CTD4X CARLOGAVAZZI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Specifications are subject to change w ithout no tice C TD -4X D S E N G 2 3 05 18 1

  • B us-bar type current transform er
  • 0.5 class, currents from 1 50 to 1 600 A
  • R em ovable panel fixing clips
  • U p to 6 B us-bar isolated fixing screw s
  • D ouble screw term inals (up to 8-w ire connections)
  • Sealable term inal block covers Product De scrip tion M odel Prim ary current Secondary current O ption O rdering Key C able/B us-bar type current transform er w ith D IN -rail/bus- bar and panel m ounting facility. Rated prim ary currents from 15 0 A to 1600 A. Accessories AC Current Transform er (m ax 64x20 m m bus-bar) Type CTD-4X Type Selection Input Specifications O perating frequency 45 to 65 H z M ax. system voltage 0.72 kV R ated insulation level 3 kV/1 m in. @ 5 0 H z Insulation class E (m ax 75 °C ) Short-tim e current rating Ith Typical 100 I n /1 s Idyn 2 .5 I th The short-tim e therm al current I th is anyw ay lim ited by the cable/bus-bar size Extended current rating R efer to R ange Table Security factor (FS) ≤ 5 (C lass: 0.5 , 1 and 3 ) CTD-4X 1250 5A XXX Prim ary current From 15 0 to 1600A (R efer to R ange Table) O ption XXX: none XTX: tropicalization Secondary current 1 A R ated secondary current 5 A or 1 A O utput Specifications Standards According to E N61869-2 Housing PA66, self-extinguishing: UL 94 V-0 M ounting Panel m ounting Standard accessories T w o term inal block screw s. T w o cable/bus-bar fixing screw s. T w o plastic caps for cable/bus-bar fixing screw s. T w o panel m ounting fixing clips. T w o sealable term inal block covers. O ptional accessories E xtended fixing kit: C TD -kit T w o panel m ounting fixing clips. Six cable/bus-bar fixing screw s. G eneral Specifications Six plastic caps for cable/bus-bar fixing screw s Special features 1 A secondary current, T ropicalization W orking tem perature -2 5 °C to: refer to R ange Table (-13 °F to: refer to R ange Table ) (R.H. < 90% non condensing @ 40°C ) Storage tem perature -3 0°C to +70°C (-2 2 °F to 15 8°F) (R.H. < 90% non condensing @ 40°C ) Approvals C E , cURus and C SA Connection Screw type C able cross section area From 1.5 to 6 m m 2 M in/M ax screw s tightening torque relevant to term inal block screw s: From 1 to 2 Nm M ax screw s tightening torque relevant to the cable/bus-bar fixing screw s: 0,3 Nm Protection degree IP00 IP2 0 (w ith sealable term inal block covers + w ire term inals) Cable diam eter M ax. 5 1 m m Bus-bar size Horizontal M ax. 64x2 0, 5 1x43 m m Vertical M ax. 5 1x3 1 m m W eight From 45 0 to 700 g O ptional fixing kit: CTD-kit

2 Specifications are subject to change w ithout no tice C TD -4X D S E N G 2 3 05 18

M odel C TD -4X from 1 50A to 7 00A Prim ary C urrent Tem perature Extended current rating B urden (VA) A C L 0.5 C L 1 CL 3 2 5 0 (@60°C /140°F) 12 0% 2 .5 4.5 2 3 00 (@60°C /140°F) 12 0% 3 4 3 400 (@60°C /140°F) 12 0% 6 9 3 5 00 (@60°C /140°F) 12 0% 10 12 .5 4 600 (@60°C /140°F) 12 0% 11 13 .5 4 700 (@60°C /140°F) 12 0% 12 .5 15 5 M odel C TD -4X from 7 50A to 1 600A Prim ary C urrent Tem perature Extended current rating B urden (VA) A C L 0.5 C L C L 5P5 75 0 (@5 0°C /12 2 °F) 12 0% 13 15 .5 5 800 (@5 0°C /12 2 °F) 12 0% 14 16.5 5 1000 (@5 0°C /12 2 °F) 12 0% 17.5 2 0 6 12 00 (@5 0°C /12 2 °F) 100% (+ ) 2 0 2 2 .5 6 12 5 0 (@5 0°C /12 2 °F) 100% (+ ) 2 0 2 2 .5 6 15 00 (@5 0°C /12 2 °F) 100% (*) 2 7.5 3 0 8 Dim ensions (m m ) Benefits 131,5 113 81,2 49,9 φ 51 20,5 43,5 1 2 3 6 7 8 9 W iring Diagram

  • E asy and quick m ounting on a panel (see figure 1).
  • Protection of screw term inals using specific sealable covers to assure alw ays the best safety (see figure 3 ).
  • B ridging of current transform er output w ithout changing the connection of the secondary, so to avoid any output overvoltage during either the m aintenance or the installation procedure (see figure 4).
  • E asy output and earth connection (see fig. 5 ).
  • Screw term inals com patible w ith any kind of w ire term inals (see figure 6-7-8-9).
  • M ultiple screw s provided w ith isolation cap screw s to grant a strong and reliable fixing of the current transform er to the bus-bar (see figure 10). S1 S2 L N P1 P2 (*) A m ax overload of 12 0% for 1 m in. every 3 0 m in. is allow ed. (+) A continuous overload of 12 0% of the range is allow ed @ am b. tem p. 40°C m ax.