60% . After opening, LED should be kept in an aluminum moisture proof bag with a moisture absorbent material Avoid Corrosive gas Avoid exposing to air with corrosive gas . If exposed, electrode surface would be damaged, which may affect soldering . More detailed information is available on the Luminus Applications Resources web pages . Handling Notes Static Electricity Luminus COBs are electronic devices which can be damaged by electrostatic discharge (ESD) . Please use appropriate measures to assure the devices do not experience ESD during their handling and or storage . ESD protection guidelines should be used at all time when working with Luminus COBs . Storage Luminus products are delivered in ESD shielded bags and should be stored in these bags until used Transporting When transporting the devices from one assembly area to another, ESD shielded carts and carriers should be used Assembly Individuals handling Luminus COBs during assembly should be trained in ESD protection practices . Assemblers should maintain constant conductive contact with a path to ground by means of a wrist strap, ankle straps, mat or other ESD protection system
(Part #) Product Datasheet PDS-003320 Rev 01 © 2023 Improving Life with Photons www .luminus .com Generation 6 CXM-11 Product Datasheet Chemical Compatibility The resin material used to form the LES can getter hydrocarbons from the surrounding environment . As a result, certain chemical compounds (H2SO4, H2S, SO2, NH3, H3PO4 , etc .) are not recommended for use with the Luminus products . Use of these compounds can cause damage to the light output of the device and may permanently damage the device . Please refer to the table below for a list of the compounds not recommended for use with the Luminus COB products . Common Chemicals Know to Adversely Affect Luminus Devices Acetates Ethers Potassium hydroxide Acetic acid Cl, F or Br containing compounds Siloxanes Acrylates Liquid hydrocarbons Sodium Hydroxide Aldehydes Hydrochloric Acid Sulfur compounds Aldehydes Ketones Sulfuric Acid Amines Nitric Acid Toluene Benzene Phosphoric acid Xylenes Dienes Thermal Interface Material (TIM) Proper thermal management is critical for successful operation of any LED system . Excess operating temperature can reduce the light output of the device . Excessive heating can cause permanent damage to the device . Proper TIM material is a crucial component for effective heat transfer away from the LED during normal operation . Please refer to www .luminus .com for specific recommendations for TIM solutions . Please refer to https://www.luminus.com/resource/application-notes for more application note information .